HomeMy WebLinkAboutCut Sheets.pdfHoneywell’s 5809 wireless fixed heat and rate-of-rise temperature sensor offers expanded fire detection and installation flexibility. It is ideal for hard to wire locations and applications that require more than smoke detection. With no wires to run, the 5809 is fast and easy to install. The 5809 combines both rate-of-rise and fixed temperature sensors. Fires typically cause a rapid rise in temperature in the surrounding area. The 5809’s rate-of-rise thermostat senses the rise in temperature and signals an alarm if the increase is 15° or more per minute. A built-in fixed temperature sensor will also signal an alarm if the environmental temperature rises above 135°F. The 5809 is UL Listed (UL521) and CSFM approved for commercial and residential applications. • Contains a built-in transmitter which can send alarm, supervisory and battery condition messages to the system’s receiver/control unit • Powered by a three-volt lithium battery. If the battery voltage gets too low, the 5809 sends a low battery signal to the control panel • Features a tamper switch, which causes a trouble signal to be sent to the control if the unit is removed from the mounting base • UL Listed for Commercial (when using 5881EH Receiver) or Residential applications FEATURES 5809 WIRELESS HEAT DETECTOR ORDERING 5809 Heat Detector L/5809/D October 2007 © 2007 Honeywell International Inc. Honeywell Security & Custom Electronics Honeywell 2 Corporate Center Drive Suite 100 P.O. 9040 Melville, NY 11747 www.honeywell.com 5809 WIRELESS HEAT DETECTOR • Power: - 3V lithium battery (Duracell DL123A, Panasonic CR123A, Sanyo CR123A, Varta CR123A) - Operating temperature: 40° to 140°F (6° to 60°C) - Rate-of-rise temperature: 15°F (8°C) increase per minute (NOTE: Rate-of- rise sensor does not operate above 38°C) - Fixed temperature: 135°F (57°C) - Maximum spacing: 50 ft x 50 ft UL, 30 ft x 30 ft FM (refer to National Fire Alarm Code Standard NFPA 72 for application requirements) - Dimensions: 4.4” diameter/2/2” deep • Agency Listings: - UL 521 Listed for Commercial (when using 5881EH Receiver) or Residential applications • Wireless Transmission Path Test: - A good RF transmission path must be established from the proposed mounting location before permanently installing the detector. To determine that there is a good signal reception from the proposed location, perform the test procedure described in the installation instructions procedure. SPECIFICATIONS: The test procedure should be performed to determine a good RF transmission path and again after installation is completed. CAUTION: The fixed temperature sensor is intended for one-time use. Prolonged heat during testing can damage the unit. If used carefully following the instructions described below, the heat from a portable hair dryer can be used to test the unit. If the round disk on top of the detector detaches, the detector must be replaced. - Activiate the control panel’s test mode - Use either method (a) or (b) or activate the detector (a) Press and release the activation button on the PC board assembly OR (b) Holding a portable hair dryer about 12 to 18 inches away from the detector, turn the dryer on and aim the warm air at the side of the detector. CAUTION:Aiming the dryer directly at the round disk on the detector can damage the unit to be replaced. - The system’s keypad should beep and the detector’s ID should be displayed - Exit the control’s test mode FCC ID: CFS 8DL 5809 This device complies with part 15 of FCC rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. TESTING THE DETECTOR: - You can mount the 5809 on a wall or ceiling within the protection area: - Wall mounting: Mount the detector 4” 6” from the ceiling Ceiling mounting: Mount the detector at least 4” from any wall. Make sure the normal ceiling temperature will not exceed 100°F (37.8° C). - Refer to NFPA Standard 72 for detector spacing and other requirements. Maximum spacing for UL installations is 50’ x 50’ - Avoid mounting the detector near heat generating devices (e.g. ovens, heat vents, furnaces, boilers) IMPORTANT: Heat detectors should be used for property protection. Reliance should not be placed soley on heat detectors for life safety. When life safety is involved, smoke detectors MUST also be used. Detectors must not be painted. MOUNTING THE DETECTOR: 5800CO CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER The 5800CO is a 3V battery powered wireless carbon monoxide (CO) detector intended for use with Honeywell alarm systems that support 5800 Series wireless devices. It provides early warning when its electrochemical sensing technology measures carbon monoxide levels in the air. The 5800CO is specifically designed for system operation and is fully listed to UL 2075 as a system supervised detector.