PRODUCT AND INSTALLATION MANUAL
Professional Series Spectrum Systems
Central Water Filtration
Retain this Product & Installation Manual for Maintenance and Information
Please Register this Product - It is a Requirement for Warranty
EWS, Inc./Environmental Water Systems
office. 702.256.8182
Monday - Friday, 8:30 am - 4:30 pm Pacific Standard Time
fax. 702.256.3744
www.ewswater.com
e-mail. customerservice@ewswater.com
Model Numbers:
Spectrum Systems:
CS-EWS-1354-7000
CS-CWL-1354-7000
Chloramine Spectrum Systems:
EWS-CC-1465-7, EWS-CC-1865-7
CWL-CC-1465-7, CWL-CC-1865-7
Since 1987
ALL FILTRATION PRODUCT PROUDLY MADE & ASSEMBLED IN THE USA
2SCHEMATIC: SPECTRUM SYSTEMS
For Illustration Purposes Only:
Cut-away of CS-EWS-1354-7000
Tank, valve and all contents (as pictured below) delivered fully assembled.
Bypass and supplied adaptors some assembly required.
All measurements are approximates and system heights may have variances up to 1”.
Review this Manual for Proper Setup, Installation and Start-up of this System.
Model #’s: CS-EWS-1354-7000, CS-CWL-1354-7000
overall height
62”
height
to center of bypass
58”
tank
height
54” Outer Cover: White plastic cover and the coordinating plastic dome are
strictly aesthetic and are non-functional parts of the Spectrum System.
self leveling base
Tank: Non-corrosive, seamless, one-piece blow molded with tough epoxy and fiberglass outer laminate. Note: actual color of tank may vary.
Filtration: 2.5 cubic feet or 65 pounds of EWS proprietary high-grade granular activated carbon.
Freeboard: Space allows media space to lift during backwash.
Lower Riser Screen and Underbed: Maintains a closed system where
media does not escape into home plumbing during normal operation. The
underbed provides greater water distribution during filtration and backwash.
Conditioning (EWS Series Only): ICN Riser Manifold contains two ICN conditioners that catalytically suspend hardness minerals so they inhibit
adhesion to surfaces: Note: CWL Series does not contain this part.
Riser: Specialty PVC tubing food & beverage compliant for distribution of
filtered water flow up through the riser and out to the home or water down through the riser to lift and properly backwash in order to self clean filtra-
tion media
tank width 13”
Highly Recommended:Stainless steel corrugated water connectors, PEX or PVC Sch 40 have a flexible capability that may assist with issues where the rough and finish measurements are slightly off or where pressure surges/spikes or back pressure occur. This flexible connection may prevent tank and valve issues where rigid or hard pipe create problems over time. Perform all plumbing according to state or local codes.
18” clearance needed from center of tank for proper installation
Valve (front view)Not pictured: Bypass Valve to the rear of the Valve.
3SCHEMATIC: ALL SYSTEMS - Valve, Bypass, Adaptors and Valve Controls
BYPASSED IN SERVICE
Supplied Bypass Valve - All Systems
Top View
Outlet Valve
Closed
Outlet Valve
Open
Inlet Valve
Closed
Inlet Valve
Open
INLETIncoming
Water Supply
OUTLET
Filtered Water to
Home
INLETIncoming
Water Supply
OUTLET
NOTE: Inlet and Outlet Valves are closed and in the bypass position when the holes appear at the top and bottom as shown to the rightNo Flow Into System Flow Into System
to be Filtered
Flow of Filtered
Water from System NOTE: Inlet and Outlet Valves are open and in the service posi-tion when the holes appear at the sides (or do not appear on top) as shown to the leftValve Controls - All SystemsWhat is normally seen on the display:
Current Time of Day in Data Display
PM Indicator (if applicable)
Data Display will alternate (every 10 seconds) between Time of Day to another
number and then back to the Time of Day - this is normal and tells the user the next
time the system will backwash counting down each day from 6 (factory pre-set) until backwash
In Service Icon
During Installation when instructed:
Use the Up and/or Down Button to set
the Time of Day
Use the Extra Cycle Button to flush the
system. The Parameter Display will appear and indicate the cycle engaged (“BW” or
“RR”) during backwashing and the Data Display will indicate time remaining during a cycle
Contact EWS Customer Service if you see
an Error Icon or have wandered into a Pro-gramming Mode that you do not understand.
valve
controls 1” MNPT
drain fitting with grey clip
7’ electric cord & 24v transformer (not shown)
model number and labeling
NOTE: a total of seven (7) red connection clips are used**
A (1) - clip, top cap assembly, B (2) - clips, valve to bypass, C (2) - clips, bypass to adaptors, D (2) - clips, bypass assembly
Cbypass to adaptorsclip connections
Bvalve to bypassclip connections
A B C
CB
D
D
valve body built-in bypass
1”, 1 1/4” & 1 1/2”
MNPT adaptors provided
ALL SYSTEMS: Illustration of Complete Valve Assembly, Bypass and Provided Adaptors: 18” Overall Length Front to Back
3”on center
**WARNING: Removal of any red clip while unit is under pressure will result in water damage and damage to valve. See other cautions within this manual.
removablevalve
cover
Parameter Display DataDisplay PMIndicator
In ServiceIcon
Error InformationIcon
Programming Icon
Extra CycleButton UpButton DownButton
4
All measurements are approximates and system heights may have variances up to 1”.
Review this Manual for Proper Setup, Installation and Start-up of this System.
For Illustration Purposes Only:
Cut-away of EWS-CC-1865-7
On-Site Assembly Required
Due to shipping weight for all Spectrum Chloramine Systems,
tank, valve and all contents (as pictured below) must be assembled on site.
Bypass and supplied adaptors some assembly required.
SCHEMATIC: CHLORAMINE SPECTRUM SYSTEMS
Model #’s: EWS-CC-1465-7, EWS-CC-1865-7, CWL-CC-1465-7, CWL-CC-1865-7
overall height
73”
height
to center of bypass
69”
tankheight
65” Cover Not Available with Spectrum Chloramine Systems
self leveling base
Tank: Non-corrosive, seamless, one-piece blow molded with tough epoxy
and fiberglass outer laminate. Note: actual color of tank may vary.
