Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B14-0196 Goodman CAPF Coil.pdf
SS-GCoil www.goodmanmfg.com 7/13 Supersedes 1/13 * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. CAUF Uncased CHPF Horizontal “A” CSCF Horizontal Slab CAPF Cased CAPT Cased with Internal TXV I ndoor CoI ls CAUF, CAPF, CAPT, CHPF, And CsCF CAsed, PAInTed UPFlow/downFlow, UnCAsed UPFlow/ downFlow, HorIzonTAl “A”, And HorIzonTAl slAb Indoor CoIls Note: Do not use these coils on oil furnaces or any applications where the tem- perature on the drain pan may exceed 300°F. If these coils are applied with an oil furnace or another application where high temperatures threaten or jeopardize the durability of the drain pan, you must replace the factory- installed drain pan with a high-temperature drain pan. High-temperature drain pan kits are available as field-installed accessories. Standard Features • Piston models suitable for use with R-410A and R-22 refrigerants • Mold-resistant thermoplastic drain pans feature a low water-retention design • Check flowrater expansion device for heat pump or cooling-only applications • Rifled aluminum tubing and louvered aluminum fin coils • Factory-installed TXV in high-efficiency coils for use with R-410A refrigerant • AHRI Certified; ETL Listed Cased Coil Cabinet Features • Galvanized-steel cabinet with leather-grain finish • Foil-face insulation • Architectural Gray paint finish on cased coils • Split-seam front for easy access • 17½”, 21”, and 24½” CHPF coils have one 3½” adapter plate • 17½”, 21”, and 24½” CAPF coils have two 1¾” adapter plates 2 www.goodmanmfg.com SS-GCoil SS-GCoil www.goodmanmfg.com 3 Product SPecificationS Product SPecificationS nomenClATUre Product Category Engineering C Indoor Coil Major/Minor Revisions Applica4on Refrigerant A Upflow/Downflow Coil R-‐22 or R-‐410A H Horizontal A Coil R-‐22 S Horizontal Slab Coil R-‐410A Cabinet Finish Nominal Width for Gas Furnace U Uncased A Fits 14” Furnace Cabinet P Painted B Fits 17½” Furnace Cabinet C Unpainted C Fits 21” Furnace Cabinet D Fits 24½” Furnace Cabinet Expansion Device N Does Not Apply (horizontal slab coil) F Flowrator T TXV Nominal Capacity Range @ 13 SEER 1½ to 2 Tons 2½ Tons 3 to 3½ Tons 6 2 4 1824 3030 3642 101 C U 3 6 11,12 AAA 2 1824 5,6,7,8 F 4 9 A 2www.goodmanmfg.comSS-GCoil SS-GCoil www.goodmanmfg.com 3 Product SPecificationS Product SPecificationS CAUF — UnCAsed UPFlow/downFlow Indoor CoIls dImensIons W H Suction Connection Liquid Connection ¾” Female NPT primary & secondary drain connections (Important: hand-tighten) 20⅛” 3” A 2.3” sPeCIFICATIons Model Dimensions Nominal Tons Connection Piston Size* Ship Weight (lbs)W H A Liquid Suction CAUF1824A6 13”16¼" 13"1½-2 ⅜”¾” .059 18 CAUF1824B6 16½”16⅛" 13"1½-2 ⅜”¾” .059 23 CAUF1824C6 20”16⅜" 17"1½-2 ⅜”¾” .059 27 CAUF3030A6 13"20¹/₁₆" 17"2½⅜”¾” .065 25 CAUF3030B6 16½” 18¾" 17"2½⅜”¾” .065 22 CAUF3030C6 20”17⅞" 17"2½⅜”¾” .065 25 CAUF3030D6 23”17⅞" 17"2½⅜”¾” .065 32 CAUF3131B6 16½”20¹/₁₆" 17"2½⅜”¾” .068 27 CAUF3131C6 20”20"17"2½⅜”¾” .068 31 CAUF3636A6 13" 19½" 17 3 ⅜”¾” .071 30 CAUF3636B6 16½”19⅜"17 3 ⅜”¾” .071 25 CAUF3636C6 20”19⅛"17 3 ⅜”¾” .071 28 CAUF3636D6 23"19⅛"17 3 ⅜”¾” .071 36 CAUF3642C6 20”19"17 3-3½⅜”¾” .078 29 CAUF3642D6 23”19⅞"17 3-3½⅜”¾” .078 34 CAUF3743C6 20”28¹/₁₆" 25"3-3½⅜”⅞”.078 46 CAUF3743D6 23”27⅜" 25"3-3½⅜”⅞”.078 43 CAUF4860C6 20”28"25"4-5 ⅜”⅞”.093 48 CAUF4860D6 23”28"25"4-5 ⅜”⅞”.093 39 CAUF4961C6 20”28"25"4-5 ⅜”⅞”.093 54 CAUF4961D6 23”27"25"4-5 ⅜”⅞”.093 59 * Shipped with Coil Note: For a properly matched system and piston sizing information, refer to Goodman piston kit chart of the corresponding Goodman® outdoor unit. 4 www.goodmanmfg.com SS-GCoil SS-GCoil www.goodmanmfg.com 5 Product SPecificationS Product SPecificationS CAPF — CAsed UPFlow/downFlow Indoor CoIls dImensIons Plenum Opening Width Plenum Opening Width 20⅛” 1⅝”⅝”Suction Connection Liquid Connection 19” ¾” Female NPT primary & secondary drain connections (Important: hand-tighten) 3” ½”½” sPeCIFICATIons Model Cabinet Dimensions Nominal Tons Connection PistonSize*Ship Weight (lbs)W D H Liquid Suction CAPF1824A6 14” 21” 18” 1½-2 ⅜”¾” .059 32 CAPF1824B6 17½” 21” 18” 1½-2 ⅜”¾” .059 35 CAPF1824C6 21” 21” 22” 1½-2 ⅜”¾” .059 42 CAPF3030A6 14" 21" 22" 2½⅜”¾” .065 41 CAPF3030B6 17½” 21” 22” 2½⅜”¾” .065 43 CAPF3030C6 21” 21” 22” 2½⅜”¾” .065 44 CAPF3030D6 24½” 21” 22” 2½⅜”¾” .065 52 CAPF3131B6 17½” 21” 22” 2½⅜”¾” .068 46 CAPF3131C6 21” 21” 22” 2½⅜”¾” .068 50 CAPF3636A6 14" 21" 22"3 ⅜”¾” .071 40 CAPF3636B6 17½” 21” 22"3 ⅜”¾” .071 44 CAPF3636C6 21” 21” 22"3 ⅜”¾” .071 53 CAPF3636D6 24½" 21" 22"3 ⅜”¾” .071 51 CAPF3642C6 21” 21” 22" 3-3½⅜”¾” .078 49 CAPF3642D6 24½” 21” 22" 3-3½⅜”¾” .078 52 CAPF3743C6 21” 21” 30” 3-3½⅜”⅞”.078 63 CAPF3743D6 24½” 21” 30” 3-3½⅜”⅞”.078 75 CAPF4860C6 21” 21” 30” 4-5 ⅜”⅞”.093 65 CAPF4860D6 24½” 21” 30” 4-5 ⅜”⅞”.093 68 CAPF4961C6 21” 21” 30” 4-5 ⅜”⅞”.093 73 CAPF4961D6 24½” 21” 30” 4-5 ⅜”⅞”.093 76 * Shipped with Coil Note: For a properly matched system and piston sizing information, refer to Goodman piston kit chart of the corresponding