HomeMy WebLinkAbout140828 Lodge at Vail, Unit 516 - Fireplace Specifications.pdf H38DF PFC HL38DF PFC HP38DF PFC
Peninsula Indoor Residential Gas Fireplace
®
C US
Read and understand this manual. Improper installation, adjustment, alteration, service or maintenance can cause serious injury, property damage or even death. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
DANGER
Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain hot even after the fireplace has been turned off. Safety screens are available and can reduce the risks of severe burns. Please keep children away from the fireplace at all times.
CAUTION
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of this or any other gas burning appliance. A fire or explosion my occur causing serious injury, property damage or even death.
WARNING
Installer: Leave this manual with the appliance. Do not remove. Consumer: Retain this manual for maintenance and future reference. Do not Discard.
NOTICE
IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department.
DANGER
Irritant CuttingWatch your stepSlippery floor High temperatures Glass hazard Danger of suffocation
High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead craneExplosion risk
Oxidising Danger of death BiohazardLaser Radiation Danger of entrapmentHot surfaceGeneral Warning
Blank
Gas bottles Watch for falling objects Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts
Low temperature Strong magnetic field Optical radiation Non ionizing radiation Radiation Hazardous to theEnvironment Danger of harming your hands
Irritant CuttingWatch your stepSlippery floor High temperatures Glass hazard Danger of suffocation
High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead craneExplosion risk
Oxidising Danger of death BiohazardLaser Radiation Danger of entrapmentHot surfaceGeneral Warning
Blank
Gas bottles Watch for falling objects Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts
Low temperature Strong magnetic field Optical radiation Non ionizing radiation Radiation Hazardous to theEnvironment Danger of harming your hands
Irritant CuttingWatch your stepSlippery floor High temperatures Glass hazard Danger of suffocation
High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead craneExplosion risk
Oxidising Danger of death BiohazardLaser Radiation Danger of entrapmentHot surfaceGeneral Warning
Blank
Gas bottles Watch for falling objects Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts
Low temperature Strong magnetic field Optical radiation Non ionizing radiation Radiation Hazardous to theEnvironment Danger of harming your hands
Irritant CuttingWatch your stepSlippery floor High temperatures Glass hazard Danger of suffocation
High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead craneExplosion risk
Oxidising Danger of death BiohazardLaser Radiation Danger of entrapmentHot surfaceGeneral Warning
Blank
Gas bottles Watch for falling objects Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts
XG0816 011012.1
Installation & Maintenance Manual
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
Page 2
You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance.
NOTICE
Table of Contents
H*38DF PFC Peninsula Gas Fireplace
XG0816 - 011012.1
Safety Alert Key
Introduction .................................................................................3
Models .................................................................................3
Installation .................................................................................4
Before you Start .................................................................................4
Installation Checklist ...........................................................................4
Section 1: Installation Overview and Product Dimensions .....................5
Section 2: Framing the Fireplace ............................................................6
Clearances .................................................................................6
Installing the Standoffs ...................................................................7
The Nailing Flange Extension ........................................................7
Section 3: The Direct Vent System ..................................................8 - 10
Section 3-1: Converting from Top Vent to Rear Vent .............................8
Section 3-2: Installing a Roof mounted Termination .......................9 - 10
▪ Section 3-2-1: Venting Layout ......................................................9
▪ Roof mounted Terminations
Standard Top Vent (no elbows or offsets) ..................................9
Top Vent (two elbows one offset) ...............................................9
Top Vent (multi-elbows and offsets) ...........................................9
Standard Roof Vent (one elbows no offsets) ...........................10
Section 3-3: Installing a Wall mounted Termination .........................11
▪ Standard PTO Installation .....................................................11
▪ Pre-installed MSR Frame ......................................................11
▪ Pre-installed BSR Frame .......................................................11
▪ Installing MOSR Frame .........................................................11
▪ Installing VSS Termination Shield..........................................11
▪ Installing PTKOG Heat Guard ...............................................11
▪ Section 3-3-1: Venting Layout .............................................12 - 15
▪ Top Vent, Wall mounted Graph, H*38PF* ..............................12
▪ Top Vent, Wall mounted termination (one elbow) ..................12
▪ Top Vent, Wall mounted termination (multi elbow) ................13
▪ Rear Vent, Wall mounted Termination Graph, H*38PF* ........14
▪ Standard Rear Vent, (no elbows or offsets)...........................15
▪ Rear Vent, Wall mounted termination (two elbows) ...............15
▪ Section 3-3-2: Venting Components ..............................................16
▪ Section 3-3-3: Heat Shields ...........................................................17
▪ Installing a RHS8 Wall Mounted Heat Shield ........................17
▪ Installing a RHS101 Wall Mounted Heat Shield ....................17
Section 4: Wiring ...............................................................................18
▪ SIT - IPI gas control and pilot ................................................18
▪ Installing the remote On/Off Wall Switch ..........................18
▪ Honeywell gas control and pilot ...........................................18
Section 5: Installing the Gas Line .........................................................19
Section 5-1: Fuel Conversion ..........................................................19
Section 5-2: Gas Pressure ..............................................................19
Section 5-3: Gas Connection ...........................................................19
Section 6: Finishing ..............................................................................20
▪ Finishing around the fireplace ...............................................20
▪ Mantels and Surrounds .........................................................20
Section 7: Installing and Removing the Door .......................................21
Section 8: Installing the Accessories .............................................22 - 24
▪ Installing the H38PF* Log set ................................................22
▪ Installing the HL38PF* Firestones .........................................23
▪ Installing the HP38PF* Log set .............................................24
Section 9: Operation ......................................................................22 - 24
▪ Start-up Sequence for Standing (Continuous) Pilot Ignition ..25
▪ Start-up Sequence for Honeywell Electronic Ignition ...........26
▪ Start-up Sequence for Proflame SIT Electronic Ignition ........27
Maintenance ........................................................................28 - 30
▪ General ...............................................................................28
▪ Cleaning ...............................................................................28
▪ SIT Hi-Lo Burner Adjustment .................................................28
▪ SIT Pilot Burner Adjustment ..................................................28
▪ Troubleshooting .....................................................................29
SIT- Nova 820 Gas Control Valve ........................................29
SIT-Proflame Electronic Gas Control Valve .........................29
▪ Replacement Parts ................................................................30
Appendix
A. Termination Locations ..............................................................31
B. Warranty ...............................................................................32
C. State of Massachusetts. ..........................................................33
Page 3
Indicates a hazardous situation which, if not
avoided, WILL result in death or serious
injury or property damage.
Indicates a hazardous situation which, if not
avoided, COULD result in death or serious
injury or property damage.
Indicates a hazardous situation which, if not
avoided, WILL result in minor or moderate
injury.
Address practices that are important, but
not related to personal injury
DANGER WARNING
CAUTION NOTICE
H*38DF PFC Peninsula Gas Fireplace
Safety Alert Key
Introduction
XG0816 - 011012.1
INTRODUCTION
Congratulations on your purchase of a Montigo Fireplace.
With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your
space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
We strongly encourage you to read and carefully follow the
instructions laid out in this Installation, Operation and Maintenance Manual and retain it for your future reference. Pay special attention to all cautions, warnings, and notices throughout this manual intended to ensure your safety.
This manual covers installation, operation and maintenance. Lighting, operation and care of this fireplace can be easily performed by the homeowner. All installation and service work
should be performed by a qualified or licensed installer, plumber or gasfitter as certified by the state, province, region or governing body where the fireplace is being installed.