Filtration: EWS proprietary high grade chloramine reduction media
Freeboard: Space allows media space to lift during backwash.
Lower Riser Screen and Underbed: Maintains a closed system where
media does not escape into home plumbing during normal operation. The underbed provides greater water distribution during filtration and backwash.
Conditioning (EWS Series Only): ICN Riser Manifold ICN conditioners that
catalytically suspend hardness minerals so they inhibit adhesion to surfaces.
Riser: Specialty PVC tubing food & beverage compliant for distribution of filtered water flow up through the riser and out to the home or water down
through the riser to lift and properly backwash in order to self clean filtra-tion media
• EWS-CC-1465-7 and CWL-CC-1465-7 contains 3 cubic feet or 90 lbs.• EWS-CC-1865-7 and CWL-CC-1865-7 contains 5 cubic feet or 150 lbs.
• EWS-CC-1465-7 contains 2 ICN Conditioners• EWS-CC-1865-7 contains 3 ICN Conditioners• CWL Series does not contain this part.
tank width
14” 1465 models18” 1865 models
18” clearance needed from center of tank for proper installation
Highly Recommended:Stainless steel corrugated water connectors, PEX or PVC Sch 40 have a flexible capability that may assist with issues where the rough and finish measurements are slightly off or where pressure surges/spikes or back pressure occur. This flexible connection may prevent tank and valve issues where rigid or hard pipe create problems over time. Perform all plumbing according to state or local codes.
Valve, Bypass Valve and threaded Adaptors (side view)
5Assembly Instructions - Chloramine Spectrum Systems Only
CHECKING THE PARTS LIST PRIOR TO ASSEMBLY
Below is a box count for each system and its’ contents.
EWS-CC-1465-7 and CWL-CC-1465-7 should have 6 boxes.
One Box - Tall containing the 14” x 65” Tank with a 1.05” (26.67mm) Riser ( ICN Riser Manifold - EWS Series only)
One Box (master carton) contains Valve, Valve Screen, Bypass Valve, Adaptors, Riser Cap, Funnel, Service Information Packet
One Box contains 50 lbs. underbed (pea gravel material specific to this system, filtration media and flow rate)
Three Boxes containing 1 cubic foot each of EWS’ proprietary Chloramine Reduction Media (CRM)
EWS-CC-1865-7 and CWL-CC-1865-7 should have 8 boxes.
One Box - Tall containing the 18” x 65” Tank with a 1.26” (32mm) Riser (ICN Riser Manifold - EWS Series only)
One Box (master carton) contains Valve, Valve Screen, Bypass Valve, Adaptors, Riser Cap, Funnel, Service Information Packet
One Box contains 50 lbs. underbed (pea gravel material specific to this system, filtration media and flow rate)
Five Boxes containing 1 cubic foot each of EWS’ proprietary Chloramine Reduction Media (CRM)
ASSEMBLY PROCEDURE - ALL SPECTRUM CHLORAMINE SYSTEMS
1. From tall box remove Tank.
Caution: Riser (or ICN Riser Manifold - EWS Series only) is in the Tank. Do not remove and be careful not
to damage. Riser will be positioned upon the loading of the underbed and filtration media.
2. Move the Tank to (or near) the systems’ final install location. The Tank will be getting heavy once filled.
3. From master carton remove Valve, Valve Screen, Bypass Valve, Adaptors, Riser Cap and Funnel.
4. Cap the top of the clean Riser to prevent filling with CRM filtration media. Use Riser Cap included or any heavy-duty tape.
5. Place or adjust capped Riser in the center of the tank.
Caution: Riser rests at the bottom and center of Tank. Do not press down and follow loading instructions.
6. Load the Tank, using supplied Funnel in the following order:
A: From one box with Underbed (a “pea gravel” for better water distribution) load all materials until box is empty.
Caution: Slowly fill and make small adjustments as needed to make sure Riser is straight up and down, and
centered in Tank.
B: Find 3 (1465 systems) or 5 (1865 systems) boxes with pre-measured CRM filtration media. This material is black and
granular. Empty all the contents of each box into the Tank.
Note: Top 1/3 of Tank should be empty. This is called freeboard for proper backwashing of the system.
Caution: Slowly fill and make small adjustments as needed to make sure Riser is straight up and down, and
centered in Tank.
Caution: Media is dusty. Do not inhale. Work in area with good ventilation and/or take preventative measures.
7. After Underbed and all CRM filtration media is loaded, remove the Riser Cap or tape from the top of the Riser.
8. Installation of the Valve onto the Tank:
A: Connect Valve Screen to the bottom of the Valve before connecting Valve to the Tank
B: Make sure the top of the Tank and Tank threads are clean of any debris or materials from Steps 1 through 6.
C: Center Riser where the Riser fits up into the center & bottom of the Valve. The Valve Screen at the bottom of the Valve
will help center and guide the Riser into the proper position. Back off the installation if resistence occurs and retry unitil
Riser fits into position without any issues.
Warning: DO NOT force Riser up into the center & bottom of the Valve. Riser should be straight and centered and
should fit snugly into that position. A Riser that is forced to fit, bent or off-center may fail under pressure.
D: Install the Valve onto the Tank by turning clockwise. Be careful not to cross-thread Valve onto Tank.
9. Thank you for properly filling and assembling the Tank, all its’ contents and connecting the Valve.
Please go to Page 7 and follow all instructions for the proper setup, installation and startup of all Spectrum Systems.