Goodman® outdoor unit. 4www.goodmanmfg.comSS-GCoil SS-GCoil www.goodmanmfg.com 5 Product SPecificationS Product SPecificationS CAPT — CAsed UPFlow/downFlow Indoor CoIls wITH InTernAl TXV dImensIons sPeCIFICATIons Model Cabinet Dimensions Nominal Tons Connection Ship Weight (lbs)W D H Liquid Suction CAPT3131B4 17½” 21” 22” 2½⅜”¾” 46 CAPT3131C4 21” 21” 22” 2½⅜”¾” 50 CAPT3743C4 21” 21” 30” 3-3½⅜” ⅞”63 CAPT3743D4 24½” 21” 30” 3-3½⅜” ⅞”75 CAPT4961C4 21” 21” 30” 4-5 ⅜” ⅞”73 CAPT4961D4 24½” 21” 30” 4-5 ⅜” ⅞”76 6 www.goodmanmfg.com SS-GCoil SS-GCoil www.goodmanmfg.com 7 Product SPecificationS Product SPecificationS CHPF — CAsed HorIzonTAl “A” Indoor CoIl dImensIons Note: All air opening flanges are 0.6250”. Primary Drain Secondary Drain Liquid Line Suction Line Drain Pan Coil W D H Plenum Opening Width sPeCIFICATIons Model Cabinet Dimensions Plenum Nominal Tons Evap Coil Face Area¹ Coil Dimensions Connection PistonSize² Ship Weight (lbs)W D H W H W H Liquid Suction CHPF1824A6 21⅛”26” 14” 19” 13” 1½-2 3⅓ 20⅛”12”⅜”¾” .059 36 CHPF2430B6 21⅛”26” 17½” 19” 16½” 2-2½ 4½20⅛”16”⅜”¾” .065 55 CHPF3636B6 21⅛”26” 17½” 19” 16½” 3 4⅓19½” 16”⅜”¾” .074 50 CHPF3642C6 21⅛”26” 21” 19” 20” 3-3½4⅓19½” 16”⅜”¾” .076 63 CHPF3642D6 21⅛”26” 24½” 19” 23½” 3-3½ 6 19½” 22”⅜” ⅞”.078 66 CHPF3743C6 21⅛”26” 21” 19” 20” 3-3½4⅓19½” 16”⅜” ⅞”.076 63 CHPF3743D6 21⅛”26” 24½” 19” 23½” 3-3½ 6 19½” 22”⅜” ⅞”.078 63 CHPF4860D6 21⅛”26” 24½” 19” 23½” 4-5 6 19½” 22”⅜” ⅞”.093 77 ¹ (ft²) ² Shipped with Coil Note: For a properly matched system and piston sizing information, refer to Goodman piston kit chart of the corresponding Goodman® outdoor unit. 6www.goodmanmfg.comSS-GCoil SS-GCoil www.goodmanmfg.com 7 Product SPecificationS Product SPecificationS dImensIons CsCF — HorIzonTAl slAb eVAPorATor CoIls Model Cabinet Dimensions Plenum Opening C Width Coil Dimensions W (A)D H W (B)H W H CSCF1824N6 25½” 12” 25” 16” 21” 6” 19¾” 24” CSCF3036N6 33½” 12” 25” 24” 21” 6” 28” 24” CSCF3642N6 39½” 12” 25” 30” 21” 6” 34” 24” CSCF4860N6 39½” 12” 25” 30” 21” 6” 34” 24” sPeCIFICATIons Model Capacity (Tons) Evap Coil Face Area¹ Connection Size Piston Size² Ship Weight (lbs)Liquid Suction CSCF1824N6 1½-2 3⅓⅜"¾".059 43 CSCF3036N6 2½-3 4⅔⅜"⅞".074 52.5 CSCF3642N6 3-3½5⅔⅜"⅞".078 43 CSCF4860N6 4-5 5⅔⅜"⅞".093 60 ¹ (ft²) ² Shipped with Coil Note: For a properly matched system and piston sizing information, refer to Goodman piston kit chart of the corresponding Goodman® outdoor unit. Detail of Access Door -----Original Message----- From: Morris, Chris Sent: Thursday, March 30, 2006 