This installation, operation and maintenance manual is applicable to the models described below. Refer to your rating plate to verify included options. Throughout this manual instructions are applicable to all models designated as H*38PF* unless otherwise
noted in the Table.Warranty Information: (See Appendix B)
The Montigo warranty will be VOIDED by, and Montigo disclaims any responsibility for, the following actions:
► Modification of the fireplace and/or components including Direct-Vent assembly or glass doors.
► Use of any component part not manufactured or approved by Montigo in combination with this Montigo fireplace system.
► Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation requirements for factory-built gas fireplaces. Installation & repairs should be done by a qualified contractor.MODELNatural GasLiquid PropaneGas Rating(BTU hr)Traditional Burner w/ LogsetPremium Burner w/ LogsetLinear Burner w/ Glass media AccessoriesStanding Pilot IgnitionHoneywell HSI IgnitionSIT Electronic IgnitionH38DFPFCN X 34,000 X X
H38DFPFCN-F X 34,000 X X
H38DFPFCL X 32,000 X X
H38DFPFCL-F X 32,000 X X
HL38DFPFCN X 34,000 X X
HL38DFPFCN-F X 34,000 X X
HL38DFPFCL X 32,000 X X
HL38DFPFCL-F X 32,000 X X
HP38DFPFCN-F X 34,000 X X
HP38DFPFCL-F X 32,000 X X
WARNING
Hot glass will cause burns. Do not touch
glass until unit is cooled.
Never allow children to
touch glass.
Irritant CuttingWatch your stepSlippery floor High temperatures Glass hazard Danger of suffocation
High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead craneExplosion risk
Oxidising Danger of death BiohazardLaser Radiation Danger of entrapmentHot surfaceGeneral Warning
Blank
Gas bottles Watch for falling objects Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts
Low temperature Strong magnetic field Optical radiation Non ionizing radiation Radiation Hazardous to theEnvironment Danger of harming your hands
Page 4 XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Due to high operating temperatures, this appliance should be located out of traffic & away from furniture and draperies.
Children and adults should be alerted to the hazards of the high surface temperature, which could cause burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance.
Clothing or other flammable materials should not be placed on or near the appliance.
CAUTION
When this appliance is installed directly on any combustible material other than wood flooring, it must be installed on a metal or wood panel extending the full width and depth of the appliance or a fire will occur causing serious injury, property damage or even death.
DANGER
Installation Checklist
Determine the desired install location of your fireplace.
See Section 1, Dimensions on Page 5, and refer to the Framing Section 2 for details.
Select the location of your termination and resulting vent run.
Your selected termination location must be the highest point in the Direct Vent installation.
Should it be impossible to meet the venting requirements laid out in Section 3: Venting, please contact a local Montigo dealer regarding the use of a Montigo Power Vent.
Lay out the Vent run; calculating the required elbows and straight
runs of 5"/8" flex or rigid pipe.
Layout Electrical Requirements Refer to Section 4: Wiring for Details.
Refer to Section 5: Installing the Gas Line for details on the gas connection and access.
Refer to local codes and guidelines for installation requirements.
Installation and repairs should be done by a qualified contractor and must conform to:
• Installations in Canada must conform to the local codes or in the
absence of local codes to the current version of Natural Gas and Propane
Installation Code, CSA B149. Electrical Installations must conform to
the local codes or, in the absence of local codes, to the current version
of Canadian Electrical Code, CSA C22.1.1
• Installations in the USA must conform to the local codes or in the absence of local codes to the current version of National Fuel Gas Code, ANSI Z223.1/NFPA 54. Electrical Installations must conform to the local codes or, in the absence of local codes, to the current version of the National Electrical Code, ANSI/NFPA 70. See Appendix C for installation within the State of Massachusetts.
IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS
The H*38PF* Direct Vent fireplace must be installed in accordance with these Instructions. Carefully read all the Instructions in this manual first. Consult the Local Gas Branch to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with the manufacturers instructions and all applicable codes.
BEFORE YOU START:
Installation and repairs should be done by an authorized gas fireplace service technician. The appliance should be inspected before use and at least annually by a professional. More frequesnt cleaning may be required due to exessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the fireplace are kept clean.
NOTICE
Page 5XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Section 1: Installation Overview and Product Dimensions
Please review the Installation Checklist on Page 4 for general information on preparing for a successful installation of your fireplace.
The H*38PF* fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing.
Safety, as well as efficiency of operation, should be considered when
selecting the fireplace location. Select a location that does not interfere
with room traffic, has adequate ventilation and offers an accessible path
for Direct Vent installation.
Figure 1. Fireplace dimensions with Nailing Flange Extension shown (Tolerance ± ⅛").
The fireplace dimensions are shown below:
Front View Side View
Top View
12 1/2”
8 3/4”
41 1/2”
Ø 5”
Ø 8”
CL
CL
21 5/8”
Glass
4 1/2”4 1/2”32 1/8” Glass
6”
4 7/8”
4” Nailing Flange
33” Rear Vent
25”
35 5/8”
16 3/8”
2 15/16”2 15/16”19 1/8”
40”
Top of Unit 24 3/4”
Opening
Glass
39 5/8”
Page 6 XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Section 2: Framing
1). Frame in the enclosure for the unit with framing materials. The framed opening for the assembled fireplace is 23 3/4" wide, x 44" high x 41" deep, see Figure 2.
NOTE: When constructing the framed opening, please ensure there is access to install the gas line when the unit is installed. See Figure 21.
Figure 2. Framing dimensions.
Figure 3. Combustible Framing for shelves over the fireplace, Rear vent.
Figure 5. Non Combustible Framing with alcove above fireplace, Top Vent.
41
23 3/4
44
Figure 4. Combustible Framing for shelves over the fireplace, Top vent.
11”Min.
Combustible Shelf
33”
44”
ExteriorWall
Combustible Header
12” Max.
4” Nailing flange or Non-combustible material.
46” Min
17 1/2”
2” Min.
44”
Combustible ShelfCombustible Header
Min.
ExteriorWall
PEL Short90 elbow 4” Nailing flangeor Non-combustible material.
58” Min for HP
Floor
39 5/8” 44”
CombustibleHeader
Min. 1 ”
2”
Ceiling level
Non-Combustible Header
Non-Combustible materials. Alcoveover fireplace.
Top Vent
Non-Combustible Materials, with Low profile mantel / Alcove over fireplace.
84”min.
Page 7XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Clearances
When installing a shelf over the top of the fireplaces, the following guidelines must be adhered to:
For Rear Vent applications, the minimum clearance is 2" from the rear of the fireplace to a wall, or any combustible materials, and 11" clearance from the top of the fireplace to the underside of any combustible shelf materials.
For Top Vent applications, the minimum clearance is 2" from the rear of the fireplace to a wall, or any combustible materials, and 17 1/2" to the underside of any combustible shelf materials.
For Horizontal vent pipes, ensure that 1” clearance is maintained on sides and bottom of vent runs and 2” above horizontal vent runs to any combustible material.MODELTop - Rear vent †Top - Top vent †RearSidesFloorMantelH*38PF* 11" 17 1/2" 2" 1" 0" 4"
Installing The Standoffs
To avoid elevated mantel temperatures, all H*38PF*-Series gas fireplaces are required to have the supplied standoffs installed.
The fireplace is supplied with two standoffs. Bend and install these
standoffs on top of the fireplace ensuring that the height of the standoff
maintains a 8" clearance.
† Note: Clearance from top of fireplace to a combustible ceiling within the fireplace enclosure.
8”
Fasten Standoffs in gutter
Figure 6. Installing the standoff's.
Nailing Flange Extension
The 4" nailing flange extension is shipped attached to the top edge of
the fireplace, see Figure 1.
