HomeMy WebLinkAboutStructural Clarification 3.pdfHADLEY RESIDENCE REMODEL
ttzTYailValley Drive r Vail, Colorado
SDG Project No. .14-06T
May 5, zol..4
Page z of z
Derign Group
STRUcTURAL ExpERTIsE . PRAcrrcAL SoLUTToNS
Item Sz.s: This note is merely referencing the attached sheets, as in "SEE THE
ATIACHED SHEETS". It's only a note for referencing the attached structural
requirements within the report.
Item 5z.6: This is very straight-forward. Sheet 5z.6 is a copy from the original pre-
engineered truss calculations (the truss supplier's framing plan). We
provided supplemental notes upon this plan so the GC could easily determine
the necessary renovations, using the plan as a guide.
Item Sz.-: The new LVL headers transfer the load from the 'headered" truss (sheet
Sz.8), to the adjoining trusses. The adjoining trusses (sheets Sz.7 & Sz.9) are
reinforced with full-length LVL's along their bottom chords in order to
support the LVL headers.
Item Sz.8: It's not a re-design. The existing truss is being modified (headered). Sheet
Sz.8 is an elevation of the "headered" truss, showing the modification
requirements.
Item Sz.qr See responses above.
End of Report
Sundquist Design Group, Inc.
Residential Services Division
Post Office Box 676 r Conifer, CO 8o+gg
(SoS) 8}8-zzzzphone
,B