Loading...
HomeMy WebLinkAboutB14-0196 Goodman GSX13.pdfSS-GSX13 www.goodmanmfg.com 3/14 Supersedes 2/14A GSX13 Split SyStem Air Conditioner 13 Seer / 1½ to 5 tonS CoolinG CApACity: 18,000 - 60,000 BtU/h Standard Features • R-410A chlorine-free refrigerant • Energy-efficient compressor • Factory-installed filter drier • Copper tube/aluminum fin coil • Service valves with sweat connections and easy-access gauge ports • Contactor with lug connection • Ground lug connection • AHRI Certified • ETL Listed Cabinet Features • Goodman® brand louvered sound control top design • Steel louver coil guard • Heavy-gauge galvanized-steel cabinet • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval • Top and side maintenance access • Single-panel access to controls with space provided for field-installed accessories • When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.) * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration not required in California or Québec. Contents Nomenclature .......................................2 Product Specifications ..........................3 Expanded Cooling Data ........................4 AHRI Ratings ........................................22 Dimensions .........................................39 Wiring Diagrams ................................40 Accessories ..........................................44 Product SPecificationS 2 www.goodmanmfg.com SS-GSX13 nomenClAtUre Brand Engineering * G Goodman® Brand or Minor Revision Amana® Distinctions® Brand Engineering * Major Revision Product Category Electrical S Split System 1 208-230 V, 1 Phase, 60 Hz 2 220/240 V, 1 Phase, 50 Hz Unit Type 3 208-230 V, 3 Phase, 60 Hz C Condenser R-22 4 460 V, 3 Phase, 60 Hz X Condenser R-410A 5 380-415 V, 3 Phase, 50 Hz H Heat Pump R-22 Z Heat Pump R-410A Nominal Capacity 018 1½ Tons 048 4 Tons Efficiency 024 2 Tons 060 5 Tons 13 13 SEER 030 2½ Tons 090 7½ tons 14 14 SEER 036 3 Tons 120 10 Tons 042 3½ Tons * Neither used for order entry or inventory management. 101 G X 3 * 11 *S 2 036 6,7,8 13 4,5 9 1 Product SPecificationS SS-GSX13 www.goodmanmfg.com 3 SpeCifiCAtionS GSX13 0181E* GSX13 0241D* GSX13 0301B* GSX13 0361C* GSX13 0361E* GSX13 0421B* GSX13 0481B* GSX13 0601B* GSX13 0611A* Capacities Nominal Cooling (BTU/h)18,000 24,000 30,000 36,000 36,000 42,000 48,000 60,000 60,000 SEER / EER 13 / 11 13 / 11 13 / 11 13 / 11 13 / 11 13 / 11 13 / 11 13 / 11 13/11 Decibels 75 75 73 74 74 75 76 77 72 Compressor RLA 6.7 13.5 12.8 14.1 14.1 17.9 19.9 25.0 26.4 LRA 41 58.3 64 77 77 112 109 134 134 Condenser Fan Motor Horsepower 1/8 1/8 1/8 1/6 1/4 1/4 1/4 1/4 1/4 FLA 0.7 0.7 0.7 1.1 1.5 1.5 1.5 1.5 1.5 Refrigeration System Refrigerant Line Size ¹ Liquid Line Size (“O.D.)⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction Line Size (“O.D.)¾" ¾" ¾" ⅞" ⅞" 1⅛" 1⅛" 1⅛" ⅞" Refrigerant Connection Size Liquid Valve Size (“O.D.)⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction Valve Size (“O.D.) ⁴ ⁵¾" ¾" ¾" ¾" ⁴ ¾" ⁴ ⅞" ⁵ ⅞" ⁵ ⅞" ⁵ ¾" Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Refrigerant Charge 73 76 78 89 75 90 104 111 130 Shipped with Orifice Size 0.051 0.057 0.061 0.070 0.070 0.076 0.080 0.086 0.086 Electrical Data Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Minimum Circuit Ampacity ² 9.1 17.6 16.7 18.7 19.1 23.9 26.4 32.8 34.5 Max. Overcurrent Protection ³15 amps 30 amps 25 amps 30 amps 30 amps 40 amps 45 amps 50 amps 60 amps Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" Equipment Weight (lbs)102 115 115 139 118 171 175 184 211 Ship Weight (lbs)117 128 132 157 135 189 193 202 233 ¹ Line sizes denoted for 25’ line sets, tested and rated in accordance with AHRI Standard 210/240. For other line-set lengths or sizes, refer to the installation & Operating instructions and/or the long line-set guidelines. ² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. ⁴ Installer will need to supply ¾” to ⅞” adapters for suction line connections. ⁵ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections. Notes • Always check the S&R plate for electrical data on the unit being installed. • Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. Product SPecificationS 4 www.goodmanmfg.com SS-GSX13 eXpAnded CoolinG dAtA — GSX130181e* / CApf1824B6dB Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 7170525MBh 15.6 16.2 17.7 - 15.3 15.8 17.3 - 14.9 15.4 16.9 - 14.5 15.1 16.5 - 13.8 14.3 15.7 - 12.8 13.3 14.5 -S/T 0.70 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.62 0.43 - 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.81 0.67 0.47 -∆ T19.3 16.7 12.7 - 19.5 16.9 12.8 - 19.5 16.9 12.8 - 19.6 17.0 12.9 - 19.4 16.8 12.7 - 18.1 15.7 11.9 -kW1.02 1.04 1.08 - 1.11 1.13 1.17 - 1.18 1.21 1.25 - 1.25 1.28 1.32 - 1.30 1.33 1.38 - 1.35 1.38 1.43 -Amps 4.3 4.4 4.5 - 4.6 4.7 4.9 - 5.0 5.1 5.3 - 5.4 5.5 5.7 - 5.7 5.8 6.0 - 6.0 6.2 6.4 -Hi PR 203 219 231 - 228 245 259 - 259 279 294 - 295 318 335 - 332 357 377 - 367 395 417 -Lo PR 102 109 119 - 108 115 126 - 113 120 131 - 118 126 137 - 124 132 144 - 128 136 149 -600MBh 16.4 17.0 18.7 - 16.0 16.6 18.2 - 15.7 16.2 17.8 - 15.3 15.8 17.4 - 14.5 15.0 16.5 - 13.4 13.9 15.3 -S/T 0.71 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.82 0.69 0.47 -∆ T18.0 15.6 11.8 - 18.2 15.8 12.0 - 18.2 15.8 12.0 - 18.4 15.9 12.1 - 18.1 15.7 11.9 - 16.9 14.6 11.1 -kW1.03 1.06 1.09 - 1.12 1.14 1.18 - 1.19 1.22 1.27 - 1.26 1.29 1.34 - 1.32 1.35 1.40 - 1.37 1.40 1.45 -Amps 4.3 4.4 4.6 - 4.7 4.8 4.9 - 5.1 5.2 5.4 - 5.4 5.6 5.7 - 5.8 5.9 6.1 - 6.1 6.3 6.5 -Hi PR 206 221 234 - 231 248 262 - 263 283 298 - 299 322 340 - 336 362 382 - 372 400 422 -Lo PR 104 110 121 - 110 117 127 - 114 121 132 - 120 127 139 - 126 134 146 - 130 138 151 -650MBh 16.9 17.6 19.2 - 16.5 17.1 18.8 - 16.1 16.7 18.3- 15.8 16.3 17.9 - 15.0 15.5 17.0 - 13.9 14.4 15.7 -S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.84 0.70 0.48 -∆ T17.5 15.1 11.5 - 17.7 15.3 11.6 - 17.7 15.3 11.6 - 17.8 15.4 11.7 - 17.6 15.2 11.6 - 16.4 14.2 10.8 -kW1.05 1.07 1.11 - 1.14 1.16 1.20 - 1.21 1.24 1.29 - 1.28 1.31 1.36 - 1.34 1.37 1.42 - 1.39 1.42 1.47 -Amps 4.44.54.6 - 4.7 4.9 5.0 - 5.2 5.3 5.5 - 5.5 5.6 5.8 - 5.9 6.0 6.2 - 6.2 6.4 6.6 -Hi PR 209 225 238 - 235 253 267 - 267 287 304 - 304 327 346 - 342 368 389 - 378 407 430 -Lo PR 106 112 123 - 112 119 130 - 116 123 135 - 122 130 142 - 128 136 148 - 132 141 153 -75525MBh 15.9 16.4 17.7 19.0 15.5 16.0 17.3 18.6 15.2 15.6 16.9 18.1 14.815.216.5 17.7 14.0 14.5 15.7 16.8 13.0 13.4 14.5 15.6S/T 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.880.780.59 0.38 0.91 0.81 0.62 0.40 0.92 0.82 0.62 0.40∆ T22.3 20.5 16.8 11.6 22.5 20.7 17.0 11.7 22.6 20.8 17.0 11.7 22.720.917.1 11.8 22.4 20.6 16.9 11.7 20.9 19.3 15.8 10.9kW1.03 1.05 1.09 1.13 1.12 1.14 1.18 1.22 1.19 1.22 1.26 1.31 1.261.291.33 1.38 1.32 1.35 1.39 1.44 1.36 1.40 1.45 1.50Amps 4.3 4.4 4.6 4.7 4.7 4.8 4.9 5.1 5.1 5.2 5.4 5.6 5.45.55.7 5.9 5.8 5.9 6.1 6.3 6.1 6.3 6.5 6.7Hi PR 205 221 233 243 230 248 262 273 262 282 297 310 298321339 353 335 361 381 398 371 399 421 439Lo PR 104 110 120 128 109 116 127 135 114 121 132 141 119127139 148 125 133 145 155 129 138 150 160600MBh 16.7 17.2 18.6 20.0 16.3 16.8 18.2 19.5 15.9 16.4 17.8 19.1 15.516.017.3 18.6 14.8 15.2 16.5 17.7 13.7 14.1 15.2 16.4S/T 0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.37 0.86 0.77 0.58 0.38 0.890.800.60 0.39 0.92 0.83 0.63 0.40 0.93 0.83 0.63 0.41∆ T20.8 19.1 15.7 10.8 21.0 19.4 15.9 11.021.1 19.4 15.9 11.0 21.219.516.0 11.1 20.9 19.3 15.8 10.9 19.5 18.0 14.7 10.2kW1.04 1.07 1.10 1.14 1.13 1.16 1.20 1.24 1.21 1.23 1.28 1.32 1.271.301.35 1.40 1.33 1.36 1.41 1.46 1.38 1.41 1.46 1.52Amps 4.44.54.6 4.8 4.7 4.8 5.0 5.2 5.1 5.2 5.4 5.6 5.55.65.8 6.0 5.8 6.0 6.2 6.4 6.2 6.3 6.5 6.8Hi PR 208 224 236 246 233 251 265 276 265 285 301 314 302325343 358 340 366 386 403 376 404 427 445Lo PR 105 112 122 130 111 118 129 137 115 123 134 142 121129141 150 127 135 147 157 131 140 152 162650MBh 17.2 17.7 19.2 20.6 16.8 17.3 18.7 20.1 16.4 16.9 18.3 19.6 16.016.517.9 19.2 15.2 15.7 17.0 18.2 14.1 14.5 15.7 16.9S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.910.810.62 0.40 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41∆ T20.2 18.6 15.2 10.5 20.4 18.8 15.4 10.7 20.5 18.8 15.4 10.7 20.619.015.5 10.7 20.3 18.7 15.3 10.6 19.0 17.5 14.3 9.9kW1.06 1.08 1.12 1.16 1.15 1.17 1.21 1.26 1.22 1.25 1.30 1.34 1.291.321.37 1.42 1.35 1.38 1.43 1.48 1.40 1.44 1.49 1.54Amps 4.4 4.5 4.7 4.9 4.8 4.9 5.1 5.3 5.2 5.3 5.5 5.7 5.65.75.9 6.1 5.9 6.1 6.3 6.5 6.3 6.4 6.6 6.9Hi PR 211 228 240 251 237 255 270 281 270 290 307 320 307331349 364 346 372 393 410 382 411 434 453Lo PR 107 114 124 132 113 120 131 139 117 125 136 145 123131143 152 129 137 150 160 133 142 155 165IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects ACCA (TVA) conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS SS-GSX13 www.goodmanmfg.com 5 eXpAnded CoolinG dAtA — GSX130181e* / CApf1824B6dB (Cont.)Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 7180525MBh 16.2 16.5 17.7 18.9 15.8 16.1 17.3 18.4 15.4 15.8 16.8 18.0 15.0 15.4 16.4 17.6 14.3 14.6 15.6 16.7 13.2 13.5 14.5 15.5S/T 0.88 0.82 0.67 0.50 0.91 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.94 0.76 0.57 1.01 0.94 0.77 0.57∆ T24.8 23.8 20.7 16.5 25.2 24.1 21.0 16.7 25.2 24.1 21.0 16.8 25.4 24.3 21.1 16.9 25.0 24.0 20.8 16.6 23.4 22.4 19.5 15.5kW1.04 1.06 1.10 1.14 1.13 1.15 1.19 1.23 1.20 1.23 1.27 1.32 1.27 1.30 1.35 1.39 1.33 1.36 1.41 1.46 1.38 1.41 1.46 1.51Amps 4.3 4.4 4.6 4.8 4.7 4.8 5.0 5.2 5.1 5.2 5.4 5.6 5.5 5.6 5.8 6.0 5.8 6.0 6.2 6.4 6.2 6.3 6.5 6.8Hi PR 207 223 235 246 232 250 264 276 264 285 300 313 301 324 342 357 339 365 385 402 374 403 425 444Lo PR 105 111 121 129 110 118 128 137 115 122 133 142 121 128 140 149 126 134 147 156 131 139 152 162600MBh 17.0 17.4 18.6 19.8 16.6 17.0 18.1 19.4 16.2 16.6 17.7 18.9 15.8 16.217.318.5 15.0 15.4 16.4 17.5 13.9 14.2 15.2 16.2S/T 0.89 0.84 0.68 0.51 0.92 0.87 0.70 0.53 0.95 0.89 0.72 0.54 0.98 0.920.750.56 1.00 0.95 0.77 0.58 1.00 0.96 0.78 0.58∆ T23.2 22.2 19.3 15.5 23.5 22.5 19.6 15.6 23.5 22.5 19.6 15.7 23.7 22.719.715.8 23.0 22.4 19.5 15.5 21.3 20.9 18.2 14.5kW1.05 1.08 1.11 1.15 1.14 1.17 1.21 1.25 1.22 1.25 1.29 1.33 1.28 1.321.361.41 1.34 1.38 1.42 1.48 1.39 1.43 1.48 1.53Amps 4.4 4.5 4.7 4.8 4.8 4.9 5.0 5.2 5.2 5.3 5.5 5.7 5.5 5.75.96.1 5.9 6.0 6.2 6.5 6.2 6.4 6.6 6.9Hi PR 210 226 239 249 236 254 268 279 268 288 304 318 305 328347362 343 369 390 407 379 408 431 450Lo PR 106 113 123 131 112 119 130 138 116 124 135 144 122 130142151 128 136 149 158 132 141 154 164650MBh 17.5 17.9 19.1 20.5 17.1 17.5 18.7 20.0 16.7 17.1 18.219.5 16.3 16.7 17.8 19.0 15.5 15.8 16.9 18.1 14.3 14.7 15.7 16.7S/T 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.00 1.00 0.79 0.59 1.00 1.00 0.80 0.60∆ T22.5 21.6 18.8 15.0 22.8 21.9 19.0 15.2 22.8 21.9 19.0 15.2 23.1 22.0 19.2 15.3 21.9 22.4 18.9 15.1 20.3 20.7 17.7 14.1kW1.07 1.09 1.13 1.17 1.16 1.18 1.22 1.27 1.24 1.26 1.31 1.36 1.30 1.34 1.38 1.43 1.36 1.40 1.45 1.50 1.42 1.45 1.50 1.55Amps 4.54.64.7 4.9 4.8 4.9 5.1 5.3 5.2 5.4 5.6 5.8 5.6 5.8 5.9 6.2 6.0 6.1 6.3 6.6 6.3 6.5 6.7 7.0Hi PR 214 230 243 253 240 258 272 284 273 293 310 323 310 334 353 368 349 376 397 414 386 415 439 457Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 16785525MBh 16.5 16.8 17.6 18.7 16.1 16.4 17.2 18.3 15.7 16.0 16.8 17.9 15.3 15.6 16.3 17.4 14.5 14.8 15.5 16.6 13.5 13.7 14.4 15.3S/T 0.92 0.89 0.80 0.65 0.95 0.92 0.83 0.67 0.98 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.75∆ T26.5 26.1 24.6 21.3 26.8 26.4 24.9 21.6 26.9 26.4 25.0 21.6 26.8 26.6 25.1 21.8 25.5 26.0 24.8 21.5 23.6 24.1 23.2 20.0kW1.05 1.07 1.11 1.15 1.14 1.16 1.20 1.24 1.21 1.24 1.28 1.33 1.28 1.31 1.36 1.41 1.34 1.37 1.42 1.47 1.39 1.42 1.47 1.53Amps 4.4 4.5 4.6 4.8 4.7 4.9 5.0 5.2 5.2 5.3 5.5 5.7 5.5 5.6 5.8 6.1 5.9 6.0 6.2 6.4 6.2 6.4 6.6 6.8Hi PR 209 225 238 248 235 253 267 278 267 287 303 317 304 327 346 361 342 368 389 406 378 407 430 448Lo PR 106 112 123 131 112 119 130 138 116 123 135 143 122 130 141 151 128 136 148 158 132 140 153 163600MBh 17.3 17.6 18.5 19.7 16.9 17.2 18.0 19.2 16.5 16.8 17.6 18.8 16.1 16.4 17.2 18.3 15.3 15.6 16.3 17.4 14.2 14.4 15.1 16.1S/T 0.93 0.90 0.81 0.66 0.97 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.93 0.75 1.00 1.00 0.93 0.76∆ T24.8 24.3 23.0 19.9 25.1 24.6 23.3 20.225.1 24.7 23.3 20.2 24.7 24.8 23.5 20.3 23.4 23.9 23.2 20.0 21.7 22.1 21.6 18.7kW1.06 1.08 1.12 1.16 1.15 1.18 1.22 1.26 1.23 1.26 1.30 1.35 1.30 1.33 1.37 1.42 1.36 1.39 1.44 1.49 1.41 1.44 1.49 1.54Amps 4.44.54.7 4.9 4.8 4.9 5.1 5.3 5.2 5.3 5.5 5.7 5.6 5.7 5.9 6.1 5.9 6.1 6.3 6.5 6.3 6.4 6.7 6.9Hi PR 212 228 241 251 238 256 270 282 271 291 308 321 308 332 350 365 347 373 394 411 383 412 435 454Lo PR 107 114 124 132 113 120 131 140 118 125 136 145 123 131 143 153 129 138 150 160 134 142 155 166650MBh 17.8 18.2 19.0 20.3 17.4 17.8 18.6 19.8 17.0 17.3 18.2 19.4 16.6 16.9 17.7 18.9 15.8 16.1 16.8 18.0 14.6 14.9 15.6 16.6S/T 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.98 0.88 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.95 0.77∆ T24.1 23.7 22.4 19.4 24.3 23.9 22.6 19.6 24.1 24.0 22.7 19.6 23.5 23.9 22.8 19.7 22.3 22.7 22.5 19.5 20.6 21.0 21.0 18.2kW1.08 1.10 1.14 1.18 1.17 1.19 1.23 1.28 1.25 1.28 1.32 1.37 1.32 1.35 1.40 1.45 1.38 1.41 1.46 1.51 1.43 1.46 1.51 1.57Amps 4.5 4.6 4.8 4.9 4.9 5.0 5.2 5.4 5.3 5.4 5.6 5.8 5.7 5.8 6.0 6.2 6.0 6.2 6.4 6.6 6.4 6.6 6.8 7.0Hi PR 216 232 245 256 242 261 275 287 275 296 313 326 314 337 356 372 353 380 401 418 390 419 443 462Lo PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects AHRI conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS 6 www.goodmanmfg.com SS-GSX13 eXpAnded CoolinG dAtA — GSX130241d* / CA*f1824*6d*Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 7170700MBh 20.2 20.9 22.9 - 19.7 20.4 22.4 - 19.3 20.0 21.9 - 18.8 19.5 21.3 - 17.8 18.5 20.3 - 16.5 17.1 18.8 -S/T 0.69 0.58 0.40 - 0.72 0.60 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.79 0.66 0.46 -∆ T18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -kW1.60 1.63 1.68 - 1.71 1.75 1.80 - 1.82 1.85 1.91 - 1.91 1.95 2.01 - 1.98 2.02 2.09 - 2.05 2.09 2.16 -Amps 5.7 5.8 6.0 - 6.1 6.3 6.5 - 6.6 6.8 7.0 - 7.1 7.3 7.5 - 7.6 7.8 8.0 - 8.0 8.2 8.5 -Hi PR 226 243 257 - 253 273 288 - 288 310 328 - 328 353 373 - 369 398 420 - 408 439 464 -Lo PR 99 105 115 - 105 111 122 - 109 116 126 - 114 122 133 - 120 127 139 - 124 132 144 -800MBh 21.9 22.7 24.8 - 21.4 22.2 24.3 - 20.9 21.6 23.7 - 20.4 21.1 23.1 - 19.3 20.0 22.0 - 17.9 18.6 20.3 -S/T 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.45 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -∆ T18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -kW1.64 1.67 1.72 - 1.75 1.79 1.85 - 1.86 1.90 1.96 - 1.95 1.99 2.06 - 2.03 2.07 2.14 - 2.10 2.14 2.21 -Amps 5.8 6.0 6.1 - 6.3 6.4 6.7 - 6.8 7.0 7.2 - 7.3 7.5 7.8 - 7.8 8.0 8.3 - 8.3 8.5 8.8 -Hi PR 233 251 265 - 261 281 297 - 297 320 338 - 338 364 385 - 381 410 433 - 421 453 478 -Lo PR 102 109 119 - 108 115 125 - 112 119 130 - 118 125 137 - 124 131 143 - 128 136 148 -900MBh 22.5 23.4 25.6 - 22.0 22.8 25.0 - 21.5 22.3 24.4- 21.0 21.7 23.8 - 19.9 20.6 22.6 - 18.4 19.1 21.0 -S/T 0.75 0.63 0.43 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.82 0.69 0.48 - 0.86 0.71 0.49 - 0.86 0.72 0.50 -∆ T17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 17 15 11 - 16 14 11 -kW1.65 1.68 1.73 - 1.77 1.80 1.86 - 1.87 1.91 1.97 - 1.97 2.01 2.07 - 2.05 2.09 2.16 - 2.12 2.16 2.23 -Amps 5.96.06.2 - 6.3 6.5 6.7 - 6.9 7.1 7.3 - 7.4 7.6 7.8 - 7.9 8.1 8.3 - 8.3 8.6 8.8 -Hi PR 235 253 267 - 264 284 300 - 300 323 341 - 342 368 388 - 385 414 437 - 425 457 483 -Lo PR 103 110 120 - 109 116 127 - 113 121 132 - 119 127 138 - 125 133 145 - 129 137 150 -75700MBh 20.5 21.1 22.9 24.6 20.1 20.7 22.4 24.0 19.6 20.2 21.8 23.4 19.119.721.3 22.9 18.2 18.7 20.2 21.7 16.8 17.3 18.7 20.1S/T 0.79 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.83 0.75 0.56 0.36 0.860.770.58 0.38 0.89 0.80 0.61 0.39 0.90 0.81 0.61 0.39∆ T21 20 16 11 21 20 16 11 21 20 16 11 222016 11 21 20 16 11 20 18 15 10kW1.61 1.64 1.69 1.74 1.73 1.76 1.82 1.87 1.83 1.87 1.93 1.99 1.921.962.02 2.09 2.00 2.04 2.11 2.17 2.07 2.11 2.18 2.25Amps 5.7 5.8 6.0 6.3 6.2 6.3 6.5 6.8 6.7 6.9 7.1 7.4 7.27.47.6 7.9 7.6 7.8 8.1 8.4 8.1 8.3 8.6 8.9Hi PR 228 246 259 270 256 276 291 303 291 313 331 345 332357377 393 373 402 424 442 412 444 469 489Lo PR 100 107 116 124 106 113 123 131 110 117 128 136 116123134 143 121 129 141 150 125 133 145 155800MBh 22.3 22.9 24.8 26.6 21.7 22.4 24.2 26.0 21.2 21.8 23.6 25.4 20.721.323.1 24.8 19.7 20.2 21.9 23.5 18.2 18.8 20.3 21.8S/T 0.81 0.73 0.55 0.35 0.84 0.76 0.57 0.37 0.87 0.77 0.59 0.38 0.890.800.60 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41∆ T21 19 16 11 21 19 16 1121 19 16 11 212016 11 21 19 16 11 20 18 15 10kW1.65 1.68 1.73 1.78 1.77 1.80 1.86 1.92 1.87 1.91 1.97 2.04 1.972.012.07 2.14 2.05 2.09 2.16 2.23 2.12 2.16 2.23 2.30Amps 5.96.06.2 6.4 6.3 6.5 6.7 7.0 6.9 7.1 7.3 7.6 7.47.67.8 8.1 7.9 8.1 8.3 8.7 8.3 8.6 8.8 9.2Hi PR 235 253 267 279 264 284 300 313 300 323 341 356 342368389 405 385 414 437 456 425 457 483 504Lo PR 103 110 120 128 109 116 127 135 113 121 132 140 119127138 147 125 133 145 154 129 137 150 160900MBh 22.9 23.6 25.5 27.4 22.4 23.0 24.9 26.8 21.9 22.5 24.4 26.1 21.322.023.8 25.5 20.3 20.9 22.6 24.2 18.8 19.3 20.9 22.4S/T 0.85 0.76 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.61 0.40 0.940.840.63 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.66 0.43∆ T20 18 15 10 20 19 15 11 20 19 15 11 201915 11 20 19 15 10 19 17 14 10kW1.66 1.69 1.75 1.80 1.78 1.82 1.87 1.93 1.89 1.93 1.99 2.05 1.982.032.09 2.16 2.06 2.11 2.18 2.25 2.13 2.18 2.25 2.32Amps 5.9 6.1 6.3 6.5 6.4 6.6 6.8 7.0 7.0 7.1 7.4 7.7 7.57.67.9 8.2 7.9 8.1 8.4 8.7 8.4 8.6 8.9 9.3Hi PR 238 256 270 282 267 287 303 316 303 326 345 359 345372392 409 389 418 442 461 429 462 488 509Lo PR 104 111 121 129 110 117 128 136 114 122 133 142 120128140 149 126 134 146 156 130 139 151 161IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects ACCA (TVA) conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS SS-GSX13 www.goodmanmfg.com 7 eXpAnded CoolinG dAtA — GSX130241d* / CA*f1824*6d* (Cont.)Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 7180700MBh 20.9 21.4 22.8 24.4 20.4 20.9 22.3 23.8 19.9 20.4 21.8 23.3 19.4 19.9 21.2 22.7 18.5 18.9 20.2 21.6 17.1 17.5 18.7 20.0S/T 0.86 0.81 0.66 0.49 0.89 0.84 0.68 0.51 0.92 0.86 0.70 0.52 0.94 0.89 0.72 0.54 0.98 0.92 0.75 0.56 0.99 0.93 0.75 0.56∆ T24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 19 15kW1.62 1.66 1.71 1.76 1.74 1.78 1.83 1.89 1.85 1.88 1.94 2.00 1.94 1.98 2.04 2.10 2.01 2.06 2.12 2.19 2.08 2.13 2.19 2.27Amps 5.8 5.9 6.1 6.3 6.2 6.4 6.6 6.8 6.8 6.9 7.2 7.4 7.2 7.4 7.7 8.0 7.7 7.9 8.2 8.5 8.2 8.4 8.7 9.0Hi PR 231 248 262 273 259 278 294 307 294 317 334 349 335 361 381 397 377 406 428 447 416 448 473 494Lo PR 101 108 117 125 107 114 124 132 111 118 129 137 117 124 136 144 122 130 142 151 126 135 147 156800MBh 22.6 23.1 24.7 26.4 22.1 22.6 24.2 25.8 21.6 22.1 23.6 25.2 21.1 21.523.024.6 20.0 20.5 21.9 23.4 18.5 18.9 20.2 21.6S/T 0.89 0.84 0.68 0.51 0.93 0.87 0.71 0.53 0.95 0.89 0.72 0.54 0.98 0.920.750.56 1.00 0.95 0.78 0.58 1.00 0.96 0.78 0.59∆ T23 22 19 15 24 23 20 16 24 23 20 16 24 232016 23 22 19 16 21 21 18 15kW1.66 1.69 1.75 1.80 1.78 1.82 1.87 1.93 1.89 1.93 1.99 2.05 1.98 2.032.092.16 2.06 2.11 2.18 2.25 2.13 2.18 2.25 2.32Amps 5.9 6.1 6.3 6.5 6.4 6.6 6.8 7.0 7.0 7.1 7.4 7.7 7.5 7.67.98.2 7.9 8.1 8.4 8.7 8.4 8.6 8.9 9.3Hi PR 238 256 270 282 267 287 303 316 303 326 345 359 345 372393409 389 418 442 461 429 462 488 509Lo PR 104 111 121 129 110 117 128 136 115 122 133 142 120 128140149 126 134 146 156 130 139 151 161900MBh 23.3 23.8 25.5 27.2 22.8 23.3 24.9 26.6 22.2 22.7 24.326.0 21.7 22.2 23.7 25.3 20.6 21.1 22.5 24.1 19.1 19.5 20.8 22.3S/T 0.94 0.88 0.71 0.53 0.97 0.91 0.74 0.55 1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.59 1.00 1.00 0.81 0.61 1.00 1.00 0.82 0.61∆ T22 21 19 15 23 22 19 15 23 22 19 15 22 22 19 15 21 22 19 15 20 20 17 14kW1.67 1.71 1.76 1.81 1.80 1.83 1.89 1.95 1.90 1.94 2.00 2.07 2.00 2.04 2.11 2.17 2.08 2.13 2.19 2.26 2.15 2.20 2.27 2.34Amps 6.06.16.3 6.6 6.5 6.6 6.8 7.1 7.0 7.2 7.5 7.7 7.5 7.7 8.0 8.3 8.0 8.2 8.5 8.8 8.5 8.7 9.0 9.4Hi PR 240 258 273 284 269 290 306 319 306 330 348 363 349 375 396 413 392 422 446 465 434 467 493 514Lo PR 105 112 122 130 111 118 129 138 116 123 134 143 121 129 141 150 127 135 148 157 132 140 153 16385700MBh 21.3 21.7 22.7 24.2 20.8 21.2 22.2 23.7 20.3 20.7 21.7 23.1 19.8 20.2 21.1 22.5 18.8 19.2 20.1 21.4 17.4 17.7 18.6 19.8S/T 0.90 0.87 0.79 0.64 0.94 0.90 0.81 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.90 0.73∆ T25 25 23 20 26 25 24 21 26 25 24 21 26 25 24 21 25 25 24 20 23 23 22 19kW1.64 1.67 1.72 1.77 1.75 1.79 1.84 1.90 1.86 1.90 1.96 2.02 1.95 1.99 2.06 2.12 2.03 2.07 2.14 2.21 2.10 2.14 2.21 2.28Amps 5.8 5.9 6.1 6.4 6.3 6.4 6.7 6.9 6.8 7.0 7.2 7.5 7.3 7.5 7.7 8.0 7.8 8.0 8.3 8.6 8.3 8.5 8.8 9.1Hi PR 233 251 265 276 261 281 297 310 297 320 338 352 338 364 385 401 381 410 433 451 421 453 478 499Lo PR 102 109 119 126 108 115 125 134 112 119 130 139 118 125 137 146 123 131 143 153 128 136 148 158800MBh 23.0 23.5 24.6 26.2 22.5 22.9 24.0 25.6 22.0 22.4 23.5 25.0 21.4 21.9 22.9 24.4 20.4 20.8 21.7 23.2 18.9 19.2 20.1 21.5S/T 0.94 0.90 0.82 0.66 0.97 0.94 0.85 0.69 1.00 0.96 0.87 0.70 1.00 0.99 0.89 0.73 1.00 1.00 0.93 0.75 1.00 1.00 0.94 0.76∆ T25 24 23 20 25 25 23 2025 25 23 20 25 25 24 20 23 24 23 20 22 22 22 19kW1.67 1.71 1.76 1.81 1.80 1.83 1.89 1.95 1.90 1.94 2.00 2.07 2.00 2.04 2.11 2.17 2.08 2.13 2.19 2.26 2.15 2.20 2.27 2.34Amps 6.06.16.3 6.6 6.5 6.6 6.8 7.1 7.0 7.2 7.5 7.7 7.5 7.7 8.0 8.3 8.0 8.2 8.5 8.8 8.5 8.7 9.0 9.4Hi PR 240 258 273 284 269 290 306 319 306 330 348 363 349 375 396 413 392 422 446 465 434 467 493 514Lo PR 105 112 122 130 111 118 129 138 116 123 134 143 121 129 141 150 127 135 148 157 132 140 153 163900MBh 23.7 24.2 25.3 27.0 23.2 23.6 24.8 26.4 22.6 23.1 24.2 25.8 22.1 22.5 23.6 25.1 21.0 21.4 22.4 23.9 19.4 19.8 20.7 22.1S/T 0.98 0.95 0.86 0.69 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.97 0.79 1.00 1.00 0.98 0.80∆ T24 23 22 19 24 24 22 19 23 24 22 19 23 23 23 20 21 22 22 19 20 20 21 18kW1.69 1.72 1.77 1.83 1.81 1.85 1.90 1.96 1.92 1.96 2.02 2.09 2.02 2.06 2.12 2.19 2.10 2.14 2.21 2.28 2.17 2.22 2.29 2.36Amps 6.0 6.2 6.4 6.6 6.5 6.7 6.9 7.2 7.1 7.3 7.5 7.8 7.6 7.8 8.0 8.4 8.1 8.3 8.6 8.9 8.6 8.8 9.1 9.5Hi PR 242 261 275 287 272 293 309 322 309 333 352 367 352 379 400 418 396 427 450 470 438 471 498 519Lo PR 106 113 124 132 112 120 131 139 117 124 136 144 123 131 143 152 129 137 149 159 133 142 154 165IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects AHRI conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS 8 www.goodmanmfg.com SS-GSX13 eXpAnded CoolinG dAtA — GSX130301B* / CA*f3030*6d*Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 7170945MBh 26.2 27.2 29.8 - 25.6 26.6 29.1 - 25.0 25.9 28.4 - 24.4 25.3 27.7 - 23.2 24.0 26.3 - 21.5 22.3 24.4 -S/T 0.71 0.59 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.82 0.68 0.47 -∆ T18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -kW2.01 2.05 2.11 - 2.15 2.20 2.26 - 2.28 2.33 2.40 - 2.39 2.44 2.51 - 2.48 2.54 2.62 - 2.57 2.62 2.70 -Amps 6.9 7.1 7.3 - 7.5 7.7 8.0 - 8.2 8.4 8.7 - 8.7 9.0 9.3 - 9.3 9.5 9.9 - 9.9 10.1 10.5 -Hi PR 244 262 277 - 274 294 311 - 311 335 354 - 354 381 403 - 399 429 453 - 440 474 501 -Lo PR 104 110 120 - 109 116 127 - 114 121 132 - 119 127 139 - 125 133 145 - 129 138 150 -1050MBh 26.6 27.6 30.3 - 26.0 27.0 29.5 - 25.4 26.3 28.8 - 24.8 25.7 28.1 - 23.5 24.4 26.7 - 21.8 22.6 24.8 -S/T 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -∆ T17 15 11 - 17 15 11 - 17 15 11 - 18 15 12 - 17 15 11 - 16 14 11 -kW2.04 2.08 2.14 - 2.18 2.23 2.29 - 2.31 2.36 2.43 - 2.42 2.47 2.55 - 2.52 2.57 2.65 - 2.60 2.66 2.74 -Amps 7.0 7.2 7.5 - 7.6 7.8 8.1 - 8.3 8.5 8.8 - 8.9 9.1 9.4 - 9.5 9.7 10.0 - 10.0 10.3 10.6 -Hi PR 248 267 282 - 278 299 316 - 317 341 360 - 360 388 410 - 406 436 461 - 448 482 509 -Lo PR 105 112 122 - 111 118 129 - 116 123 134 - 122 129 141 - 127 135 148 - 132 140 153 -1155MBh 27.0 28.0 30.7 - 26.4 27.4 30.0 - 25.8 26.7 29.3- 25.2 26.1 28.6 - 23.9 24.8 27.1 - 22.1 22.9 25.1 -S/T 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.88 0.73 0.51 - 0.88 0.74 0.51 -∆ T17 14 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 14 11 - 16 13 10 -kW2.05 2.09 2.15 - 2.19 2.24 2.30 - 2.32 2.37 2.44 - 2.44 2.49 2.56 - 2.53 2.59 2.67 - 2.62 2.67 2.76 -Amps 7.17.37.5 - 7.7 7.9 8.1 - 8.4 8.6 8.9 - 8.9 9.2 9.5 - 9.5 9.8 10.1 - 10.1 10.4 10.7 -Hi PR 250 269 284 - 280 302 318 - 319 343 362 - 363 391 413 - 408 439 464 - 451 486 513 -Lo PR 106 113 123 - 112 119 130 - 116 124 135 - 122 130 142 - 128 136 149 - 133 141 154 -75945MBh 26.7 27.5 29.7 31.9 26.1 26.8 29.0 31.2 25.4 26.2 28.4 30.4 24.825.627.7 29.7 23.6 24.3 26.3 28.2 21.8 22.5 24.3 26.1S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.890.790.