6
SCHEMATIC: SPECTRUM SYSTEM ............................................................................................... 2
SCHEMATIC: VALVE, BYPASS, CONTROLS - ALL SYSTEMS.............................................................. 3
SCHEMATIC: SPECTRUM CHLORAMINE SYSTEM ....................................................................... 4
SPECTRUM CHLORAMINE SYSTEM: ON SITE ASSEMBLY PROCEDURE............................................. 5
IMPORTANT SAFETY INFORMATION – All Systems Instructions Before Using ........................................................................................................ 7
SETUP - All Systems ....................................................................................................................... 8 Unpacking and Inspection Where to Install the System
INSTALLATION INSTRUCTIONS - All Systems Plumbing Connections ..................................................................................................................... 9 Drain Line .................................................................................................................................. 11 Electrical Connection ..................................................................................................................... 11
START-UP PROCEDURES - All Systems Flush and Clear Home Lines with System Still in Bypass ................................................................. 12 Tank Fill Slowly .................................................................................................................................. 12 Setting the Time of Day while The Tank is Filling Slowly ................................................................. 13 Flushing the System Procedure ........................................................................................................ 13 Last Steps Before Leaving the System ........................................................................................... 15 Repeat Flushing (if needed) Open Outlet Side of Bypass System Ready for Use Run Water throughout the Home
GENERAL TERMS AND STANDARD CONDITIONS OF SALE ..................................................... 17
LIMITED WARRANTY ....................................................................................................................... 18
www.ewswater.com o. 702.256.8182; (m-f; 8:30am-4:30pm; PST) f. 702.256.3744 e-mail. customerservice@ewswater.com
Table of Contents
7
Instructions Before Using
• Before beginning installation, read all instructions completely. Then obtain all the materials and tools needed
for installation.
WARNING:
Failure to setup, install and/or startup the system correctly in any manner voids the warranty.
• Perform installation according to state and local plumbing codes.
- Use of flexible stainless steel connections is highly recommended (if code applicable) to connect unit to
water supply. Allows flexibility for tank expansion under pressure (see installation section in this manual).
- Use of teflon tape is the only sealant to be used on threaded drain and adaptor connections.
- Use only lead-free solder and flux for sweat-solder connections, as required by state and federal codes.
• Handle all components of the system with care. Do not drop, drag or turn components upside down.
• Existing Plumbing: Condition of existing plumbing should be free of lime &/or iron buildup. Pipe should be
replaced if any heavy buildup exists. Pre-existing conditions will effect the performance of this system.
• Be sure the floor under the system is clean and level.
• Electrical: All Spectrum Systems (USA versions) use 24 volt transformer for electrical power.
- Always use the supplied power cord and transformer.
- Plug power cord into an indoor 120 volt, grounded and unswitched (dedicated) outlet.
- Properly ground system to conform with all codes and ordinances.
• Install system in a protected area. Be sure electric outlet and transformer do not come in contact with water.
See “Where to Install the System” in the Setup section, Page 7 of this manual.
- Always connect the system to the proper and correct main water supply pipe before the water heater(s).
- Do not install in direct sunlight. Heat from sun may cause damage.
- Do not flow any water at any time over 110°F through the system.
- Do not expose system to freezing temperatures which causes equipment damage and voids the warranty.
WARNING:
Any water over 110°F, thermal expansion of any water heater or where any hot or heated water
comes back or flows through the system over 110°F at any time voids the warranty.
• Pressure: Minimum inlet water pressure is 20 psi. Maximum inlet water pressure is 75 psi. Use pressure
reducing valve (PRV) if necessary to prevent high pressure and problem pressure surges above 75 psi.
WARNING:
Pressure exceeding, surging or spiking above 75 psi or any negative pressure voids the warranty.
Important Safety Information - All Systems
CAUTION: Read and follow the information in this manual to minimize the
risk of electric shock or personal injury.
IMPORTANT! If you are unsure about the installation of your system, con-
tact EWS customer service or consult a professional plumber.
IMPORTANT! This system must be installed in compliance with applicable
state and local codes, law, and regulations.
CAUTION:
• Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection. Well water needs to be properly and completely
tested before the specification of any filtration and treatment system(s).
• Test water periodically to verify that the system is performing satisfactorily.
• Discard small parts remaining after the installation.
8
UNPACKING AND INSPECTION
Check the system components for damage or missing parts.
WHERE TO INSTALL THE SYSTEM
Consider the following points when determining where to install any Spectrum System point of entry filter:
Place system on the main water supply in order to filter and supply filtered water to the entire home.
CAUTION: DO NOT install on a soft water loop or bypass of other water lines where the filtered water will not
be available for household use. All Spectrum Systems are designed to filter water to the entire
home.
NOTE: All Spectrum Systems can connect for outside faucets for plants, lawn, pools, spas, and other
features. However, it is nice but not necessary under normal circumstances for any outside ap-
plication. It will cause no harm to the system or the other features but will use more water through
the system and may not create any additional benefits for those features.
Place the system as close as possible to a sewer drain or some other drain location. Air gap and proper
ventilation is a requirement. Drain and water can go outside. Contact EWS customer service for more information.
CAUTION: Never install drain line smaller than 3/4” in diameter. Any drain line exceeding 20’ in total
length and/or is expected to flow over 5’ above the height of the drain port requires an
installed drain line of 1”. Install a non-restrictive check valve in drain line if water is expected to
flow 5’ above drain port.
A 120V grounded and unswitched electrical outlet is needed to plug in the transformer. If outlet is over 7 feet
away use 18 gauge extension to connect up to 100 feet away. Do not exceed 100 feet.
Do not install the system where it would block access to the water heater, or access to the main water shutoff,
water meter, or electrical panels. Always connect the system prior to the water heater(s).
Install the system where it will not be exposed to direct sunlight or subject to temperatures outside of the limits
stated in “Instructions Before Using” on Page 7 or the Specification Section in this manual. The system is water
resistant but not water-proof and should be protected from outside and weather exposure if applicable.
Install the system in a place where damage is least likely to occur if any unforeseeable issue arises.
System should be in an accessable location and be visable in order to visually monitor system and routinely check
clock operation and valve controls.
Setup - All Systems
9Installation Instructions - All Systems - Plumbing Connections
INSTALLATION
1. Turn off gas or electric supply to the water heater(s).
2. Turn off the main water supply.
3. Open a hot and cold faucet to drain house water pipes.
NOTE: Keep those hot and cold faucets open until these instructions tell you to close.
4. Move the system assembly into installation position and check that Valve is securely fastened to the Tank.
CAUTION: Factory assembly of Valve to Tank connection is performed according to specifications. However
in transportation, delivery and movement to the installation position this connection may have loos-
ened. It is important to make sure this connection is tight and if necessary hand-tighten only in a
clockwise direction to ensure this connection.
