HomeMy WebLinkAboutB14-0136 Load Calcs.pdfLoad Calculation 516 Lodge at Vail
Vail, CO
General Lighting and Receptacle Demand Load:
1100 sq. ft. x 3VA = 3300
1,500 VA x 2= 3000
1,500 VA x 1 = 1500
Total connected load: 7,800
3,000 VA @ 100% = 3,000
VA @ 35% = 1,680.0
588
Total general lighting and
Receptacle demand load: 3,588
Range demand load:
12,000VA 8,000
Dryer Load:
5,000
Fixed appliance load:
Dishwasher 1.2 kva 1 existing 1,200
Garbage disposal .8 kva 1 existing 800
Total fixed appliance load: 2,000
Heating load:
electric heat 2 600
Total heating load: 600
25% of largest motor: 1,200
continued next page
Load Calculation 516 Lodge at Vail
Vail, CO
Totals:
General lighting and receptacles: 3,588
Range: 8,000
Dryer: 5,000
Fixed appliance: 2,000
Heating: 800
25% of largest motor: 1,200
Total:VA 20,588
AMPS 85.78
Existing Installed Service Size: 100A Single Phase