HomeMy WebLinkAboutSimplex heat 4098-9733.pdfFeatures TrueAlarm® analog sensing provides: • Digital transmission of analog sensor values via IDNet™ or MAPNET II® two-wire communications** For use with the following Simplex® products: • 4010 and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details) • 4020, 4100, and 4120 Series control panels, Universal Transponders and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control panel provides: • Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection • Sensitivity monitoring satisfying NFPA 72® sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity • Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot • Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide: • Seven levels of sensitivity from 0.2% to 3.7% Heat sensors provide: • Fixed temperature sensing • Rate-of-rise temperature sensing • Utility temperature sensing Ionization smoke sensors provide: • Three levels of sensitivity; 0.5%, 0.9%, and 1.3% General features: • UL listed to Standard 268 • Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted • Designed for EMI compatibility • Magnetic test feature is provided • Optional accessories include remote LED alarm indicator and output relays Additional base reference: • For isolator bases, refer to data sheet S4098-0025 • For sounder bases, refer to data sheet S4098-0028 • For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use – City of New York Department of Buildings – MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor’s present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor’s average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base’s LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base’s LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. ** TrueAlarm analog sensors are protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,400,014; 5,543,777; 5,710,541; D383,407; D388,352; D392,573. MAPNET II and IDNet addressable communications designs are protected by U.S. Patent No. 4,796,025. TrueAlarm® Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors – Photoelectric, MEA (NYC) Acceptance* Ionization, and Heat; Standard Bases and Accessories S4098-0019-12 8/2008 Sensor Base Features Base mounted address selection: • Address remains with its programmed location • Accessible from front (DIP switch under sensor) General features: • Automatic identification provides default sensitivity when substituting sensor types • Integral red LED for power-on (pulsing), or alarm or trouble (steady on) • Locking anti-tamper design mounts on standard outlet box • Magnetically operated functional test Sensor Bases 4098-9792, Standard sensor base 4098-9789, Sensor base with wired connections for: • 2098-9808 Remote LED alarm indicator or 4098-9822 relay (unsupervised) 4098-9791, Sensor base with supervised relay driver output (not compatible with 2120 CDT): • Relay operation is programmable and can be manually operated from control panel • Use with remote mount 2098-9737 relay • Also includes wired connections for remote LED alarm indicator or 4098-9822 relay Sensor Base Options 2098-9737, Remote or local mount supervised relay: • DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9822, LED Annunciation Relay: • Activates when base LED is on steady, indicating local alarm or trouble • DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: • Required for surface or semi-flush mounting to 4” square electrical box and for surface mounting to 4” octagonal box • Can be used for cosmetic retrofitting to existing 6-3/8” diameter base product 2098-9808, Remote red LED Alarm Indicator: • Mounts on single gang box (shown in illustration to right) Description TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionization, or heat sensors. Each sensor’s output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. Mounting Reference Electrical Box Requirements: (boxes are by others) Without relay: 4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep With relay : 4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring TrueAlarm Bases 4098-9789, -9791, & -9792 4-7/8" (124 mm) 15/16" (24 mm) 6-3/8" (162 mm) 1/4" (6.4 mm) 4098-9832 Adapter Plate, required for mounting to surface mounted boxes and 4" square flush box Surface mount reference 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess 2098-9737 Relay (mounts in base electrical box or remotely) 4098-9822 Relay (mounts in base electrical box) Relay Size: 2-1/2" X 1-1/2" X 1" (3.75 cubic inches) (64 mm X 38 mm X 25.4 mm) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. 1-1/2" (38 mm) minimum box depth 2 S4098-0019-12 8/2008 TrueAlarm Sensor Bases and Accessories ALARM TrueAlarm Sensors Features Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: • Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation • Rated spacing distance between sensors: Fixed Temp. Setting UL & ULC Spacing FM Spacing, Either Fixed Temperature Setting 135° F (57.2° C) 60 ft x 60 ft (18.3 m) 155° F (68° C) 40 ft x 40 ft (12.2 m) 20 ft x 20 ft (6.1 m) for fixed temperature only; RTI = Quick 50 ft x 50 ft (15.2 m) for fixed temperature with either rate-of-rise selection; RTI = Ultra Fast Smoke Sensors: • Photoelectric or ionization technology sensing • 360° smoke entry for optimum response • Built-in insect screens 4098-9733 Heat Sensor TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° C). In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° C). This feature can provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. 