8:47 AM To: Perry, Stephen Cc: Fine, Barth Subject: RE: SS-GCoil Stephen, The unit graphic you have below looks like an Amana Horizontal Slab Coil. I found some H Coil specs and changed them into CSCF specs. I do not have Adobe Page Writer, so I couldn’t add the dimensions for the tubing and drain openings. I have copied a snapshot of the access door drawing that has those dimensions below. Here are the specs you requested. 8 www.goodmanmfg.com SS-GCoil SS-GCoil www.goodmanmfg.com 9 Product SPecificationS Product SPecificationS AIrFlow dATA For CAUF & CAPF AIr QUAnTITy (sCFm) Vs. PressUre droP (In. wC)SCFM 400 500 600 700 800 900 1000 1100 1200CA*F1824A6*Wet0.071 0.099 0.142 0.183 0.230 0.280 0.331 0.389 ---Dry 0.062 0.090 0.122 0.154 0.189 0.231 0.278 0.331 0.390CA*F1824B6*Wet0.021 0.032 0.049 0.071 0.089 0.120 0.128 0.159 0.190Dry 0.011 0.022 0.029 0.041 0.052 0.069 0.078 0.101 0.120CA*F1824C6*Wet0.017 0.025 0.043 0.061 0.079 0.107 0.114 0.140 0.164Dry 0.011 0.017 0.024 0.035 0.044 0.063 0.075 0.094 0.113SCFM 600 700 800 900 1000 1100 1200 1300 1400 1500CA*F3030A6*Wet0.151 0.173 0.204 0.238 0.267 0.281 0.326 0.380 0.406 0.451Dry 0.069 0.083 0.117 0.132 0.148 0.183 0.206 0.239 0.290 0.338CA*F3030B6*Wet0.090 0.120 0.150 0.180 0.210 0.240 0.280 0.330 0.370 0.420Dry 0.080 0.100 0.130 0.150 0.180 0.210 0.250 0.280 0.320 0.360CA*F3030C6*Wet0.071 0.087 0.120 0.134 0.155 0.180 0.209 0.249 0.284 0.328Dry 0.050 0.067 0.098 0.113 0.135 0.169 0.189 0.213 0.245 0.275CA*F3030D6*Wet0.069 0.060 0.090 0.108 0.136 0.168 0.206 0.244 0.288 0.337Dry 0.029 0.043 0.070 0.082 0.098 0.125 0.141 0.153 0.177 0.200SCFM 600 700 800 900 1000 1100 1200 1300 1400 1500 1600CA*F3131B26*Wet0.041 0.049 0.061 0.078 0.090 0.113 0.131 0.140 0.162 0.178 0.210Dry 0.021 0.031 0.039 0.048 0.061 0.072 0.079 0.091 0.110 0.122 0.141CA*F3131C6*Wet0.035 0.034 0.038 0.051 0.059 0.073 0.087 0.094 0.110 0.125 0.145Dry 0.014 0.022 0.028 0.036 0.045 0.054 0.061 0.068 0.081 0.091 0.108SCFM 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200CA*F3636A6*Wet0.13 0.17 0.220 0.280 0.310 0.380 0.450 0.530 0.610 0.690 0.790 0.870 0.910 0.950 1.030 1.130 1.190Dry 0.13 0.16 0.200 0.230 0.280 0.320 0.380 0.450 0.520 0.590 0.670 0.710 0.790 0.870 0.970 1.060 1.160CA*F3636B6*Wet0.11 0.13 0.160 0.180 0.220 0.260 0.300 0.350 0.400 0.460 0.520 0.570 0.600 0.660 0.720 0.790 0.850Dry 0.11 0.13 0.160 0.170 0.210 0.240 0.270 0.330 0.370 0.420 0.470 0.520 0.550 0.610 0.660 0.720 0.770CA*F3636C6*Wet0.1 0.12 0.160 0.170 0.210 0.250 0.290 0.340 0.380 0.430 0.480 