NOTE: System has a self-leveling base which can compensate for any slight floor pitch. Refer to “Instruc-
tions Before Usng” on page 7 and “Where To Install The System” on page 8.
5.a In the parts bag: Locate the Bypass Valve and 2 red clips
Connect Bypass Valve to the Valve by inserting male end of the Bypass Valve completely into the Valve body.
Make sure that male end is fully inserted into Valve and only then install the red clips to secure that connection.
CAUTION: The red clips will break if you attempt to force into position without fully inserting the male end con-
nector into the valve body. If the connector is inserted properly the red clip insertion path will be
clear. Installer is responsible for securing plastic red clips when attaching bypass and adaptors.
To remove red clips simply use pliers and hold tab at top and pull straight up and out.
CAUTION: Check that all surfaces are clean of any debris before inserting Bypass Valve into valve body.
5.b In the parts bag: Locate the 1”, 1 1/4” or 1 1/2” MNPT Adaptors.
Select the proper sized Adaptor for your incoming/outgoing water lines and connect the Adaptors to the supplied
Bypass Valve.
NOTE: 1” adaptors with red clips may already be inserted for shipping purposes. This is also the most common line
size. Flow rate to system is determined by the incoming line size. If needed, select and use proper adaptor
(1”, 1-1/4”, or 1-1/2”) for the main line size that the system is being installed on.
If needed, to remove red clips simply use pliers and hold tab at top and pull straight up and out.
CAUTION: The red clips will break if you attempt to force into position without fully inserting the male end con-
nector of Adaptor into the Bypass. If the connector is inserted properly the red clip insertion path will
be clear. Installer is responsible for securing plastic red clips when attaching bypass and adaptors.
CAUTION: Check that all surfaces are clean of any debris before inserting Adaptor into Bypass Valve.
WARNING:
Make sure on the Bypass Valve both Inlet and
Outlet Valves are in the bypass position
NOTE:
When Inlet and Outlet Valves are in the bypass
position the holes appear at the top and bottom
as shown in the illustration to the right.Valve in BypassOutlet Inlet
Valve in BypassInserted Adaptors for Water Line
Connections
Insert Connections
into Valve Body
Illustration of Bypass Valve in the bypass position
Top View
10
6. Locate water line or pipe to be cut and make sure of direction of water flow.
CAUTION:
Do not cross-connect or plumb backwards. Make sure of the direction of water flow from cut pipe to be connected.
7. Plumb INLET and OUTLET connections to and from the system.**
• It is highly recommended to use stainless steel corrugated flexible water connectors, PEX or PVC Sch 40.
• Be sure the incoming hard water supply is directed to the INLET port of the valve.
• The valve body of the control is marked with arrows indicating the proper flow direction.
• Connections are illustrated below.
** Highly Recommended:
• Stainless steel corrugated flexible water connectors, PEX or PVC Sch 40 have a flexible capability that will assist
with the installation where the rough and finish measurements are slightly off.
• Flexible connections may prevent tank and valve issues where rigid or hard pipe create problems over time
where the installed system is on a bottom or top floor of a home and/or where the home location is on the top
or the bottom of a hill where head pressure or pressure variances will occur or wherever pressure variations
cause tank to flex or move.
• Flexible connections are recommended where high pressure, pressure surges/spikes or pressure variations occur
CAUTION: An operating and maintained pressure reducing valve (PRV) may be required on the main water line and
prior to the system to regualte pressure. If applicable, a check valve on the main supply before the system
or a check valve on the outlet side of the the system (water heater will require expansion tank) to prevent
backflow and excessive head pressure may be required.
WARNING: Any pressure on the system exceeding, surging or spiking above 75 psi and any negative pressure due to
vacuum break voids the warranty.
Installation Instructions - All Systems - Plumbing Connections - continued
CAUTION: If making a soldered copper installation, do all sweat soldering before connecting pipes to the bypass valve. Torch heat will damage plastic parts.** It is highly recommended to use stainless steel corrugated flexible water connectors.
CAUTION: When turning threaded pipe fittings onto plastic fittings, use care not to cross-thread, strip threads and/or over-tighten.
CAUTION: Use Teflon tape only on all external pipe threads. Do not use pipe joint compound.
CAUTION: Support inlet and outlet plumbing in some manner (use pipe hangers) to keep the weight off of the valve fittings.
valve
controls 1” MNPT
drain fitting with
grey clip
7’ electric cord & 24v transformer (not shown)
model number and labeling
Note: a total of seven (7) red connection clips are used
A (1) - clip, top cap assembly, B (2) - clips, valve to bypass, C (2) - clips, bypass to adaptors, D (2) - clips, bypass assembly
Cbypass to adaptorsclip connections
Bvalve to bypassclip connections
A B C
CB
D
D
valve body built-in bypass 1”, 1 1/4” & 1 1/2”
MNPT adaptors provided
Inlet
Outlet
Recommended 1”, 11/4” or 11/2” flexible connection (not supplied)
Note: bypass valve shown in the closed position with holes on top for cor-rect install
Illustration of complete assembly of valve, bypass and provided adaptors
**WARNING: Removal of any red clip while unit is under pressure will result in water damage and damage to valve. See other cautions within this manual.
11
INSTALL DRAIN LINE - THIS IS A SIMPLE BUT IMPORTANT STEP TO AVOID CROSS-CONTAMINATION
8. Plumb rigid tubing only (PVC recommended if code applicable) directly to the 1” MNPT drain fitting.
NOTE: Install a union on the drain line in order make any service or need to disconnect easier in the future.
9. Connect and route the drain line to the drain point. Install a non-restrictive spring check valve within 2 feet of
the control valve to prevent possible back flow and cross-contamination
CAUTION:
• Never install drain line or connect to any drain line less than 3/4”
• Any drain line exceeding 20 feet in total length and/or is expected to flow over 5 feet above the height of
the drain port requires an installed drain line of no less than 1”.