The nailing flange extension may be substituted with a piece of NON-Combustible material of the same thermal characteristics, ie: cement board or equivalent to fit the opening. This is recommended in applications where the facing materials will not adhere to the metal nailing flange. To remove the Nailing Flange Extension follow the directions below:
Figure 7c. Finished removing Nailing Flange extension.
Figure 7. Remove screws from top of the unit
Figure 7a. Remove shell and insulation from the top of unit. Remove screws
from outer edge.
Figure 7b. Remove the nailing flange extension from the unit. Reinstall shell
and insulation. Screw shell in place.
Page 8 XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Figure 8. Flue cover and collar removal, Top Vented fireplace.
Figure 8a. Flue cover and collar installation, Rear Vented fireplace.Section 3-1: CONVERTING TO REAR VENT
Use the following instructions to convert a H*38PF* for Rear Vent use:1. Remove the Rear flue cover and gasket (5" and 8") on the flue outlet, as shown in Figure 8.2. Next, Remove the Top flue collar's (5" and 8") on the flue outlet, as shown in Figure 8.
3. Install the (removed) Rear flue cover and gasket material, to the Top vent outlet. Fasten the cover with included hardware, as illustrated Figure 8a.4. Install the (5" and 8") collars to the rear vent outlet using the
included hardware, as illustrated Figure 8a.
Montigo supplies a variety of direct venting and termination options. The direct vent termination location MUST be selected such that it is the highest point in the venting assembly. It should also be selected such that it provides the shortest vent run possible. Should it be impossible to ensure that the termination is the highest point or should it be impossible to meet the venting guidelines laid out below please contact your Montigo dealer to discuss power venting options. NOTES FOR PLANNING VENTING:
Venting can originate from the unit through the top or through the rear
Venting can terminate through the roof or through an
exterior wall.
Refer to Appendix A - Termination Locations to ensure the planned termination location is acceptable.
Once the termination location has been established, refer to the appropriate section below for installation details
All fireplaces shipped from the factory are Top vent.
See Section 3-1 for converting the unit from top vent to rear vent.
5” Inner Flue
Cover Plate
8” Outer Flue
Cover Plate
8” Outer
Flue Collar
5” Inner
Flue Collar
Flue Collar
8” Outer
Flue Collar
5” Inner Flue
Cover Plate
Outer Flue
Outer Plate
Section 3: Venting
Page 9XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Section 3-2: INSTALLING A ROOF MOUNTED DIRECT VENT TERMINATION (PVTK-1)This section applies to installations where the direct vent termi-nation will be roof mounted.
Section 3-2-1: VENTING LAYOUTSelection of components and details of venting lay out should adhere to the following guidelines:
The maximum termination point is 32’ above the fireplace (NOTE: if the maximum termination height is used, the flame pattern may be affected).
The Vertical termination must be a minimum 2’ higher than where the termination exits the roofing materials, (asphalt shingles, cedar shakes, etc). This distance should be measured
from the high side of the roof slope where the flue flashing
intersects the roofing materials. (see Figures 9 - 9c).
For a detailed diagram of allowed termination locations, see Appendix A.
Termination location must be a minimum 6’ from a mechanical air inlet.
Termination location must be a minimum 18” from a parapet wall.
A maximum of two offsets (each offset is made up of 2-90° bends) may be made.
Firestops must be installed as required by National & local codes.
Ensure all runs are supported with a minimum of 3 supports
per 10’ of venting.
Install all roof flashing and storm collars as shown.
Figure 9. Top vent, Roof mounted termination with no offset in vent run.
Figure 9a. Top vent, Roof mounted with 1 offset (1 offset= two 90° bends).
Figure 9b. Top vent, Roof mounted with 2 offsets (1 offset= two 90° bends).
Roof mounted TerminationsThe following details are some possible configurations for Roof mounted terminations.
Support ring
Support plate
Firestop
32’ max.
2’ min.
PVTK1
Termination
Support straps or
support plate & ring
2’ min.
Firestop
Firestop
Firestop
32’ max Support plate
& ring
Obstacle
PVTK1
Termination
Support ring
Support plate
Firestop
32’ max.
2’ min.
Obstacle
PVTK1
Termination
Page 10 XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Figure 9c. Rear vent, Roof mounted venting (1 = 90° bend).
Support ring
Support plate32’ Ma.x
PVTK1
Termination
12” Max.
Page 11XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
1
12”
2”
12”
12”
Section 3-3: INSTALLING A WALL MOUNTED DIRECT VENT TERMINATION This section applies to installations where the direct vent termi-nation will be wall mounted.1). Installation of Termination with built in frame
A Termination with a Built-In Frame is installed during framing of a structure.
1. Frame the termination opening to 11" x 11".
2. Install exterior sheathing to the structure framing.
3. Fasten the termination to the sheathing using a minimum of 4 screws.
MSR Frame
PTO-4 (5"/8")
Termination
PTO-4F (5"/8")Termination
Figure 10. Installing a PTO-F termination.
Figure 10a. Installing a PTO termination with the MSR frame.
Figure 10d. Installing the VSS Vinyl Shield.
5). Installation of a termination shield for Vinyl Siding
The VSS Termination shield is installed when the exterior of a structure is clad with Vinyl siding. It is placed directly above, and on-center with the termination.
2). Installation of termination frame at time of framing
Terminations with a MSR frame allow the installation of the frame prior to installation of the termination.
1. Frame the termination opening to 12" x 12".
2. Secure the MSR Frame to the exterior sheathing of the structure.
3. Fasten the termination to the MSR Frame using a minimum of 4 screws.
Figure 10b. Installing a PTO termination with the BSR frame.
3). Installation of termination frame at time of framing in Masonry
Terminations with a BSR frame allow the installation of the frame in masonry prior to the installation of the termination
1. Frame the BSR opening to 12" x 12".
2. Secure the BSR Frame to the exterior sheathing of the structure.
3. Fasten the termination to the BSR Frame using a minimum of 4 screws.
1. Frame the MOSR opening to 12" x 12".
2. Fasten the MOSR frame to the interior side of the studs, concrete, or finished wall construction using a minimum of 4 screws.
3. Insert the termination into the MOSR frame as shown here, (from
the inside) and attach to the MOSR by installing a min. quantity of 4 bolts into the threaded nuts on the MOSR Frame.
4). Installation of termination from inside structure
A Termination with a MOSR Frame is installed from the inside of the structure. These are commonly used in high-rise construction.
MOSR Frame
PTO-4 (5"/8")
Termination
Figure 10c. Installing a PTO termination with the MOSR frame.
BSR Frame
PTKOG (5"/8")
Installing Heat Guards over Terminations is recommended in installations where the termination is located within 7' feet above
grade, or above a pedestrian walkway, and may be Required by code
in Public areas.
1. Ensure that the two long mounting brackets are facing the bottom of the termination. (See inset). This will provide more heat protection at the top of the termination, where temperatures are highest.
2. Attach to the faceplate of the termination using four sheet metal screws.
Figure 11. Installing a PTO termination heat guard.
11”
11”
Framing
Exterior
Sheathing
Fastening Hardware,
minimum 4-screws
Framing
Exterior
Sheathing
Fastening Hardware, minimum 4-screws
PTO-4 (5"/8")
Termination
Framing
Exterior
Sheathing
Fastening Hardware, minimum 4-screws
12”
12”
Fastening Hardware, minimum 4-screws
Framing, con-
crete or other
materials
Exterior Sheath-ing, concrete or other materials
Exterior Vinyl siding
PTO-4 (5"/8")
Termination
VSS Vinyl shield
Page 12 XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
The Venting Graph: H*38PF*
Measure the vertical height from the fireplace hearth to the centre of the termination and the horizontal run from the fireplace flue collar to the wall flange of the termination. Plot on the Venting Graph Figure 12 or 12a with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 114" and the horizontal run to the wall flange of the vent termination is 126", this would be an acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 48" and the horizontal run to the wall flange of the vent termination is 84", this would NOT be an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 60" and the horizontal run to the wall flange of the vent termination is 144", this would NOT be an acceptable installation.