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40∆ T21 19 16 11 21 20 16 11 21 20 16 11 212016 11 21 19 16 11 20 18 15 10kW2.03 2.07 2.13 2.19 2.17 2.21 2.28 2.35 2.30 2.34 2.42 2.49 2.412.462.53 2.61 2.50 2.56 2.64 2.72 2.59 2.64 2.72 2.81Amps 7.0 7.2 7.4 7.7 7.6 7.8 8.0 8.3 8.2 8.5 8.7 9.1 8.89.09.3 9.7 9.4 9.6 10.0 10.3 10.0 10.2 10.6 11.0Hi PR 246 265 280 292 276 297 314 328 314 338 357 373 358385407 424 403 433 458 477 445 479 506 527Lo PR 105 111 121 129 111 118 128 137 115 122 133 142 121128140 149 126 135 147 156 131 139 152 1621050MBh 27.1 27.9 30.2 32.4 26.5 27.2 29.5 31.6 25.8 26.6 28.8 30.9 25.225.928.1 30.1 23.9 24.6 26.7 28.6 22.2 22.8 24.7 26.5S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.60 0.39 0.920.820.62 0.40 0.95 0.85 0.65 0.42 0.96 0.86 0.65 0.42∆ T20 18 15 10 20 19 15 1020 19 15 10 201915 11 20 18 15 10 19 17 14 10kW2.05 2.09 2.15 2.22 2.20 2.24 2.31 2.38 2.33 2.38 2.45 2.52 2.442.492.57 2.65 2.54 2.59 2.67 2.76 2.62 2.68 2.76 2.85Amps 7.17.37.5 7.8 7.7 7.9 8.2 8.5 8.4 8.6 8.9 9.2 9.09.29.5 9.9 9.6 9.8 10.1 10.5 10.1 10.4 10.7 11.2Hi PR 251 270 285 297 281 303 319 333 320 344 363 379 364392414 432 410 441 466 486 453 487 514 536Lo PR 106 113 124 132 112 120 131 139 117 124 136 145 123131143 152 129 137 149 159 133 142 155 1651155MBh 27.5 28.3 30.6 32.9 26.9 27.7 29.9 32.1 26.2 27.0 29.2 31.4 25.626.328.5 30.6 24.3 25.0 27.1 29.1 22.5 23.2 25.1 26.9S/T 0.88 0.78 0.59 0.38 0.91 0.81 0.61 0.40 0.93 0.83 0.63 0.41 0.960.860.65 0.42 1.00 0.89 0.67 0.43 1.00 0.90 0.68 0.44∆ T19 18 14 10 19 18 15 10 19 18 15 10 201815 10 19 18 15 10 18 17 14 9kW2.06 2.10 2.16 2.23 2.21 2.25 2.32 2.39 2.34 2.39 2.46 2.54 2.452.512.58 2.67 2.55 2.61 2.69 2.77 2.64 2.69 2.78 2.87Amps 7.2 7.3 7.6 7.9 7.8 7.9 8.2 8.5 8.4 8.6 8.9 9.3 9.09.29.6 9.9 9.6 9.9 10.2 10.6 10.2 10.5 10.8 11.2Hi PR 252 272 287 299 283 305 322 336 322 346 366 382 367395417 435 413 444 469 489 456 491 518 540Lo PR 107 114 124 133 113 120 131 140 118 125 137 146 124131144 153 130 138 150 160 134 143 156 166IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects ACCA (TVA) conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS SS-GSX13 www.goodmanmfg.com 9 eXpAnded CoolinG dAtA — GSX130301B* / CA*f3030*6d* (Cont.)Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 7180945MBh 27.2 27.8 29.6 31.7 26.5 27.1 29.0 31.0 25.9 26.5 28.3 30.2 25.3 25.8 27.6 29.5 24.0 24.5 26.2 28.0 22.2 22.7 24.3 25.9S/T 0.89 0.83 0.68 0.51 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.56 1.01 0.95 0.77 0.58 1.00 0.95 0.78 0.58∆ T23 22 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 18 15kW2.04 2.08 2.14 2.21 2.19 2.23 2.30 2.37 2.31 2.36 2.43 2.51 2.43 2.48 2.56 2.64 2.52 2.58 2.66 2.74 2.61 2.66 2.75 2.83Amps 7.1 7.2 7.5 7.8 7.7 7.8 8.1 8.4 8.3 8.5 8.8 9.2 8.9 9.1 9.4 9.8 9.5 9.7 10.1 10.4 10.1 10.3 10.7 11.1Hi PR 249 268 283 295 279 300 317 331 317 342 361 376 362 389 411 429 407 438 462 482 449 484 511 533Lo PR 106 112 123 131 112 119 130 138 116 123 135 144 122 130 142 151 128 136 148 158 132 141 153 1631050MBh 27.6 28.2 30.1 32.2 26.9 27.5 29.4 31.4 26.3 26.9 28.7 30.7 25.6 26.228.029.9 24.4 24.9 26.6 28.4 22.6 23.1 24.6 26.3S/T 0.92 0.86 0.70 0.52 0.95 0.89 0.73 0.54 0.98 0.92 0.75 0.56 1.00 0.950.770.58 1.00 0.98 0.80 0.60 1.00 0.99 0.81 0.60∆ T22 21 18 15 22 22 19 15 22 22 19 15 22 221915 21 21 19 15 20 20 17 14kW2.07 2.11 2.17 2.23 2.21 2.26 2.33 2.40 2.35 2.39 2.47 2.54 2.46 2.512.592.67 2.56 2.61 2.69 2.78 2.64 2.70 2.78 2.87Amps 7.2 7.4 7.6 7.9 7.8 8.0 8.2 8.5 8.5 8.7 9.0 9.3 9.1 9.39.610.0 9.6 9.9 10.2 10.6 10.2 10.5 10.8 11.3Hi PR 253 272 288 300 284 306 323 337 323 348 367 383 368 396418436 414 445 470 490 457 492 520 542Lo PR 107 114 125 133 114 121 132 140 118 126 137 146 124 132144153 130 138 151 161 134 143 156 1661155MBh 28.0 28.6 30.6 32.7 27.3 27.9 29.8 31.9 26.7 27.3 29.131.1 26.0 26.6 28.4 30.4 24.7 25.3 27.0 28.9 22.9 23.4 25.0 26.7S/T 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.84 0.63∆ T21 21 18 14 22 21 18 14 21 21 18 14 21 21 18 15 20 20 18 14 18 19 17 13kW2.08 2.12 2.18 2.25 2.23 2.27 2.34 2.41 2.36 2.41 2.48 2.56 2.47 2.53 2.60 2.69 2.57 2.63 2.71 2.80 2.66 2.71 2.80 2.89Amps 7.27.47.7 7.9 7.8 8.0 8.3 8.6 8.5 8.7 9.0 9.4 9.1 9.3 9.7 10.0 9.7 9.9 10.3 10.7 10.3 10.6 10.9 11.3Hi PR 255 274 290 302 286 308 325 339 325 350 370 385 370 399 421 439 417 448 474 494 460 495 523 546Lo PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 16785945MBh 27.6 28.2 29.5 31.5 27.0 27.5 28.8 30.7 26.3 26.9 28.1 30.0 25.7 26.2 27.4 29.3 24.4 24.9 26.1 27.8 22.6 23.1 24.1 25.8S/T 0.93 0.90 0.81 0.66 0.96 0.93 0.84 0.68 0.99 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.93 0.75∆ T25 25 23 20 25 25 24 20 25 25 24 20 25 25 24 21 24 24 23 20 22 22 22 19kW2.06 2.10 2.16 2.22 2.20 2.25 2.31 2.39 2.33 2.38 2.45 2.53 2.45 2.50 2.58 2.66 2.54 2.60 2.68 2.76 2.63 2.68 2.77 2.86Amps 7.1 7.3 7.6 7.8 7.7 7.9 8.2 8.5 8.4 8.6 8.9 9.2 9.0 9.2 9.5 9.9 9.6 9.8 10.2 10.5 10.2 10.4 10.8 11.2Hi PR 251 270 286 298 282 303 320 334 321 345 364 380 365 393 415 433 411 442 467 487 454 489 516 538Lo PR 107 114 124 132 113 120 131 139 117 125 136 145 123 131 143 152 129 137 150 160 133 142 155 1651050MBh 28.1 28.6 29.9 32.0 27.4 27.9 29.3 31.2 26.7 27.3 28.6 30.5 26.1 26.6 27.9 29.7 24.8 25.3 26.5 28.2 23.0 23.4 24.5 26.2S/T 0.96 0.93 0.84 0.68 1.00 0.96 0.87 0.71 1.00 0.99 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.96 0.78∆ T24 23 22 19 24 24 22 1923 24 22 19 23 23 22 19 22 22 22 19 20 20 21 18kW2.08 2.12 2.19 2.25 2.23 2.28 2.35 2.42 2.36 2.41 2.49 2.56 2.48 2.53 2.61 2.69 2.58 2.63 2.72 2.80 2.66 2.72 2.81 2.90Amps 7.27.47.7 8.0 7.8 8.0 8.3 8.6 8.5 8.7 9.0 9.4 9.1 9.4 9.7 10.1 9.7 10.0 10.3 10.7 10.3 10.6 10.9 11.4Hi PR 256 275 290 303 287 309 326 340 326 351 371 387 372 400 422 440 418 450 475 495 462 497 525 547Lo PR 109 116 126 134 115 122 133 142 119 127 138 147 125 133 145 155 131 140 152 162 136 144 158 1681155MBh 28.5 29.0 30.4 32.4 27.8 28.4 29.7 31.7 27.1 27.7 29.0 30.9 26.5 27.0 28.3 30.2 25.2 25.7 26.9 28.7 23.3 23.8 24.9 26.5S/T 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.93 0.76 1.00 1.00 0.96 0.78 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.82∆ T23 22 21 18 22 23 21 19 22 22 21 19 21 21 22 19 20 20 21 18 19 19 20 17kW2.09 2.13 2.20 2.26 2.24 2.29 2.36 2.43 2.38 2.43 2.50 2.58 2.49 2.55 2.62 2.71 2.59 2.65 2.73 2.82 2.68 2.74 2.82 2.91Amps 7.3 7.5 7.7 8.0 7.9 8.1 8.4 8.7 8.6 8.8 9.1 9.5 9.2 9.4 9.7 10.1 9.8 10.0 10.4 10.8 10.4 10.7 11.0 11.4Hi PR 257 277 292 305 289 311 328 342 328 353 373 389 374 403 425 443 421 453 478 499 465 500 528 551Lo PR 109 116 127 135 116 123 134 143 120 128 139 148 126 134 146 156 132 141 153 163 137 145 159 169IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects AHRI conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS 10 www.goodmanmfg.com SS-GSX13Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71701350MBh 32.8 34.0 37.2 - 32.0 33.2 36.4 - 31.3 32.4 35.5 - 30.5 31.6 34.6 - 29.0 30.0 32.9 - 26.8 27.8 30.5 -S/T 0.80 0.67 0.47 - 0.83 0.70 0.48 - 0.85 0.71 0.49 - 0.88 0.74 0.51 - 0.92 0.76 0.53 - 0.92 0.77 0.53 -∆ T18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -kW1.92 1.97 2.06 - 2.12 2.19 2.28 - 2.31 2.37 2.48 - 2.47 2.54 2.65 - 2.61 2.68 2.80 - 2.72 2.80 2.92 -Amps 10.4 10.6 11.0 - 11.2 11.5 11.9 - 12.2 12.5 12.9 - 13.0 13.4 13.8 - 13.9 14.2 14.7 - 14.7 15.1 15.6 -Hi PR 200 215 227 - 224 241 255 - 255 275 290 - 291 313 330 - 327 352 371 - 361 389 410 -Lo PR 97 104 113 - 103 109 119 - 107 114 124 - 112 119 130 - 118 125 137 - 122 130 141 -986MBh 31.7 32.8 36.0 - 30.9 32.1 35.1 - 30.2 31.3 34.3 - 29.5 30.5 33.5 - 28.0 29.0 31.8 - 25.9 26.9 29.4 -S/T 0.76 0.63 0.44 - 0.78 0.66 0.45 - 0.80 0.67 0.47 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.87 0.73 0.50 -∆ T22 19 15 - 23 20 15 - 23 20 15 - 23 20 15 - 22 19 15 - 21 18 14 -kW1.88 1.93 2.02 - 2.08 2.14 2.23 - 2.26 2.32 2.42 - 2.42 2.49 2.59 - 2.55 2.62 2.74 - 2.67 2.74 2.86 -Amps 10.2 10.5 10.8 - 11.0 11.3 11.7 - 12.0 12.3 12.7 - 12.8 13.1 13.5 - 13.6 14.0 14.4 - 14.4 14.8 15.3 -Hi PR 196 211 223 - 220 237 250 - 250 269 284 - 285 307 324 - 320 345 364 - 354 381 402 -Lo PR 95 102 111 - 101 107 117 - 105 112 122 - 110 117 128 - 115 123 134 - 119 127 139 -1050MBh 32.0 33.2 36.3 - 31.2 32.4 35.5 - 30.5 31.6 34.6- 29.8 30.8 33.8 - 28.3 29.3 32.1 - 26.2 27.1 29.7 -S/T 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.88 0.73 0.51 - 0.89 0.74 0.51 -∆ T22 19 14 - 22 19 14 - 22 19 14 - 22 19 14 - 22 19 14 - 20 18 13 -kW1.88 1.94 2.02 - 2.08 2.15 2.24 - 2.26 2.33 2.43 - 2.42 2.49 2.60 - 2.56 2.63 2.74 - 2.67 2.75 2.87 -Amps 10.210.510.8 - 11.1 11.3 11.7 - 12.0 12.3 12.7 - 12.8 13.1 13.6 - 13.7 14.0 14.5 - 14.5 14.8 15.3 -Hi PR 197 212 223 - 221 237 251 - 251 270 285 - 286 307 325 - 321 346 365 - 355 382 404 -Lo PR 96 102 111 - 101 108 117 - 105 112 122 - 110 117 128 - 116 123 134 - 120 127 139 -751350MBh 33.34 34.32 37.15 39.87 32.56 33.52 36.29 38.94 31.78 32.73 35.42 38.02 31.0131.9334.56 37.09 29.46 30.33 32.83 35.24 27.29 28.10 30.41 32.64S/T 0.91 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.97 0.87 0.66 0.42 1.000.900.68 0.44 1.00 0.93 0.70 0.45 1.00 0.94 0.71 0.46∆ T21 19 16 11 21 19 16 11 21 19 16 11 212016 11 20 19 16 11 19 18 15 10kW1.94 2.00 2.08 2.18 2.15 2.21 2.31 2.41 2.33 2.40 2.50 2.61 2.502.572.68 2.79 2.63 2.71 2.83 2.95 2.75 2.83 2.95 3.08Amps 10.5 10.7 11.1 11.5 11.3 11.6 12.0 12.4 12.3 12.6 13.0 13.5 13.213.513.9 14.5 14.0 14.3 14.8 15.4 14.8 15.2 15.7 16.3Hi PR 202 217 229 239 227 244 257 269 258 277 293 305 294316334 348 330 355 