10. Locate the end of the drain line at a suitable drain point and create an air gap.
NOTE: Outside system draining is allowable. It is only filtered water and not a brine discharge.
CAUTION:
• Do not freeze. Do not block or bury water flow. Drain line and surroundings must be pitched or sloped to allow
for proper water flow and drainage where drain water never sits in the line or any landscape or rain water
is allowed to create standing water at the drain line. Allow enough space (lawn, planter, water storage) to
flow and absorb up to 140 gallons (eqivalent to 4 showers) of water every 6 days.
• If using a sink, floor drain or any other drain point, an air gap is required and the drain point needs to be
capable of draining water away at up to 7 (gpm) gallons per minute for up to 20 minutes (similar to 4
showers once every 6 days) to avoid water damage.
CAUTION:
• Secure (clamp, tie or wire) installed drain line in place at the drain point to prevent movement and avoid
any possible water damage.
Installation Instructions - All Systems - Drain Line and Electrical
INSTALL ELECTRICAL CONNECTION
11. Connect electrical power by plugging the transformer into a 120V grounded
and unswitched electrical outlet.
If outlet is over 7 feet away use 18 gauge extension to connect up to
100 feet away. Do not exceed 100 feet.
NOTE:
Power consumption is that of a radio alarm clock, doorbell or timer clock
used for sprinklers or irrigation.
PROCEED TO THE PROPER TANK FILL OF THIS SYSTEM
REQUIRED:
• Provide a minimum 1/2” air gap between the end of the drain line
and the drain point. (see illustration to the right)
• Install a non-restrictive spring check valve in drain line within 2 feet
of the control valve
CAUTION:
• Air gap and proper air flow and ventilation (Caution: attics and crawl
spaces) is necessary to prevent any back up or cross contamination
into system. Do not enclose or cover up drain point. It would be best
if you can see the water flowing from the drain line into the drain
point. (see illustration to the right)
12
Outlet Valve
in Bypass
Outlet Inlet
Illustration of Bypass Valve in Bypass
Top View
Inlet Valve
in Bypass
Startup Procedures - All Systems - Tank Fill
PROCEED TO THE PROPER FLUSH OF THIS SYSTEM
FLUSH AND CLEAR HOME LINES WITH SYSTEM STILL IN BYPASS
12. Keep Bypass Valve in “bypass” position
and follow startup procedures
NOTE:
Holes appear on the top and bottom
of Bypass Valve when in bypass
(see illustration to the right)
13. Turn back on gas or electric supply to the water heater(s).
14. Slowly open the main water supply and observe a steady flow from both hot and cold faucets that were
opened earlier (Page 9, Step # 3). Check plumbing work for leaks and fix immediately if any are found.
NOTE: Remove the aerators or any restriction at the end of the faucets and let the faucets run for a few minutes
until water is free from foreign material that may have resulted from installation or material that typically
loosens up when shutting off and turning on the water at the main supply.
15. Once all bypassed water has been allowed to run clear - Shut off both hot and cold faucets.
NOTE: If water appears cloudy, allow to run for several more minutes until all air is expelled or until clear.
TANK FILL - SLOWLY
16. Now it is time to fill and flush the system to properly start up the system.
Careful to follow instructions to prevent water hammer or unnecessary pressure on tank,
valve and filtration media within tank.
Inlet Side Only:
(see illustration to the right)
Slowly Crack Open
Turn inlet side valve counter-clockwise
where hole appears as illustrated.
Only enough where you start
to hear the water flowing into the tank.
CAUTION:
Bypass Valve is only a 1/4 turn.
Allow the tank to fill SLOWLY.
Outlet Valve in Bypass
Illustration of Bypass Valve - Partially Open Inlet
Top View
Outlet
Closed Inlet
Inlet Valve
Partially Open
to Fill System Slowly
13Startup Procedures - All Systems - Flushing the System
FLUSHING THE SYSTEM
18. With the inlet side of the Bypass Valve still only PARTIALLY open and the tank still filling slowly - it is time to
manually backwash and flush the system.
CAUTION:
The outlet side of the Bypass Valve remains closed and in the bypass position until this flushing procedure has
been completed
19. Manually start a backwash to flush the system.
• Press and hold (5 seconds) the Extra Cycle Button until the Parameter Display flashes “BW” and the Data
Display reads “----”.
• You will hear the valve engage and it will take about 1 minute (60 seconds) until the backwash “BW”
cycle is reached.
• Once the backwash “BW” cycle begins the Parameter Display will stop flashing and reads “BW” and
the Data Display is counting down from 9:59 in 1 second increments. This backwash is a 10 minute cycle.
17. While tank is slowly filling, Set the Time of Day by presssing either the Up or Down Button.
The Parameter Display will read “TD” for Time of Day and the Programming Icon will appear
Continue to press either Up or Down Button until the Data Display reads the current time of day.
If after 12:00 (noon) then the PM Indicator should be lit.
Once set, allow up to 10 seconds and the “TD” and will disappear.
What you will see on the display:
• Current Time of Day, a PM Indicator (if applicable)
• You will also see the Time of Day alternate (about every 10 seconds) to another number and than back to
the time of day - this is normal and tells the user the next time the system will backwash counting down
each day from 6 (factory pre-set) until backwash.
• In Service Icon
The diagram to the right is an
illustration of the system valve
controls and all the displays
for your reference.
Please follow the directions
above to set the time of day.
Please follow the directions
below to manually advance
the system through each step
of the backwash and flushing
procedure.
SETTING THE TIME OF DAY WHILE THE TANK IS FILLING SLOWLY
Parameter
Display
Data
Display PMIndicator
In ServiceIcon
Error Information
Icon
Programming Icon
Extra CycleButton UpButton DownButton
14
WARNING:
Failure to follow these procedures can result in debris in the system, the system’s valve, the home and/or
filtration media being expelled causing immediate, short and long term issues with the system’s valve,
into the home pipes and the fixtures or appliances within the home.
21. The Inlet Side of the Bypass Valve is completely open (Outlet Side remains closed).
The air has been purged from the system and the tank has been filled.
The backwash is running in order to clean and flush filtration media prior to system usage.