* It contains a piezoelectric horn which generates the ANSI S3.41 temporal 4 pattern in an alarm condition. The detector consists of an electrochemical carbon monoxide sensor assembly coupled with a wireless transmitter. The transmitter can send alarm, trouble, end-of-life, tamper and low battery condition messages to the alarm panel. Since there are no holes to drill or wires to run, you can preserve the beauty of the home or building while protecting its occupants from harmful carbon monoxide gas. The 5800CO is an ideal carbon monoxide detector for difficult to wire locations, applications where room aesthetics are critical or where hazardous materials exist. What is Carbon Monoxide and How Can it Harm Consumers? Carbon monoxide (CO) is an odorless, colorless, tasteless and highly toxic gas that is produced when fuels such as wood, gasoline, charcoal and oil are burned with insufficient air. The majority of residential and commercial fatalities caused from these fuels come from heating systems, engine powered tools and charcoal grills. Carbon monoxide is harmful when inhaled because it displaces oxygen in the blood and deprives the heart, brain and other vital organs of oxygen. Large amounts of CO can overcome a person in minutes without warning—causing them to lose consciousness and suffocate. The 5800CO is designed to warn the end-user well before the CO reaches a fatal level. The detector’s CO sensitivity is evaluated to UL 2034. CO Concentration Min. Time to Alarm Max. Time to Alarm 30 ppm +/- 5 ppm 30 days Indefinite** 70 ppm +/- 5 ppm 60 minutes 240 minutes 150 ppm+/- 5 ppm 10 minutes 50 minutes 400 ppm+/- 5 ppm 4 minutes 15 minutes CO Levels and Time to Alarm *For a complete list of products that support system operation of the 5800CO to UL standard 2075, please visit: www.honeywell.com/security/hsc/resources/agency/co **Life of product Electrochemical Sensing Technology - Electrochemical detectors are the newest, most refined CO detectors available and provide the most accurate measurement of CO concentration obtainable. They can take readings from low levels that may be hazardous over long periods of time to high concentrations that present an immediate danger. Local Sounder - A built-in piezoelectric horn generates the ANSI S3.41 temporal 4 pattern in an alarm condition. The local sounder will also alert the end-user of other conditions such as low battery, detector trouble and end-of-life. LED Status Indicators - Dual LEDs provide local visual indication of the detector’s status–including normal operation, alarm, low battery, trouble and end-of-life (see figure 1). End of Life Timer - When the detector has reached the end of its life, the detector will send a trouble signal to the panel. This indicates that the CO sensor inside the detector has passed the end of its life and the detector needs to be replaced. The detector’s lifespan is approximately six years from the date of manufacture. Full Supervision - The 5800CO is fully supervised to monitor for low battery, case tamper and trouble conditions. Test/Hush Button - This dual purpose button allows the end-user to perform periodic testing of the detector. In the event of a CO alarm, this button will silence the local sounder alarm for a five minute period. Note: the Hush feature will not operate at levels above 350 ppm (parts per million) carbon monoxide (see figure 1). Versatile Mounting - Whether you choose to affix the detector to the ceiling or a wall, mounting is made simple with the enclosed hardware. The mounting base has large mounting ports, which accommodate drywall anchors for easy surface mounting (see figure 2). Tamper Protection and Tamper Resistant Element - The detector has a built-in tamper switch that can communicate back to the control panel in the event it is removed from the base. For an added level of security, the detector also includes a tamper resistant element that prevents removal from the base without the use of a tool (see figure 2). 5800CO CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER KEY FEATURES Figure 1 Figure 2 5800CO CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER MOUNTING RECOMMENDATIONS CO is slightly lighter than air and when heated by a fuel-burning source, the lighter weight and warm temperature of the CO causes it to quickly rise to the ceiling and mix freely with the air. Check with the local Authority Having Jurisdiction (AHJ) for CO detector requirements in your area. Some recommendations for installing the 5800CO are as follows: - On every floor of the facility - Inside any areas that contain a fuel-burning appliance - In the vicinity of flame-fueled appliances, but no closer than 10 feet • For wall mount - The detector should be at least as