Loading...
HomeMy WebLinkAboutB14-0136 Load calcs.pdf.pdfLoad Calculation 516 Lodge at Vail Vail, CO General Lighting and Receptacle Demand Load: 1100 sq. ft. x 3VA = 3300 1,500 VA x 2= 3000 1,500 VA x 1 = 1500 Total connected load: 7,800 3,000 VA @ 100% = 3,000 VA @ 35% = 1,680.0 588 Total general lighting and Receptacle demand load: 3,588 Range demand load: 12,000VA 8,000 Dryer Load: 5,000 Fixed appliance load: Dishwasher 1.2 kva 1 existing 1,200 Garbage disposal .8 kva 1 existing 800 Total fixed appliance load: 2,000 Heating load: electric heat 2 600 Total heating load: 600 25% of largest motor: 1,200 continued next page Load Calculation 516 Lodge at Vail Vail, CO Totals: General lighting and receptacles: 3,588 Range: 8,000 Dryer: 5,000 Fixed appliance: 2,000 Heating: 800 25% of largest motor: 1,200 Total:VA 20,588 AMPS 85.78 Existing Installed Service Size: 100A Single Phase