What you will see on your display and hear as the valve goes through the self-cleaning and flushing,
backwash and rapid rinse cycles:
• The backwash “BW” cycle is already engaged (Page 10, Step # 19) and Data Display is counting down.
• When the backwash “BW” cycle ends, the Parameter Display will flash “RR” and the Data Display reads
“---”
You will hear the valve engage again and it will take about 11/2 minutes (90 seconds) to engage the cycle.
• When the rapid rinse “RR” cycle begins the Parameter Display will stop flashing and reads “RR” and the
Data Display is counting down from 9:59 in 1 second increments. This rapid rinse is a 10 minute cycle.
• When the rapid rinse “RR” cycle ends, the valve will engage again and it will take about 30 seconds for
the valve to return to the in service position and the display will show the In Service Icon and your Time of
Day.
NOTE:
Allow system to go through complete backwash and rapid rinse cycles which will take from start to finish up to 23
minutes.
See Step #’s 22 through 24 on Page 15 to conclude the proper setup, installation and startup of the system.
FLUSHING THE SYSTEM - CONTINUED
20. When the air in the system is pushed out and water begins to flow continuously through the drain line, it is time to
completely open the Inlet Side (only) of the BypassValve.
This will purge air and relieve the pressure within the tank and completely fill the tank in the proper order.
CAUTION:
The outlet side of the Bypass Valve remains
closed and in the bypass position until this
flushing procedure has been completed
NOTE:
Holes appear on the top and bottom
of Bypass Valve when in bypass (Outlet).
Holes appear on the front and back
of Bypass Valve when open (Inlet).
(see illustration to the right)
Startup Procedures - All Systems - Flushing the System
Outlet Valve
in Bypass Inlet ValveOpen
Illustration of Bypass ValveClosed Outlet with Open InletTop View
Outlet Inlet
15
22. Check the drain water is clear of any filtration media dust and/or fines. A quick repeat of the the flushing procedure
is recommended.
Start a backwash again (Page 13, Step # 19) and once water flows under full pressure through the drain line check
for any dust and/or fines. Allow water to run through the drain line for at least 60 seconds.
Once the drain water appears clear, force the control to advance to the next cycle step immediately by pressing and
releasing the Extra Cycle Button. The Parameter Display flashes “RR” and the Data Display reads “----”.
You will hear the valve engage again and it will take about 11/2 minutes (90 seconds) to engage the cycle. Once
water flows under full pressure through the drain line check for any dust and/or fines. Allow water to run through the
drain line for at least 60 seconds.
Once the water runs clear, force the control to advance to the next cycle step immediately by pressing and releasing
the Extra Cycle Button. The valve will engage again and it will take about 30 seconds for the valve to return to the
in service position and the display will show the In Service Icon and your Time of Day.
23. Slowly open the Outlet Side of the Bypass Valve
Final Steps - All Systems
LAST STEPS BEFORE LEAVING THE SYSTEM
NOTE:
Holes appear on the front and back
of Bypass Valve when open.
(see illustration to the right)
24. System is ready for use.
To ready home for filtered water, open as many hot and cold faucets throughout the home as possible. Remove
the aerators or any restriction at the end of the faucets. Remember to include tubs and dispose of any ice previ-
ously made. Run water throughout home for 5 minutes.
NOTE: If water appears cloudy, allow to run for several more minutes until all air is expelled or until clear.
NOTE:
If home is a year or more old, it is highly recommended that all water heaters or tankless on-demand heaters be
flushed and that all dishwashers, washers and any other water appliances be cleaned of any existing residue.
Please review Page 7 “Instructions Before Using” for existing plumbing and pre-existing conditions that will effect
the performance of this system.
WARNING:
Failure to follow these procedures can result in debris in the system, the system’s valve, the home and/or
filtration media being expelled causing immediate, short and long term issues with the system’s valve,
into the home pipes and the fixtures or appliances within the home.
Outlet Valve
Open Inlet ValveOpen
Illustration of Bypass Valve
Open Outlet and Inlet
Top View
Outlet Inlet
16
INTENTIONALLY LEFT BLANK
Complete sections to assist with any troubleshooting, parts listings, replacement filters,
media replacement information, product specifications and information
are all available online.
If you need any additional information or assistance, please call
EWS, Inc. customer service.
702.256.8182 m-f, 8:30am - 4:30pm, pacific standard time
customerservice@ewswater.com
www.ewswater.com
17
Invoices are expressly limited to and made conditional upon the terms and conditions contained herein. Objection by Buyer to any
of the terms contained herein shall be deemed to have been waived (if not previously waived) if written notice of the objection is not
received by EWS, Inc. (“EI”) within ten calendar days of the date of the first invoice or before part of the described goods are accepted
by Buyer, whichever occurs first. Any additional or different terms proposed by Buyer are rejected unless assented to in writing by EI.
1. PRICES: All prices are in U.S. dollars. Prices are subject to change without notice. Orders will be invoiced at prices prevail-
ing at time of shipment. All prices are F.O.B. our warehouse, Southern California and exclusive of any shipping, delivery, packaging
or handling charges that may apply.2. TERMS OF PAYMENT: The terms of payment on approved accounts only shall be net thirty days in U.S. dollars from the date of invoice to date of receipt of payment in our offices for all invoiced products whether partial or complete delivery of the product
under order. All past due accounts are subject to a charge of 11/2% per month (18% per annum) for each month or fraction of a month
on the unpaid balance.
3. TAXES: Prices do not include sales, use, excise or similar taxes. The amount of any present or future sales, use, excise or
other tax applicable to the sale or use of EI’s products or equipment shall be paid by the Buyer unless the Buyer shall have provided EI with a tax exemption certificate acceptable to taxing authorities.
4. ACCEPTANCE: All purchase orders are subject to acceptance by EI at its corporate offices in Las Vegas, Nevada and are
subject to these Standard Conditions of Sale, unless otherwise expressly provided.
5. SHIPMENTS: Delivery to carrier shall constitute delivery to customer. EI’s responsibility terminates upon delivery in good order
to carrier. All goods are shipped at the customer’s risk. Any claim for loss or damage in transit should be made promptly by customer against carrier. These and other shipment terms are written clearly on the reverse side of all packing slips that accompany all accepted
shipments. All costs of freight, transportation, handling, in-route storage, certification and other documentation are to be paid by Buyer.
