Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B14-0123 REV1 cut sheets.pdf
520-14-E Lodge at Vail unit 252 Equipment submittal TAG Manufacturer Model#Location Description CU-1 Carrier MXZ-3B30NA patio Multi-indoor inverter heat pump FC-1 & 3 Carrier MSZ-GE09NA Bedrooms 1&2 Wall Mounted indoor fan coil FC-2 Carrier MSZ-GE18NA Living room Wall Mounted indoor fan coil CI-1 Carrier MA333IF MXZ-3B30NA System Control Interface RC-1,2,3 Carrier PAR-21MAA Bedrooms 1&2 and living room Remote controllers EF-1 Panasonic FV08VS3 All Bath rooms Exhaust fan CP-1 Diversatech CP-22 FC-1&2, FC-3 Condensation removal pump Job Name:Location:Date: Purchaser:Engineer: Submitted to:For Reference Approval Construction System Designation:Schedule No.: © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC. GENERAL FEATURES• Compact side discharge outdoor unit• Wireless or wired remote controller, depending on the indoor units used• Quiet operation—both indoor and outdoor units• Automatic fan speed control• Auto restart following power outage• Self-check function—integrated diagnostics• Advanced microprocessor control• Limited warranty: five years on parts and defects and seven years on compressors OPTIONAL OUTDOOR UNIT ACCESSORIES □Air Outlet Guide (MAC-856SG) □3/8" x 1/2" Port Adapter (MAC-A454JP-E) □1/2" x 3/8" Port Adapter (MAC-A455JP-E) □1/2" x 5/8" Port Adapter (MAC-A456JP-E) □1/4" x 3/8" Port Adapter (PAC-493PI) □3/8" x 5/8" Port Adapter (PAC-SG76RJ-E) Cooling*Rated Capacity (Non-ducted/Ducted)...28,400 Btu/h / 27,400 Btu/hMinimum Capacity (Non-ducted/Ducted) ..12,600 Btu/h / 12,600 Btu/hTotal Input (Non-ducted/Ducted)..............3,120 W / 3,330 W Heating at 47°F*Rated Capacity (Non-ducted/Ducted)...28,600 Btu/h / 27,600 Btu/hMinimum Capacity (Non-ducted/Ducted)..11,400 Btu/h / 11,400 Btu/hTotal Input (Non-ducted/Ducted)..............2,150 W / 2,220 W Heating at 17°F*Rated Capacity (Non-ducted/Ducted) ...16,000 Btu/h / 15,100 Btu/hTotal Input (Non-ducted/Ducted).............2,120 W / 2,190 W* Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB / 67ºF (19ºC) WB. Outdoor: 95ºF (35ºC) DB / 75ºF (24ºC) WB.(Heating) - Indoor: 70ºF (21ºC) DB / 60ºF (16ºC) WB. Outdoor: 47ºF (8ºC) DB / 43ºF (6ºC) WB. (Heating at 17ºF) - Indoor: 70ºF (21ºC) DB / 60ºF (16ºC) WB. Outdoor: 17ºF (-8ºC) DB / 15ºF (-9ºC) WB. Electrical RequirementsPower Supply ....................208 / 230V, 1-Phase, 60 HzRecommended Fuse/Breaker Size.......................20 AMCA ............................................. 15 A VoltageIndoor - Outdoor S1-S2 ......................AC 208 / 230VIndoor - Outdoor S2-S3 ........................DC 12 - 24V OPERATING RANGE Indoor Intake Air Temp.Outdoor Intake Air Temp. Cooling Maximum 95ºF (35ºC) DB, 71ºF (22ºC) WB 115ºF (46ºC) DB Minimum 67ºF (19ºC) DB, 57ºF (14ºC) WB 14ºF (-10ºC) DB Heating Maximum 80ºF (27ºC) DB, 67ºF (19ºC) WB 75ºF (24ºC) DB, 65ºF (18ºC) WB Minimum 70ºF (21ºC) DB, 60ºF (16ºC) WB 6ºF (-14ºC) DB, 5ºF (-15ºC) WB Compressor ..................DC Inverter-driven Twin RotaryFan Motor....................................0.93 F.L.A. Sound Pressure LevelCooling (Non-ducted/Ducted)..................... . . 49 dB(A)Heating (Non-ducted/Ducted)...................... . 49 dB(A) DIMENSIONS INCHES / MM W 35-7/16 / 900 D 12-5/8 / 321 H 35-7/16 / 900 Weight ...................................150 lbs. / 68 kgExternal Finish ......................Munsell No. 3Y 7.8 / 1.1Refrigerant Type..................................R410ARefrigerant Pipe Size O.D. ― Three Ports Gas Side...............A: 1/2" / 12.7mm; B,C: 3/8" / 9.52 mm Liquid Side ................................1/4" / 6.35 mmMax. Refrigerant Pipe Length.....................230' / 70 mMax. Piping Length for Each Indoor Unit .............82' / 25 mMax. Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit................49' / 15 m If Indoor Unit is Below Outdoor Unit................33' / 10 mConnection Method ................................Flared SUBMITTAL DATA: MXZ-3B30NA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM (For data on specific indoor units [all ducted, all non-ducted, and both ducted and non-ducted] combinations, see the Technical and Service Manuals.) Outdoor Unit: MXZ-3B30NA MXZ-3B30NA ENERGY EFFICIENCIESCOMPATIBLE INDOOR UNITS Refer to the separate submittal forms for the SEZ, PEAD, MSZ, MFZ, PCA, SLZ, and PLA Indoor Units. Wall-mounted Indoor Units: MSZ-FE09,12,18NA Wall-mounted Indoor Units: MSZ-GE06,09,12,15,18, 24NA Horizontal-ducted Indoor Units: SEZ-KD09,12,15,18NA and PEAD-A24AA Floor-standing Indoor Units: MFZ-KA09,12,18NA Ceiling-suspended Indoor Units: PCA-A24KA Indoor Unit Type SEER EER HSPF COP @ 47°F COP @ 17°F Non-ducted (06 + 06 + 09)17.5 9.1 10.5 3.9 2.77 Ducted and Non-ducted 16 8.7 10.0 3.8 2.775 Ducted (09 + 09 + 09)14.5 8.2 9.5 3.64 2.78 Ceiling-cassette Indoor Units: SLZ-KA09,12,15NA and PLA-A18,24BA © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC. MXZ-3B30NA OPERATION PERFORMANCE • Minimum of two Indoor Units must be connected to the MXZ-3B30NA. • Minimum installed capacity cannot be less than 12,000 Btu/h. • System can operate with only one Indoor Unit turned on (see table below for single Indoor Unit performance). • Indoor Units can be All Non-ducted, All Ducted, or a Combination of Non-ducted and Ducted (Select style as installa- tion requires). • Information provided at 208/230V. Refer to the MXZ Outdoor Unit Service Manual for detailed specifications and additional information per Indoor Unit Combination. Operation Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Power Usage Range (W)Heating Capacity Range (Btu/h) Unit A Unit B Unit C Total Range 6 6,500 --5,200 - 6,500 460 - 580 7,800 --6,800 - 14,400 540 - 1,460 9 9,000 --7,200 - 9,000 580 - 820 10,900 --8,600 - 15,400 780 - 1,520 12 12,000 --7,200 - 12,000 580 - 1,020 13,600 - 14,400 --8,600 - 16,400 780 - 1,600 15 14,000 - 15,000 --7,200 - 15,000 580 - 1,340 18,000 --8,600 - 21,100 780 - 2,280 18 17,200 --7,200 - 17,200 580 - 1,590 21,600 --8,600 - 24,900 780 - 2,770 24 22,000 7,200 - 22,000 580 - 2,200 23,200 --8,600 - 27,800 780 - 3,000 6 + 6 6,500 6,500 -12,000 - 13,000 920 - 960 7,800 7,800 -11,000 - 31,000 740 - 2,560 6 + 9 6,500 9,000 -12,000 - 15,500 920 - 1,260 7,800 10,900 -11,000 - 31,000 740 - 2,560 6 + 12 6,500 12,000 -12,000 - 18,500 920 - 1,600 7,800 13,600 -11,000 - 31,000 740 - 2,560 6 + 15 6,500 14,000 - 15,000 -12,000 - 21,500 920 - 1,940 7,800 18,000 -11,000 - 33,000 740 - 2,800 6 + 18 6,500 17,200 -12,000 - 23,700 920 - 2,460 7,200 19,800 -11,000 - 35,000 740 - 2,920 6 + 24 5,900 20,100 12,000 - 26,000 920 - 2,800 6,800 20,200 -11,000 - 35,000 740 - 2,860 9 + 9 9,000 9,000 -12,000 - 18,000 920 - 1,840 10,900 10,900 -11,000 - 31,000 740 - 2,560 9 + 12 9,000 12,000 -12,000 - 21,000 920 - 2,040 10,900 13,600 - 14,400 -11,000 - 33,000 740 - 2,800 9 + 15 9,000 15,000 -12,000 - 24,000 920 - 2,540 10,100 16,900 -11,000 - 35,000 740 - 2,920 9 + 18 8,900 17,100 -12,000 - 26,000 920 - 2,840 9,000 18,000 -11,000 - 35,000 740 - 2,920 9 + 24 7,600 20,400 -12,000 - 28,000 920 - 3,220 7,300 19,700 -11,000 - 35,000 740 - 2,740 12 + 12 12,000 12,000 -12,000 - 24,000 920 - 2,540 13,500 13,100 - 13,500 -11,000 - 35,000 740 - 2,920 12 + 15 11,500 14,500 -12,000 - 26,000 920 - 2,840 11,600 - 12,000 15,000 - 15,400 -11,000 - 35,000 740 - 2,860 12 + 18 10,400 15,600 -12,000 - 26,000 920 - 2,840 10,400 - 10,800 16,200 - 16,600 -11,000 - 35,000 740 - 2,860 15 + 15 13,000 13,000 -12,000 - 26,000 920 - 2,840 13,500 13,500 -11,000 - 35,000 740 - 2,800 15 + 18 11,700 - 11,800 14,200 - 14,300 -12,000 - 26,000 920 - 2,840 12,300 14,700 -11,000 - 35,000 740 - 2,800 18 + 18 13,000 13,000 -12,000 - 26,000 920 - 2,840 13,500 13,500 -11,000 - 35,000 740 - 2,800 © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC. Operation Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Power Usage Range (W)Heating Capacity Range (Btu/h) Unit A Unit B Unit C Total Range 6 + 6 + 6 6,500 6,500 6,500 12,600 - 19,500 1,000 - 1,600 7,800 7,800 7,800 11,400 - 36,000 740 - 2,820 6 + 6 + 9 6,500 6,500 9,000 12,600 - 22,000 1,000 - 1,940 7,800 7,800 10,900 11,400 - 36,000 740 - 2,820 6 + 6 + 12 6,500 6,500 12,000 12,600 - 25,000 1,000 - 2,330 7,450 - 7,650 7,450 - 7,650 13,300 - 13,700 11,400 - 36,000 740 - 2,820 6 + 6 + 15 6,500 6,500 14,000 - 15,000 12,600 - 28,000 1,000 - 2,580 6,650 6,650 15,300 11,400 - 36,000 740 - 2,820 6 + 6 + 18 6,100 6,100 16,200 12,600 - 28,400 1,000 - 3,190 6,000 6,000 16,600 11,400 - 36,000 740 - 2,820 6 + 9 + 9 6,500 9,000 9,000 12,600 - 24,500 1,000 - 2,290 7,600 10,000 - 10,500 10,000 - 10,500 11,400 - 36,000 