375 391 365 393 415 432Lo PR 98 105 114 122 104 111 121 129 108 115 125 134 113121132 140 119 127 138 147 123 131 143 152986MBh 32.2 33.2 35.9 38.5 31.5 32.4 35.1 37.6 30.7 31.6 34.2 36.7 30.030.833.4 35.8 28.5 29.3 31.7 34.0 26.4 27.1 29.4 31.5S/T 0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.91 0.82 0.62 0.40 0.940.840.64 0.41 0.98 0.88 0.66 0.43 0.99 0.88 0.67 0.43∆ T26 24 19 13 26 24 20 1426 24 20 14 262420 14 26 24 20 14 24 22 18 13kW1.90 1.95 2.04 2.13 2.10 2.16 2.26 2.36 2.28 2.35 2.45 2.56 2.442.512.62 2.73 2.58 2.65 2.77 2.89 2.70 2.77 2.89 3.02Amps 10.310.610.9 11.3 11.1 11.4 11.8 12.2 12.1 12.4 12.8 13.3 12.913.213.7 14.2 13.7 14.1 14.6 15.1 14.6 14.9 15.4 16.0Hi PR 198 213 225 235 222 239 252 263 253 272 287 299 288310327 341 324 348 368 384 358 385 406 424Lo PR 96 103 112 119 102 108 118 126 106 113 123 131 111118129 138 117 124 135 144 121 128 140 1491050MBh 32.5 33.5 36.3 38.9 31.8 32.7 35.4 38.0 31.0 31.9 34.6 37.1 30.331.1633.7 36.2 28.7 29.6 32.0 34.4 26.6 27.4 29.7 31.9S/T 0.88 0.78 0.59 0.38 0.91 0.81 0.62 0.40 0.93 0.83 0.63 0.41 0.960.860.65 0.42 1.00 0.89 0.68 0.43 1.00 0.90 0.68 0.44∆ T25 23 19 13 25 23 19 13 25 23 19 13 252319 13 25 23 19 13 23 22 18 12kW1.90 1.96 2.05 2.14 2.11 2.17 2.27 2.36 2.29 2.36 2.46 2.57 2.452.522.63 2.74 2.59 2.66 2.78 2.89 2.70 2.78 2.90 3.03Amps 10.3 10.6 10.9 11.3 11.2 11.4 11.8 12.2 12.1 12.4 12.8 13.3 13.013.313.7 14.2 13.8 14.1 14.6 15.1 14.6 15.0 15.5 16.1Hi PR 199 214 226 235 223 240 253 264 253 273 288 300 289311328 342 325 349 369 385 359 386 408 425Lo PR 97 103 112 120 102 109 119 126 106 113 123 131 112119130 138 117 124 136 145 121 129 140 150IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects ACCA (TVA) conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system powereXpAnded CoolinG dAtA — GSX130361C* / CA*f3642*6C* Product SPecificationS SS-GSX13 www.goodmanmfg.com 11Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71801350MBh 33.93 34.67 37.04 39.59 33.14 33.86 36.18 38.67 32.35 33.06 35.32 37.75 31.56 32.25 34.46 36.83 29.98 30.64 32.73 34.99 27.77 28.38 30.32 32.41S/T 1.00 0.94 0.77 0.57 1.00 1.00 0.79 0.59 1.00 1.00 0.81 0.61 1.00 1.00 0.84 0.63 1.00 1.00 0.87 0.65 1.00 1.00 0.88 0.66∆ T23 22 19 15 23 23 20 16 22 23 20 16 21 22 20 16 20 21 19 16 19 19 18 14kW1.96 2.02 2.11 2.20 2.17 2.24 2.33 2.43 2.36 2.43 2.53 2.64 2.52 2.60 2.71 2.82 2.66 2.74 2.86 2.98 2.78 2.86 2.99 3.11Amps 10.6 10.8 11.2 11.6 11.4 11.7 12.1 12.5 12.4 12.7 13.1 13.6 13.3 13.6 14.1 14.6 14.1 14.5 15.0 15.5 15.0 15.3 15.9 16.5Hi PR 204 220 232 242 229 246 260 271 260 280 296 309 296 319 337 351 334 359 379 395 369 397 419 437Lo PR 99 106 115 123 105 112 122 130 109 116 127 135 115 122 133 142 120 128 139 149 124 132 144 154986MBh 32.8 33.5 35.8 38.3 32.0 32.7 35.0 37.4 31.3 31.9 34.1 36.5 30.5 31.233.335.6 29.0 29.6 31.6 33.8 26.8 27.4 29.3 31.3S/T 0.94 0.88 0.72 0.54 0.98 0.92 0.75 0.56 1.00 0.94 0.77 0.57 1.00 0.970.790.59 1.00 1.00 0.82 0.61 1.00 1.00 0.83 0.62∆ T29 28 24 19 29 28 24 19 29 28 24 19 28 282520 27 28 24 19 25 26 23 18kW1.92 1.97 2.06 2.15 2.12 2.19 2.28 2.38 2.31 2.38 2.48 2.59 2.47 2.542.652.76 2.61 2.68 2.80 2.92 2.72 2.80 2.92 3.05Amps 10.4 10.6 11.0 11.4 11.2 11.5 11.9 12.3 12.2 12.5 12.9 13.4 13.0 13.413.814.3 13.9 14.2 14.7 15.2 14.7 15.1 15.6 16.2Hi PR 200 215 227 237 224 241 255 266 255 275 290 302 291 313330345 327 352 372 388 361 389 411 428Lo PR 97 104 113 120 103 109 120 127 107 114 124 132 112 120131139 118 125 137 146 122 130 141 1511050MBh 33.1 33.8 36.1 38.6 32.3 33.0 35.3 37.7 31.6 32.3 34.536.8 30.8 31.5 33.6 35.9 29.3 29.9 31.9 34.1 27.1 27.7 29.6 31.6S/T 0.96 0.90 0.73 0.55 1.00 0.94 0.76 0.57 1.00 0.96 0.78 0.58 1.00 0.99 0.81 0.60 1.00 1.00 0.84 0.62 1.00 1.00 0.84 0.63∆ T28 27 23 19 28 27 24 19 28 27 24 19 27 27 24 19 26 26 23 19 24 24 22 17kW1.92 1.98 2.07 2.16 2.13 2.19 2.29 2.39 2.32 2.38 2.49 2.59 2.48 2.55 2.66 2.77 2.61 2.69 2.81 2.93 2.73 2.81 2.93 3.06Amps 10.410.711.0 11.4 11.3 11.5 11.9 12.4 12.2 12.5 12.9 13.4 13.1 13.4 13.8 14.4 13.9 14.3 14.7 15.3 14.7 15.1 15.6 16.2Hi PR 201 216 228 238 225 242 256 267 256 275 291 303 292 314 331 346 328 353 373 389 362 390 412 430Lo PR 98 104 113 121 103 110 120 128 107 114 125 133 113 120 131 139 118 126 137 146 122 130 142 151851350MBh 34.52 35.19 36.85 39.32 33.72 34.37 36.00 38.40 32.92 33.55 35.14 37.49 32.11 32.73 34.28 36.57 30.51 31.10 32.57 34.75 28.26 28.81 30.17 32.19S/T 1.00 1.00 0.92 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.97 0.79 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.85 1.00 1.00 1.00 0.85∆ T24 24 23 20 23 23 23 20 22 23 23 20 22 22 23 20 21 21 22 20 19 20 21 19kW1.98 2.04 2.13 2.22 2.20 2.26 2.36 2.46 2.38 2.45 2.56 2.67 2.55 2.62 2.74 2.85 2.69 2.77 2.89 3.01 2.81 2.89 3.02 3.15Amps 10.7 10.9 11.3 11.7 11.5 11.8 12.2 12.7 12.5 12.8 13.3 13.8 13.4 13.7 14.2 14.7 14.3 14.6 15.1 15.7 15.1 15.5 16.0 16.6Hi PR 206 222 234 244 231 249 263 274 263 283 299 312 299 322 340 355 337 363 383 399 372 401 423 441Lo PR 100 107 117 124 106 113 123 131 110 117 128 136 116 123 134 143 121 129 141 150 125 133 146 155986MBh 33.4 34.0 35.6 38.0 32.6 33.2 34.8 37.1 31.8 32.4 34.0 36.2 31.0 31.6 33.1 35.3 29.5 30.0 31.5 33.6 27.3 27.8 29.1 31.1S/T 0.99 0.95 0.86 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.92 0.74 1.00 1.00 0.94 0.77 1.00 1.00 0.98 0.80 1.00 1.00 0.99 0.80∆ T31 30 29 25 30 31 29 2530 30 29 25 29 29 29 25 27 28 29 25 25 26 27 23kW1.94 2.00 2.08 2.18 2.15 2.21 2.31 2.41 2.33 2.40 2.50 2.61 2.50 2.57 2.68 2.79 2.63 2.71 2.83 2.95 2.75 2.83 2.95 3.08Amps 10.510.711.1 11.5 11.3 11.6 12.0 12.4 12.3 12.6 13.0 13.5 13.2 13.5 13.9 14.5 14.0 14.3 14.8 15.4 14.8 15.2 15.7 16.3Hi PR 202 217 230 239 227 244 258 269 258 277 293 305 294 316 334 348 330 355 375 391 365 393 415 432Lo PR 98 105 114 122 104 111 121 129 108 115 125 134 113 121 132 140 119 127 138 147 123 131 143 1521050MBh 33.7 34.3 36.0 38.4 32.9 33.5 35.1 37.5 32.1 32.7 34.3 36.6 31.3 31.9 33.5 35.7 29.8 30.3 31.8 33.9 27.6 28.1 29.4 31.4S/T 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.93 0.76 1.00 1.00 0.96 0.78 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.82∆ T29 29 28 24 29 29 28 24 28 29 28 24 27 28 28 24 26 27 28 24 24 25 26 22kW1.95 2.00 2.09 2.18 2.16 2.22 2.32 2.42 2.34 2.41 2.51 2.62 2.50 2.58 2.69 2.80 2.64 2.72 2.84 2.96 2.76 2.84 2.96 3.09Amps 10.5 10.8 11.1 11.5 11.4 11.6 12.0 12.5 12.3 12.6 13.1 13.6 13.2 13.5 14.0 14.5 14.0 14.4 14.9 15.4 14.9 15.2 15.8 16.4Hi PR 203 218 230 240 227 245 258 269 259 278 294 306 294 317 335 349 331 356 376 393 366 394 416 434Lo PR 99 105 115 122 104 111 121 129 108 115 126 134 114 121 132 141 119 127 139 148 123 131 143 153IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects AHRI conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system powereXpAnded CoolinG dAtA — GSX130361C* / CA*f3642*6C* (Cont.) Product SPecificationS 12 www.goodmanmfg.com SS-GSX13 eXpAnded CoolinG dAtA — GSX130361e* / CA*f3636*6d*Outdoor Ambient Temperature65758595105115Entering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71701350MBh 32.9 34.1 37.4 - 32.2 33.3 36.5 - 31.4 32.5 35.7 - 30.6 31.7 34.8 - 29.1 30.2 33.0 - 27.0 27.9 30.6 -S/T 0.77 0.65 0.45 - 0.80 0.67 0.46 - 0.82 0.69 0.48 - 0.85 0.71 0.49 - 0.88 0.74 0.51 - 0.89 0.74 0.51 -∆ T17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 17 15 11 - 16 14 11 -kW2.44 2.49 2.55 - 2.61 2.65 2.73 - 2.75 2.80 2.88 - 2.88 2.94 3.02 - 2.99 3.05 3.14 - 3.08 3.14 3.24 -/anos 9.7 9.9 10.0 - 10.1 10.3 10.5 - 10.6 10.8 11.0 - 11.0 11.2 11.4 - 11.4 11.6 11.8 - 11.8 12.0 12.2 -Hi PR 183 197 208 - 205 221 234 - 234 252 266 - 266 286 302 - 299 322 340 - 331 356 376 -Lo PR 95 101 110 - 100 107 117 - 104 111 121 - 110 117 127 - 115 122 134 - 119 126 138 -1200MBh 32.0 33.1 36.3 - 31.2 32.4 35.5 - 30.5 31.6 34.6 - 29.7 30.8 33.8 - 28.2 29.3 32.1 - 26.2 27.1 29.7 -S/T 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -∆ T18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -kW2.42 2.47 2.54 - 2.59 2.64 2.71 - 2.73 2.78 2.86 - 2.86 2.91 3.00 - 2.96 3.02 3.11 - 3.06 3.12 3.21 -/anos 9.7 9.8 10.0 - 10.1 10.2 10.4 - 10.6 10.7 10.9 - 11.0 11.1 11.3 - 11.4 11.5 11.8 - 11.8 11.9 12.2 -Hi PR 181 195 206 - 203 219 231 - 231 249 263 - 264 284 299 - 296 319 337 - 328 353 372 -Lo PR 94 100 109 - 99 106 116 - 103 110 120 - 109 116 126 - 114 121 132 - 118 125 137 -1050MBh 29.5 30.6 33.5 - 28.8 29.9 32.7 - 28.1 29.2 31.9- 27.4 28.4 31.2 - 26.1 27.0 29.6 - 24.2 25.0 27.4 -S/T 0.71 0.59 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.82 0.68 0.47 -∆ T18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -kW2.37 2.42 2.48 - 2.53 2.58 2.65 - 2.67 