Any other terms will be issued to Buyer, in writing, with approved credit and an established EI/Buyer relationship.
6. DELAYS; FORCE MAJEURE: EI shall not be liable for delays in delivery of the goods or failure to deliver the goods caused,
in whole or in part, by inability to obtain transportation, equipment, or material, insurrection, fires, floods, storms, embargoes, action of any military or civil authorities, whether legal or de facto, strikes, labor difficulties, lockouts, acts of God, or other similar or different
circumstances beyond the control of EI.
7. CANCELLATION: The Buyer may not cancel all or part of an order without verifiable notification to, and acceptance by EI.
8. RETURN OF MATERIALS: No Product may be returned to EI without written approval by a Company Officer. A restocking
charge of 25% will be assessed (45% if unit had been used) NO EXCEPTIONS. Product must be returned freight pre-paid, boxed and in resale condition. EI will never take responsibility, under warranty or return, for improperly installed and/or misrepresented units.
9. SELLER’S SECURITY INTEREST: EI shall retain a security interest in the goods sold hereunder until Buyer has paid in full
for such goods provided by EI in connection therewith and has performed all of Buyer’s obligations under this contract.
10. COLLECTION: Buyer shall reimburse EI for all costs of collection, including reasonable attorney’s fees, incurred by EI to
collect any monies owing under this contract. A $45.00 service charge will be invoiced on all returned checks.11. WAIVER AND MODIFICATION: No waiver or modification of any of these Standard Conditions of Sale shall be effective
unless such waiver or modification is in writing and signed by an officer of the Company in Las Vegas, Nevada. In event any part of
these conditions be waived, or be held to be invalid by any competent court, the remainder shall continue in force and shall be inter-
preted as if such waived or invalid part were not contained herein.
Published and Printed in the U.S.A.EWS Inc./Environmental Water Systems
9101 W. Sahara Ave., Suite # 105-J8, Las Vegas, Nevada 89117
ph 702-256-8182, fx 702-256-3744 customerservice@ewswater.com
(formerly, Esbinco, Inc.) rev: 1/11www.ewswater.com
EWS, Inc. has a current, published, and widely distributed, Pricing Guide that contains suggested list prices for certain water filtration
and conditioning products (“Products”) sold by EWS, Inc. (“Seller”). Seller assumes no obligation to sell to anyone any of the Products
listed herein, known or unknown, at any price.
This current Pricing Guide has been prepared for the convenience of Seller’s distributors and their customers. The list prices
shown are guides only and do not purport to represent actual prices in any particular market and are not intended to interfere with the right and responsibility of Seller’s distributors to establish their own resale prices.
All current prices herein set forth supersede all prior lists and are subject to change without notice. Seller may also, from time to
time, change, modify, alter, improve and/or discontinue without notice the sale of any of the Products listed herein.
All seller’s orders are accepted and delivered based upon the Terms and Conditions found on this Pricing Policy page, found in
this Pricing Guide, available in all Seller’s Product Manuals and reprinted on the reverse side of all invoices submitted and monthly statements sent. Please read them carefully. They provide information that is important to Seller’s distributors and their customers.
PRICING POLICY
GENERAL TERMS AND STANDARD CONDITIONS OF SALE
18
Notification:This warranty is referenced by EWS, Inc. in all literature, addressed in General Terms and Standard Conditions of Sale, and
is published in its entirety in all EWS, Inc. product manuals, websites, and in all service guides supplied with all product.
Limited Warranty: EWS, Inc., a Nevada corporation, hereby warrants all products to the original consumer purchaser to be free from defects in material and workmanship as stated in the following paragraphs:
• All residential point of use: countertop filtration, in-line filtration, undercounter drinking water filtration, shower filtration,
residential reverse osmosis, and canister and filter cartridge point of entry pre-sediment and/or filtration units or systems for one year from date of purchase.
• All residential point of entry: pH decreasing and softener (resin and ion-exchange) systems, Environmental (EWS) Water
Systems, Iron Removal units, CWL whole-home (filtration media) systems, pH increasing reagent (sacrificial media) units
for 10 years on the tank and riser, 10 years on the ICN conditioner(s) (if applicable) and 5 years on the valve head from date of purchase.
• All commercial systems: Dependent on specification and application, please consult with EWS, Inc. upon specification.
• All filtration medias, resins, cartridges, uv lamps, and/or membranes are not covered by any warranty. Filter media, resin, cartridge, uv lamp, and/or membrane replacement or maintenance schedule will vary and must be replaced, as necessary, as determined by usage and local water conditions.
Product performance may vary based on local water conditions, proper product specification and application, proper plumbing
application, setup, installation, startup, maintenance and/or usage. To ensure proper operation, follow all setup, installation, start-up and maintenance procedures as detailed in all service guides.
Not intended for use where water is microbiologically unsafe or with water of unknown quality without adequate disinfection
before or after unit(s). The contaminants or other substances removed or reduced by these and any other water filtration or
treatment devices are not necessarily in your water. To confirm the presence of any primary and secondary contaminants, have your water supply completely analyzed by an independent and approved facility or if applicable, contact your local water utility for information. Aesthetic, non-health related, or constituents without set federal standards may be part of water
testing but are insufficient to determine proper application of any water filtration or treatment device.
EWS, Inc. will replace, free of charge, during the warranty period, any part which proves defective in material and/or work-manship under proper product and plumbing specification and application, normal and proper installation, use, service and proper care as published in detail in all service guides included with product. Labor charges are excluded from any warranty
service or repair and are not the responsibility of EWS, Inc. Shipping charges may apply to delivered replacement parts or
materials. Charges may also apply for the cost of any replacement media, resin, cartridges, uv lamp and/or membrane from
any warranty service or repair. Information can be obtained at any time through a local dealer, distributor, representative or direct from EWS, Inc. and/or on-line at; www.ewswater.com. Replacement parts can be obtained from your local dealer, distributor, online or contractor.
