HomeMy WebLinkAboutB14-0104 Load Calcs.pdf
P. 970.479.9990 F. 970.479.0619 12 Vail Road, Suite 700 Vail, CO 81657
April 11, 2014
381 Beaver Dam Circle
Vail, CO 81657
Current electrical service to the home: 200 amps.
Current Electrical Load Calcualtions:
• 5,325 SF @ 3VA = 15,975 VA
• Small appliance x2 = 3,000 VA
• Dishwasher x 2 = 2,400 VA
• Refrigerator x 3 = 3,600 VA
• Hood = 800 VA
• Range = 12,000 VA
• Wall ovens = 9,600 VA
• Warming drawer = 1,200 VA
• Laundry = 1,500 VA
• Dryer = 5,000 VA
Subtotal = 55,075 VA
1st 10K VA @ 100% = 10,000 VA
Remainder @ 40% = 18,030 VA
General Load Total = 28,030 VA
----------------------------------------
Boiler & Pumps = 6,000 VA
Heat Tape = 9,000 VA
Heat Total = 15,000 VA
----------------------------------------
15K VA of Heat @ 40% = 6,000 VA
General Load Total = 28,030 VA
TOTAL = 34,030 VA
34,030 VA / 240 V = 142 Amps
There is adequate capacity for the current use as well as the proposed uses.