high as a light switch and at least six inches from the ceiling • For ceiling mount - The detector should be at least 12 inches from any wall SPECIFICATIONS • Power Source: One 3V CR123A lithium battery (included) • Audible Signal (temporal 4 tone):85 dB in alarm (at 10 ft.) • Height:2.3" (58mm) • Diameter:5.3" (135mm) with mounting base • Weight:7 oz. (241 g) without battery • Operating Ambient Temperature Range:32° F to 100° F (0° C to 37.8° C) • Operating Humidity Range:15% to 95% relative humidity, non-condensing • Agency Listings: -Listed to UL standard 2075, *CO sensitivity is evaluated to UL 2034 -5800COA ULC Listed - tested to the CAN/CSA 6.19.01 standard *For a complete list of products that support system operation of the 5800CO to UL standard 2075 and 5800COA ULC standard, please visit: www.honeywell.com/security/hsc/resources/agency/co ORDERING 5800CO Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter 5800COA Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter with ULC listing L/5800COD/D March 2009 © 2009 Honeywell International Inc. Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com 5800WAVE WIRELESS SIREN Honeywell’s 5800WAVE is a fully wireless siren that provides periodic status information and battery back up for an added level of performance and protection. The flexible design simplifies installation, saves time and installs in seconds at any location without the need to run wires. System status is shown on the 5800WAVE with three LED’s directly on the front of the unit. FEATURES • Siren output level is 95 dB at three feet • Transmits module status, including mounting tamper, low battery and AC loss to the control panel • LED; show system status of the device • AC powered with a rechargeable 12 hour battery backup • Plugs in to any standard duplex receptacle and installs in seconds • Provides temporal pulse sounding for fire alarms • Lowers labor costs and saves time • Simplifies installation • Compatible with LYNXR (Rev 10 or higher) and VISTA controls that support the 5883 transceiver SPECIFICATIONS • Dimensions: 4.5" W x 7.5" H x 2.25" D (114mm x 191mm x 57mm) • Output Level: 95 dB at three feet • Frequency of Operation: 345 MHz • Input Voltage: 120VAC • Current: 202mA Typical • Operational Temperature 32° F to 122° F (0° to 50°C) ORDERING 5800WAVE Wireless Siren L/5800WAVE/D March 2008 © 2008 Honeywell International Inc. Honeywell Security & Communications Honeywell 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com FEATURES 5808W3 PHOTOELECTRIC SMOKE/HEAT DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER Honeywell’s 5808W3 is a 3V lithium powered, photoelectronic smoke/heat detector with a built-in wireless transmitter. It is intended for use with any 5800 Series Wireless Receiver/Transceiver for residential installations (for commercial installations, the 5881ENHC or the 5883H receiver is required). The transmitter can send alarm, tamper, maintenance (when control panels are equipped to process maintenance signals), and battery condition messages to the system’s receiver. Smoothing algorithms minimize nuisance alarms by smoothing out short term spikes from dust and smoke – virtually eliminating nuisance alarms. Since there are no holes to drill or wires to run, you can preserve the beauty of the building while protecting it. The 5808W3 is an ideal smoke detector for those difficult to wire locations, applications where room aesthetics are critical, or where hazardous materials exist. All models also feature a restorable, built-in, fixed temperature (135°F) thermal detector that is also capable of sensing a pre-freeze condition if the temperature is below 41°F. • Improved Robust RF Field Strength The distance between the detector and receiver has been significantly increased without the need for a repeater • Smoothing Algorithms Mathematical calculations in the detector’s software that minimize nuisance alarms by smoothing out short term spikes from dust and smoke • Smart Check A signal is sent to the control panel when the detector requires cleaning. This allows a regular, non-emergency service call to clean the detector before it goes into alarm. • Drift Compensation Virtually eliminates nuisance alarms from long-term dust build-up by automatically adjusting the detector’s sensitivity • Removable Detector Cover and Chamber Top The technician is able to quickly and easily clean the detector chamber without disassembling the detector head • Approved UL Listings for Residential and Commercial Applications Both residential and commercial installation requirements are met • Additional LED Status Indicators Identifying between alarm or trouble conditions is a snap with green and red LED status indicators. A green LED denotes a normal condition while the red