740 - 2,820 6 + 9 + 12 6,500 9,000 12,000 12,600 - 27,500 1,000 - 2,690 6,800 - 6,900 8,900 - 9,700 12,000 - 12,400 11,400 - 36,000 740 - 2,820 6 + 9 + 15 6,000 - 6,200 7,900 - 8,700 13,500 - 14,000 12,600 - 28,400 1,000 - 3,260 6,100 8,000 - 8,500 14,000 11,400 - 36,000 740 - 2,820 6 + 9 + 18 5,600 7,300 - 7,600 15,000 12,600 - 28,400 1,000 - 3,260 5,600 7,200 - 7,700 15,300 11,400 - 36,000 740 - 2,820 6 + 12 + 12 6,000 11,200 11,200 12,600 - 28,400 1,000 - 3,260 6,100 - 6,400 11,100 - 11,500 10,900 - 11,250 11,400 - 36,000 740 - 2,820 6 + 12 + 15 5,500 - 5,700 10,200 - 10,500 12,600 - 12,700 12,200 - 28,400 1,000 - 3,260 5,550 - 5,600 9,900 - 10,250 12,800 - 13,100 11,400 - 36,000 740 - 2,820 6 + 15 + 15 5,000 - 5,400 11,200 - 11,700 11,500 - 12,000 12,600 - 28,400 1,000 - 3,260 5,100 11,750 11,750 11,400 - 36,000 740 - 2,820 9 + 9 + 9 8,500 - 9,000 8,500 - 9,000 8,500 - 9,000 12,600 - 27,000 1,000 - 2,950 9,000 - 9,500 9,000 - 9,500 9,000 - 9,500 11,400 - 36,000 740 - 2,820 9 + 9 + 12 8,000 - 8,500 8,000 - 8,500 11,400 12,600 - 28,400 1,000 - 3,330 8,100 - 8,800 8,100 - 8,800 11,000 - 11,400 11,400 - 36,000 740 - 2,820 9 + 9 + 15 7,250 - 8,000 7,250 - 8,000 12,400 - 12,900 12,600 - 28,400 1,000 - 3,330 7,300 - 7,800 7,300 - 7,800 13,000 11,400 - 36,000 740 - 2,820 9 + 9 + 18 6,600 - 7,100 6,600 - 7,100 14,200 12,600 - 28,400 1,000 - 3,330 6,700 - 7,200 6,700 - 7,200 14,200 11,400 - 36,000 740 - 2,820 9 + 12 + 12 7,300 - 7,800 10,300 10,300 12,600 - 28,400 1,000 - 3,330 7,300 - 8,200 10,200 - 10,600 10,000 - 10,400 11,400 - 36,000 740 - 2,820 9 + 12 + 15 6,600 - 7,300 9,500 - 9,700 11,400 - 11,800 12,600 - 28,400 1,000 - 3,330 6,700 - 7,300 9,200 - 9,500 11,900 - 12,100 11,400 - 36,000 740 - 2,820 MXZ-3B30NA OPERATION PERFORMANCE, contd. 3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822 (#3)www.mehvac.comSpecifications are subject to change without notice. © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC.FORM# MXZ-3B30NA for Multiple Indoor Unit Styles - 201109 DIMENSIONS: MXZ-3B30NA Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule No.: Cooling Capacity*.............................9,000 Btu/h Heating Capacity*............................10,900 Btu/h* Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB, 67ºF (19ºC) WB; Outdoor: 95ºF (35ºC) DB, 75ºF (24ºC) WB.(Heating at 47ºF) - Indoor: 70ºF (21ºC) DB, 60ºF (16ºC) WB; Outdoor: 47ºF (8ºC) DB, 43ºF (6ºC) WB.(For data on specific indoor units [all ducted, all non-ducted, and both ducted and non-ducted] combinations, see the MXZ-B Technical and Service Manual.) Electrical RequirementsPower Supply....................208 / 230V, 1-Phase, 60 HzMCA ..............................................1 A VoltageIndoor - Outdoor S1-S2 ......................AC 208 / 230VIndoor - Outdoor S2-S3 .........................DC 12-24V Fan Motor....................................0.76 F.L.A. Airflow (Quiet - Lo - Med - Hi - Super Hi) Cooling .......................145 - 170 - 237 - 321 - 399 Dry CFM109 - 134 - 201 - 286 - 364 Wet CFM Heating .....................145 - 170 - 237 - 321 - 406 CFM Sound Pressure Level (Quiet - Lo - Med - Hi - Super Hi) Cooling .........................19 - 22 - 30 - 37 - 43 dB(A) Heating .........................19 - 22 - 30 - 37 - 43 dB(A) DIMENSIONS UNIT INCHES / MMW 31-7/16 / 799D9-1/8 / 232H11-5/8 / 295 Weight.......................................22 lbs. / 10 kgExternal Finish ......................Munsell No. 1.0Y 9.2 / 0.2Field Drainpipe Size O.D.......................5/8" / 15.88 mm Refrigerant Type .....................................R410ARefrigerant Pipe Size O.D. Gas Side ..................................3/8" / 9.52 mm Liquid Side.................................1/4" / 6.35 mmConnection Method ..................................Flared SUBMITTAL DATA: MSZ-GE09NA. . . . . . . . . . . 