HomeMy WebLinkAboutB14-0172 A3.02.pdfLEVEL 8 184' - 6" EXISTING STEEL STRUCTURE EXISTING FLOOR ASSEMBLY EXISTING METAL WALL PANEL EXISTING GLASS-MAT GYPSUM SHEATHING EXISTING WEATHER BARRIER EXISTING METAL STUDS EXISTING STEEL STRUCTURE REMOVE EXISTING GLASS-MAT GYPSUM SHEATHING AND REPLACE WITH 5/8" FIRE- RETARDANT TREATED PLYWOOD PLACE PRE-FINISHED METAL FLASHING OVER TOP OF THE EXISTING METAL PANEL LAP 90-MIL SHEET MEMBRANE OVER FLASHING. EXTEND SHEET MEMBRANE UP WALL AND INTO HOT FLUID APPLIED WATERPROOFING METAL JOISTS 5/4"x6" IPE WOOD DECKING WITH PLASTIC SPACERS AND CONCEALED FASTENER SYSTEMS STEEL TRACK 193' - 1" METAL THRU-WALL FLASHING 3/8" WEEPS AT 12" O.C. LAP HOT FLUID APPLIED WATERPROOFING OVER THE METAL FLASHING 1/4" DRAIN BOARD MORTAR STONE VENEER TO MATCH EXISTING 1 1/2" SNOW MELT STONE VENEER CAP TO MATCH EXISTING MATCH EXISTING GLASS GUARD SYSTEM. WAGNER PANEL GRIP DRY-GLAZE SYSTEM 194' - 7 1/4" FIRE-RETARDANT TREATED WOOD BLOCKING ZINC FLASHING EXISTING ROOF ASSEMBLY 4 LEVEL 8 184' - 6" 3/8" 1 1/2" 194' - 7 1/4" EXISTING STEEL STRUCTURE EXISTING FLOOR ASSEMBLY EXISTING METAL WALL PANEL EXISTING GLASS-MAT GYPSUM SHEATHING EXISTING WEATHER BARRIER EXISTING METAL STUDS EXISTING STEEL STRUCTURE REMOVE EXISTING GLASS- MAT GYPSUM SHEATHING AND REPLACE WITH 5/8" FIRE- RETARDANT TREATED PLYWOOD PLACE PRE-FINISHED METAL FLASHING OVER TOP OF THE EXISTING METAL PANEL LAP 90-MIL SHEET MEMBRANE OVER FLASHING. EXTEND SHEET MEMBRANE UP WALL AND INTO HOT FLUID APPLIED WATERPROOFING METAL JOISTS 5/4"x6" IPE WOOD DECKING WITH PLASTIC SPACERS AND CONCEALED FASTENER SYSTEMS STEEL TRACK METAL THRU-WALL FLASHING WEEPS AT 12" O.C. LAP HOT FLUID APPLIED WATERPROOFING OVER THE METAL FLASHING 1/4" DRAIN BOARD MORTAR STONE VENEER TO MATCH EXISTING SNOW MELT STONE VENEER CAP TO MATCH EXISTING MATCH EXISTING GLASS GUARD SYSTEM. WAGNER PANEL GRIP DRY-GLAZE SYSTEM FIRE-RETARDANT TREATED WOOD BLOCKING ZINC FLASHING EXISTING ROOF ASSEMBLY SCOTT MICHAEL NEVIN 202985 S T A T E O F C O L O R A D O L IC E N S E D A R C H I T E C T DPA Project: Sheet Number: COPYRIGHT 2011 - DAVIS PARTNERSHIP, P.C. Sheet Title: 2301 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 0225 Main Street, Unit C101 Edwards, CO 81632 970.926.8960 Denver Vail Consultant Issue/Revisions Date No. Sheet Information Project Information TOWN OF VAIL APPROVAL 4/23/2014 10:43:33 AM 06232.00.310 A3.02 SOLARIS - UNIT 701 EXPANSION DECK 141 EAST MEADOW DRIVE VAIL, COLORADO 81657 SECTIONS PERMIT SET 01APR2014 1 1/2" = 1'-0" 1 SECTION AT SOUTH WALL 1 1/2" = 1'-0" 2 SECTION AT WEST WALL 4/1/2014 11/12/14