2.72 2.80 - 2.79 2.85 2.93 - 2.90 2.96 3.04 - 2.99 3.05 3.14 -/anos 9.69.79.8 - 10.0 10.1 10.3 - 10.4 10.5 10.7 - 10.8 10.9 11.1 - 11.2 11.3 11.6 - 11.6 11.7 12.0 -Hi PR 176 189 200 - 197 212 224 - 224 242 255 - 256 275 291 - 288 309 327 - 318 342 361 -Lo PR 91 97 106 - 96 103 112 - 100 107 116 - 105 112 122 - 110 117 128 - 114 121 133 -751350MBh 33.5 34.5 37.3 40.0 32.7 33.7 36.4 39.1 31.9 32.9 35.6 38.2 31.132.134.7 37.3 29.6 30.5 33.0 35.4 27.4 28.2 30.5 32.8S/T 0.88 0.79 0.60 0.38 0.91 0.81 0.62 0.40 0.93 0.84 0.63 0.41 0.960.860.65 0.42 1.00 0.90 0.68 0.44 1.00 0.90 0.68 0.44∆ T20 18 15 10 20 19 15 11 20 19 15 11 201915 11 20 19 15 11 19 17 14 10kW2.46 2.50 2.57 2.65 2.62 2.67 2.75 2.83 2.77 2.82 2.91 2.99 2.902.963.04 3.14 3.01 3.07 3.16 3.26 3.10 3.17 3.26 3.36/anos 9.8 9.9 10.1 10.3 10.2 10.3 10.5 10.7 10.7 10.8 11.0 11.3 11.111.211.4 11.7 11.5 11.7 11.9 12.2 11.9 12.1 12.3 12.6Hi PR 185 199 210 219 208 223 236 246 236 254 268 280 269289306 319 303 326 344 359 334 360 380 396Lo PR 96 102 112 119 101 108 118 126 105 112 123 130 111118129 137 116 124 135 144 120 128 139 1491200MBh 32.5 33.5 36.2 38.9 31.8 32.7 35.4 38.0 31.0 31.9 34.5 37.1 30.231.133.7 36.2 28.7 29.6 32.0 34.4 26.6 27.4 29.7 31.8S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.60 0.39 0.920.820.62 0.40 0.95 0.85 0.65 0.42 0.96 0.86 0.65 0.42∆ T21 19 16 11 21 19 16 1121 19 16 11 212016 11 21 19 16 11 20 18 15 10kW2.44 2.49 2.56 2.63 2.61 2.66 2.73 2.81 2.75 2.80 2.89 2.97 2.882.943.02 3.11 2.99 3.05 3.14 3.23 3.08 3.14 3.24 3.34/anos 9.79.910.0 10.2 10.1 10.3 10.5 10.7 10.6 10.8 11.0 11.2 11.011.211.4 11.6 11.4 11.6 11.8 12.1 11.8 12.0 12.2 12.5Hi PR 183 197 208 217 206 221 234 244 234 252 266 277 266287303 316 300 322 340 355 331 356 376 392Lo PR 95 101 110 118 100 107 117 124 104 111 121 129 110117127 136 115 122 134 142 119 127 138 1471050MBh 30.0 30.9 33.4 35.9 29.3 30.2 32.7 35.1 28.6 29.5 31.9 34.2 27.928.731.1 33.4 26.5 27.3 29.6 31.7 24.6 25.3 27.4 29.4S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.890.790.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40∆ T21 20 16 11 21 20 16 11 22 20 16 11 222016 11 21 20 16 11 20 18 15 10kW2.39 2.43 2.50 2.57 2.55 2.60 2.67 2.75 2.69 2.74 2.82 2.90 2.812.872.95 3.04 2.92 2.98 3.07 3.16 3.01 3.07 3.16 3.26/anos 9.6 9.7 9.9 10.1 10.0 10.1 10.3 10.5 10.5 10.6 10.8 11.0 10.811.011.2 11.4 11.2 11.4 11.6 11.9 11.6 11.8 12.0 12.3Hi PR 178 191 202 211 199 215 227 236 227 244 258 269 258278293 306 291 313 330 344 321 345 365 380Lo PR 92 98 107 114 97 104 113 121 101 108 118 125 106113124 132 112 119 130 138 115 123 134 143IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects ACCA (TVA) conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system powerDesign Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions Product SPecificationS SS-GSX13 www.goodmanmfg.com 13 eXpAnded CoolinG dAtA — GSX130361e* / CA*f3636*6d* (Cont.)Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDBAirflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71801350MBh 34.1 34.8 37.2 39.8 33.3 34.0 36.3 38.8 32.5 33.2 35.5 37.9 31.7 32.4 34.6 37.0 30.1 30.8 32.9 35.1 27.9 28.5 30.5 32.6S/T 0.96 0.90 0.74 0.6 1.00 0.94 0.76 0.57 1.00 0.96 0.78 0.6 1.00 1.00 0.81 0.60 1.00 1.00 0.84 0.6 1.00 1.00 0.84 0.63∆ T22 21 19 15 23 22 19 15 22 22 19 15 22 22 19 15 21 21 19 15 19 19 18 14kW2.48 2.52 2.59 2.7 2.64 2.69 2.77 2.85 2.79 2.85 2.93 3.0 2.92 2.98 3.07 3.16 3.03 3.09 3.19 3.3 3.13 3.19 3.29 3.39/anos 9.8 10.0 10.1 10.3 10.2 10.4 10.6 10.8 10.7 10.9 11.1 11.3 11.1 11.3 11.5 11.8 11.5 11.7 12.0 12.2 12.0 12.1 12.4 12.7Hi PR 187 201 212 221.5 210 226 238 249 238 257 271 282.7 272 292 309 322 306 329 347 362.2 338 363 384 400Lo PR 97 103 113 120.0 103 109 119 127 107 113 124 131.8 112 119 130 138 117 125 136 145.1 121 129 141 1501200MBh 33.1 33.8 36.1 38.6 32.3 33.0 35.3 37.7 31.5 32.2 34.4 36.8 30.8 31.4 33.6 35.9 29.2 29.9 31.9 34.1 27.1 27.7 29.6 31.6S/T 0.92 0.86 0.70 0.5 0.95 0.89 0.73 0.54 0.98 0.92 0.75 0.6 1.00 0.95 0.77 0.58 1.00 0.98 0.80 0.6 1.00 0.99 0.81 0.60∆ T23 22 19 16 24 23 20 16 24 23 20 16 24 23 20 16 22 22 20 16 21 21 18 15kW2.46 2.50 2.57 2.6 2.62 2.67 2.75 2.83 2.77 2.82 2.91 3.0 2.90 2.96 3.05 3.14 3.01 3.07 3.16 3.3 3.10 3.17 3.26 3.36/anos 9.8 9.9 10.1 10.3 10.2 10.3 10.5 10.7 10.7 10.8 11.0 11.3 11.1 11.2 11.5 11.7 11.5 11.7 11.9 12.2 11.9 12.1 12.3 12.6Hi PR 185 199 210 219.3 208 223 236 246 236 254 268 279.9 269 289 306 319 303 326 344 358.6 334 360 380 396Lo PR 96 102 112 118.8 102 108 118 126 105 112 123 130.5 111 118 129 137 116 124 135 143.6 120 128 140 1491050MBh 30.5 31.2 33.3 35.6 29.8 30.5 32.6 34.8 29.1 29.8 31.834.0 28.4 29.0 31.0 33.2 27.0 27.6 29.5 31.5 25.0 25.5 27.3 29.2S/T 0.89 0.83 0.68 0.5 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.5 0.97 0.91 0.74 0.55 1.01 0.95 0.77 0.6 1.02 0.95 0.78 0.58∆ T24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 19 15kW2.41 2.45 2.52 2.6 2.57 2.62 2.69 2.77 2.71 2.76 2.84 2.9 2.84 2.89 2.98 3.07 2.94 3.00 3.09 3.2 3.03 3.10 3.19 3.29/anos 9.79.89.9 10.1 10.0 10.2 10.4 10.6 10.5 10.6 10.8 11.1 10.9 11.1 11.3 11.5 11.3 11.5 11.7 11.9 11.7 11.9 12.1 12.4Hi PR 179 193 204 212.7 201 217 229 239 229 246 260 271.5 261 281 296 309 293 316 333 347.8 324 349 368 384Lo PR 93 99 108 115.3 98 105 114 122 102 109 119 126.6 107 114 125 133 113 120 131 139.3 117 124 135 144851350MBh 34.7 35.3 37.0 39.5 33.9 34.5 36.2 38.6 33.1 33.7 35.3 37.7 32.3 32.9 34.4 36.7 30.6 31.2 32.7 34.9 28.4 28.9 30.3 32.3S/T 1.00 0.98 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.97 0.78 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.82∆ T24 23 22 19 23 24 22 19 23 23 22 19 22 22 23 20 21 21 22 19 19 20 21 18kW2.49 2.54 2.61 2.68 2.66 2.71 2.79 2.87 2.81 2.87 2.95 3.04 2.94 3.00 3.09 3.19 3.06 3.12 3.21 3.31 3.15 3.22 3.31 3.42/anos 9.9 10.0 10.2 10.4 10.3 10.4 10.6 10.8 10.8 10.9 11.1 11.4 11.2 11.4 11.6 11.8 11.6 11.8 12.0 12.3 12.0 12.2 12.5 12.7Hi PR 189 203 214 224 212 228 241 251 241 259 274 285 274 295 312 325 309 332 351 366 341 367 387 404Lo PR 98 104 114 121 104 110 120 128 108 114 125 133 113 120 131 140 118 126 138 147 123 130 142 1521200MBh 33.7 34.3 35.9 38.3 32.9 33.5 35.1 37.5 32.1 32.7 34.3 36.6 31.3 31.9 33.4 35.7 29.7 30.3 31.8 33.9 27.6 28.1 29.4 31.4S/T 0.96 0.93 0.84 0.68 1.00 0.96 0.87 0.71 1.00 0.99 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.96 0.78∆ T25 24 23 20 25 25 23 2025 25 23 20 24 24 24 20 23 23 23 20 21 22 22 19kW2.48 2.52 2.59 2.67 2.64 2.69 2.77 2.85 2.79 2.85 2.93 3.02 2.92 2.98 3.07 3.16 3.03 3.09 3.19 3.28 3.13 3.19 3.29 3.39/anos 9.810.010.1 10.3 10.2 10.4 10.6 10.8 10.7 10.9 11.1 11.3 11.1 11.3 11.5 11.8 11.5 11.7 12.0 12.2 12.0 12.1 12.4 12.7Hi PR 187 201 212 221 210 226 238 249 238 257 271 283 272 292 309 322 306 329 347 362 338 363 384 400Lo PR 97 103 113 120 103 109 119 127 107 113 124 132 112 119 130 138 117 125 136 145 121 129 141 1501050MBh 31.1 31.7 33.2 35.4 30.3 30.9 32.4 34.6 29.6 30.2 31.6 33.7 28.9 29.5 30.9 32.9 27.5 28.0 29.3 31.3 25.4 25.9 27.2 29.0S/T 0.93 0.90 0.81 0.66 0.96 0.93 0.84 0.68 0.99 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.93 0.75∆ T25 25 24 20 26 25 24 21 26 25 24 21 25 25 24 21 24 25 24 20 22 23 22 19kW2.42 2.47 2.54 2.61 2.59 2.64 2.71 2.79 2.73 2.78 2.86 2.95 2.86 2.91 3.00 3.09 2.96 3.02 3.11 3.21 3.06 3.12 3.21 3.31/anos 9.7 9.8 10.0 10.2 10.1 10.2 10.4 10.6 10.6 10.7 10.9 11.1 11.0 11.1 11.3 11.6 11.4 11.5 11.7 12.0 11.8 11.9 12.2 12.5Hi PR 181 195 206 215 203 219 231 241 231 249 263 274 263 284 299 312 296 319 337 351 327 352 372 388Lo PR 94 100 109 116 99 106 115 123 103 110 120 128 109 115 126 134 114 121 132 141 118 125 137 146IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects AHRI conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system powerDesign Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions Product SPecificationS 14 www.goodmanmfg.com SS-GSX13 eXpAnded CoolinG dAtA — GSX130421B* / CA*f3642*6B*Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71701225MBh 36.0 37.3 40.9 - 35.2 36.4 39.9 - 34.3 35.6 39.0 - 33.5 34.7 38.0 - 31.8 33.0 36.1 - 29.5 30.5 33.5 -S/T 0.69 0.57 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.79 0.66 0.46 -∆ T19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -kW2.78 2.84 2.92 - 2.98 3.04 3.13 - 3.15 3.21 3.31 - 3.30 3.37 3.47 - 3.43 3.50 3.61 - 3.54 3.61 3.73 -Amps 10.7 10.9 11.2 - 11.5 11.8 12.1 - 12.5 12.7 13.2 - 13.3 13.6 14.0 - 14.1 14.5 14.9 - 14.9 15.3 15.8 -Hi PR 209 225 238 - 235 253 267 - 267 288 304 - 304 328 346 - 343 369 389 - 378 407 430 -Lo PR 101 107 117 - 106 113 124 - 111 118 129 - 116 124 135 - 122 130 141 - 126 134 146 -1400MBh 39.0 40.4 44.3 - 38.1 39.5 43.3 - 37.2 38.5 42.2 - 36.3 37.6 41.2 - 34.5 35.7 39.1 - 31.9 33.1 36.3 -S/T 0.71 0.59 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.82 0.68 0.47 -∆ T18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -kW2.84 2.90 2.98 - 3.05 3.11 3.20 - 3.22 3.29 3.39 - 3.38 3.45 3.55 - 3.51 3.58 3.70 - 3.63 3.70 3.82 -Amps 10.9 11.2 11.6 - 11.8 12.1 12.5 - 12.8 13.1 13.5 - 13.7 14.0 14.4 - 14.5 14.9 15.3 - 15.4 15.7 16.2 -Hi PR 216 232 245 - 242 261 275 - 276 297 313 - 314 338 357 - 353 380 401 - 390 420 443 -Lo PR 104 111 121 - 110 117 127 - 114 121 132 - 120 127 139 - 126 134 146 - 130 138 151 -1575MBh 40.2 41.6 45.6 - 39.2 40.7 44.6 - 38.3 39.7 43.5- 37.4 38.7 42.4 - 35.5 36.8 40.3 - 32.9 34.1 37.3 -S/T 0.75 0.62 0.43 - 0.77 0.65 0.45 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.86 0.72 0.50 -∆ T18 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -kW2.87 2.92 3.01 - 3.07 3.13 3.22 - 3.25 3.31 3.41 - 3.41 3.48 3.58 - 3.54 3.61 3.73 - 3.66 3.73 3.85 -Amps 11.011.311.7 - 11.9 12.2 12.6 - 12.9 13.2 13.6 - 13.8 14.1 14.6 - 14.6 15.0 15.5 - 15.5 15.9 16.4 -Hi PR 218 235 248 - 245 263 278 - 278 300 316 - 317 341 360 - 357 384 405 - 394 424 448 -Lo PR 105 112 122 - 111 118 129 - 115 123 134 - 121 129 141 - 127 135 147 - 131 140 152 -751225MBh 36.6 37.7 40.8 43.8 35.8 36.8 39.9 42.8 34.9 35.9 38.9 41.8 34.135.138.0 40.7 32.4 33.3 36.1 38.7 30.0 30.9 33.4 35.8S/T 0.78 0.70 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.860.770.58 0.37 0.89 0.79 0.60 0.39 0.90 0.80 0.61 0.39∆ T21 20 16 11 22 20 16 11 22 20 16 11 222017 11 22 20 16 11 20 19 15 10kW2.80 2.86 2.94 3.03 3.00 3.06 3.15 3.24 3.17 3.24 3.33 3.44 3.333.393.50 3.61 3.46 3.53 3.64 3.75 3.57 3.64 3.76 3.88Amps 10.8 11.0 11.3 11.8 11.6 11.9 12.2 12.7 12.6 12.9 13.3 13.8 13.413.714.2 14.7 14.2 14.6 15.1 15.6 15.1 15.4 15.9 16.5Hi PR 212 228 240 251 237 256 270 281 270 291 307 320 308331350 365 346 372 393 410 382 411 434 453Lo PR 102 108 118 126 108 114 125 133 112 119 130 138 117125136 145 123 131 143 152 127 135 148 1571400MBh 39.7 40.8 44.2 47.4 38.7 39.9 43.2 46.3 37.8 38.9 42.2 45.2 36.938.041.1 44.1 35.1 36.1 39.1 41.9 32.5 33.4 36.2 38.8S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.37 0.86 0.77 0.58 0.37 0.890.790.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40∆ T21 19 16 11 21 20 16 1121 20 16 11 222016 11 21 20 16 11 20 18 15 10kW2.87 2.92 3.01 3.10 3.07 3.13 3.22 3.32 3.25 3.31 3.41 3.52 3.413.483.58 3.70 3.54 3.61 3.73 3.84 3.66 3.73 3.85 3.97Amps 11.011.311.7 12.1 11.9 12.2 12.6 13.0 12.9 13.2 13.6 14.1 13.814.114.6 15.1 14.6 15.0 15.5 16.1 15.5 15.9 16.4 17.0Hi PR 218 235 248 259 245 263 278 290 278 300 316 330 317341360 376 357 384 405 423 394 424 448 467Lo PR 105 112 122 130 111 118 129 137 115 123 134 143 121129141 150 127 135 147 157 131 140 152 1621575MBh 40.9 42.1 45.5 48.9 39.9 41.1 44.5 47.7 39.0 40.1 43.4 46.6 38.039.142.4 45.5 36.1 37.2 40.2 43.2 33.4 34.4 37.3 40.0S/T 0.85 0.76 0.57 0.37 0.88 0.79 0.60 0.38 0.90 0.81 0.61 0.39 0.930.830.63 0.41 0.97 0.86 0.65 0.42 0.97 0.87 0.66 0.42∆ T20 19 15 11 20 19 15 11 21 19 15 11 211916 11 20 19 15 11 19 18 14 10kW2.89 2.94 3.03 3.12 3.09 3.15 3.25 3.35 3.27 3.34 3.44 3.55 3.433.503.61 3.72 3.57 3.64 3.76 3.87 3.68 3.76 3.88 4.00Amps 11.1 11.4 11.8 12.2 12.0 12.3 12.7 13.2 13.0 13.3 13.8 14.3 13.914.214.7 15.2 14.8 15.1 15.6 16.2 15.6 16.0 16.5 17.2Hi PR 220 237 250 261 247 266 281 293 281 303 320 333 320345364 380 360 388 409 427 398 428 452 472Lo PR 106 113 123 131 112 119 130 139 116 124 135 144 122130142 151 128 136 149 158 133 141 154 164IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects ACCA (TVA) conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS SS-GSX13 www.goodmanmfg.com 15 eXpAnded CoolinG dAtA — GSX130421B* / CA*f3642*6B* (Cont.)Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71801225MBh 37.3 38.1 40.7 43.5 36.4 37.2 39.7 42.5 35.5 36.3 38.8 41.5 34.7 35.4 37.8 40.5 32.9 33.6 36.0 38.4 30.5 31.2 33.3 35.6S/T 0.86 0.80 0.65 0.49 0.89 0.83 0.68 0.51 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.56 0.98 0.92 0.75 0.56∆ T24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 22 19 15kW2.82 2.88 2.96 3.05 3.02 3.08 3.17 3.27 3.20 3.26 3.36 3.46 3.35 3.42 3.53 3.64 3.48 3.56 3.67 3.78 3.60 3.67 3.79 3.91Amps 10.8 11.1 11.4 11.9 11.7 12.0 12.4 12.8 12.7 13.0 13.4 13.9 13.5 13.8 14.3 14.8 14.4 14.7 15.2 15.8 15.2 15.6 16.1 16.7Hi PR 214 230 243 253 240 258 273 284 273 294 310 323 311 334 353 368 350 376 397 414 386 416 439 458Lo PR 103 109 119 127 109 116 126 134 113 120 131 140 119 126 138 147 124 132 144 154 129 137 149 1591400MBh 40.4 41.3 44.1 47.1 39.4 40.3 43.1 46.0 38.5 39.3 42.0 44.9 37.6 38.441.043.8 35.7 36.5 39.0 41.6 33.0 33.8 36.1 38.6S/T 0.89 0.83 0.68 0.51 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.54 0.97 0.910.740.56 1.00 0.95 0.77 0.58 1.00 0.96 0.78 0.58∆ T24 23 20 16 24 23 20 16 24 23 20 16 24 232016 23 23 20 16 22 21 18 15kW2.89 2.94 3.03 3.12 3.09 3.15 3.25 3.35 3.27 3.34 3.44 3.55 3.43 3.503.613.72 3.57 3.64 3.76 3.88 3.68 3.76 3.88 4.01Amps 11.1 11.4 11.8 12.2 12.0 12.3 12.7 13.2 13.0 13.3 13.8 14.3 13.9 14.214.715.2 14.8 15.1 15.6 16.2 15.6 16.0 16.5 17.2Hi PR 220 237 250 261 247 266 281 293 281 303 320 333 320 345364380 360 388 410 427 398 428 452 472Lo PR 106 113 123 131 112 119 130 139 116 124 135 144 122 130142151 128 136 149 158 133 141 154 1641575MBh 41.6 42.5 45.4 48.5 40.6 41.5 44.3 47.4 39.6 40.5 43.346.3 38.7 39.5 42.2 45.1 36.7 37.6 40.1 42.9 34.0 34.8 37.2 39.7S/T 0.93 0.87 0.71 0.53 0.96 0.90 0.74 0.55 1.00 0.93 0.75 0.56 1.00 0.96 0.78 0.58 1.00 1.00 0.81 0.60 1.00 1.00 0.82 0.61∆ T23 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 21 22 19 15 20 20 18 14kW2.91 2.96 3.05 3.14 3.11 3.18 3.27 3.37 3.30 3.36 3.47 3.58 3.46 3.53 3.64 3.75 3.60 3.67 3.79 3.91 3.71 3.79 3.91 4.04Amps 11.211.511.9 12.3 12.1 12.4 12.8 13.3 13.1 13.5 13.9 14.4 14.0 14.4 14.8 15.4 14.9 15.3 15.8 16.4 15.8 16.2 16.7 17.3Hi PR 223 240 253 264 250 269 284 296 284 306 323 337 324 348 368 383 364 392 414 431 402 433 457 477Lo PR 107 114 124 132 113 120 131 140 118 125 137 145 123 131 143 153 129 138 150 160 134 142 155 166851225MBh 37.9 38.6 40.5 43.2 37.0 37.7 39.5 42.2 36.2 36.9 38.6 41.2 35.3 36.0 37.7 40.2 33.5 34.2 35.8 38.2 31.0 31.6 33.1 35.4S/T 0.90 0.87 0.78 0.63 0.93 0.90 0.81 0.66 0.95 0.92 0.83 0.67 0.98 0.95 0.86 0.70 1.00 0.99 0.89 0.72 1.00 0.99 0.90 0.73∆ T26 25 24 21 26 25 24 21 26 25 24 21 26 26 24 21 25 25 24 21 23 24 22 19kW2.84 2.90 2.98 3.07 3.04 3.11 3.20 3.29 3.22 3.29 3.39 3.49 3.38 3.45 3.55 3.66 3.51 3.58 3.70 3.81 3.63 3.70 3.82 3.94Amps 10.9 11.2 11.6 12.0 11.8 12.1 12.5 12.9 12.8 13.1 13.5 14.0 13.6 14.0 14.4 15.0 14.5 14.9 15.3 15.9 15.4 15.7 16.2 16.8Hi PR 216 232 245 256 242 261 275 287 276 297 313 327 314 338 357 372 353 380 401 418 390 420 443 462Lo PR 104 110 121 128 110 117 127 136 114 121 132 141 120 127 139 148 126 134 146 155 130 138 151 1611400MBh 41.1 41.9 43.9 46.8 40.1 40.9 42.8 45.7 39.2 39.9 41.8 44.6 38.2 39.0 40.8 43.5 36.3 37.0 38.8 41.3 33.6 34.3 35.9 38.3S/T 0.93 0.90 0.81 0.66 0.96 0.93 0.84 0.68 0.99 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.93 0.75∆ T25 25 23 20 25 25 24 2025 25 24 20 25 25 24 21 24 24 23 20 22 23 22 19kW2.91 2.96 3.05 3.14 3.11 3.18 3.27 3.37 3.30 3.36 3.47 3.58 3.46 3.53 3.64 3.75 3.60 3.67 3.79 3.91 3.71 3.79 3.91 4.04Amps 11.211.511.9 12.3 12.1 12.4 12.8 13.3 13.1 13.5 13.9 14.4 14.0 14.4 14.8 15.4 14.9 15.3 15.8 16.4 15.8 16.2 16.7 17.3Hi PR 223 240 253 264 250 269 284 296 284 306 323 337 324 348 368 383 364 392 414 431 402 433 457 477Lo PR 107 114 124 132 113 120 131 140 118 125 137 145 123 131 143 153 129 138 150 160 134 142 155 1661575MBh 42.3 43.1 45.2 48.2 41.3 42.1 44.1 47.1 40.3 41.1 43.1 45.9 39.4 40.1 42.0 44.8 37.4 38.1 39.9 42.6 34.6 35.3 37.0 39.4S/T 0.98 0.94 0.85 0.69 1.00 0.98 0.88 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.97 0.78 1.00 1.00 0.98 0.79∆ T24 24 22 19 24 24 23 20 24 24 23 20 23 23 23 20 22 22 23 20 20 21 21 18kW2.93 2.99 3.07 3.17 3.14 3.20 3.30 3.40 3.32 3.39 3.49 3.60 3.49 3.56 3.67 3.78 3.62 3.70 3.82 3.94 3.74 3.82 3.94 4.07Amps 11.3 11.6 12.0 12.4 12.2 12.5 12.9 13.4 13.3 13.6 14.0 14.5 14.2 14.5 15.0 15.5 15.0 15.4 15.9 16.5 15.9 16.3 16.9 17.5Hi PR 225 242 255 266 252 271 287 299 287 309 326 340 327 352 371 387 368 396 418 436 406 437 462 481Lo PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects AHRI conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS 16 www.goodmanmfg.com SS-GSX13 eXpAnded CoolinG dAtA — GSX130481B* / CA*f4860*6B*Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71701400MBh 