9,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS GENERAL FEATURES• Wall-mounted indoor unit• Standard Hybrid Catechin Prefilter is included with indoor unit• Quiet operation• Choice of fan speeds: Quiet, Low, Medium, High, and Super High; Auto fan speed control also included• Wireless remote controller is included; PAR-21MAA wired remote controller can be installed as an option• Indoor unit powered from outdoor unit using A-Control• Auto restart following a power outage• Limited warranty: five years on parts and defects and seven years on compressors Indoor Unit: MSZ-GE09NA Wireless Remote Controller MXZ-B SERIES HEAT-PUMP OUTDOOR UNITS SEZ-KD and PEAD-A24MSZ-GE MXZ-B MULTI-ZONE SYSTEMS CAN INCLUDE:• Ducted Indoor Units: SEZ-KD09,12,15,18NA, PEAD-A24AA• Nonducted Indoor Units: MSZ-GE06,09,12,15,18,24NA, MSZ-FE09,12,18NA, MFZ-KA09,12,18NA, PCA-A24KA, SLZ-KA09,12,15NA, and PLA-A12,18,24BA• A combination of both Ducted and Nonducted Indoor UnitsRefer to the separate submittal forms for the MSZ-GE, MSZ-FE, MFZ-KA, SEZ-KD, SLZ-KA, PEAD, PCA, PLA Indoor Units, and MXZ Outdoor Units.Outdoor Unit: MXZ-4B36NA MSZ-FE MFZ-KA PCA-KA SLZ-KA and PLA-ABA OPTIONAL ACCESSORIESIndoor Unit□ Condensate Pump (230V; SI3100-230)□ Anti-allergy Enzyme Filter (Two pieces per set; MAC-408FT-E) Controller Options□ Wall-mounted Wired Remote Controller (PAR-21MAA requires MAC-397IF)□ MA Contact Terminal Interface (MAC-397IF)□ M-NET Control Adapter (MAC-399IF)□ Remote Temperature Sensor (M21-JKO-307)□ Lockdown Bracket for Handheld Controller (RCMKP1CB) 3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822 (#3)www.mehvac.comSpecifications are subject to change without notice.C SD - MSZ-GE09NA - 201102 © MITSUBISHI ELECTRIC / HVAC 2011 DIMENSIONS: MSZ-GE09NA Job Name:Location:Date: Purchaser:Engineer: Submitted to:For Reference Approval Construction System Designation:Schedule No.: © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC. Cooling*Rated Capacity...............................17,200 Btu/hMinimum Capacity .............................3,700 Btu/hSEER ......................................19.2 Btu/h/WTotal Input......................................1,640 W Heating at 47°F*Rated Capacity...............................21,600 Btu/hMinimum Capacity .............................3,500 Btu/hHSPF .....................................10.0 Btu/h/WTotal Input......................................1,900 W Heating at 17°F*Rated Capacity...............................13,400 Btu/hRated Total Input ................................1,450 WMaximum Capacity............................17,200 Btu/hMaximum Total Input .............................2,080 W* Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB, 67ºF (19ºC) WB; Outdoor: 95ºF (35ºC) DB, 75ºF (24ºC) WB.(Heating at 47ºF) - Indoor: 70ºF (21ºC) DB, 60ºF (16ºC) WB; Outdoor: 47ºF (8ºC) DB, 43ºF (6ºC) WB.(Heating at 17ºF) - Indoor: 70ºF (21ºC) DB, 60ºF (16ºC) WB; Outdoor: 17ºF (-8ºC) DB, 15ºF (-9ºC) WB. Electrical RequirementsPower Supply ....................208 / 230V, 1-Phase, 60 HzBreaker Size.......................................15 A VoltageIndoor - Outdoor S1-S2 ......................AC 208 / 230VIndoor - Outdoor S2-S3 .........................DC 12-24VIndoor - Remote Controller.........................Wireless OPERATING RANGE Indoor Intake Air Temp.Outdoor Intake Air Temp. Cooling Maximum 90°F (32°C) DB,73°F (23°C) WB 115°F (46°C) DB Minimum 67°F (19°C) DB,57°F (14°C) WB 14°F (-10°C) DB Heating Maximum 80°F (27°C) DB,67°F (19°C) WB 75°F (24°C) DB,65°F (18°C) WB Minimum 70°F (21°C) DB,60°F (16°C) WB -4°F (-20°C) DB,-5°F (-21°C) WB Indoor UnitMCA ...............................................1 AFan Motor.....................................0.76 F.L.A.Airflow (Quiet - Lo - Med - Hi - Super Hi) Cooling ................230 - 275 - 339 - 420 - 533 Dry CFM194 - 240 - 304 - 385 - 498 Wet CFM Heating ................230 - 275 - 339 - 431 - 512 Dry CFM Sound Pressure Level (Quiet - Lo - Med - Hi - Super Hi) Cooling ........................28 - 33 - 38 - 44 - 49 dB(A) Heating ........................28 - 33 - 38 - 43 - 49 dB(A) DIMENSIONS UNIT INCHES / MM W 31-7/16 / 799 D 9-1/8 / 232 H 11-5/8 / 295 Weight.....................................22 lbs. / 10 kgExternal Finish .....................Munsell No. 1.0Y 9.2 / 0.2Field Drainpipe Size O.D......................5/8" / 15.88 mm Outdoor UnitCompressor ...................DC Inverter-driven Twin RotaryMCA ..............................................14 AFan Motor.....................................0.93 F.L.A.Sound Pressure Level Cooling ......................................54 dB(A) Heating ......................................56 dB(A) DIMENSIONS INCHES / MM W 33-1/16 / 840 D 13 / 330 H 33-7/16 / 849 Weight ...................................119 