HomeMy WebLinkAboutLANDERS 2 - Sheet - A3-1 - DETAILS & ENERGY CODE.pdfR-51 INSULATION MAIN LEVEL T.O.PLY. TREATED SILL PLATE W/ CAPILLARY BREAK MAIN LEVEL RIM JOIST STUCCO EIFS SYSTEM (1 1/2") TO MATCH EXISTING OVER WEATHER BARRIER HOUSE WRAP R-22 INSULATION AT RIM JOIST 1 1/2" FINISH FLOOR OVER 1 1/2" LIGHT-WEIGHT CONCRETE HEATED FLOOR 2X6 WOOD STUD WALL EXTERIOR 1/2" SHEATHING THERMAL BREAK 2" 5" 4" 4' - 0" NOTE: SLAB TO EXTEND AT SPECIAL CONDITIONS RE: STRUCT. DWGS. MIN. FROST DEPTH FOUNDATION PROTECTION SYSTEM: COMPOSITE DRAINAGE BOARD W/ FILTER FABRIC TO CONTINUE FROM FOOTING TO WITHIN 8" BELOW FINISH GRADE. -OVER- 1" "DOW" (OR EQUAL) STYROFOAM INSUL. = R-5 TO EXTEND FROM FTG. TO TOP-OF-WALL. -OVER- WATERPROOF MEMBRANE ON CONCRETE WALL TO CONTINUE FROM FOOTING TO 2'-6" ABOVE FINISHED GRADE. ALTERNATE: USE 3/4" "DRAIN & DRY" BOARD INSTEAD OF COMPOSITE DRAINAGE BOARD = TO CONTINUE FROM FOOTING TO WITHIN 8" BELOW FINISH GRADE. = R-3.1 5/8" TYPE "X" GWB R-10 SLAB PERIMETER INSULATION (1 FT. LENGTH): 1/2" RIGID INSULATION + 1 1/2" EIFS INSULATION R-22 BLOWN-IN INSULATION TO COMPLETELY FILL 2X6 STUD WALL CAVITY. R-10 UNDER-SLAB RIGID BOARD INSULATION (2") 3 FT. LENGTH HEATED CONCRETE SLAB (IN-FLOOR RADIANT HEATING SYSTEM) GRANULAR FILL REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION/FOOTING DESIGN AND REINFORCEMENT SLOPED 4" PERFORATED DRAIN PIPE. ALL FOUNDATION WALLS INCLUDING INTERIOR WALLS. RE: SOILS REPORT 5/8" TYPE "X" GYPSUM WALL BOARD (HELD UP FROM SLAB 3/8") BASE TRIM (PROFILE TBD) FINISH GRADE: 6" BELOW SILL PLATE MIN. SLOPE AWAY POLYETHYLENE VAPOR BARRIER PLYWOOD SHEATHING TO OVERLAP SILL PLATE 2" 1' - 0" 3' - 0" CODE MINIMUM RECOMMENDED: FULL COVERAGE OF UNDER-SLAB INSULATION TREATED SILL PLATE W/ CAPILLARY BREAK THERMAL BREAK 2" 5" 4" 4' - 0" MIN. FROST DEPTH FOUNDATION PROTECTION SYSTEM: COMPOSITE DRAINAGE BOARD W/ FILTER FABRIC TO CONTINUE FROM FOOTING TO WITHIN 8" BELOW FINISH GRADE. -OVER- 1" "DOW" (OR EQUAL) STYROFOAM INSUL. = R-5 TO EXTEND FROM FTG. TO TOP-OF-WALL. -OVER- WATERPROOF MEMBRANE ON CONCRETE WALL TO CONTINUE FROM FOOTING TO 2'-6" ABOVE FINISHED GRADE. ALTERNATE: USE 3/4" "DRAIN & DRY" BOARD INSTEAD OF COMPOSITE DRAINAGE BOARD = TO CONTINUE FROM FOOTING TO WITHIN 8" BELOW FINISH GRADE. = R-3.1 R-22 BLOWN-IN INSULATION TO COMPLETELY FILL 2X6 STUD WALL CAVITY. R-10 UNDER-SLAB RIGID BOARD INSULATION (2") RECOMMENDED FULL COVERAGE HEATED CONCRETE SLAB (IN-FLOOR RADIANT HEATING SYSTEM) GRANULAR FILL SLOPED 4" PERFORATED DRAIN PIPE. ALL FOUNDATION WALLS INCLUDING INTERIOR WALLS. RE: SOILS REPORT 5/8" TYPE "X" GYPSUM WALL BOARD (HELD UP FROM SLAB 3/8") BASE TRIM (PROFILE TBD) FINISH GRADE: 6" BELOW SILL PLATE MIN. SLOPE AWAY POLYETHYLENE VAPOR BARRIER PLYWOOD SHEATHING TO OVERLAP SILL PLATE 2" R-14 BLOWN-IN INSULATION TO COMPLETELY FILL 2X4 STUD FURRING WALL CAVITY. WOOD CAP OVER RIGID INSULATION R-5 (1") CONTINUOUS RIGID INSULATION R-10 INSULATION 1/2" RIGID INSULATION + 1 1/2" EIFS INSULATION R-5 (1") CONTINUOUS RIGID INSULATION CLIMATE ZONE FENESTRATION U-FACTOR SKYLIGHT U-FACTOR GLAZED FENESTRATION SHGC CEILING R-VALUE WOOD FRAME WALL R-VALUE MASS WALL R-VALUE FLOOR R-VALUE BASEMENT WALL R-VALUE SLAB R-VALUE & DEPTH CRAWLSPACE WALL R-VALUE 6 .32 .55 NOT REQUIRED 49 20 + 5 (OR 13 + 10) 15 / 20 30 15 / 19 10 , 4 ft. 15 / 19 FROM TABLE R402.1.1 - IRC 2012 FROM TABLE N1102.1.1 - IECC 2012 INSULATION MINIMAL VALUES BY CODE a b c d e f e a. Eagle County lies in climate zone 6B. b. This is a prescriptive maximum u-factor for all windows and doors. c. This means R-20 for cavity insulation + R-5 for exterior continuous insulation. The Town of Vail has not adopted the additional R-5 at this time. d. The second R-value applies when more than half the insulation is on the interior of the mass wall. e. "15/19" means R-15 continuous insulation on the interior or exterior of the basement wall -or- R-19 cavity insulation at the interior of the basement wall (a combination cavity and continuous must equal R-19 as well). f. R-5 shall be added for heated slabs. The R-values and depth dimension can be spread between perimeter and under-slab locations. ADDITIONAL NOTES: N1102.2.1 (R402.2.1) Ceilings with attic spaces. When Secton N1102.1.1 R-38 shall be deemed to satisfy the requirement for R-49 wherever the full height of uncompressed R-38 insulation extends over the wall top plate at the eaves. N1102.2.2 (R402.2.2) Ceilings without attic spaces. Where Secton N1102.1.1 would require insulation levels above R-30 and the design of the roof/ceiling assembly does not allow sufficient space for the required insulation, the minimum required insulation for such roof/ceiling assemblies shall be R-30. This reduction of insulation from the requirements of Secton N1102.1.1 shall be limited to 500 square feet (46 m2) or 20 percent of the total insulated ceiling area, whichever is less. N1102.2.3 (R402.2.3) Eave baffle. For air permeable insulations in vented attics, a baffle shall be installed adjacent to soffit and eave vents. Baffles shall maintain an opening equal or greater than the size of the vent. The baffle shall extend over the top of the attic insulation. The baffle shall be permitted to be any solid material. N1102.2.4 (R402.2.4) Access hatches and doors. Access doors from conditioned spaces to unconditioned spaces (e.g., attics and crawl spaces) shall be weatherstripped and insulated to a level equivalent to the insulation on the surrounding surfaces. Access shall be provided to all equipment that prevents damaging or compressing the insulation. A wood framed or equivalent baffle or retainer is required to be provided when loose fill insulation is installed, the purpose of which is to prevent the loose fill insulation from spilling into the living space when the attic access is opened, and to provide a permanent means of maintaining the installed R-value of the loose fill insulation. N1102.2.5 (R402.2.5) Mass walls. Mass walls for the purposes of this chapter shall be considered above-grade walls of concrete block, concrete, insulated concrete form (ICF), masonry cavity, brick (other than brick veneer), earth (adobe, compressed earth block, rammed earth) and solid timber/logs. N1102.2.7 (R402.2.7) Floors. Floor insulation shall be installed to maintain permanent contact with the underside of the subfloor decking. N1102.2.8 (R402.2.8) Basement walls. Walls associated with conditioned basements shall be insulated from the top of the basement