HomeMy WebLinkAboutS2.2.pdfSTRUCTURALTIMBER:
r. Structural Timber has been designed and shall be constructed in conformance with provisions of the NDS Specification for
Stress Grade Lumber and its Fastenings. The Contractor shall not cut, notch, or otherwise modiff timber members without the
written consent ofthe Structural engineer.
z. Wall, roof, and floor shehthing shall meet the minimum requirements of the APA and AITC. Provide thicknesses and fasten
to framing members as noted in the Structural Drawings. Panels are to be oriented to span along their strong axis, and all
panel joints are to be staggered.
3. Pre-fabricated structural connectors shall be as manufactured by Simpson Strong-Tie Company; Pleasanton, California or
approved equivalent.
4. Laminated Veneer Lumber (LVL) shall be as manufactured by Boise Cascade Corporation or approved equivalent. Provide
member size as noted in the Structural Drawings (Fb = z,8oo psi minimum). Refer to the Boise Cascade Installation Guide for
further construction requirements.
Drawn By . SDG
Date . o;l2rl2or4Issue. Construction
SDG Proiect No. . n-o67 Hadley Residence Remodel
rrzTYail Valley Drive
Vail, Colorado