0.540 0.550 0.610 0.670 0.720 0.780Dry 0.09 0.11 0.130 0.140 0.160 0.180 0.220 0.250 0.280 0.320 0.350 0.370 0.410 0.450 0.490 0.530 0.570CA*F3636D6*Wet0.08 0.11 0.130 0.140 0.170 0.200 0.230 0.270 0.310 0.350 0.390 0.430 0.460 0.500 0.560 0.620 0.660Dry 0.09 0.11 0.130 0.140 0.160 0.190 0.220 0.240 0.270 0.300 0.340 0.380 0.4100.440 0.490 0.530 0.580 8www.goodmanmfg.comSS-GCoil SS-GCoil www.goodmanmfg.com 9 Product SPecificationS Product SPecificationS SCFM 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200CA*F3642C6*Wet0.07 0.09 0.110 0.120 0.140 0.170 0.200 0.230 0.260 0.290 0.330 0.360 0.380 0.420 0.460 0.500 0.540Dry 0.07 0.08 0.100 0.110 0.130 0.150 0.170 0.200 0.230 0.250 0.280 0.310 0.330 0.370 0.400 0.430 0.470CA*F3642D6*Wet0.07 0.09 0.110 0.110 0.140 0.160 0.190 0.210 0.240 0.270 0.300 0.330 0.350 0.380 0.420 0.460 0.480Dry 0.06 0.08 0.090 0.100 0.110 0.130 0.150 0.170 0.190 0.220 0.240 0.260 0.280 0.300 0.330 0.360 0.390SCFM 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200CA*F3743C6*Wet0.083 0.093 0.113 0.133 0.143 0.163 0.183 0.213 0.243 0.263 0.293 0.323 0.353 0.383 0.423Dry 0.073 0.083 0.103 0.113 0.133 0.153 0.163 0.193 0.213 0.233 0.263 0.293 0.313 0.343 0.373CA*F3743D6*Wet0.074 0.080 0.089 0.107 0.120 0.129 0.138 0.169 0.188 0.209 0.229 0.251 0.273 0.279 0.306Dry 0.046 0.056 0.074 0.076 0.086 0.107 0.110 0.126 0.147 0.160 0.176 0.196 0.210 0.230 0.253SCFM 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200CA*F4860C6*Wet0.167 0.175 0.191 0.244 0.266 0.299 0.355 0.370 0.413 0.454 0.498 0.586 0.601Dry 0.160 0.157 0.194 0.206 0.246 0.264 0.220 0.265 0.290 0.309 0.364 0.389 0.562CA*F4860D6*Wet0.138 0.156 0.177 0.196 0.226 0.247 0.275 0.298 0.327 0.349 0.395 0.460 0.485Dry 0.126 0.138 0.157 0.176 0.187 0.200 0.180 0.210 0.230 0.250 0.280 0.300 0.417SCFM 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200CA*F4961C6*Wet0.209 0.217 0.233 0.286 0.308 0.341 0.397 0.412 0.455 0.496 0.540 0.628 0.643Dry 0.202 0.199 0.236 0.248 0.288 0.306 0.262 0.307 0.332 0.351 0.406 0.431 0.604CA*F4961D6*Wet0.140 0.158 0.179 0.198 0.228 0.249 0.277 0.300 0.329 0.351 0.397 0.462 0.487Dry 0.128 0.140 0.159 0.178 0.189 0.202 0.182 0.212 0.232 0.252 0.282 0.302 0.419 AIrFlow dATA For CAUF & CAPF (ConT.) AIr QUAnTITy (sCFm) Vs. PressUre droP (In. wC) 10 www.goodmanmfg.com SS-GCoil SS-GCoil www.goodmanmfg.com 11 Product SPecificationS Product SPecificationS AIrFlow dATA For CAPT AIr QUAnTITy (sCFm) Vs. PressUre droP (In. wC)SCFM 600 700 800 900 1000 1100 1200 1300 1400 1500 1600CAPT3131B4*Wet0.041 