Figure 12. H38PF* or HL38PF* Top Vent Venting Graph for wall mounted
terminations.
Figure 13. H38PF* or HL38PF* Top Vented, wall mounted installation with one 90° bend. The vent run must comply with Venting Graph for Top vent, wall mounted terminations, Figure 12.
Section 3-3-1: VENTING LAYOUT: Wall mounted termination.
Selection of components and details of venting layout should adhere to the following guidelines: Vent terminations must not be recessed in walls or siding.
For Heat Shield requirements see Section 3-3-3.
Once the proposed venting layout has been determined refer to Figure 12, 12a,14, or 14a to ensure the layout is acceptable.
Notes Wall Mounted Terminations: TOP VENT
All measurements for vertical or horizontal runs are measured from center of the vent pipe.
Venting runs must fall within the limits set by the venting graph, see Figure 12 or 12a.
Figure 12a. HP38PF* Top Vent Venting Graph for wall mounted terminations.
58”
A
C
B
.
Unacceptable vent runwithin shaded area.
Acceptable vent runwithin non-shaded area.
If your installation does not fall with- in the venting graph parameters, please contact a local Montigo dealer for Power Venting options.
19”
42”
46”
A
C
B
If your installation does not fall with- in the venting graph parameters, please contact a local Montigo dealer for Power Venting options.
Unacceptable vent run within shaded area.
Acceptable vent run within non-shaded area.
Figure 13a. HP38PF* Top Vented, wall mounted installation with one 90° bend. The vent run must comply with Venting Graph for Top vent, wall mounted
terminations, Figure 12a.
Heat Shield
Termination
ExteriorWallHearth
Flex or RigidInsulated Sleeve CRS101
19” Max
58”Min.
Heat Shield
46”Min.
Termination
ExteriorWallHearth
Flex or RigidInsulated Sleeve CRS101
42” Max.
Page 13XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Figure 13b. H38PF* , HL38PF* or HP38PF* Top Vented, wall mounted Multi-
elbow installation. See Venting Graph for Top vent, wall mounted terminations, Figure 12 or 12a.
WARNING:
An inspection of the explosion relief flappers and door
MUST be made prior to lighting the fireplace. A faulty seal
on the door gasket and/or explosion ports will result in
products of combustion leaking into the living space and
may result in carbon monoxide poisoning.
Solid
Section
Flex
Section
Hearth
150” Max. HeatShield
Termination
Exterior
Wall
HeatShield
Termination
Exterior
Wall
30” Max.
126” Max.
Solid
SectionFlex
Section
Hearth
Figure 13b. H38PF* , HL38PF* or HP38PF* Top Vented, wall mounted Retracted
Multi-elbow installation. See Venting Graph for Top vent, wall mounted terminations, Figure 12 or 12a.
Page 14 XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Figure 14a. HP38PF* Rear Vent Venting Graph for wall mounted terminations.
Figure 14. H38PF* or HL38PF* Rear Vent Venting Graph for wall mounted
terminations.
Notes Wall Mounted Terminations: REAR VENT
All dimension lengths for vertical or horizontal runs are measured from center of the vent pipe.
Venting runs must fall within the limits set by the venting graphs, see Figure 14 or 14a.
Fireplace must be converted to Rear Vent configuration prior to running vent, see Figure 8 and 8a.
The Venting Graph
Measure the vertical height from the fireplace hearth to the centre of the termination and the horizontal run from the fireplace flue collar to the wall flange of the termination. Plot on the Venting Graph Figure 14 or 14a with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 120" and the horizontal run to the wall flange of the vent termination is 138", this would be an acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 60." and the horizontal
run to the wall flange of the vent termination is 84", this would NOT be an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 72" and the horizontal run to the wall flange of the vent termination is 120",
this would NOT be an acceptable installation.
53”
42”
33”
12”
B
C
A
Unacceptable vent run within shaded area.
Acceptable vent run within non-shaded area.
If your installation does not fall within
the venting graph parameters, please contact a local Montigo dealer forPower Venting options.
Figure 15. H38PF* , HL38PF* or HP38PF* Straight run, Rear Vented, wall mounted termination. The vent run must comply with the Venting Graph for Rear vent, wall mounted terminations, Figure 14 or 14a.
Hearth
12”MAX.
Heat
Shield
Termination
Exterior
Wall
33”
NOTE: 12” MAX.horizontal run with no vertical lift.
42”
60”
A
C
B
Acceptable vent runwithin non-shaded area.
Unacceptable vent runwithin shaded area.
12”
33”If your installation does not fall within the venting graph parameters, please
contact a local Montigo dealer forPower Venting options.
Page 15XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Figure 15a. HP38PF* Rear Vented, wall mounted Multi-elbow termination installation. The vent run must comply with the Venting Graph for Rear vent, wall mounted terminations, Figure 14a.
WARNING:
An inspection of the explosion relief flappers and door
MUST be made prior to lighting the fireplace. A faulty seal
on the door gasket and/or explosion ports will result in
products of combustion leaking into the living space and
may result in carbon monoxide poisoning.
42” Max.
60” Min. 12” Max.
27”Min.
33”
Hearth
Flex or RigidSection
Figure 15a. H38PF* or HL38PF* Rear Vented, wall mounted Multi-elbow termination installation. The vent run must comply with the Venting Graph for Rear vent, wall mounted terminations, Figure 14.
42” Max.
53” Min. 12” Max.
20”Min.
33”
Hearth
Flex or RigidSection
Page 16 XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Connection and installation of the vent components should
adhere to the following guidelines:
Section 3-3-2: VENTING COMPONENTS
The following components and associated Montigo part numbers for installation of a roof or wall mounted termination. Use only Montigo Vent Components. Use of non-Montigo parts will VOID the warranty and may impede operation of the fireplace..
A - Termination PTO-4 (3" Length)PTO-4F (3" Length)PVTK-1
B - Frame Kits MSR (Stucco Frame)MOSR (Stucco Frame)BSR-4 (4" Brick Frame)BSR-6 (6" Brick Frame)
C - Flex Sections PFL - 1 (12" f/f Section)PFL - 18 (18" f/f Section)PFL - 2 (24" f/f Section)PFL - 3 (36" f/f Section)PFL - 4 (48" f/f Section)PFL - 6 (72" f/f Section)
D - Rigid Sections PXT - 5 (5" f/f Section)PXT - 10 (10" f/f Section)PXT - 20 (20" f/f Section) PEXT - 1 (12" f/m Section)PEXT - 2 (24" f/m Section)PEXT - 3 (36" f/m Section)PEXT - 4 (48" f/m Section)PEXT - 6 (72" f/m Section)
E - Elbows PEL-90MM (m/m 90º Elbow)PEL-90FF ( f/f 90º Elbow)PEL-90FM ( f/m 90º Elbow)PEL-45FM ( f/m 45º Elbow)
F - Support Ring & Plate PSPXT-8
G - Firestop FS-8
H - Roof Flashing PRF-7 (1/12 - 7/12 pt.)PRF-12 (7/12 - 12/12 pt.)
