HomeMy WebLinkAboutB14-0190 GeoTech letter.pdfJune 30, 2014
Elk Meadows Development, LLC
Attn: Brian Redinger
141 East Meadow Drive, Suite 211
Vail, Colorado 81657 ., ·· .. ti !_.•.~!I JI
~rrM~ ;"1J![E~
TOWN OF VAIL
Job No. 114 086A
Subject: Observation of Excavation, Proposed Residence, Lot 3, Elk Meadows
Subdivision, 1628 Buffehr Creek Road, Vail, Colorado
Dear Brian:
As requested, a representative of Hepworth-Pawlak Geotechnical, Inc. observed the
excavation at the subject site on June 24 and 25, 2014 to evaluate the soils exposed for
foundation support. The findings of our observations and recommendations for the
foundation design are presented in this report. We previously prepared a subsoil study for
preliminary design of foundations at the site and presented our findings in a report dated
April 18, 2014, Job No. I 14 086A. The observation of the Lot 3 building excavation was
perfonned as additional services to our proposal for geotechnical services to Elk
Meadows Development dated March 24, 2014.
The proposed residence will be similar to that described in our previous report and be a
two-story wood frame structure above a walkout lower level with a slab-on-grade ground
floor. Spread footings placed on the natural soils and sized for an allowable bearing
pressure of 1,500 psfwere designed for the building foundation support.
At the time of our June 24 site visit, the foundation excavation was underway and about
half complete with very sandy silty clay soils exposed in the northern and eastern
portions. On June 25, the foundation excavation was essentially complete and had been
cut in multiple levels from about 2 to 12 feet below the adjacent ground surface. The
steps in grade between the levels ranged from about Yi to 4 feet. The soils exposed in the
bottom of the excavation consisted of medium stiff to stiff, sandy to very sandy silty clay.
Results of swell-consolidation testing performed on samples taken from the site, shown
on Figures I and 2, indicate the soils are moderately compressible under conditions of
loading and wetting with a nil to low hydro-compression potential. No free water was
encountered in the excavation and the soils were generally moist.
The soil conditions exposed in the excavation are consistent with those previously
encountered on the site and suitable for support of spread footings designed for the
..
Elk Meadows Development, LLC
June 30, 2014
Page 2
recommended allowable bearing pressure of 1,500 psf with some risk of settlement due
primarily to the compressible nature of the soils. Loose and disturbed soils should be
removed in the footing areas to expose the undisturbed natural soils and the subgrade
compacted. Other recommendations presented in our previous report which are
applicable should also be observed.
The recommendations submitted in this letter are based on our observation of the soils
exposed within the foundation excavation and the previous limited subsurface exploration
at the site. Variations in the subsurface conditions below the excavation could increase
the risk of foundation movement. We should be advised of any variations encountered in
the excavation conditions for possible changes to recommendations contained in this
letter. Our services do not include determining the presence, prevention or possibility of
mold or other biological contaminants (MOBC) developing in the future. If the client is
concerned about MOBC, then a professional in this special field of practice should be
consulted.
If you have any questions or need further assistance, please call our office.
Sincerely,
HEPWORTH-P
i
' -
David A. Young, P.E.\~21~.j
' -/-Ii ~
DAY /ksw ~~ ~" ~,,,,.. .... ,,
attachments Figures 1 and 2, Swell-Consolidation Test Results
Joh No. l 14 086A
Moisture Content = 15.9 percent
Dry Density = 106 pcf
Sample ot Sandy Silty Clay
From: Lot 3, Bottom of North-Central
Portion of Excavation, 6/24/14.
0 r----r--r--I'---'-r-. l~ -........, 1 ... , -'I~ \ Compression
'#. ~ j upon -wetting z 2 0 '\ \ 1/ w Cl) I\ w 3 r.... a: Cl. ) r-..LI :a: 0 ' (.) 4 \
\
5 \
I)
6
,.
0.1 1.0 10 100
APPLIED PRESSURE ( ksf)
114 086A ~ech SWELL-CONSOLIDATION TEST RESULTS FIGURE 1
HEPWORTH.PAWLAK GEOTECHNICAL
Moisture Content = 12.9 percent
Dry Density = 112 pcf
-200 = 53 percent
Sample of: Very Sandy Silty Clay
From: Lot 3, Bottom of South-Central
Portion of Excavation 6/25/14.
0 r---_ --:-._ r-1 ---1~ ~\ Compression
(fl. / upon -o., wetting z 2 0 ~~ ,,
(j) /v (/) ..__ v w 0: 3 D.. \ ~ 0 \ 0 4
" I\)
5
0.1 1.0 10 100
APPLIED PRESSURE ( ksf)
114 086A ~ SWELL-CONSOLIDATION TEST RESULTS FIGURE 2
HEPWORTl+PAWLAK GEOTECHNICAL.