0.049 0.061 0.078 0.090 0.113 0.131 0.140 0.162 0.178 0.210Dry 0.021 0.031 0.039 0.048 0.061 0.072 0.079 0.091 0.110 0.122 0.141CAPT3131C4*Wet0.035 0.034 0.038 0.051 0.059 0.073 0.087 0.094 0.110 0.125 0.145Dry 0.014 0.022 0.028 0.036 0.045 0.054 0.061 0.068 0.081 0.091 0.108SCFM 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200CAPT3743C4*Wet0.083 0.093 0.113 0.133 0.143 0.163 0.183 0.213 0.243 0.263 0.293 0.323 0.353 0.383 0.423Dry 0.073 0.083 0.103 0.113 0.133 0.153 0.163 0.193 0.213 0.233 0.263 0.293 0.313 0.343 0.373CAPT3743D4*Wet0.074 0.080 0.089 0.107 0.120 0.129 0.138 0.169 0.188 0.209 0.229 0.251 0.273 0.279 0.306Dry 0.046 0.056 0.074 0.076 0.086 0.107 0.110 0.126 0.147 0.160 0.176 0.196 0.210 0.230 0.253SCFM 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200CAPT4961C4*Wet0.209 0.217 0.233 0.286 0.308 0.341 0.397 0.412 0.455 0.496 0.540 0.628 0.643Dry 0.202 0.199 0.236 0.248 0.288 0.306 0.262 0.307 0.332 0.351 0.406 0.431 0.604CAPT4961D4*Wet0.140 0.158 0.179 0.198 0.228 0.249 0.277 0.300 0.329 0.351 0.397 0.462 0.487Dry 0.128 0.140 0.159 0.178 0.189 0.202 0.182 0.212 0.232 0.252 0.282 0.302 0.419 10www.goodmanmfg.comSS-GCoil SS-GCoil www.goodmanmfg.com 11 Product SPecificationS Product SPecificationS AIrFlow dATA For CHPF AIr QUAnTITy (sCFm) Vs. PressUre droP (In. wC) SCFM 600 700 800 900 1000 1100 1200 1300 1400 CHPF 1824A6* Wet 0.132 0.179 0.222 0.272 0.327 0.381 0.456 0.522 0.605 Dry 0.126 0.165 0.206 0.249 0.302 0.354 0.414 0.478 0.563 SCFM 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 CHPF 2430B6* Wet 0.106 0.124 0.152 0.184 0.218 0.258 0.301 0.350 0.406 0.460 0.514 Dry 0.101 0.122 0.145 0.174 0.209 0.247 0.288 0.333 0.381 0.428 0.484 SCFM 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 CHPF 3636B6* Wet 0.107 0.131 0.167 0.199 0.239 0.291 0.338 0.389 0.439 0.494 0.552 Dry 0.102 0.126 0.152 0.184 0.220 0.259 0.303 0.349 0.401 0.458 0.516 SCFM 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 CHPF 3642C6* Wet 0.083 0.103 0.126 0.151 0.178 0.208 0.240 0.274 0.310 0.346 0.383 --- --- --- --- Dry 0.073 0.096 0.120 0.144 0.169 0.196 0.224 0.254 0.286 0.319 0.354 --- --- --- --- CHPF 3642D6* Wet 0.030 0.040 0.040 0.050 0.060 0.070 0.080 0.080 0.090 0.100 0.110 0.130 0.140 0.150 0.160 Dry 0.040 0.050 0.060 0.070 0.080 0.080 0.090 0.100 0.110 0.120 0.120 0.120 0.150 0.160 0.180 SCFM 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 CHPF 3743C6* Wet 0.133 0.153 0.176 0.201 0.228 0.258 0.290 0.324 0.360 0.396 0.433 --- --- --- --- Dry 0.123 0.146 