I - Heat Shield RHS101
J - Heat Guard PTKOG
IMPORTANT:
Please Refer to your Building Envelope Engineer
or Waterproofing Consultant for a review of ALL penetrations through exterior walls or the roof.
Montigo recommends the use of a flex section for the final pipe connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
Firestops must be installed as required by National & local codes.
Montigo recommends that all exterior corners and joints be sealed
with exterior caulking. However, we encourage you to consult
your Building Envelope Engineer or Waterproofing Consultant
for further recommendations.
Use any combination of rigid and flex pipe as required and in any orientation (Male connectors can face in any direction).
Flex sections may be stretched up to 50% of their total length (e.g. a 24” section maybe stretched to 36”).
Connect all vent sections using a minimum of three sheet metal screws on the outer pipe flue.
Ensure the pipe ends male to female slide in a minimum of 1 1/2” of overlap.
Ensure all runs are supported with a minimum of 3 supports per 10’ of venting.
When hanging/ supporting venting, ensure that 1” clearance is maintained on sides and bottom of vent runs and 2” above horizontal vent runs to any combustible material.
Rigid pipe may be cut less than half way from the female end only.
Ensure when cutting sections of rigid pipe to maintain integrity of internal supports.
Place the springs, supplied with the pipe kit, between the outer and inner pipes to keep the pipes separate and avoid any possible hot spots.
Page 17XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Figure 16. RHS8 Installation. (Install by sliding over vent pipe where it passes through the combustible construction).Figure 17. RHS101 Installation. (Install by sliding Outer Section over vent pipe where it passes through the combustible construction.
Figure 17a. Heat Shield. After sliding the outer section in place.
Figure 16a. Minimum requirements for RHS8
Section 3-3-3: Heat Shields
Installing a Wall Mounted RHS8 Heat shield
The RHS8 Heat shield CANNOT be used WITHIN 36" horizontal or 60" vertically of the fireplace, (see figure 16a). For applications within these dimensions the RHS101 Heat Shield MUST be used. .
To install the RHS8, frame an opening in combustible construction, Figure 16 below. Slide the Heat shield in place over the vent pipe
which attaches to the fireplace. After the fireplace and vent pipe has
been installed, clearances should match the dimensions in Figure 16.
Installing a Wall Mounted RHS101 Heat shield.
The RHS101 Heat shield MUST be used where the RHS8 Termination (Figure 16 and 16a) CANNOT be used. Use the RHS101 within 36" horizontal or 60" vertical.
To install the RHS101, Slide the Inner Section over the vent pipe that will connect to the fireplace. Fasten the vent pipe to the back of the fireplace with a Min. of three sheet metal screws.
Next, slide the RHS101 outer section from the outside of the structure, see Figure 17.
To complete the installation fasten the Heat Shield Outer Section & Termination frame to the structure Figure 17a.
RHS8 Heat Shield
1” Min. Both sides Typical
1” Min.
1” Min.Combustible Framing
Figure 17b. RHS101 Installation.
Outer Shield 10 1/4”
3/8” Min. Both sides Typical
3/8” Min.
3/8” Min .Combustible Framing 12” x 12”
Inner Shield 9 3/8”
RHS8 HeatShield
36” Min
60” Min.
Termination
Termination
Drywall / sheetrock
RHS101 Heat Shield, inner Section
RHS101 Heat Shield
Outer Section
Combustibleframing
Termination
Drywall / sheetrock
RHS101 Heat Shield, inner Section
RHS101 Heat Shield Outer Section
Vent pipe, from fireplace
Page 18 XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Section 4: Wiring
Models Included
H38DFPFCN-F HL38DFPFCN-F HP38DFPFCN-F
H38DFPFCL-F HL38DFPFCL-F HP38DFPFCL-F
Figure 18. Wiring Diagram for the SIT Proflame Electronic Ignition with remote control
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Junction Box
115VAC
24VAC
40VA
Transformer
Black
White
Green
Gnd Screw
Wall Switch
Fan Plug
Receptacle
Figure 20. Wiring with Honeywell gas control and pilot.
REMOTE
Receiver 14 Pin Connector
Pilot
(CPI / IPI MODEMOTORIPI/CPI
RECEIVER SPLIT FLOW
ON / OFFTHTPTHDC SUPPLYGROUND
885 Valve
Orange Green
Chassis
connection
Remote control
Not Used)
Battery
Holder
4 x 1.5V
AA Type
120 Vac INPUT 7.5V DC
Output AC AdaptorReceiver 14Battery Holder
w/ SwitchON/REMONTE/OFF
(Not Used)
Receiver 14Battery Holder
Top View
Installing the remote On/Off Wall Switch
The H38PF* gas valve may be connected to a wall switch. Do NOT connect any external power to the remote switch. The valve will generate its own power on a millivolt circuit Use only low voltage wire, and NOTE: The switch location must not exceed 30' from the fireplace.
Figure 19. Wiring with SIT Nova 820.
Models Included
H38DFPFCN
H38DFPFCL
HL38DFPFCN
HL38DFPFCL
Manifold PressureTest Connection
Wall Switch
Power GeneratorPilot Adjustment Screw
Inlet Pressure
'Hi-Lo' Adjustment Knob
Gas Control Knob (Shown in “Pilot” position)
Models Included
H38DFPFCN-I
H38DFPFCL-I
HL38DFPFCN-I
HL38DFPFCL-I
NOTE: If any of the original wire supplied with the appliance is replaced,
it must be replaced with the same type, or its equivalent.
Page 19XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Section 5-1: FUEL CONVERSION
Verify that your fireplace is compatible with your available gas type. (Natural Gas or Propane shown by "N" or "L" in your model number
If gas type is not compatible, contact your local Montigo representative to purchase a conversion kit.
Conversion kits must be installed by a qualified service technician.
Section 5-2: GAS PRESSURE
Optimum appliance performance requires proper input pressures.
Gas line sizing requirements will be determined in ANSI Z223.1 National Fuel Gas Code in the USA and CAN/CGA B149 in Canada.
Pressure requirements are:
Gas Pressure Natural Gas Propane
Minimum inlet pressure 5.5in. w.c. 11in. w.c.
Manifold pressure 3.5in. w.c. 10in. w.c.
The manifold outlet pressure is set from the factory to the appropriate pressure but should be verified.
To check pressures, control valves have a provision to remove
a 1/8” N.PT. plug to be fitted with a hose barb.
Montigo requires a service shut off valve be located in an accessible location to isolate the gas supply.
Only install gas shut-off valves approved for use by the state, province, or other governing body in which the fireplace is being installed.
Section 5-3: GAS CONNECTION
See Figure 21 for location of gas line access.
Flexible gas connectors must not exceed 3 feet in length, unless
allowable within local regulations.
Connect incoming gas line to the 1/2"or 3/8" gas inlet port.
Purge all air out of gas line.
Check appliance connection, valve and valve train under normal
operating pressure with a commercially available leak check
solution.
DO NOT USE A FLAME OF ANY KIND TO TEST FOR LEAKS.
Figure 21. Gas line access.
3”
Gasline Access
7/8”dia hole
Electrical
Access 2”x 3”
6 1/2”
Section 5: Installing the Gas Line
We recommend careful consideration be given to the effects of elevated mantel temperatures which may be in excess of product design, for example: candles, plastic or pictures. This can cause melting, deformation, discoloration or premature failure of T.V. radio, and other electronic components.
CAUTION
When pressure testing the fireplace, Gas line, and input system follow the appropriate local codes or your area. DO NOT connect the fireplace to pressures in excess of 1/2lb. This will damage the gas control valve.
NOTICE
Page 20 XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the top and on the front of the fireplace provided that they do not project beyond shaded area shown in Figure 22.
