Loading...
HomeMy WebLinkAboutA0-03 - ASSEMBLY NOTES.pdfGENERAL ASSEMBLY AND FINISH SYSTEMS W1 NI GYPSUM BOARD PARTITION ON 2 x 4 WOOD STUDS NON-INSULATED (Non-Rated) (1) Layer 5/8" Type X gypsum board on each side of 2 x 4 wood studs (Re. Structural for size and spacing). W2 NI GYPSUM BOARD PARTITION ON 2 x 6 WOOD STUDS NON-INSULATED (Non-Rated) (1) Layer 5/8" Type X gypsum board on each side of 2 x 4 wood studs (Re. Structural for size and spacing). W3 SAUNA GYPSUM BOARD PARTITION ON 2x WOOD STUDS NON-INSULATED (Non-Rated) (1) Layer 5/8" Type X gypsum board on each side of 2 x 4 wood studs (2) Layer Type 5 Building Foil over Type "X" gypsum board. (3) Layer cedar plank or similar per sauna provider recommendations. (Re. Structural for size and spacing). Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general. WALL SYSTEMS: F1 WP WOOD PLANK ON HC CONCRETE SLAB Wood planks, installed per manufactur's specifications, over existing hollow core concrete slab. Planks over a sound dampening layer. F1 T TILE ON PT CONCRETE SLAB 18"x18" Ceramic Tile on thin set mortar over existing hollow core concrete slab. Provide transitions strips where there is a material change in floor finish. F1 CT CERAMIC TILE ON HC CONCRETE SLAB 18"x18" Ceramic Tile on thin set mortar over existing hollow core concrete slab. Provide transitions strips where there is a material change in floor finish. C1 GYPSUM BOARD CEILING CONSTRUCTION (1Hr-Rated) UL DESIGN NO. L521 & UL P533 5/8" Gypsum board on 7/8" furring channels attached to underside of floor trusses. CEILING SYSTEMS: FLOOR SYSTEMS: NOTES All gypsum wall board to be Type "X", typical at all locations. 2X4 STUDS @ 16" O.C., TYP. 5/8" TYPE "X" GYPSUM WALL BOARD, PAINTED, TYP. 3 1/2" 2X6 STUDS @ 16" O.C., TYP. 5/8" TYPE "X" GYPSUM WALL BOARD, PAINTED, TYP. 5 1/2" 2X4 STUDS @ 16" O.C., TYP. 5/8" TYPE "X" GYPSUM WALL BOARD, PAINTED, TYP. 3 1/2" SAUNA OTHER ROOMS TYPE 5 BUILDING FOIL CEDAR PLANK 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 103 WILLOW PLACE VAIL, CO 81657 Date 1 A0-03 ASSEMBLY NOTES EDELWEISS - UNIT 301 Project Number - 1402 05/23/14 PERMIT SET 3" = 1'-0" WALL ASSEMBLY 1 3" = 1'-0" WALL ASSEMBLY 2 NOTE: ALL GYPSUM WALL BOARD TO BE TYPE "X" 3" = 1'-0" WALL ASSEMBLY 3 06/10/14