Loading...
HomeMy WebLinkAboutB14-0146 Mastiff040814 Aero Report.pdf780 Simms Street Suite 104 Golden, CO, 80401 303.232.3746 Certificate of Analysis www.aerobiology.net Client Name ECOS Environmental Date Collected:04/08/14 Street address 6690 Hwy 82 Date Received:04/09/14 City, State ZIP Glenwood Springs, CO 81601 Date Analyzed:04/09/14 Attn: Josh Johnson 200860-0 Date Reported:04/09/14 Client Project Name: Mastiff 040814 Project ID:14007792 Job ID: Test Requested:3002, Asbestos in Bulk Samples Method:Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Non-Asbestos Non-Fibrous Matrix Fiber Material Material Client Percentage Percentage Composition P = Perlite B = Binder D=Diatoms NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC 780 Simms Street, Suite 104, Golden, CO, 80401, 303.232.3746 4551 A1 4551 A2 4551 A3 N N 35% 65% 80% N Trace=Less Than 1% N N 10% 10% ND=None Detected CHRY=Chrysotile M = Mica CR = Crocidolite T = Tar TR = Tremolite A = Amosite Q = Quartz AC = Actinolite C = Carbonates AN = Anthophyllite G = Gypsum ND 15 85 100 P, G C ND 15 85 G ND 100 P, G ND ND 100 G ND 100 P, G ND 2 15 85 ND 100 C Asbestos Percentage White Tape ND 98N5% 20% Asbestos Detected White Joint Compound Laboratory Analyst Ron Weyand Asbestos Laboratory Supervisor Paul Knappe White/Tan Drywall White Perlitic Texture w/Tan Paint14007792-3B 14007792-3C White/Tan Drywall14007792-2B White Texture14007792-3A NVLAP Lab Code 14007792-1D 14007792-2A 20% N 55% 14007792-1C N Lab Sample Number N White/Tan Drywall White Perlitic Texture w/White Paint White Perlitic Texture w/White Paint Sample Identification Physical Description of Sample/Layer Homo- geneous (Y/N) Layer Percentage 14007792-1A 14007792-1B Page 1 of 2 780 Simms Street Suite 104 Golden, CO, 80401 303.232.3746 Certificate of Analysis www.aerobiology.net ECOS Environmental Date Collected:04/08/14 6690 Hwy 82 Date Received:04/09/14 Glenwood Springs, CO 81601 Date Analyzed:04/09/14 Josh Johnson 200860-0 Date Reported:04/09/14 Client Project Name: Mastiff 040814 Project ID:14007792 Job ID: General Notes  ND indicates no asbestos was detected; the method detection limit is 1 %.  Trace or "<1" indicates asbestos was identified in the sample, but the concentration is less than 1%. Notes Required by NVLAP  This test report relates only to the items tested or calibrated.  This report is not valid unless it bears the name of a NVLAP-approved signatory.  Any reproduction of this document must include the entire document in order for the report to be valid. 780 Simms Street, Suite 104, Golden, CO, 80401, 303.232.3746 NVLAP Lab Code  This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.  All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunerite. Crocidolite is the common name used for the asbestiform variety of the mineral riebeckite.  Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM floor tile analysis is accepted under NESHAP regulations.        These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.’s current terms and conditions of sale, including the company’s standard warranty and limitation  of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted.  Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days before discarding. A shipping and handling charge will be assessed for the return of any samples.  Aerobiology does not guarantee the results of tape lifts, microvacs, wipe, and/or debris samples. Accurate analysis cannot be performed due to particle size, media used, and/or amount of material given. Analysis of these materials should be preformed by a TEM. A result of ND does not indicate that the sample area does not contain asbestos. It means the analyst could not identify asbestos in the specific sample for the reasons listed above. Page 2 of 2