lbs. / 54 kgExternal Finish ......................Munsell No. 3Y 7.8 / 1.1Refrigerant Type...................................R410ARefrigerant Pipe Size O.D. Gas Side .................................1/2" / 12.7 mm Liquid Side................................1/4" / 6.35 mmMax. Refrigerant Pipe Length....................100 ft. / 30 mMax. Refrigerant Pipe Height Difference ............50 ft. / 15 mConnection Method ................................Flared SUBMITTAL DATA: MSZ-GE18NA & MUZ-GE18NA.............18,000 BTU/H WALL-MOUNTED HEAT-PUMP SYSTEMS OPTIONAL ACCESSORIESOutdoor Unit □Base Heater (MAC-641BH-U) □Drain Socket Assembly (MAC-811DS) Indoor Unit □Condensate Pump (230V; SI3100-230) □(Two pieces per set; MAC-408FT-E) Controller Options □Wall-mounted Wired Remote Controller (PAR-21MAA; req. MAC-3971F) □MA Contact Terminal Interface (MAC-397IF) □M-NET Control Adapter (MAC-399IF) □Remote Temperature Sensor (M21-JKO-307) □Lockdown Bracket for Hand-held Controller (RCMKP1CB) GENERAL FEATURES• Wall-mounted indoor unit• Standard Hybrid Catechin Prefilter is included with indoor unit• Quiet operation• Choice of fan speeds: Quiet, Low, Medium, High, and Super High Auto fan speed control also included• Hand-held Wireless Remote Controller• Indoor unit powered from outdoor unit using A-Control• Auto restart following a power outage• Base heater is available as an option• Anti-allergy Enzyme Filter• Limited warranty: five years on parts and defects and seven years on the compressor Indoor Unit: MSZ-GE18NA Outdoor Unit: MUZ-GE18NA Wireless Remote Controller 3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822 (#3)www.mehvac.comSpecifications are subject to change without notice. © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC.FORM# MSZ-GE18NA & MUZ-GE18NA - 201008 DIMENSIONS: MSZ-GE18NA & MUZ-GE18NA MSZ-GE18NA MUZ-GE18NA Job Name:Location:Date: Purchaser:Engineer: Submitted to:For Reference Approval Construction System Designation:Schedule No.: © 2012 MITSUBISHI ELECTRIC US, INC. M-SERIES Specifications are subject to change without notice. Model: MAC-333IF SyStem COnfiguratiOn Possible components connected with System Control Interface: 1. Centralized Controller (AG-150, GB-50ADA, GB-24*, TC-24*) 2. System Control Interface (MAC-333IF) 3. M-Series Indoor Unit 4. MHK1 Wall-Mounted Remote Controller 5. MA Remote Controller 6. Input Contact (Field Supplied) 7. Output Relay (Field Supplied) 8. M-Net Power Supply Unit (PAC-SC51KUA) 9. External 12VDC Power Supply (Field Supplied) 10. BAC-HD150* or LMAP03U* *GB-24 and TC-24 are not compatible with BAC-HD150 or LMAP03U. For details on individual components, please refer to the appropriate manual(s). maC-333if SyStem COntrOL interfaCe SpeCifiCatiOnS fOr m-SerieS inDOOr unitS • Allows the M-Series indoor units to communicate with the CITY MULTI Controls Network via M-Net • Provides two outputs to allow for the following control scenarios: Note: External 12VDC power supply is required. - Equipment Status and Error - Equipment Status and Auxiliary Heat Source - Equipment Status and Humidifier Control - Auxiliary Heat Source and Humidifier Control • Provides an input to allow remote On/Off control of indoor unit (3-Wire plug adapter included) • Allows the M-Series indoor units to connect to MHK1 Wall-Mounted Wireless Remote Controller when using other MAC-333IF functions Note: External 12VDC power supply is required. • Allows the M-Series indoor units to connect to a MA remote controller • Operating conditions: Indoor only (ambient temperature 32° F to 104° F [0° C to 40° C], no condensation) • Indoor unit connecting cable: Dedicated 5-wire cable included 2 3 8 1 10 4 9 7 7 6 5 3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822www.mehvac.comSpecifications are subject to change without notice. © 2012 MITSUBISHI ELECTRIC US, INC. Model: MAC-333IF – DIMENSIONS 3 MAC-333IF-E(3) External dimensions (2 places indicated by asterisks)Holes to fix the interface to the wall 78-3/4 (2000) ¦2-3/4 (70) 2-1/8 (54) 6-5/16 (160) 17/32 (13.5)5-3/16 (132)1-9/16 (39.5)19/32 (15)Unit: In. (mm) FUNCTIONS AND ELECTRIC WIRING(2) Specifications E-FI333-CAMledoM metIPower supply 12 VDC, Indoor power-receiving systemDimensions54(H) × 160(W) × 70(D)mm Usage conditions 0 to 40 ºC (32 to 104 ºF), no