HomeMy WebLinkAboutA4.02.pdfMAIN LEVEL -
PROPOSED
100' - 0"
J
I H G F
EXISTING PARAPET
WALL, RE: EXISTING
PLANS
POLYCARBONATE
PANELS, RE:
CERES GS
EXISTING WINDOWS TO
BE REMOVED AND
OPENING INFILLED,
COVER WITH NEW
MAGNESIUM OXIDE
PANELS
NEW SOLID CORE
HALF-LITE DOORS,
RE: SCHEDULE
NOTE: EXISTING DOORS
TO BE REMOVED AND
RELOCATED
RE: SCHEDULE
EXISTING STONE
VENEER WAINSCOT
TO REMAIN, TYP.
EXISTING STONE
VENEER WAINSCOT
TO REMAIN, TYP.
EXISTING SIDING TO
BE REMOVED AT ALL
INTERIOR WALLS,
TYP. MAGNESIUM
OXIDE PANELS,
RE: CERES GS
NOTE: AREA TO BE NEW OR
RECLAIMED STONE VENEER
WAINSCOT TO MATCH EXISTING,
BLEND EXISTING WAINSCOT AND
EXISTING COLUMN.
EXISTING CAFETERIA
ROOF
EXISTING
STRUCTURE,RE:
EXISTING PLANS
AREA OPEN TO
EXISTING
CAFETERIA PATIO
OPEN
BEYOND
B.O. LIGHT
8'-0"
4
12
EXISTING COLUMN
EMERGENCY LIGHTING
ABOVE DOOR PER CODE,
RE: SCHEDULE
GENERAL NOTES:
1. VERTICAL SIDING ABOVE
EXISTING STONE VENEER
WAINSCOT TO BE REMOVED.
TYPICAL AT ALL LOCATIONS.
2. MAGNESIUM OXIDE BOARD
PROVIDED BY CERES GS TO BE
INSTALLED ABOVE EXISTING
WAINSCOT. INSTALL PER CERES
GS SPECIFICATIONS.
3. ALL ELECTRICAL OUTLETS TO
BE COVER WITH A WEATHER
PROOF OUTLET COVER.
MAIN LEVEL -
PROPOSED
100' - 0"
ROOF A
115' - 0"
ROOF B
107' - 0"
2
A4.01
F
E D C B A
EXISTING STONE
VENEER WAINSCOT
TO REMAIN, TYP.
EXISTING STONE
VENEER WAINSCOT
TO REMAIN, TYP.
EXISTING SIDING TO
BE REMOVED AT ALL
INTERIOR WALLS, TYP.
MAGNESIUM OXIDE
PANELSABOVE
EXISTING WAINSCOT,
RE: CERES GS
EXISTING WINDOWS
TO REMAIN, TYP.
ELECTRICAL
OUTLETS LOCATED
ABOVE EXISTING
WAINSCOT, TYP.
GLULAM BEAMS
AND LEDGER, RE:
STRUCTURE
SIP ROOF PANEL,
RE: CERES GS
B.O. LIGHTS
8'-0"
LIGHTS TO BE HUNG
FROM RAFTERS, RE:
RCP
HOSE BIB, TYP.
MAIN LEVEL -
PROPOSED
100' - 0"
1
A4.01
5 6 7 8 9 10 11
EXISTING STONE
VENEER WAINSCOT
TO REMAIN, TYP.
EXISTING SIDING TO
BE REMOVED AT ALL
INTERIOR WALLS,
TYP.
MAGNESIUM
OXIDE PANELS,
RE: CERES GS
EXISTING STONE
VENEER WAINSCOT
TO REMAIN, TYP.
B.O. LIGHTS
8'-0"
LIGHTS TO BE HUNG
FROM RAFTERS, TYP.
ELECTRICAL
OUTLETS LOCATED
ABOVE EXISTING
WAINSCOT, TYP.
HOSE BIB, TYP.
MAIN LEVEL -
PROPOSED
100' - 0"
1 2 3 4 5
B.O. LIGHTS
8'-0"
POLYCARBONATE
PANELS, RE:
CERES GS
NEW SOLID
CORE DOORS,
RE: SCHEDULE
ELECTRICAL
OUTLETS
MAGNESIUM OXIDE
PANELS TO COVER
ENTIRE WALL, RE:
CERES GS
EXTERIOR HOSE BIB
LOUVER FOR EXHAUST FANS,
RE: CERES GS FOR SPECS,
RE: SCHEDULE FOR LOUVER SIZE
SIP ROOF
PANELS PANELS,
RE: CERES GS
LIGHTING HUNG
FROM RAFTERS,
RE: RCP
FAN CONTROLS,
RE: CERES GS
EMERGENCY EXIT
LIGHTING ABOVE
DOOR PER CODE,
RE: SCHEDULE
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
3000 BOOTH CREEK FALLS ROAD
VAIL, CO 81657
A4.02
INTERIOR
ELEVATIONS
VMS - GREENHOUSE
PROJECT #: 1365
05/14/14
PERMIT SET
3/8" = 1'-0"
A4.02
1 INT. ELEVATION 1
3/8" = 1'-0" A4.02
3 INT. ELEVATION 3
3/8" = 1'-0" A4.02
3A INT. ELEVATIONS 2
3/8" = 1'-0" A4.02
2 INT. ELEVATION 4
06/02/14