HomeMy WebLinkAboutLANDERS 2 - Sheet - A1-1 - SITE PLAN.pdfDN 15.0' BUILDING SETBACK 8040 8040 8050 8050 8050 8050 E 3" 8" 8" 6" 6" 8" 8" 8" 10" 6" 10" 4" 8" 8" 6" 6" 6" 3" 3" 8" 6" 6" 3" 6" S 4" FRONT SETBACK REMOVED (4)EXISTING TREES OTHERS TO REMAIN ASPHALT DRIVEWAY ENTRY ENTRY WEST HOUSE EAST HOUSE ADDITION SHOWN HATCHED SITE COVERAGE AREA = 250 S.F. GARAGE GARAGE SITE COVERAGE (HOUSES COMBINED) EXISTING = 3,609 SQ. FT. ADDITION = 250 SQ. FT. PROPOSED = 3,859 SQ FT. NEW ROOF PROPOSED DECK ADDITION 0 5' 10' 20 40 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS5/2/2014 7:14:12 AM A1.1 SITE PLAN 1354 LANDERS RENOVATION Permit Set 03-06-14 John & Debra Landers 1454W Greenhill Court Vail, CO 81658 1" = 10'-0" 1 SITE PLAN SATELLITE PHOTO VICINITY MAP LOCATION Duplex Residence Owner: John and Debra Landers 2530 Outlook Trail Broomfield, CO 80020 Location: 1454 Greenhill Court #W, Vail, CO 81657 Glen Lyon Subdivision Lot 1 Parcel # 2103-124-02-011 PROJECT / CODE SUMMARY Class of Work: Alteration / Renovation / Addition Type of Construction: Type V-N Type of Occupancy: R3 (duplex) Levels: 2-story Sprinkler system : No LANDERS RENOVATION 1454 GREENHILL COURT #W, VAIL, CO Architect: Jeff Manley - Martin Manley Architects PO Box 1587 Eagle CO 81631 jeff@martinmanleyarchitects.com 970-328-1299 Sheet List Sheet Number Sheet Name A1.1 SITE PLAN A1.2 AREA PLANS A2.0 LOWER LEVEL PLAN A2.1 MAIN LEVEL AND ROOF PLAN A2.2 ELEVATIONS A2.3 SECTIONS A3.1 DETAILS & ENERGY CODE Grand total: 7 Project to have MORE than 50% of the existing gypsum wall board to remain intact INSULATION SUMMARY ALL MINIMUM INSULATION VALUES FROM IRC 2012 ROOF RAFTERS = R-51 (MIN. R-49) EXTERIOR WALL INSULATION = R-22 (MIN. R-20) BASEMENT WALL INSULATION = R-19 (MIN. R-19) HEATED SLAB INSULATION = R-15 (MIN. R-15) WINDOWS U-VALUE MAX. = U-.32 (MAX. U-.32) INSULATION SUBCONTRACTOR MUST VERIFY THAT R-VALUES OF PROPRIETARY PRODUCTS MEET OR EXCEED THE R-VALUES LISTED ABOVE AND THAT INSTALLATION PERFORMED PER MANUFACTURER'S SPECIFICATIONS. ALL INSULATION SHALL COMPLETELY FILL STUD/JOIST SPACES AND HAVE PROPER AIR- BARRIER SHEATHING ON BOTH SIDES OF THE STUD/JOIST SPACES. LIGHTING SUMMARY EXTERIOR LIGHTING: EXISTING EXTERIOR FIXTURES ARE DARK NIGHT SKY COMPLIANT AND WILL BE RE-USED IN NEW LOCATIONS. INTERIOR LIGHTING: GENERAL CONTRACTOR TO MEET 2009 IRC REQUIREMENT SECTION N1104.1 LIGHTING EQUIPMENT: "A MINIMUM OF 50 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHING FIXTURES SHALL BE HIGH-EFFICACY LAMPS. STRUCTURAL ENGINEERING INDEX S1 COVER SHEET + DETAILS + GENERAL NOTES S2 FOUNDATION PLAN + DETAILS S3 MAIN FLOOR FRAMING PLAN + DETAILS S4 ROOF FRAMING PLAN + DETAILS ARCHITECTURAL INDEX SEE SHEET A3.1 - DETAILS & ENERGY CODE No. Description Date 2012 IRC 75 % high efficacy 07/16/14