condensation, indoor use only Indoor unit connecting cable Dedicated 5-core cable, 2 m Weight 360 g CN591TB521S B A R2 R1 C -+SW500SW502ONON SW580101LE501TB580TB571 TB530CN560TB520LE502LE581B2A2B1A11234567812345678MAMASW501SW510000M-NetIndoor unit To use centralized control by M-NETMELANS system controller To use MA remote controllerMA remote controller To output or display the state, such as ON/OFF and normal/abnormal, of the room air conditioner etc.DC power source (12V)To CN105(CN92)M-Net2 M-Net1 (Sky Blue)(Gray)To input control signal and control room air conditioner remotely(Orange)(Red)(Orange)(White)(White)Refrigerant address setting switch*For details, refer to 5.2 "MA REMOTE CONTROLLER CONNECTION” in this manual.M-NET address setting switch*For details, refer to 5.1 "M-NET CONNECTION" in this manual.LED for checking communication with connected equipment*For details, refer to 3 (5) "Checking the communication status” in this manual.Function setting switch B*For details, refer to 4 "SETTING OF DIP SWITCH AND ROTARY SWITCH" in this manual.Function setting switch A*For details, refer to 4 "SETTING OF DIP SWITCH AND ROTARY SWITCH" in this manual.LED for checking communica-tion with connected equipment*For details, refer to 3 (5) "Checking the communication status” in this manual.Relay or equipment con-nected to the relay, such as heater and humidi erThis connecting cable is already connected to the interface unit at the factory. (Do not extend this cable by splicing it.)Use the cable speci ed for the external power source.Allowable size and length of the cable and other restrictions depend on the connecting devices and each installation con- guration. For details, refer to the installation manual for MAC-333IF-E and 5.1 "M-NET CONNECTION" in this manual.Allowable size and length of the cable depend on the types of the MA remote controller and each installation con guration. For details, refer to 5.2 “MA REMOTE CONTROLLER CONNECTION” in this manual.Commercially-available card key, coin timer, etc.Allowable length of the cable de-pends on the size of the cable.For details, refer to 5.4 "STATUS SIGNAL OUTPUT" in this manual.A connecting cable (about 15 cm) is provided with the interface. Extend the connecting cable with a cable prepared at your site. FORM# MAC-333IF System Control Interface - 201212 Job Name: Location: Drawing Reference: Schedule No. System No.: Date: Model: PAR-21MAADeluxe MA Remote Controller DELUXE MA REMOTE CONTROLLER (PAR-21MAA) SPECIFICATIONS• Controls group operation for up to 16 indoor units in a single group.• Features selectable multi-lingual LCD (English, Spanish, Chinese, Japanese, German, Italian, Russian, and French).• Supports both Fahrenheit and Celsius.• User functions allow user to set - On/Off - Operation modes cool, heat, dry, fan, auto (R2 Series only) - Set temperature - Fan speed setting - Airflow direction• Range of set temperature depends on the indoor unit. - If R410A PDFY-E / PEFY-E / PFFY-E, then: Cool/Dry: 57°F - 87°F / 14°C - 30°C Heat: 63°F - 83°F / 17°C - 28°C Auto: 63°F - 83°F / 17°C - 28°C - All other R410A indoor units: Cool/Dry: 67°F - 87°F / 19°C - 30°C Heat: 63°F - 83°F / 17°C - 28°C Auto: 67°F - 83°F / 19°C - 28°C• Timer Operation: - Weekly Timer: On/Off/Temperature setting up to 8 times per day of the week in 1-minute increments. - Simple Timer: On and Off time can be set once within 72-hour period in 1-hour increments. - Auto-off Timer: Turns indoor unit Off based on countdown time up to 4-hours in 30-minute increments.• Room Temperature: Displays room temperature sensed either at the indoor unit (default) or at the remote controller.• Set Temperature Range Limit: From the Deluxe MA, the allowable set temperature range can be reduced for cool and heat modes.• Function Lock Out: Prohibits all functions or all functions except On/Off from the Deluxe MA.• Lossnay: For interlocked system, Deluxe MA can set high/ low/Stop on Lossnay.• Diagnostics: Displays four-digit error code and error unit address.• Grouping: Can only be used in same group with other PAR-21MAA Deluxe MA Remote Controllers, PAC-YT51CRB Simple MA Remote Controllers and PAR-FL/A32MA Wireless MA Remote Controllers with up to two remote controllers per group.• Addressing: No addressing required.