Fireplace Facing
When sizing the finish material for your fireplace, it is important to remember the following: THE OPENING MUST NOT BE OBSTRUCTED IN ANY WAY - to do so restricts the air supply for the control compartments and heat exchanger it also prevents access for servicing controls.
The face of the fireplace may be painted to match the room decor, provided you use a heat-resistant paint. Decorative facing must not extend past the fireplace opening at all, because it will interfere with the access to retainers for removal of glass door.
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible materials.
Side wall clearances are 3". Combustible surrounds may be installed with 3" clearance to the side of the fireplace.
Do not operate this fireplace without the glass door or with a broken glass door.
NOTICE
Do not use ammonia based or abrasive cleaners on the glass, they will permanently etch the surface. Use an approved gas fireplace glass cleaner such as Kel-Kem or White off.
NOTICE
When covering the upper metal portion of the fireplace, (as shown, Fig.21) with a non-combustible material, Please Note: The decorative facing materials may be subject to temperatures in excess of 250° F. This should
be considered when selecting facing materials.
CAUTION
WARNING!
We recommend careful consideration be given to the effects of elevated mantel temperatures which may be in excess of product design, for example: candles, plastic or pictures. This can cause melting, deformation, discolouration or premature failure of T.V. radio, and other electronic components.
WARNING!
When covering the upper metal portion of the fireplace, up to 4" (as shown, Fig.22) with a non-combustible material Please Note: The decorative facing materials may be subject to temperatures in excess of 250° F. This should be considered when selecting facing materials.
Header
Drywall/
Sheetrock
4” Nailing
Flange
3”
Combustible
Construction allowed
in shaded area
Top of fireplace
4” Nailing flange
Combustible Facing
Material
Horizontal Run (in)Vertical Run (in)Steel Stud construction
allowable within grey area
Figure 22. Combustible mantels and facings.
Figure 23. Combustible surrounds.
Page 21XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Removing the door:
The H*38PF* doors are removed in a few simple steps. Follow these instructions below to remove the Horizontal access panel, unlatch the door buckles and, remove the door. Replace in reverse order.
Figure 24a. Locate the door buckles. (Both Sides Typical)
Figure 24. Removing and installing the Horizontal Access Panel
Locate the Door Buckles:Step 2:
Step 1:
Remove the Horizontal cover by placing fingers in both finger holes, then pushing away from you and lifting out. Place it aside during maintenance or cleaning. Install in reverse order.
Remove the Horizontal Access Panel:
To install the door, hook the top edge of the door frame into place. Lower the door into position and follow the previous steps shown in reverse order.
Installing the Door:
2
Step 5:Ensure the tool is firmly in the lower end of the slot, (as shown), Then pull toward you (Caution: hold the tool securely).
3
Step 6:Pull hard if necessary to release the spring ten-sion. (Caution: The latch springs back with force, hold the tool securely).
4
Step 7:Remove the tool from the latch slot. Ensure the latches are hanging freely, the hook end is released from the bottom of the door. (Repeat all 4-steps for the remaining latches).
Figure 24d.
Figure 24e.
Figure 24f.
Step 8:
Grasp the Door on either side, usually midway and lift upward, lift the door carefully up and away from the front of the fireplace. See Figures 24g. Place the Door aside in a safe place while maintenance and / or cleaning is being performed.
Figure 24g. Removing and installing the glass doors. (Both Sides Typical)
Removing the Door:Front View
FixedPanel
Door buckles
Small glass dooraffixed to framewith hardware.
Door Latch Hook
Door Latch SlotHand-hold
Release the Door Buckles
Figure 24b. Door buckle Tool
1
Step 4:Firmly grasp hand-hold end of Door buckle tool and place the machined end in the slot under door frame. (as shown)
Figure 24c.
Step 3:
Finger Holes
Installed Gas
Valve Cover
Section 7: Installing & Removing the Door
Page 22 XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Section 8: Installing the Accessories
Figure 25a. Place Logs' "A" on Left & Right stands.
Installing the H38PF* Logset
The H38PF* is supplied with eight (8) fibre logs. The two small bottom logs ("A" ) are mounted on the burner grate by placing them diagonally onto the supplied Log stands. The long Front / Back logs ("B") are placed against the grate as shown in Figure 25b. Note: When placing logs, arrange Logs "B" as not to cover Burner holes.
Next are the Top logs "C" which are placed diagonally, as shown in Figure 25c. The last logs "D" is then mounted on top of logs "A" as shown in Figure 25d.
Installing the Ember Material
The ember material is supplied in two packages. Spread the material evenly around the burner tray, or pile around burner holes for a realistic effect.
Figure 25c. Log Installation. Place Logs' "C" on-top of Logs "A".
Indentations on-top of Logs' "A"
Figure 25b. Place Logs' "B" as shown, in front of Right-hand "A",
and behind Left-hand "B".
Log A
Log B
Log C
Log A
Log C
Figure 25d. Completed Installation.
Figure 25. Empty firebox showing the Left & Right stands.
Front of Fireplace
Burners
Log Stand
Log Stand
Burner holes (front & back burner),note hole pattern when placing logs
Air Inlets
If logs are not placed properly, excessive sooting will result.
NOTICE
Do not use ammonia based or abrasive cleaners on the glass, they will permanently etch the surface. Use an approved gas fireplace glass cleaner such as Kel-Kem or White off.
NOTICE
Do not operate this fireplace without the glass door or with a broken glass door.
NOTICE
Log D
Log B
Log D
Page 23XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Installing the HP38PF* Logs and Embers
Bottom Logs
The HP38PF* is supplied with seven (7) fibre logs. The two bottom logs ("A" & "B") are mounted on the burner grate as shown in Figure 26a.
Top Logs
Place logs "C" & "D" into their diagonal positions as shown in Figure 26b. Log "E" is mounted on top of log 'C" as shown in Figure 26c. Place
log "F" into slot at the side of the unit as seen in Figure 26d. Log "G" is
to be mounted onto of log "D" as shown in Figure 26e.
Installing the Ember Material
Figure 26a. Place Log A and B in the grate on either side of the burner.
Log A
Log B
Log DLog C
Figure 26b. Place Log C and D diagonally across Logs A and B.
Figure 26c. Place Log E diagonally across Log C.
Ensure that log E does not touch the grate.
Log E
Figure 26d. Place log F into slot at the side of unit.
Log F
Figure 26e. Place log G diagonally across log D. Log placement complete.
Log G
Figure 26g. Evenly spread provided lava rock in tray
Figure 26. Place the provided embers in the 5 pronged ember holders.
Be sure to not directly cover any of the burner holes.
* Do NOT cover burner with embers on the side facing the side view glass
See Figure 1 for Side View
*
Log F
Log G
If logs are not placed properly, excessive sooting will result.
NOTICE
Page 24 XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Optional Cultured Rocks
The HL38PF* has the option of installing the cultured rocks which mimic
real stone. These may be spaced at random or in a visual pattern of your
preference in the burner pan. See the Montigo web site for photographs
and ideas. www.montigo.com
Installing Optional Burner Cover kit and Firestones in
Natural Gas Fireplaces
The HL38PFN* has the option of a burner cover kit. To install the
firestones with the burner cover kit, remove the Door as shown on page 21. Follow these instructions to ensure all parts are removed or replaced
as required. Once the glass door is removed place the burner covers
and place firestones randomly across the pan and the burner covers as
described in Figure 28 to 28b.
Figure 28. Installation of the Optional burner covers ,
(Place the covers end to end; do not overlap).
Fill pan with firestones.
Figure 28a. Ensure ONLY one layer of firestones cover the burner and no firestones cover the pilot.
