HomeMy WebLinkAboutStructural Clarification 2.pdfDerign Group STRUCTURAL ExpERTtsE . pRAcrtcAL SoLUTIoNs NOTE: The follotuing is a response to the structural comments noted. within the Toun o! VqiI Department of Community Deuelopment Building CodeAnalysis & Reuieu comments (see list of comments-belou). IIADLEY RESIDENCE REMODEL ttzTYailValley Drive o Vail, Colorado SDG Project No. t4-o67 May g, zot4 Page r of z Pg.52.3 Pg 52.5 Pg 52.6 Pg 52.7 Pg.52.8 Pg. 52.9 Need to indicate dffired submittal criteria per the tBC 2012 edition, Done to the wrong buitding code. Utilize 2012 IBC ll/hat design loads are being used Provide engneers seal on all structural plans Attached to what? Provide plan refernces Please clarifu see attached and repairs only inciicate design load and how it is being transferred Loolu to be a redsign Clarify if the design is over the percentage for strucural modificarions to the building. This is not a repair but a modification to the buildingr See previuos comments Item Sz.l: This remodel does not require a deferred submittal. The roof trusses are inplace (as part of the original building design & construction). Structural design criteria is as follows: This project is located in The Town of Vail, Eagle County, Colorado and has been designed in accor{dance with the 2012 Edition of the International Residential Code (including applicable amendments and supplements). Design Loads: Roof Live Load: Uniform Snow 8o psf Floor Live Loads: Residential 40 psf Wind Analysis: Basic Wind Speed 9o mph (3-second gust); Exp. 'C' The structural sheets that are pertinent to the design have been stamped (as part of the original submittal). End of Report Sundquist Design Group, Inc. Residential Services Division Post Office Box 676 o Conifer, CO 8o433 (Sog) 819-zzzzphone m