LED indicates abnormal conditions. • Easy-to-install Mounting Base The sturdy mounting base allows the detector to be more easily installed on uneven surfaces (i.e. stucco). The mounting base has larger mounting ports, which accommodate drywall anchors for easy surface mounting. ADDITIONAL FEATURES: • Utilizes one long-life 3V lithium battery • Microcontroller runs on a 4.0 MHz clock • Horn operates at 3.3 KHz with sound pressure level of 85 dBA at 10 feet • Built-in wireless transmitter, temporal code 3 sounder • Maintenance signal fully complies with the sensitivity test requirement specified in NFPA 72, 7-2.2 and is approved by UL ORDERING 5808W3 Photoelectric Smoke/Heat Detector with Built-in Wireless Transmitter Accessories sold separately: SENS-RDR Hand-held Sensitivity Reader RT i3 Removal Tool used for easy installation and removal of head from base L/5808W3DS/D September 2008 © 2008 Honeywell International Inc. 5808W3 PHOTOELECTRIC SMOKE/HEAT DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER SPECIFICATIONS ACCESSORIES (sold separately) • Dimensions – Diameter: 5.3"*, Height: 2.30" • Weight – 8.5 ounces (without batteries) • Operating Temperature – 32–100° F (0–37.8° C) • Humidity Range – 0% to 95% RH, non-condensing • Air Velocity – 1,000 ft./min. max. • Operating Voltage – 2.5–3.6VDC • Standby Current – 8.5 mA avg. • Alarm Current – 35 mA max. • Power Source – One 3V CR123A lithium Battery† • Audible Output – 85 dB min. at 10 ft. • Fixed Temperature Heat Sensor – 135° F Fixed • Agency Listings – UL268 – Commercial and Residential SENS-RDR Infrared Sensitivity Reader Reduce testing time with the handheld SENS-RDR infrared sensitivity reader. The reader simplifies sensitivity measurements and displays them precisely in terms of percent per foot obscuration. The SENS-RDR eliminates the need for magnets, voltmeters and ladders. RT Removal Tool Simplifies the attachment and removal of the detector head to the mounting base; it may be attached to a threaded extension pole or broom handle thereby eliminating the need for ladders. * With adapter bracket (4.9" without mounting base) †Replacement batteries include Duracell DL123A, Sanyo CR123A, Panasonic CR123A, or ADEMCO 466 Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com DELUXE CUSTOM ALPHA INTEGRATED KEYPAD/RECEIVER 6160RF • 6160 Custom Alpha Keypad • Built in 5881ENH unlimited zone wireless receiver • Compatible with 5828/5828V wireless keypads on VISTA systems* • Single four-wire run is all that’s required • It is the ideal choice where wireless keys are to be used: - Keys can be programmed at the panel, just as they would with the 5881ENH • Fully compatible with all 5800 wireless devices including bidirectional devices* *Not compatible with 5839 • The 5800TM Module needed to support the 5804BD and 5804BDV is already built-in • Supports encrypted operation of the 5804E and 5804BDV four-button keys Easy to Operate • The custom alpha display is easy to read, with large characters and simplified descriptions • The sounder beeps to help identify security system status • Comfortable soft-touch keys labeled with simple commands are illuminated for nighttime visibility • Four larger function keys can be programmed for one touch operation and are accessible even when the door is closed Stylishly Designed • Sleek, white design blends with any décor • Contoured, removable door lets customers customize the keypad for the look they want • With the door closed the keypad has a smooth, unobtrusive appearance WITH DOOR ATTACHED The 6160RF’s integrated keypad and receiver design helps reduce installation, material and inventory costs while increasing valuable add-on opportunities. It adds full wireless capability to any VISTA control without additional wiring or sacrificing zones and can help close sales by easily adding 5804, 5804BDV or 5878 wireless interfaces for end-user remote convenience. Dealers can add the 5828 and 5828V wireless keypads to VISTA for the first time, presenting a tremendous upsell opportunity by letting them offer their customers secondary wireless keypads on every installation with virtually no install time. Dimensions • 5 5/16" H x 7 3/8" W x 1 3/16" D (135mm x 190mm x 30mm) Sounder • Piezoelectric Wiring • - (Black): Ground • + (Red): +12 VDC (Aux. Power) • D1 (Green): “Data In” to control panel • D0 (Yellow): "Data out" from control panel Current • Standby: 50ma • Activated: 150ma Compatibility • Fully compatible with all VISTA controls Honeywell Security & Custom Electronics Honeywell 2 Corporate Center Drive Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com L/6160RF/D September 2007 © 2007 Honeywell International Inc. ORDERING: 6160RF Keypad/Receiver 5828 Wireless Fixed English Keypad 5828V Wireless Talking Fixed