Figure 28b. Spread the firestones evenly .
Installing Firestones in Natural Gas and Propane Fireplaces
The HL38PF* fireplace is supplied with firestones. Remove the Door as shown on page 21. Follow these instructions to ensure all parts are removed or replaced as required. Once the glass door is removed place the firestones randomly across the pan as described in Figure 27 to 27a.
.
Figure 27. Completed firestone installation.
(Note: DO NOT place ANY firestones on top of the burners or pilot).
Figure 27a. Operating gas fireplace with firestones surrounding burner tray.
CAUTION!
DO NOT COVER THE BURNERS or PILOT CAUTION!
Only Natural Gas models have the option of installing a burner cover kit. Only conceal burner covers with one layer of firestones, or excessive sooting may result.
Ensure the firestones DO NOT COVER PILOT.
The firestones will get hot while fireplace is in operation and should not be handled until cool.
Page 25
H*38DF PFC Peninsula Gas Fireplace
XG0816 - 011012.1
Operation
Section 9: Start up Sequence
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the Fire Department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
don't try to repair it, call a qualified service technician. Force
or attempt to repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system, and
any gas control which has been under water.
A. This appliance has a pilot which must be lit by hand. When
lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
What To Do If You Smell Gas: Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
To Turn Off Gas To Appliance:
3. Push in gas control knob slightly and turn clockwise to "Off". Do not force.
4. Replace the lower Horizontal access panel.
1. Turn off remote switch.
2. Lift out the lower Horizontal access panel.
with American Flame Electronic IgnitionFor Your Safety - READ BEFORE LIGHTING:
Lighting Instructions:
1. STOP! Read the safety information above on this label.
2. Lift out the lower Horizontal access panel.
3. Push in gas control knob and turn clockwise to "OFF."
4. Wait five (5) minutes to clear out any gas. Smell for gas,
including near the floor. If you then smell gas, STOP! Follow
"B" in the safety information above on this label. If you don't
smell gas, go to the next step.
5. Locate pilot burner (See illustration at right.) and follow steps
below.
6. Turn knob on gas control counter clockwise to "PILOT."
7. Push in gas control knob completely and hold. Light with Piezo
Igniter button. Continue to hold the control knob in for about
(1) minute after the pilot is lit. Release the knob and it will pop
back up. Pilot should remain lit. If it goes out repeat steps 3
through 8. If knob does not pop up when released. Stop and immediately call your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.
8. Push in gas control knob and turn counter-clockwise to
"ON."
9. Replace the lower Horizontal access panel.
10. Turn on remote switch to ignite fire.
NOTE: Gas control knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.
If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
WARNING
Standing (Continuous) Pilot Ignition (SIT NOVA 820)
Page 26
H*38DF PFC Peninsula Gas Fireplace
XG0816 - 011012.1
Operation
To Turn Off Gas To Appliance:
1. Turn off remote switch.
2. Remove the lower Horizontal access panel.
3. Turn the incoming gas control valve to "Off".
4. Replace the lower Horizontal access panel.
with American Flame Electronic IgnitionFor Your Safety - READ BEFORE LIGHTING:
SIT Proflame Electronic Ignition
Lighting Instructions:
If you cannot reach your gas supplier, call the Fire Department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by
hand, don't try to repair it, call a qualified service technician. Force or attempt to repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system, and any gas control which has been under water.
A. This appliance is equipped with an ignition system that lights the pilot burner automatically. Do not attempt to light the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
What To Do If You Smell Gas: Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.
1. STOP! Read the safety information above on this label.
2. Remove the lower Horizontal access panel.
3. Turn Incoming gas valve to the ON" position.
4. Wait 5 minutes to clear out any gas. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.
5. Turn wall switch "ON".
6. If the Fireplace does not light, the System will cycle through two trials, (one minute audible clicking, thirty seconds of silence, and then another one minute of audible clicking).
7. After completion of the information in the Troubleshooting section, Repeat step 5.
8. If the system will not function correctly, follow the instruc-tions "To Turn Off Gas To Appliance" and call your service technician or gas supplier.
If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
WARNING
Lockout Reset Key
Diagnostic Terminal
Power
Command (Wall switch)
Pilot Sensor
IgniterGroundEV1 (Pilot burner)EV2 (Main burner)
EV1 (Pilot burner)
EV2 (Main burner)
Pilot Adjust Screw
Gas "Out"Gas "In"
Incoming GasLine, Shut-off Valve
To fireplace Main burner
Page 27
H*38DF PFC Peninsula Gas Fireplace
XG0816 - 011012.1
Operation
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the Fire Department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don't try to repair it, call a qualified service technician.
Force or attempt to repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system,
and any gas control which has been under water.
A. This appliance is equipped with an ignition system that
lights the pilot burner automatically. Do not attempt to light
the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
What To Do If You Smell Gas: Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
1. Turn off remote switch.
2. Flip down the lower trim.
3. Turn the switch on the gas control to "Off".
4. Flip up the trim.
1. STOP! Read the safety information above on this label.
2. Lift out the lower Horizontal access panel.
3. Turn switch on the gas control to OFF".
4. Wait 5 minutes to clear out any gas. If you smell gas,
STOP! Follow "B" in the safety information above on this
label. If you don't smell gas, go to the next step.
5. Turn switch on the gas control to "ON". NOTE: This unit is
equipped with an ignition system that lights the pilot burner
automatically. Do not attempt to light the pilot by hand.
6. Turn on wall switch.
7. Replace the lower Horizontal access panel.
8. If the fireplace does not operate, follow the instructions "To
Turn Off Gas To Appliance" and call your service technician
or gas supplier.
Honeywell Electronic Ignition
with American Flame Electronic IgnitionFor Your Safety - READ BEFORE LIGHTING:
To Turn Off Gas To Appliance:
Lighting Instructions:
If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
WARNING
Gas Control Switch
Shown in ‘ON’ Position
Gas
Inlet
Page 28
H*38DF PFC Peninsula Gas Fireplace
XG0816 - 011012.1
Maintenance
Lighting Instructions
See pages 25 to 27.
Due to high operating temperatures, this appliance should be located out of traffic & away from furniture and draperies.Children and adults should be alerted to the hazards of the high surface temperature, which could cause burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance.Clothing or other flammable materials should not be placed on or near the appliance.
CAUTION
General
Have the fireplace and installation inspected yearly. The inspection must include, but is not limited to, the following:
• A visual check of the entire vent system and termination.• An inspection of the explosion relief flappers and the door gaskets to ensure a proper seal. • An inspection of the burner, vent run, and primary air openings.• An inspection of the gas valve, gas components, and pilot flame. For your convenience a 1/8" manifold pressure tap is supplied on the gas valve for a test gauge connection.• Ensure proper log placement as per this manual.• Inspection of all optional equipment; fans, thermostats, etc. For Natural Gas this appliance requires a minimum inlet pressure of 5.5" W.C. and a manifold pressure of 3.5" W.C.
For Propane Gas this appliance requires a minimum inlet pressure of 11" W.C. and a manifold pressure of 10" W.C.
Always keep the fireplace area clear and free of combustible materials, as well as gasoline and other flammable vapours and liquids.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Cleaning
When the fireplace is first activated, there may be some smoking and a visible film may be left on the glass. This is a normal condition, and is the result of burning of protective coatings on new metal.
Glass must be cleaned periodically to remove any film (which is a normal by-product of combustion) which may be visible. Film can easily be removed by removing the door, as shown on Page 21. Handle the door carefully, and clean it with nonabrasive glass cleaners. One of the most effective products is Kel Kem.
