HomeMy WebLinkAboutLot 3 Elect Load Calculation .pdfWIRE NUT ELECTRIC INC
PO BOX 1112
AVON, CO. 81620
970-926-8855
Load Calculation
May 16, 2014
Brian Redinger
Solaris Redevelopment Corp.
Load Calculation for lot 3 Elk Meadows
300 Amp single phase service for a 4,026 sq. ft. Single Family.
General Load:
4026 X 3VA Lighting
12,078VA
1500 X 6 small appliance circuits
9,000VA
2 Laundry
3,000VA
Range
7,560VA
Dishwasher
1,200VA
Refrigerator
1,200VA
2 Dryers
9,000VA
AC load greater than heating load including Heat Tape
14,500VA
Spa Tub
12,000VA
Steam Unit
12,000VA
Total 81,538VA
First 10 KVA @ 100%
10,000VA
Remainder of General Load @ 40% 71,538 X 40%
28,615VA
Total General Load 38,615VA
38,615VA / 240V = 161 Amps
We are going with a 300 amp service to allow for expansion of future electrical needs.
Thank You
Please call with any questions