wall down to 10 feet (3048 mm) below grade or to the basement floor, whichever is less. Walls associated with unconditioned basements shall meet this requirement unless the floor overhead is insulated in accordance with Sections N1102.1.1 and N1102.2.7. N1102.2.9 (R402.2.9) Slab-on-grade floors. Slab-on-grade floors with a floor surface less than 12 inches (305 mm) below grade shall be insulated in accordance with Table N1102.1.1. The insulation shall extend downward from the top of the slab on the outside or inside of the foundation wall. Insulation located below grade shall be extended the distance provided in Table N1102.1.1 by any combination of vertical insulation, insulation extending under the slab or insulation extending out from the building. Insulation extending away from the building shall be protected by pavement or by a minimum of 10 inches (254 mm) of soil. The top edge of the insulation installed between the exterior wall and the edge of the interior slab shall be permitted to be cut at a 45-degree (0.79 rad) angle away from the exterior wall. N1102.2.10 (R402.2.10) Crawl space walls. As an alternative to insulating floors over crawl spaces, crawl space walls shall be permitted to be insulated when the crawl space is not vented to the outside. Crawl space wall insulation shall be permanently fastened to the wall and extend downward from the floor to the finished grade level and then vertically and/or horizontally for at least an additional 24 inches (610 mm). Exposed earth in unvented crawl space foundations shall be covered with a continuous Class I vapor retarder in accordance with this code. All joints of the vapor retarder shall overlap by 6 inches (153 mm) and be sealed or taped. The edges of the vapor retarder shall extend at least 6 inches (153 mm) up the stem wall and shall be attached to the stem wall. N1102.2.11 (R402.2.11) Masonry veneer. Insulation shall not be required on the horizontal portion of the foundation that supports a masonry veneer. 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS5/2/2014 7:15:22 AM A3.1 DETAILS & ENERGY CODE 1354 LANDERS RENOVATION Permit Set 03-06-14 John & Debra Landers 1454W Greenhill Court Vail, CO 81658 1 1/2" = 1'-0" 1 EAVE 1 DETAIL 1" = 1'-0" 3 DETAIL - FOUNDATION 1" = 1'-0" 4 DETAIL - STEPPED FOUNDATION RAILING DETAIL: MATCH EXISTING METAL RAILING. MATCH STUCCO WALLS W/ STONE CAP. MATCH STONE, CAP, STUCCO, AND WINDOW DETAILS. AT ALL NEW ROOF CONSTRUCTION - R-49 MINIMUM INSULATION VALUE WITHIN 11 1/4" RAFTER SPACE. ARCHITECT RECOMMENDS 2" SPRAY FOAM R-14 AND 9 1/4" BLOWN-IN INSULATION R-37 FOR A TOTAL OF R-51. INSULATION SUMMARY ALL MINIMUM INSULATION VALUES FROM IRC 2012 ROOF RAFTERS = R-49 (MIN. R-51) EXTERIOR WALL INSULATION = R-22 (MIN. R-20) BASEMENT WALL INSULATION = R-19 (MIN. R-19) HEATED SLAB INSULATION = R-15 (MIN. R-15) WINDOWS U-VALUE MAX. = U-.32 (MAX. U-.32) INSULATION SUBCONTRACTOR MUST VERIFY THAT R-VALUES OF PROPRIETARY PRODUCTS MEET OR EXCEED THE R-VALUES LISTED ABOVE AND THAT INSTALLATION PERFORMED PER MANUFACTURER'S SPECIFICATIONS. ALL INSULATION SHALL COMPLETELY FILL STUD/JOIST SPACES AND HAVE PROPER AIR- BARRIER SHEATHING ON BOTH SIDES OF THE STUD/JOIST SPACES. No. Description Date 07/16/14