HomeMy WebLinkAboutStructural Clarification 2.pdfDerign Group
STRUCTURAL ExpERTtsE . pRAcrtcAL SoLUTIoNs
NOTE: The follotuing is a response to the structural comments noted. within the
Toun o! VqiI Department of Community Deuelopment Building CodeAnalysis & Reuieu comments (see list of comments-belou).
IIADLEY RESIDENCE REMODEL
ttzTYailValley Drive o Vail, Colorado
SDG Project No. t4-o67
May g, zot4
Page r of z
Pg.52.3
Pg 52.5
Pg 52.6
Pg 52.7
Pg.52.8
Pg. 52.9
Need to indicate dffired submittal criteria per the tBC 2012 edition, Done to the wrong buitding
code. Utilize 2012 IBC
ll/hat design loads are being used
Provide engneers seal on all structural plans
Attached to what? Provide plan refernces
Please clarifu see attached and repairs only
inciicate design load and how it is being transferred
Loolu to be a redsign Clarify if the design is over the percentage for strucural modificarions to the
building. This is not a repair but a modification to the buildingr
See previuos comments
Item Sz.l: This remodel does not require a deferred submittal. The roof trusses are inplace (as part of the original building design & construction).
Structural design criteria is as follows: This project is located in The Town
of Vail, Eagle County, Colorado and has been designed in accor{dance with the
2012 Edition of the International Residential Code (including applicable
amendments and supplements).
Design Loads:
Roof Live Load: Uniform Snow 8o psf
Floor Live Loads: Residential 40 psf
Wind Analysis: Basic Wind Speed 9o mph (3-second gust); Exp. 'C'
The structural sheets that are pertinent to the design have been stamped (as
part of the original submittal).
End of Report
Sundquist Design Group, Inc.
Residential Services Division
Post Office Box 676 o Conifer, CO 8o433
(Sog) 819-zzzzphone