• Wiring: Connects using two-wire, stranded, non-polar control wire to TB15 connection terminal on the indoor unit. Requires crossover wiring for grouping across indoor units.• Dimensions: 5-1/8" x 3/4" x 4-23/32" (130 x 19 x 120 mm). MAremote controller Non-polarized2-wire Non-polarized2-wire MAremote controller OVERVIEW OF CITY MULTI® CONTROLS NETWORK (CMCN) • Consists of TG-2000 integrated system software, AG-150/ GB-50ADA/GB-24/TC-24 centralized controllers, web browsers, timers, remote controllers, and BMS interfaces.• TG-2000 integrated system software supports up to 40 AG-150/GB-50ADA centralized controllers (licensed for PC software features) for a maximum of 2,000 indoor units from a single PC.• AG-150 centralized controller operates up to 50 indoor units with optional control via a field-supplied PC with licensed software.• GB-50ADA centralized controller operates up to 50 indoor units via a field-supplied PC with licensed software.• GB-24 central controller operates up to 24 indoor units via a field-supplied PC with licensed software.• TC-24 standalone centralized controller operates up to 24 indoor units via an integral touch screen interface.• Remote controllers consist of Deluxe MA, Simple MA Wireless MA, and ME.• I/O controllers consist of DIDO (PAC-YG66DCA) and AI (PAC-YG63MCA) for third-party equipment control.• LonWorks® and BACnet® interfaces also available.• Interlocking of LOSSNAY® ERV units for control via the AG-150/GB-50ADA/GB-24/TC-24 centralized controllers. HVAC Advanced Products DivisionMitsubishi Electric & Electronics USA, Inc. 3400 Lawrenceville Suwanee Rd.Suwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822 (#4)www.mehvac.com Specifications are subject to change without notice.[4- ]23/32[5- ]1/8 3/4 [1- ]13/16 [3- ]9/32(Front view)(Side view) (Rear view) Unit:mm[in.]120130 19[ ] 46 83.5C SD -PAR-21MAA - 1 - 201008 © MITSUBISHI ELECTRIC / HVAC 2010 Certificate Number FM33568 Certificate Number EC97J1227 Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired ISO 9001 certification under Series 9000 of the International Standard Organization (ISO) based on a review of quality warranties for the production of refrigeration and air conditioning equipment. ISO Authorization SystemThe ISO 9000 series is a plant authorization system relating to quality warranties as stipulated by the ISO. ISO 9001 certifies quality warranties based on the "design, development, production, installation and auxiliary services" for products built at an authorized plant. Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired environmentalmanagement system standard ISO 14001 certification. The ISO 14000 series is a set of standards applying to environmental protection set by the International Standard Organization (ISO). Model: PAR-21MAA Specification Submittal Data / Panasonic Ventilation Fan Description Ventilating fan shall be Low Noise ceiling mount type rated for continuous run. Fan shall be ENERGY STAR® rated and certified by the Home Ventilation Institute (HVI). Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: • Four–pole totally enclosed condenser motor rated for continuous run.• Power Rating shall be 120 volts and 60 Hz. • Fan shall be UL and cUL listed for tub/ shower enclosure when used with a GFCI branch circuit wiring. • Motor equipped with thermal–cutoff fuse. • Removable with permanently lub ricated plug-in motor. Housing: • Rust proof paint, galvanized steel body. • 4" oval diameter duct. • Built in backdraft damper. • Double hanger bar system allowing for ideal positioning. Grille: • Attractive design using PP material.• Attaches directly to housing with torsion springs. Warranty: • ALL Parts: For period of 3 years from the date of the original purchase. Architectural Specifications: Ventilation fan shall be of the ceiling or wall mount, ENERGY STAR rated type, with no less than 80 CFM and no more than 1.3 sone as certified by the Home Ventilating Institute (HVI) at 0.1 static pressure in inches water gauge (w.g.) with no less than 65 CFM and no more than 1.5 sone as certified by HVI at 0.25 w.g. Power Consumption shall be no greater than 23.3 watts at 0.1 w.g. and 23.6 watts at 0.25 w.g. ENERGY STAR rated with efficiency of no less than 3.4 CFM/ watt at 0.1 w.g. and 2.8 CFM/watt at 0.25 w.g. The motor shall be totally enclosed, four pole