English Keypad FEATURES SPECIFICATIONS The VISTA-128BPE is a powerful member of the Honeywell family of commercial alarm panels, integrating burglary, CCTV and access control functions. Many features are available that extend the applications of the VISTA-128BP while simplifying end-user operation. The VISTA-128BP and VISTA-128BPE (VISTA-128BP Rev. 4) are Listed for residential burglary, residential fire and commercial burglary applications (see agency listings in this document for more details). They are compatible with a wide range of AlarmNet communications products for alarm reporting, uploading/downloading and remote services. Standard features (VISTA-128BP and VISTA-128BPE): • Provides nine style-B hardwired zones • Supports up to 119 additional zones using a built-in polling (V-Plex, multiplex) loop interface • Supports up to 127 wireless zones using up to two 5800 series wireless receivers (fewer if using hardwire and/or polling loop zones) • Provides one power-limited bell circuit delivering 1.7Amp (max) at 12Vdc • Provides the ability to control eight separate partitions independently, each functioning as if it had its own separate control • Accommodates 150 user codes with seven authority levels • Accommodates 32 keypad macro commands per system • Keeps a log of up to 512 events • VistaView-100 CCTV support • Supports up to 16 compatible two- wire smoke detectors on zone 1 • Supports up to 50 latching-type glassbreak detectors on zone 8 • Zone 7 may be used for keyswitch arming/disarming • Supports V-Plex®addressable VistaKey access control (up to eight doors and 250 cards) • Easily programmed and maintained by Compass Windows-based downloader • Supports up to 96 programmable outputs • Programmable to meet SIA false alarm prevention specifications. To meet UL approval for ANSI/SIA CP-01-2000 order part number VISTA-128SIA • Panel Linking up to eight panels • Supports eight numeric pager numbers • Supports touchscreen Advanced User Interface (AUI) • Smoke detector reset at keypad • Quick exit • Group bypass • Arm faulted • Event arming • Scheduled check-in • Arm stay by group Enhanced features (VISTA-128BPE only): • Carbon monoxide (CO) zone type support • Expanded RS-232 capability for third party interface and automation • Internet upload/download over AlarmNet GSM, iGSM and IP communicators over the panel's keypad (ECP) bus • Ringback support for AlarmNet communicators (confirmation of closing report) • 24-hour dialer test support for AlarmNet devices FEATURES VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS Basic Hardwired Zones Provides nine style-B hardwired zones with the following characteristics: • EOLR supervision (optional for zones 2-8) supporting N.O. or N.C. sensors (EOLR supervision required for fire and UL burglary installations) • Individually assignable to one of eight partitions Polling Loop Expansion Supports up to 119 additional zones using a built-in polling (V-Plex, multiplex) loop interface. Current draw can total up to 128mA. Polling loop zones have the following characteristics: • Must use V-Plex devices • Supervised by control panel • Individually assignable to one of eight partitions Wireless Expansion Supports up to 127 wireless zones using up to two 5800 series wireless receivers (fewer if using hardwire and/or polling loop zones). Wireless zones have the following characteristics: • Supervised by control panel for check-in signals (except certain non-supervised transmitters) • Tamper protection for supervised transmitters • Individually assignable to one of eight partitions Scheduling Provides the following scheduling capabilities: • Open/close schedules (for control of arming/disarming and reporting) • Holiday schedules (allows different time windows for open/close schedules) • Timed events (for activation of relays, auto-bypassing and unbypassing, auto-arming and disarming, etc.) • Access schedules (for limiting system access to users by time) • End user output programming mode (provides 20 timers for output control) Eight Partitions Provides the ability to control eight separate areas independently, each functioning as if it had its own separate control. Partitioning features include: • A Common Lobby partition (1-8), which can be programmed to arm automatically when the last partition that shares the common lobby is armed, and to disarm when the first partition that shares the common lobby is disarmed • A Master partition (9), used strictly to assign keypads for the purpose of viewing the status of all eight partitions at the same time (master keypads) • All zones assignable to one of eight partitions • Keypads assignable to one of eight partitions or to Master partition 9 to view system status • Ability to assign relays to one or all eight partitions • Ability to display fire and/or burglary and panic and/or trouble conditions at all other partitions’ keypads (selectable option) • Individually programmable account number, entry delay and exit delay by partition ADDITIONAL FEATURES 4293SN Adapters VISTA-128BP 4101SN Relay Module FG1625SN Glassbreak 4208U Eight-zone Expansion Module and 4208EX Eight-zone V-Plex Expander 710Light 748Horn 5881 Wireless Receiver 6160 Console 4204RelayModule Phone Line to Central Station GSM iGSM or Notification Appliances Keyswitch Option 4146 5193 Series Smoke Detectors V-Plex Loop Alpha PagingModule Parallel Printer Serial Printer RS-232 DT7500SN V-Plex DUAL TEC Motion Sensor NOTE: Please refer to the website (www.honeywell.com/security/hsc) for the latest product information. 7847i ECP Bus or VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS 6160 Console Glassbreak Detectors 4944SN Contact 5881ENHC Commercial Wireless Receiver (Max Two) 4204RelayModule 4204CF Supervised NAC Module Supports Up To 16 Conventional Two-WireSmoke Detectors 4209U Group Zoning Module 4190SN Remote Point Module4193SN Serial Interface Module 4959SN Overhead Door ContactIS2500SN V-Plex PIR Motion Sensor 4208U Eight-zone Expansion Module Panel Linking Module Panel Linking Module VISTA-128BP ECP Bus 5808W3WirelessSmokeDetector 5890Wireless PIR5816 Door/Window Transmitter VISTA-128BP 5800 Series Wireless Devices VISTAKey V-Plex Access Control Module 5817CB Universal Contact Monitoring Transmitter 5869 Commercial UL Wireless Hold-up Button Auxiliary Devices • 4204 - Relay Module, four form C contacts • 5881 Series - RF Receiver supporting 5800 wireless detectors • 6160 - Alpha Keypad/Annunciator • 6220S - System Printer used with 4100SM serial module • VA8200 - (PLM) Panel Linking Module • VA8201 - (APM) Alpha Paging Module Manual Pull Stations • 5140MPS-1 • 5140MPS-2 V-Plex (addressable) Devices • 4101SN Single Relay/zone Module • 4190SN Remote Point Module - two zones • 4193SN Two zone Serial Interface Module • 4208EX - Eight zone expander for ULC commercial installations • 4208U Loop Expansion Module - eight zones • 4209U Group zoning Module - two/four zones • 4293SN One zone Serial Interface Module • 4297 Isolation/Extender Module V-Plex (addressable) smoke detectors • VSI Short/Overload Isolation Module • 5193SD • 5193SDT Passive Infrared Detectors • 998MX • IS2500SN • DT7500SN • QUEST2260SN V-Plex (Addressable) Contacts • 4939SN-WH • 4944SN-WH • 4959SN, 9500SN V-Plex Glassbreak Detectors • FG1625SN VISTA Interactive Phone Module • 4286 VIP Module Optional Communicators • AlarmNet Internet/Intranet communicators and digital cellular communicators Access Control • VISTAKey V-Plex (addressable) Access Control • VISTAKey-SK Starter Kit • VISTAKey-EX Expansion Kit CCTV • Optiflex CCTV module Wireless Devices • 5804 - Wireless Key • 5804BD - Bidirectional Key • 5804BDV - Bidirectional with voice • 5816 - Door/Window Transmitter • 5819 - Shock Sensor • 5827BD - Bidirectional Keypad • 5853 - Glassbreak Detector • 5894 - Wireless PIR Motion Sensor • 5890 - Passive Infrared Detection • 5800PIR-OD - Outdoor Motion Sensor • 5870API - Asset Protection Device • 5800PIR/5800PIR-RES/5800PIR- COM—Wireless Motion Detectors • 5800CO/A - Wireless Carbon Monoxide Detector • 5800RP - Wireless Repeater • 5808W3 - Wireless Smoke Detector • 5809 - Wireless Heat Detector Commercial Listed Wireless Devices • 5817CB - Commercial UL Burglary, Universal Contact Monitoring Transmitter* • 5869 - Commercial UL Wireless Hold-up Button* • 5881ENHC and 5883H Receivers *When used with 5881ENHC and/or 5883H receiver. ACCESSORIES ORDERING VISTA-128BP Commercial Burglary Alarm Control Panel (UL Listed) VISTA-128BPE Enhanced Commercial Burglary Alarm Control Panel (ETL Listed as VISTA-128BP Rev. 4, UL Pending) VISTA-128SIAE SIA Approved Enhanced Commercial Burglary Alarm Control Panel L/VSTA128BPD/D April 2010 © 2010 Honeywell International Inc. For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 www.honeywell.com VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS Agency Listed to the Following Standards: • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault • UL611/UL1610 Grades A, AA Central Station • UL365 Grades A, AA Police Connect • UL985 Household Fire • UL1023 Household Burglar Alarm California State Fire Marshall (CSFM) • UL1635 - Digital Alarm Communicator System Units • CAN/ULC - S303 • CAN/ULC - S304 • CAN/ULC - S545 • CAN/ULC - S1023 • For commercial burglary attack proof requirements, use VISTA-ULKT attack proof enclosure Electrical • Voltage Input: From Honeywell No. 1361 Plug-In Transformer or 1361X10 transformer (for X-10 installations) rated 16.5VAC, 40 VA • Use 1361CN plug-in transformer for Canada • Alarm Sounder Output: 10VDC- 13.8VDC, 1.7 amps max., (UL1023, UL609 installations); 750mA less aux. current draw (UL985 installations) • Auxiliary Power Output: 9.6VDC- 13.8VDC, 750mA max. For UL installations, the accessories connected to the output must be UL Listed, and rated to operate in the above voltage range • Backup Battery: 12VDC, 4AH or 7AH sealed-lead acid. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH) recommended • Standby Time: Four hours min. with 750mA aux. load using 7AH battery • Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts). A solid state circuit breaker is used on auxiliary power output to protect against wiring faults (shorts). Main Dialer • Formats Supported: ADEMCO Contact ID, ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low Speed, Sescoa and Radionics Low Speed • Line Seize: Double Pole • Ringer Equivalence: 0.7B Cabinet Dimensions 12-1/2" W X 14 1/2" H X 3" D SPECIFICATIONS Agency Listings 5600 Series Mechanical Heat Detectors System Sensor’s 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Features • Multiple configurations for installations: – Single- and dual-circuit models – Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. • Plain housing for residential installations (Model 5601P) • Easy-to-use terminal screws • A broad range of back box mounting options: – Single gang – 3.5˝ and 4˝ Octagonal – 4˝ square with square to round plaster ring • Reversible mounting bracket Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back boxes. And these models accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/ rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. S2101 3016008 CS630 7270-1653:0167 5601P 5621 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2013 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. SPDS30001 • 7/13 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number _________, listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 3½-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14–22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601P, 5602, 5621, and 5622 only) Mounting 3½-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact Ratings 6–125VAC / 3A 6–28VDC / 1A 125VDC / 0.3A 250VDC / 0.1A Input Terminals 14–22 AWG Ordering Information Model Circuit Identification Method on Exterior Temperature Rating Activation UL Protected Spacing – 10 Foot Ceiling* 5601P Single None 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5602 Single Lettering 194°F (90°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5603 Single Lettering 135°F (57°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5604 Single Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5621 Dual Lettering 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5624 Dual Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 5601P FX/ROR194°F/9 0 °C5602, 5622 FX135°F/5 7 °C5603, 5623 FX194°F/90 °C 5604, 5624 FX/ROR135°F/5 7 °C5621 Agency Listings Mini-Horns The SpectrAlert® Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. Features • 12 and 24V operation • High and low volume settings • Temporal and non-temporal tones • Mounts to single gang back box • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series Mini-Alert™ sounders The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini-horns offer high and low volume settings, and temporal or non-temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini-horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply. They are listed to Underwriter’s Laboratories Standard UL 464 for fire protective signaling systems. S4011 3028007 MEA7-07-E 7135-1653:196 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0414-001 • 12/09 • #2266 Ordering Information Part No.Description MHR Mini-Horn, Red MHW Mini-Horn, White SpectrAlert® Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box. Mini- horn shall be listed to Underwriter’s Laboratories Standard UL464 for fire protective signaling systems. Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. When used with the Sync•Circuit™ Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.6˝L × 2.9˝W × .45˝D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F (0°C to 49°C) Mounting Surface: deep single-gang back box (23/4˝ deep) Flush: Standard 4˝ × 4˝ back box Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8–33 Operating Voltage with MDL 9–33 UL Sound Output and Current Draw Data Sounder Output (dBA) Switch Setting Pattern Output Level 8–17.5 VDC 8–17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16–33 VDC 16–33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non-temporal High 72 71 75 74 80 79 4 Non-temporal Low 70 69 73 72 78 77 Sounder Current Draw (mA RMS) Switch Position Sound Pattern Volume 8–17.5 Volts 16–33 Volts DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19