2-3/8" (60 mm) 4-7/8" (124 mm) LED status indicator 4098-9733 Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. 4098-9714 Photoelectric Sensor TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 2-1/8" (54 mm) 4-7/8" (124 mm) LED status indicator 4098-9714 Photoelectric Sensor with Base 4098-9717 Ionization Sensor TrueAlarm Ionization sensors use a single radioactive source with an outer sampling ionization chamber and an inner reference ionization chamber to provide stable operation under fluctuations in environmental conditions such as temperature and humidity. Smoke and invisible combustion gases can freely penetrate the outer chamber. With both chambers ionized by a small radioactive source [Am 241 (Americium)], a very small current flows in the circuit. The presence of particles of combustion will cause a change in the voltage ratio between chambers. This difference is measured by the electronics in the sensor base and digitally transmitted back to the control panel for processing. Three levels of sensitivity are available for each ionization sensor: 0.5, 0.9, and 1.3% per foot of smoke obscuration. 2-1/8" (54 mm) 4-7/8" (124 mm) LED status indicator 4098-9717 Ionization Sensor with Base Application Reference Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm Code®. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide. For detailed application information, refer to 4098 Detectors, Sensors, and Bases Application Manual (574-709). 3 S4098-0019-12 8/2008 TrueAlarm Sensor Bases* Model Description Compatibility Mounting Requirements 4098-9792 Standard Sensor Base, no options Sensors 4098-9714, -9733, & -9717 4” octagonal or 4” square box, 1-1/2” min. depth; or single gang box, 2” min. depth Sensors 4098-9714, -9733, & -9717 4098-9789 Sensor Base with connections for Remote LED Alarm Indicator or Unsupervised Relay 2098-9808 remote LED alarm indicator or 4098-9822 relay Sensors 4098-9714, -9733, & -9717 2098-9737 remote relay (supervised) 4098-9791 Sensor Base with connections for Supervised Remote Relay and connections for Remote Alarm Indicator or Unsupervised Relay 2098-9808 remote alarm indicator or 4098-9822 relay (unsupervised) 4” octagonal or 4” square box Note: Box depth requirements depend on total wire count and wire size, refer to accessories list below for reference. TrueAlarm Sensors Model Description Compatibility Mounting Requirements 4098-9714 Photoelectric Smoke Sensor 4098-9717 Ionization Smoke Sensor 4098-9733 Heat Sensor Bases 4098-9792, 4098-9789, and 4098-9791 Refer to base requirements TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements 2098-9737 Supervised Relay, mounts remote or in base electrical box For use with 4098-9791 base Remote Mounting requires 4” octagonal or 4” square box, 1-1/2” minimum depth Base Mounting requires 4” octagonal box, 2-1/8” deep with 1-1/2” extension ring 2098-9808 Remote Red LED Alarm Indicator on single gang stainless steel plate Single gang box, 1-1/2” minimum depth 4098-9822 Relay, tracks base LED status (unsupervised, mounts only in base electrical box) Bases 4098-9789 and 4098-9791 4” octagonal box, 2-1/8” deep with 1-1/2” extension ring 4098-9832 Adapter Plate Bases 4098-9792, -9789, & -9791 Required for surface or semi-flush mounted 4” square box and for surface mounted 4” octagonal box * Refer to Installation Instructions 574-707 and Application Manual 574-709 for additional information. Tyco is a registered trademark of Tyco International Services GMBH and is used under license. Simplex, the Simplex logo, TrueAlarm, IDNet, and MAPNET II are trademarks of Tyco International Ltd. and its affiliates and are used under license. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4098-0019-12 8/2008 www.tycosafetyproducts-usa-wm.com © 2008 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. General Operating Specifications Communications and Sensor Supervisory Power MAPNET II or IDNet, auto-select, 24-40 VDC w/data, 400 μA typical, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Temperature Range 32° to 100° F (0° to 38° C) with 4098-9717 or 4098 -9733 32° to 122° F (0° to 50° C) Operating Temperature Range with 4098-9714 15° to 122° F (-9° to 50° C) Humidity Range 10 to 95% RH 4098-9714, Photoelectric Sensor Air velocity = 0-2000 ft/min (0-610 m/min) Smoke Sensor Ambient Ratings 4098-9717, Ionization Sensor Air velocity = 0-200 ft/min (0-61 m/min); Altitude is up to 8000 ft (2.4 km) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 μA, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789 and 4098-9791 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TrueAlarm Analog Sensing Product Selection Chart Specifications