condenser type engineered to run continuously. Power rating shall be 120v/60Hz. Duct diameter shall be no less than 4". Fan shall be UL and cUL listed for wall installation and tub/shower enclosure when used with GFCI branch circuit wiring. Fan shall be ASHRAE 62.2, LEED, ENERGY STAR IAP, EarthCraft, California Title-24, and WA Ventilation Code compliant. FV-08VS1 Panasonic Home and Environment Company Division of Panasonic Corporation of North America One Panasonic Way Secaucus, NJ 07094 www.panasonic.com/building Specifications: WhisperValue FV-08VS1 4" Oval Duct Ventilation Fan Characteristics (HVI Certified Data) Static Pressure in inches w.g.0.1 0.25 Air Volume (CFM)80 65 Noise (sones)1.3 1.5 Power Consumption (watts)23.3 23.6 Energy Efficiency (CFM/Watts)3.4 2.8 Speed (RPM)878 1026 Current (amps)0.11 0.11 Power Rating (V/Hz)120/60 California Title-24 Compliant YES ENERGY STAR®YES As of date 4/11 For complete Installation Instructions visit www.panasonic.com/building Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: FV-08VS1 3-3/4” 10-1/4”14-1/2” 13”13” 10-1/4” 14-1/2 or 22-1/2”4-5/8”3-1/16” 4" Oval duct VF11142SS-08VS1 Performance Curve 4" Oval duct Specications Condensate Pumps TECHNICAL DATA SHEET www.diversitech.com 1.800.995.2222 CP Series Condensate Pumps High eeciency furnaces and humidiers This product is designed to automatically pump condensate produced by high eeciency boilers and humidiers up to 22’ vertically once the level of condensate in the tank reaches a specied level. DiversiTech CP-22 series pumps beat the industry standard of 20’ li height by 2 feet and come with innovative features such as: vibration dampening feet and motor mounts, metal hang tabs, four inlet holes (and 3 poly covers for the unused), LED indicators, oat switch and duckbill-style check valve, plug protector, and detailed installation instructions. Two terminals are provided allowing the installer exibility to connect air-handler shut-down - an important safety consideration. CP-22 is available with 20’ of 3/8” tubing as well. Utilizing the same great features but in a low-height (4-3/8”) design, the CP-22LP is great for tight spaces. If a smaller job is in order, the CP-16 is an economical alternative that’s based o of the proven CP-22 design. more compact than the CP-22, it’s designed to li to a maximum of 16 feet. The CP-16 shares many of the great features of the CP-22, including hang tabs, four inlet holes, oat switch, overow switch, and a check valve. • Continuous duty 140F°• Maximum inlet temperature 160F°• Not suitable for contact with steam or gasses that exceed 160F° 120 VAC / 230VAC / 60Hz • 1.9 Amps (120VAC)• 1.0 Amps (230VAC) • USA 3-prong molded plug (120VAC)• NEMA 6-15 plug (230VAC) • CP-22 series: 22’• CP-16 series: 16’(Every Diversitech condensate pump is computer tested to ensure excellent performance at all pumping levels.) • CP-22: 1.6 gallons per minute• CP-16: 1.2 gallons per minute • CP-22: 11.8” x 5.9“ x 6.7” (4.9“H low prole)• CP-16: 4.5” x 10.75“ x 6.5”• CP-22: 5 lbs. (4.7 lbs. low prole)• CP-16: 3.8 lbs. • CP-22: 4.4” (1.75” low prole)• CP-16: 3.5” • CP-22: 1/2 gallon• CP-22LP: 3/8 gallon• CP-16: 2/5 gallon • Instruction Booklet• Metal Hang Tabs• Plug Protector• 4’ Remote Shuto Leads w/insulated terminals• Polyethelene inlet covers (3) • 120VBlack - Live/HotWhite - NeutralGreen - Ground(All installations must conform to NEC requirements) • 230VBrown - Live/HotBlue - Live/HotGreen/Yellow - Ground(All installations must conform to NEC requirements) Product Application Purpose Advantages Maximum CondensateTemperatures Rated Voltage Rated Current Draw Input Type Maximum Li Height Flow Rate @ Zero Head Dimensions Inlet Height from Base Tank Capacity Included Accessories Wiring Color References Condensate Pumps TECHNICAL DATA SHEET DOC32215 www.diversitech.com 1.800.995.2222 Package Metrics Producer of Goods Domestic/ForeignCommodity DiversiTech Foreign SKU Specic Package Metrics Catalog No. Description Lift UPC Order Multiple CP-22 CP-22T CP-22-230 CP-22-230T CP-22LP CP-22LP-230 CP-16 CP-16-230 120V 120V w/tubing 230V 230V w/tubing 120V low prole 230V low prole 120V 230V 6 6 6 6 6 6 6 6 095247091263 095247091287 095247092994 095247094578 095247094301 0095247131280 095247123988 095247130207 22’ 22’ 22’ 22’ 22’ 22’ 16’ 16’