HomeMy WebLinkAboutLANDERS 2 - Sheet - A2-3 - SECTIONS.pdf02 Main Floor
8064' - 0"
04 Roof Plate
8073' - 0 1/4"
01 Lower Floor
8054' - 0"
9' - 2"
ADDITION
MASTER
SUITE
BEDROOM
ENTRY
18' - 0"
ROOF
REMOVED
NEW DECK JOISTS (2X10)
NEW DECK WALL
3' - 0"
4
A2.3
5"
12"
DECK CONNECTION DETAIL TO
MATCH EXISTING CONSTRUCTION
8' - 10 1/2"
R-49 INSULATION MIN.
NEW BEAM
NEW RAFTERS
WALL REMOVED
NEW BEAM
8X8 POST W/ STONE VENEER
NEW WALL - STUCCO FINISH TO MATCH
R-22 INSULATION
WINDOW TRIM TO MATCH EXISTING
SOFFIT TO MATCH EXISTING
2' - 6"
A3.1
3
A3.1
1
---
-
EXISTING
RIDGE BEAM
02 Main Floor
8064' - 0"
04 Roof Plate
8073' - 0 1/4"
01 Lower Floor
8054' - 0"
9' - 0 1/4"
EXISTING ROOF
NEW GABLE ROOF
KITCHEN
GREAT
ROOM
NEW
BATH
GARAGE
1' - 4"
4
A2.3
12' - 6" 12' - 6" 5' - 6" 4' - 1 1/2"
ROOF
REMOVED
NEW DECK JOISTS (2X10)
NEW DECK WALL AND RAILING
DECK CONNECTION DETAIL TO
MATCH EXISTING CONSTRUCTION
R-49 INSULATION MIN.
NEW RAFTERS
WALL
REMOVED
NEW BEAM
8X8 POST W/ STONE VENEER
NEW WALL - STUCCO FINISH TO MATCH
R-22 INSULATION
WINDOW TRIM TO MATCH EXISTING
GABLE SOFFIT W/ 12" FASCIA
EXISTING
RIDGE BEAM
NEW BEAM
ROOFING TO MATCH EXISTING
A3.1
3
---
-
02 Main Floor
8064' - 0"
01 Lower Floor
8054' - 0"
Entry
8060' - 0"
NEW GABLE ROOF
ADDITION
NEW HIP ROOF
ADD STONE FULL HEIGHT
ADD STONE WAINSCOT:
MATCH EXISTING STONE MATERIAL, THICKNESS
AND INSTALLATION METHOD.
USE THIN STONE VENEER BEHIND THE EXISTING
GAS METER. STONE IS TO BE INSTALLED TO NOT
INTERFERE WITH THE METER'S OPERATION AND
TO THE STANDARDS OF XCEL GAS.
FLASHING AT STUCCO AND STONE INTERFACE.
107
108
12
4
A2.3
5' - 0"
3' - 0"
02 Main Floor
8064' - 0"
04 Roof Plate
8073' - 0 1/4"
01 Lower Floor
8054' - 0"
Entry
8060' - 0"
3
A2.3
GREAT ROOM
WET BAR
GARAGE LAUNDRY
EXISTING
ROOF
NEW DECK JOISTS (2X10)
NEW DECK RAIILING
DECK CONNECTION DETAIL TO
MATCH EXISTING CONSTRUCTION
NEW BEAM
WALL REMOVED
8X8 POST W/ STONE VENEER
EXISTING WALL
WINDOW TRIM TO MATCH EXISTING
SOFFIT TO MATCH EXISTING
NEW RIDGE
BEAM
NEW ROOF
R-49 MIN.
NEW ROOF
R-49 MIN.
970.328.5151 OFFICE
PO Box 1587, Eagle, CO 81631
www.martinmanleyarchitects.com
Project number Date REVISIONS5/2/2014 7:15:17 AM
A2.3 SECTIONS
1354 LANDERS RENOVATION
Permit Set
03-06-14
John & Debra Landers
1454W Greenhill Court
Vail, CO 81658
1/4" = 1'-0"
2 Section 1
1/4" = 1'-0"
3 Section 2
1/4" = 1'-0"
1
WEST ELEVATION
1/4" = 1'-0"
4
Section 3
No. Description
Date
07/16/14