0.170 0.194 0.219 0.246 0.274 0.304 0.336 0.369 0.404 --- --- --- --- CHPF 3743D6* Wet 0.101 0.105 0.115 0.125 0.145 0.165 0.185 0.215 0.235 0.265 0.295 0.315 0.355 0.375 0.405 Dry 0.072 0.095 0.105 0.115 0.135 0.155 0.185 0.205 0.225 0.255 0.275 0.305 0.335 0.365 0.395 SCFM 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 CHPF 4860D6* Wet 0.101 0.121 0.131 0.161 0.181 0.201 0.231 0.261 0.291 0.321 0.361 0.391 0.431 0.471 Dry 0.101 0.121 0.141 0.161 0.181 0.201 0.221 0.251 0.281 0.311 0.341 0.371 0.411 0.441 AIrFlow dATA For CsCF AIr QUAnTITy (sCFm) Vs. PressUre droP (In. wC) CSCF18 24N6D* SCFM 500 600 700 800 900 1000 1100 1200 Wet 0.104 0.143 0.176 0.212 0.255 0.292 0.321 0.344 Dry 0.048 0.067 0.086 0.108 0.132 0.159 0.186 0.206 CSCF30 36N6D* SCFM 700 800 900 1000 1100 1200 1300 1400 Wet 0.062 0.076 0.092 0.109 0.131 0.156 0.186 0.209 Dry 0.032 0.043 0.055 0.068 0.082 0.099 0.114 0.131 CSCF36 42N6D* SCFM 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 Wet 0.045 0.063 0.081 0.099 0.116 0.132 0.148 0.166 0.183 0.202 0.22 0.236 0.259 0.278 0.291 Dry 0.039 0.051 0.064 0.077 0.092 0.105 0.121 0.138 0.15 0.175 0.191 0.214 0.23 0.251 0.262 CSCF48 60N6D* SCFM 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 Wet 0.051 0.068 0.085 0.103 0.12 0.137 0.154 0.173 0.192 0.212 0.233 0.255 0.278 0.299 0.319 Dry 0.043 0.056 0.069 0.084 0.099 0.115 0.132 0.149 0.167 0.185 0.207 0.227 0.249 0.272 .282** ** Maximum SCFM = 2146 12 www.goodmanmfg.com SS-GCoil SS-GCoil www.goodmanmfg.com PB Product SPecificationS Product SPecificationS Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2013 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. ACCessorIes HIgH-TemP drAIn PAn KITs Drain Pan Kits Furnace Size HTP-A 14” furnaces HTP-B 17½” furnaces HTP-C 21” furnaces HTP-D 24½” furnaces eXPAnsIon VAlVe KITs For non-TXV CoIls Kit Number Description Application Refrigerant Tonnage: Outdoor Unit XVB18-36C 20% Bleed Valve AC Only R-22 1½ - 3 Ton XVB42-60C 20% Bleed Valve AC Only R-22 3½ - 5 Ton XV18-36C Non-bleed Valve AC Only R-22 1½ - 3 Ton XV42-60C Non-bleed Valve AC Only R-22 3½ - 5 Ton TX2N2 Non-bleed Valve AC or HP R-22 1½ - 2 Ton TX3N2 Non-bleed Valve AC or HP R-22 2½ - 3 Ton TX5N2 Non-bleed Valve AC or HP R-22 3½ - 5 Ton TX2N4A Non-bleed Valve AC or HP R-410A 1½ - 2 Ton TX3N4 Non-bleed Valve AC or HP R-410A 2½ - 3 Ton TX5N4 Non-bleed Valve AC or HP R-410A 3½ - 5 Ton Note: Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil us- ing a non-bleed thermal expansion valve refrigerant metering device.