This warranty is the exclusive warranty granted by EWS, Inc. and is in lieu of all other warranties of merchantability and fitness
for a particular purpose and is further limited to defective parts replacement only. Labor charges and/or damage incurred in setup, installation, and startup, or repair, or replacement, as well as, incidental and consequential damages connected there with, are excluded, and are not the responsibility of, and will not be paid by EWS, Inc.
This warranty is void for any damages due to improper product and/or plumbing specification and/or application, misuse,
abuse, neglect, accident, acts of nature, action of any military or civil authorities, improper handling and transportation, or improper setup, installation, and/or startup, or any violation of instructions furnished by EWS, Inc., or any replacement parts other than genuine parts or replacements supplied by EWS, Inc.
This warranty is not a warranty of merchantability, fitness, taste, aesthetics, and/or performance that may be subject to im-
proper product and/or plumbing specification and/or application, misuse, abuse, neglect, accident, acts of nature, action of any military or civil authorities, improper handling and transportation, or improper setup, installation, and/or startup, or any violation of instructions furnished by EWS, Inc.
This warranty is not a warranty of merchantability, fitness, taste, aesthetics, and/or performance that may be personal and
of subjective opinion and that does not relate to the performance of any system.
Warranty Notification
19
Keep a record of the purchase receipt and/or installation receipt. Purchaser is required fill out warranty registration form(s)
on applicable product(s) and register all product by either online @ www.ewswater.com, telephone, postal delivery, fax, e-
mail (either register@ewswater.com or information provided to customerservice@ewswater.com). Failure to do so voids the warranty unless restricted by state regulations.
EWS, Inc. does not sell, show or make available any information on any consumer in our database. This database is to
ensure, if needed, proper warranty service, and good customer service for years to come. Please see our privacy policy
published in our website at www.ewswater.com.
Know Your Water:
• If on a municipal system, large or small, it is your right as a consumer to have access to the most recent test results and to
expect adherence to federal guidelines, as well as any state or local requirements. Any problems should be reported to the
appropriate agencies. Please acquire those municipal test results to become an informed consumer.
• If on an individual well, have your water completely and independently tested. Local code may require a simple test for
coliform bacteria to approve a well, however you may be unaware of potential problems for you and/or your home. A local
water salesman is looking to close a sale and is going to test for hardness minerals and a few simple and obvious issues,
which may or may not be contamination problems. Their solution is almost always the same and yet may provide no resolu-tion to any true problems. Obtain our “Guide for the Private Well Owner” on our website; www.ewswater.com. Review our
section on well water testing and applications in our complete catalog with your local distributor, dealer, or our representative
or visit our website.
• WARNING: Some restrictions apply to the use of softeners. Contact your local municipal water district or Gov’t Agency. Brine discharge
is already restricted on, or may be a problem for, septic applications and waste water treatment facilities. Since some states
have already restricted softeners to metered valves to prevent excessive brine discharge, EWS, Inc. only provides metered
valving in its line of softeners.
Restrictions or an outright ban may also apply to hot-side only, salt-exchange tanks or services. Local water dealers and
other organizations do not inform consumers of these issues and believe these rules are unenforcable. The consumer is
ultimately responsible.
Softeners may also provide warranty issues with pools and spas, certain other products and finishes. Softened water should not be used for drinking, cooking, pets or plants and is usually bypassed or “looped away” from the cold side of the kitchen
sink. Reverse osmosis, which also has its drawbacks and issues with other products and materials, may be used to remove
the salt from the water that the softener put in at the kitchen sink, yet may be misapplied for the actual local water conditions.
Any problems of water quality, or the fitness of any EWS, Inc. product that is associated with any mechanical, construction, application, installation, and/or environmental issue(s) (ie: flow rates, line pressure, piping materials, broken supply lines,
changing water conditions; well or municipal water quality, et. al.), known or unknown, of the home or facility will not be
considered by EWS, Inc. until such issue(s) have been resolved.
Responsibility for the proper product and/or plumbing specification, application and/or installation of any device manufactured by EWS, Inc. lies with the consumer, their builder contractor, plumbing sub-contractor and any other installer of choice. Items
do not specify and/or install themselves. EWS, Inc. has provided many sources to acquire information on the proper applica-
tion of systems and their installation prior to any purchase. EWS, Inc. manufactures a complete product line of point of use
water filtration systems and point of entry filtration, softening and/or conditioning systems and/or appliances.
EWS, Inc. and the distributors of EWS, Inc. will stand behind the warranties of materials and workmanship. However, EWS,
Inc. and the distributors of EWS, Inc. and the Environmental Water Systems Product Line do not bear any responsibility for
improper applications of product and/or improper installation. It is for this reason that EWS, Inc. provides complete information
on all product for your understanding, specification, application and selection, and proper plumbing application and installation.
To obtain warranty service support, contact your local dealer or contractor from whom you obtained the product or contact
EWS, Inc., Customer Service, via phone, fax, or email.
Warranty Information and the Purchaser’s Responsibility
20The EWS, Inc./Environmental Water System Product available through:
Contact Information:
EWS, INC.
Environmental Water Systems
Authorized Kitchen & Bath Showrooms, Appliance Showrooms, Building & Plumbing Wholesale Supply Locations
and their building, plumbing, HVAC and service contractors, and Authorized Online Distributors.
ewswater.com O: 702.256.8182 (M-F 8:30am-4:30pm PST)
E: customerservice@ewswater.comF: 702.256.3744
Mailing Address:
9101 W. Sahara Ave., #105-J8, Las Vegas, NV. 89117
Got a Question..?
Seriously.... Give us a call. We’re here to help.
ALL FILTRATION PRODUCT PROUDLY MADE & ASSEMBLED IN THE USA
EWS Logo and Environmental Water Systems are Registered Trademarks and the Property of EWS, Inc.
EWS is a Proud Contributor and Sponsor of Organizations Dedicated to Improving
Health, Well-Being and the Environment
• ••••Heart Lung & Respiratory Allergy & Asthma Dermatology & Skin Digestive: Crohn’s & ColitisOceans Inland Water Ways Wetlands Forestry Soil Air ••••••••