HomeMy WebLinkAboutLANDERS 2 - Sheet - A1-1 - SITE PLAN.pdfDN
15.0'
BUILDING
SETBACK
8040
8040
8050
8050
8050
8050
E
3"
8"
8"
6"
6"
8"
8"
8"
10"
6"
10"
4"
8"
8"
6"
6"
6"
3"
3"
8"
6"
6"
3"
6"
S
4"
FRONT SETBACK
REMOVED (4)EXISTING
TREES OTHERS TO REMAIN
ASPHALT
DRIVEWAY
ENTRY
ENTRY
WEST
HOUSE
EAST
HOUSE
ADDITION SHOWN
HATCHED
SITE COVERAGE
AREA = 250 S.F.
GARAGE
GARAGE
SITE COVERAGE
(HOUSES COMBINED)
EXISTING = 3,609 SQ. FT.
ADDITION = 250 SQ. FT.
PROPOSED = 3,859 SQ FT.
NEW ROOF
PROPOSED
DECK ADDITION
0 5' 10' 20 40
970.328.5151 OFFICE
PO Box 1587, Eagle, CO 81631
www.martinmanleyarchitects.com
Project number Date REVISIONS5/2/2014 7:14:12 AM
A1.1 SITE PLAN
1354 LANDERS RENOVATION
Permit Set
03-06-14
John & Debra Landers
1454W Greenhill Court
Vail, CO 81658
1" = 10'-0"
1
SITE PLAN
SATELLITE PHOTO VICINITY MAP
LOCATION
Duplex Residence
Owner: John and Debra Landers
2530 Outlook Trail
Broomfield, CO 80020
Location: 1454 Greenhill Court #W, Vail, CO 81657
Glen Lyon Subdivision Lot 1
Parcel # 2103-124-02-011
PROJECT / CODE SUMMARY
Class of Work: Alteration / Renovation / Addition
Type of Construction: Type V-N
Type of Occupancy: R3 (duplex)
Levels: 2-story
Sprinkler system : No
LANDERS RENOVATION
1454 GREENHILL COURT #W, VAIL, CO
Architect: Jeff Manley - Martin Manley Architects
PO Box 1587
Eagle CO 81631
jeff@martinmanleyarchitects.com
970-328-1299
Sheet List
Sheet Number Sheet Name
A1.1 SITE PLAN
A1.2 AREA PLANS
A2.0 LOWER LEVEL PLAN
A2.1 MAIN LEVEL AND ROOF PLAN
A2.2 ELEVATIONS
A2.3 SECTIONS
A3.1 DETAILS & ENERGY CODE
Grand total: 7
Project to have MORE than 50% of the existing
gypsum wall board to remain intact
INSULATION SUMMARY
ALL MINIMUM INSULATION VALUES FROM IRC 2012
ROOF RAFTERS = R-51 (MIN. R-49)
EXTERIOR WALL INSULATION = R-22 (MIN. R-20)
BASEMENT WALL INSULATION = R-19 (MIN. R-19)
HEATED SLAB INSULATION = R-15 (MIN. R-15)
WINDOWS U-VALUE MAX. = U-.32 (MAX. U-.32)
INSULATION SUBCONTRACTOR MUST VERIFY THAT R-VALUES OF PROPRIETARY
PRODUCTS MEET OR EXCEED THE R-VALUES LISTED ABOVE AND THAT
INSTALLATION PERFORMED PER MANUFACTURER'S SPECIFICATIONS. ALL
INSULATION SHALL COMPLETELY FILL STUD/JOIST SPACES AND HAVE PROPER AIR-
BARRIER SHEATHING ON BOTH SIDES OF THE STUD/JOIST SPACES.
LIGHTING SUMMARY
EXTERIOR LIGHTING:
EXISTING EXTERIOR FIXTURES ARE DARK NIGHT SKY COMPLIANT
AND WILL BE RE-USED IN NEW LOCATIONS.
INTERIOR LIGHTING:
GENERAL CONTRACTOR TO MEET 2009 IRC REQUIREMENT SECTION
N1104.1 LIGHTING EQUIPMENT:
"A MINIMUM OF 50 PERCENT OF THE LAMPS IN PERMANENTLY
INSTALLED LIGHING FIXTURES SHALL BE HIGH-EFFICACY LAMPS.
STRUCTURAL ENGINEERING INDEX
S1 COVER SHEET + DETAILS + GENERAL NOTES
S2 FOUNDATION PLAN + DETAILS
S3 MAIN FLOOR FRAMING PLAN + DETAILS
S4 ROOF FRAMING PLAN + DETAILS
ARCHITECTURAL INDEX
SEE SHEET A3.1 - DETAILS & ENERGY CODE
No. Description
Date
2012 IRC
75 %
high
efficacy
07/16/14