Loading...
HomeMy WebLinkAboutB14-0138 COMCheck - Suite 205.pdfProject Title: Suite 205 GALLERY Report date: 04/11/14 Data filename: J:\2699.00 - Solaris 204 & 205\Ltg Calcs\269900LC01 - UNIT 205.cck Page 1 of 2 COMcheck Software Version 3.9.3 Interior Lighting and Power Compliance Certificate 90.1 (2007) Standard Section 1: Project Information Project Type: New Construction Project Title : Suite 205 GALLERY Construction Site: Owner/Agent: Designer/Contractor: Lot P, Block 5-D Vail Village Filing No.1 Vail, CO 81657 AE Design Group, Inc 1900 Wazee St. Ste 350 Denver, CO 80202 303.296.3034 Section 2: Interior Lighting and Power Calculation A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B x C) Retail:Sales Area 1301 1.7 2212 Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: T1 728(a)2.6 1893(b) Common Space Types:Active Storage 151 0.8 121 Supplemental Allowed Watts(c) =1000 Total Allowed Watts =5225 (a) Area claimed must not exceed the illuminated area permitted for this allowance type. (b) Allowance is (B x C) or the actual wattage of the fixtures given in Section 2, whichever is less. (c) Supplemental watts must be associated with retail merchandise highlighting fixtures. Supplemental watts are not included calculation of lighting complaince percentage. Section 3: Interior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures D Fixture Watt. E (C X D) Retail:Sales Area (1301 sq.ft.) Linear Fluorescent 1: R1: 2X2 RECESSED TROFFER: 24" T8 17W: Electronic: 2 1 33 33 Track lighting 1: T1: TRACK LIGHTING: Wattage based on 118 feet of track 0 0 3540 3540 Linear Fluorescent 2: (E): 4' LINEAR FLUORESCENT: 46" T5 HO 54W: Electronic: 1 2 64 128 Common Space Types:Active Storage (151 sq.ft.) Total Proposed Watts =3701 Interior Lighting PASSES: Design 12% better than code. Section 4: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 3.9.3 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Section 5: Post Construction Compliance Statement Record Drawings and Operating and Maintenance Manuals: 4/11/2014 Jeff Mullikin 4/11/2014 Project Title: Suite 205 GALLERY Report date: 04/11/14 Data filename: J:\2699.00 - Solaris 204 & 205\Ltg Calcs\269900LC01 - UNIT 205.cck Page 2 of 2 ❑1. Construction documents with record drawings and operating and maintenance manuals provided to the owner. Lighting Designer or Contractor Name Signature Date 4/11/2014 4/11/2014 4/11/2014 4/11/2014 4/11/2014