Silicone seals on inner door during initial firing will "off gas", leaving a visual deposit of a white substance on combustion chamber walls. This can easily be removed from the chamber walls using normal household products.
Use a vacuum cleaner or whisk broom to keep the control compartment, burner, and firebox free from dust and lint.
Logs may be cleaned periodically with a vacuum to remove soot or other contaminates.
Hi-Lo Burner Adjustment: (SIT Nova 820).
The H*38PF* is equipped with an adjustable burner, allowing you to raise or lower the flames. To adjust the flames, locate the black knob marked 'Hi-Lo', in the centre of the gas control valve (See Figure 29).
To raise the flame height, turn the black knob (located behind the lower control compartment) counter-clockwise.
To lower the flame height, turn clockwise.
Figure 29. 'Hi-Lo' Adjustment on the SIT Nova 820 gas valve,
Pilot Burner Adjustment.
1. Locate Pilot Adjustment Screw. (See figure 29.)
2. Adjust pilot screw to provide properly sized flame as shown.
3. After installing or servicing, leak test with a soap solution with main burner on. Coat pipe and tubing joints, gasket etc. with soap solution. Bubbles indicate leaks. Tighten any areas where the bubbles appear until the bubbling stops completely.
Manifold PressureTest Connection
Wall Switch
Power GeneratorPilot Adjustment Screw
Inlet Pressure
'Hi-Lo' Adjustment Knob
Gas Control Knob (Shown in “Pilot” position)
Page 29
H*38DF PFC Peninsula Gas Fireplace
XG0816 - 011012.1
Maintenance
SIT Proflame
The following is a troubleshooting chart of possible problems:
Troubleshooting
SIT Nova 820
The following is a troubleshooting chart of possible problems:
PROBLEM CORRECTIVE ACTION
Noisy Pilot Flame Locate pilot adjustment screw on gas control valve. Flame is decreased by turning adjustment screw clockwise.
Pilot won’t ignite Disconnect remote wires and try to light pilot. If pilot now works, remote connections are faulty. Check wiring diagram figure 29.
Main burner will 1. Check wiring (see figure 29). not light 2. Check wall switch for proper connection.
PROBLEM SOLUTION
Pilot won't ignite or spark. - Check the on the batteries on the remote or the receiver.
- Check the green LED on AC adaptor
-Check the green ground wire under the valve
Main burner will not light. - Check the wiring on the valve as per diagram Fig 18
Honeywell Electronic Ignition
The following is a troubleshooting chart of possible problems:
If your fireplace still does not operate correctly, consult your local Montigo dealer.
All service and repairs should be performed by a qualified Technician.
All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer.
Page 30
H*38DF PFC Peninsula Gas Fireplace
XG0816 - 011012.1
Replacement Parts
H38PF* HL38PF* HP38PF*
NG Gas Valve RGC1006 RGC1006 RGC1006
LP Gas Valve RGC1005 RGC1005 RGC1005
NG Pilot RPA020 RPA020 RPA020
LP Pilot RPA021 RPA021 RPA021
NG Burner Contact Local Montigo Dealer
LP Burner
NG Orifice R0R1120 ~
LP Orifice R0R1121 ~
Door RDTH38 RDTH38
Log Base RLGSH38B ~
Log Set RLGSH38 ~
Page 31XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Appendix
Appendix A: Venting Terminations
Location Canada*USA**
A clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches
B clearance to top of doors or operable windows 12 inches 12 inches
C clearance to sides or bottom of door or operable windows 9 inches 12 inches
D clearance to permanently closed window when installed with approved gas penetration termination 0 0
E clearance to permanently closed window Recommended to prevent condensation 16 inches 16 inches
F clearance to ventilated soffit located within a horizontal distance to 24 inches from centerline
of termination
22 inches 22 inches
G clearance to unventilated soffit 30 inches to combustibles16 inches to non-combustibles 30 inches to combustibles16 inches to non-combustibles
H clearance to outside corner 9 inches 9 inches
I clearance to inside corner 12 inches 12 inches
J clearance to each side of the vertical centerline of a metre or regulatory assembly to a maximum vertical distance of 15ft 3 feet 3 feet
K clearance to service regulator vent outlet 3 feet 3 feet
L clearance to non mechanical air supply inlet to the building or combustion air inlet to other
appliance for appliance <= 100.000 BTU/H (30 KW)
12 inches 12 inches
M clearance to forced air supply inlet 6 feet 3 feet above air inlet
N clearance above paved sidewalk or paved driveway located on public property 7 feet 7 feet
P clearance under veranda, porch, deck, or balcony 22 inches to combustibles16 inches to non-combustibles 22 inches to combustibles16 inches to non-combustibles
Q clearance above roof 2 feet 2 feet
R clearance to adjacent walls and neighboring buildings 2 feet 18 inches
S clearance from corner in recessed location 12 inches 12 inches
T Maximum depth of recessed location 4 feet 4 feet
U Maximum width for back wall of recessed location 2 feet 2 feet
V Horizontal clearance between two terminations that are level 0 0
W Horizontal clearance (centre to centre) between two terminations that are not level 18 inches 18 inches
Note 1: For N a vent shall not terminate directly above the sidewalk or paved driveway which is located between two single family dwellings and serve both dwelling.Note 2: For P only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floorNote 3: For J, K, and as specified in CGA B149 installation code. Local codes or regulations may vary.* Based on CGA B149.1 Natural Gas and Propane installation code. Local codes may vary, please check with local regulatory agency. ** Based on ANSI Z223.1/NFPA 54 National Fuel Gas Code. Local codes may vary, please check with local regulatory agency.
Page 32 XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Appendix
Appendix B: Warranty
The Warranty
The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo fireplace, there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve, fibre logs and Power Vent Module. The Glass, plated / painted finishes, and refractory lining are exempt from the warranty.
Remedy And Exclusions
The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies will, at its option, refund the purchase price of the Montigo Gas Appliance.
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All replacement or repair components will be shipped F.O.B. the nearest The Companies factory.
Qualifications To The Warranty
The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1) The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo Gas Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas Appliance could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of local building codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies
(2) The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.
Limitations On Liability
It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
Investigation Of Claims Against Warranty
The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.
The Companies Are Not Responsible For Work Done Without Written Consent
The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.
Dealers Have No Authority To Alter This Warranty
The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated above.
How To Register A Claim Against Warranty
In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.
Other Rights
This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
NOTE: The Companies as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.
Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Page 33XG0816 - 011012.1
H*38DF PFC Peninsula Gas Fireplace
Appendix
Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10
(1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows:Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device
that will automatically shut off the gas to the burner in the event of a sustained back-draft.
(2) Revise 10.8.3 by adding the following additional requirements:(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equip-ment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectorsa. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed. 2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. 3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”. 4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. (b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and 2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or struc-ture used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 1. Detailed instructions for the installation of the venting system design or the venting system components; and 2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Prod-uct Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer: 1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions. (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. (3) After NFPA-54 section 10.10.4.2 add a new section 10.10.4.3 as follows:When more than four gas appliances are to be vented through a common gas vent or common horizontal vent manifold, a plan of the proposed vent installation
shall be submitted to the Inspector and the serving gas supplier for review and approval.
Extraction from: Massachusetts Rules and Regulations5.00: Amendments To 2002 Edition Of ANSI Z223.1-NFPA-54
Appendix C: State of Massachusetts
Ferndale, Washington
TF: 1.800.789.6236FX: 1.866.3000.0927
XG0816 - 011012.1
Langley, British Columbia
TF: 1.800.378.3115FX: 1.604.607.6462
H38DF PFCPeninsula Gas Fireplace