40.4 41.9 45.9 - 39.5 40.9 44.8 - 38.5 39.9 43.7 - 37.6 38.9 42.7 - 35.7 37.0 40.5 - 33.1 34.3 37.5 -S/T 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.81 0.68 0.47 -∆ T19 16 12 - 19 16 12 - 19 16 13 - 19 17 13 - 19 16 12 - 18 15 12 -kW3.17 3.23 3.32 - 3.39 3.46 3.56 - 3.59 3.66 3.77 - 3.77 3.84 3.96 - 3.91 4.00 4.12 - 4.04 4.13 4.26 -Amps 11.6 11.9 12.3 - 12.6 12.9 13.3 - 13.7 14.0 14.5 - 14.6 15.0 15.5 - 15.5 15.9 16.5 - 16.5 16.9 17.4 -Hi PR 215 231 244 - 241 259 274 - 274 295 311 - 312 336 354 - 351 377 399 - 388 417 440 -Lo PR 104 111 121 - 110 117 128 - 115 122 133 - 120 128 140 - 126 134 146 - 130 139 151 -1600MBh 43.8 45.4 49.7 - 42.7 44.3 48.5 - 41.7 43.2 47.4 - 40.7 42.2 46.2 - 38.7 40.1 43.9 - 35.8 37.1 40.7 -S/T 0.73 0.61 0.43 - 0.76 0.64 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.84 0.70 0.48 - 0.84 0.70 0.49 -∆ T18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -kW3.24 3.30 3.40 - 3.47 3.54 3.65 - 3.67 3.75 3.87 - 3.86 3.94 4.06 - 4.01 4.09 4.22 - 4.14 4.23 4.36 -Amps 12.0 12.3 12.7 - 12.9 13.2 13.7 - 14.1 14.4 14.9 - 15.0 15.4 15.9 - 16.0 16.4 16.9 - 16.9 17.4 17.9 -Hi PR 221 238 251 - 248 267 282 - 282 304 321 - 321 346 365 - 362 389 411 - 400 430 454 -Lo PR 108 114 125 - 114 121 132 - 118 126 137 - 124 132 144 - 130 138 151 - 134 143 156 -1800MBh 45.1 46.7 51.2 - 44.0 45.6 50.0 - 43.0 44.5 48.8- 41.9 43.5 47.6 - 39.8 41.3 45.2 - 36.9 38.2 41.9 -S/T 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.88 0.73 0.51 - 0.88 0.74 0.51 -∆ T18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 15 12 - 17 14 11 -kW3.26 3.33 3.42 - 3.50 3.57 3.67 - 3.70 3.78 3.90 - 3.89 3.97 4.09 - 4.04 4.13 4.26 - 4.18 4.26 4.40 -Amps 12.112.412.8 - 13.0 13.4 13.8 - 14.2 14.5 15.0 - 15.2 15.5 16.0 - 16.1 16.5 17.1 - 17.1 17.5 18.1 -Hi PR 223 240 254 - 251 270 285 - 285 307 324 - 325 349 369 - 365 393 415 - 404 434 459 -Lo PR 109 116 126 - 115 122 133 - 119 127 139 - 125 133 146 - 131 140 152 - 136 144 158 -751400MBh 41.1 42.3 45.8 49.1 40.1 41.3 44.7 48.0 39.2 40.3 43.7 46.8 38.239.342.6 45.7 36.3 37.4 40.5 43.4 33.6 34.6 37.5 40.2S/T 0.81 0.72 0.55 0.35 0.83 0.75 0.56 0.36 0.86 0.77 0.58 0.37 0.880.790.60 0.38 0.92 0.82 0.62 0.40 0.92 0.83 0.63 0.40∆ T22 20 16 11 22 20 17 11 22 20 17 11 222017 12 22 20 16 11 20 19 15 11kW3.19 3.25 3.35 3.45 3.42 3.49 3.59 3.70 3.62 3.69 3.80 3.92 3.793.873.99 4.12 3.95 4.03 4.15 4.29 4.08 4.16 4.29 4.43Amps 11.7 12.0 12.4 12.9 12.7 13.0 13.4 13.9 13.8 14.1 14.6 15.1 14.715.115.6 16.2 15.7 16.1 16.6 17.2 16.6 17.0 17.6 18.3Hi PR 217 233 246 257 243 262 276 288 277 298 314 328 315339358 373 354 381 403 420 391 421 445 464Lo PR 105 112 122 130 111 118 129 138 116 123 134 143 122129141 150 127 136 148 158 132 140 153 1631600MBh 44.5 45.8 49.6 53.2 43.5 44.8 48.4 52.0 42.4 43.7 47.3 50.8 41.442.646.1 49.5 39.3 40.5 43.8 47.0 36.4 37.5 40.6 43.6S/T 0.84 0.75 0.57 0.36 0.87 0.77 0.59 0.38 0.89 0.79 0.60 0.39 0.920.820.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.65 0.42∆ T21 20 16 11 22 20 16 1122 20 16 11 222016 11 21 20 16 11 20 18 15 10kW3.26 3.33 3.42 3.53 3.50 3.57 3.68 3.79 3.70 3.78 3.90 4.02 3.893.974.09 4.22 4.04 4.13 4.26 4.39 4.18 4.26 4.40 4.54Amps 12.112.412.8 13.2 13.1 13.4 13.8 14.3 14.2 14.5 15.0 15.6 15.215.516.1 16.7 16.1 16.5 17.1 17.7 17.1 17.5 18.1 18.8Hi PR 223 240 254 265 251 270 285 297 285 307 324 338 325349369 385 365 393 415 433 404 434 459 478Lo PR 109 116 126 134 115 122 133 142 119 127 139 148 125133146 155 131 140 153 162 136 145 158 1681800MBh 45.8 47.2 51.1 54.8 44.8 46.1 49.9 53.6 43.7 45.0 48.7 52.3 42.643.947.5 51.0 40.5 41.7 45.1 48.5 37.5 38.6 41.8 44.9S/T 0.88 0.78 0.59 0.38 0.91 0.81 0.61 0.40 0.93 0.83 0.63 0.41 0.960.860.65 0.42 1.00 0.89 0.67 0.43 1.00 0.90 0.68 0.44∆ T21 19 15 11 21 19 16 11 21 19 16 11 211916 11 21 19 16 11 19 18 15 10kW3.29 3.35 3.45 3.55 3.52 3.59 3.70 3.82 3.73 3.81 3.93 4.05 3.924.004.12 4.26 4.07 4.16 4.29 4.43 4.21 4.30 4.44 4.58Amps 12.2 12.5 12.9 13.4 13.2 13.5 13.9 14.5 14.3 14.7 15.1 15.7 15.315.716.2 16.8 16.3 16.7 17.2 17.9 17.3 17.7 18.3 19.0Hi PR 226 243 256 267 253 272 288 300 288 310 327 341 328353373 389 369 397 419 437 408 439 463 483Lo PR 110 117 127 136 116 123 135 143 120 128 140 149 127135147 157 133 141 154 164 137 146 159 170IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects ACCA (TVA) conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS SS-GSX13 www.goodmanmfg.com 17 eXpAnded CoolinG dAtA — GSX130481B* / CA*f4860*6B* (Cont.)Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71801400MBh 41.8 42.7 45.6 48.8 40.8 41.7 44.6 47.7 39.9 40.7 43.5 46.5 38.9 39.7 42.5 45.4 36.9 37.8 40.3 43.1 34.2 35.0 37.4 39.9S/T 0.88 0.83 0.67 0.50 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 1.01 0.94 0.77 0.57 1.01 0.95 0.77 0.58∆ T24 23 20 16 25 24 20 16 25 24 20 16 25 24 21 16 24 23 20 16 23 22 19 15kW3.21 3.28 3.37 3.47 3.44 3.51 3.62 3.73 3.65 3.72 3.83 3.95 3.82 3.90 4.03 4.15 3.98 4.06 4.19 4.32 4.11 4.20 4.33 4.47Amps 11.9 12.1 12.5 13.0 12.8 13.1 13.6 14.1 13.9 14.3 14.7 15.3 14.9 15.2 15.8 16.3 15.8 16.2 16.8 17.4 16.8 17.2 17.8 18.5Hi PR 219 236 249 259 246 264 279 291 279 301 317 331 318 342 362 377 358 385 407 424 395 426 449 469Lo PR 106 113 124 132 112 120 131 139 117 124 136 145 123 131 143 152 129 137 149 159 133 142 155 1651600MBh 45.3 46.3 49.5 52.9 44.2 45.2 48.3 51.6 43.2 44.1 47.2 50.4 42.1 43.146.049.2 40.0 40.9 43.7 46.7 37.1 37.9 40.5 43.3S/T 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97 0.91 0.74 0.56 1.00 0.940.770.57 1.00 0.98 0.80 0.60 1.00 0.99 0.80 0.60∆ T24 23 20 16 24 23 20 16 24 23 20 16 24 232016 23 23 20 16 21 21 19 15kW3.29 3.35 3.45 3.56 3.52 3.59 3.70 3.82 3.73 3.81 3.93 4.05 3.92 4.004.124.26 4.07 4.16 4.29 4.43 4.21 4.30 4.44 4.58Amps 12.2 12.5 12.9 13.4 13.2 13.5 13.9 14.5 14.3 14.7 15.2 15.7 15.3 15.716.216.8 16.3 16.7 17.3 17.9 17.3 17.7 18.3 19.0Hi PR 226 243 256 267 253 272 288 300 288 310 327 341 328 353373389 369 397 419 437 408 439 463 483Lo PR 110 117 127 136 116 123 135 143 120 128 140 149 127 135147157 133 141 154 164 137 146 159 1701800MBh 46.7 47.7 50.9 54.4 45.6 46.6 49.7 53.2 44.5 45.5 48.651.9 43.4 44.3 47.4 50.6 41.2 42.1 45.0 48.1 38.2 39.0 41.7 44.6S/T 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.84 0.63∆ T23 22 19 15 23 22 19 15 23 22 19 15 22 23 19 16 21 22 19 15 20 20 18 14kW3.31 3.38 3.48 3.58 3.55 3.62 3.73 3.85 3.76 3.84 3.96 4.08 3.95 4.03 4.16 4.29 4.11 4.19 4.33 4.47 4.24 4.33 4.47 4.62Amps 12.312.613.0 13.5 13.3 13.6 14.1 14.6 14.4 14.8 15.3 15.9 15.4 15.8 16.4 17.0 16.4 16.8 17.4 18.1 17.4 17.9 18.5 19.2Hi PR 228 245 259 270 256 275 291 303 291 313 331 345 331 356 376 393 373 401 423 442 412 443 468 488Lo PR 111 118 129 137 117 125 136 145 122 129 141 151 128 136 148 158 134 143 156 166 139 147 161 171851400MBh 42.5 43.4 45.4 48.5 41.5 42.4 44.4 47.3 40.6 41.3 43.3 46.2 39.6 40.3 42.2 45.1 37.6 38.3 40.1 42.8 34.8 35.5 37.2 39.7S/T 0.93 0.89 0.81 0.65 0.96 0.93 0.84 0.68 0.98 0.95 0.86 0.70 1.00 0.98 0.88 0.72 1.00 1.00 0.92 0.74 1.00 1.00 0.93 0.75∆ T26 25 24 21 26 26 24 21 26 26 24 21 26 26 25 21 25 25 24 21 23 23 23 20kW3.24 3.30 3.40 3.50 3.47 3.54 3.65 3.76 3.67 3.75 3.86 3.99 3.85 3.94 4.06 4.19 4.01 4.09 4.22 4.36 4.14 4.23 4.36 4.50Amps 12.0 12.2 12.6 13.1 12.9 13.2 13.7 14.2 14.0 14.4 14.9 15.4 15.0 15.4 15.9 16.5 16.0 16.4 16.9 17.6 16.9 17.4 17.9 18.6Hi PR 221 238 251 262 248 267 282 294 282 304 321 334 321 346 365 381 361 389 411 428 399 430 454 473Lo PR 108 114 125 133 114 121 132 140 118 126 137 146 124 132 144 153 130 138 151 161 134 143 156 1661600MBh 46.1 47.0 49.2 52.5 45.0 45.9 48.1 51.3 43.9 44.8 46.9 50.1 42.9 43.7 45.8 48.8 40.7 41.5 43.5 46.4 37.7 38.5 40.3 43.0S/T 0.96 0.93 0.84 0.68 1.00 0.96 0.87 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.96 0.78∆ T25 25 24 20 26 25 24 2125 25 24 21 25 25 24 21 23 24 24 21 22 22 22 19kW3.31 3.38 3.48 3.58 3.55 3.62 3.73 3.85 3.76 3.84 3.96 4.08 3.95 4.03 4.16 4.29 4.11 4.19 4.33 4.47 4.24 4.33 4.47 4.62Amps 12.312.613.0 13.5 13.3 13.6 14.1 14.6 14.4 14.8 15.3 15.9 15.4 15.8 16.4 17.0 16.4 16.8 17.4 18.1 17.4 17.9 18.5 19.2Hi PR 228 245 259 270 256 275 291 303 291 313 331 345 331 356 376 393 373 401 423 442 412 443 468 488Lo PR 111 118 129 137 117 125 136 145 122 129 141 151 128 136 148 158 134 143 156 166 139 147 161 1711800MBh 47.5 48.4 50.7 54.1 46.4 47.3 49.5 52.8 45.3 46.1 48.3 51.6 44.2 45.0 47.1 50.3 42.0 42.8 44.8 47.8 38.9 39.6 41.5 44.3S/T 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.93 0.76 1.00 1.00 0.96 0.78 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.82∆ T24 24 23 20 24 24 23 20 23 24 23 20 23 23 23 20 21 22 23 20 20 20 21 18kW3.34 3.40 3.50 3.61 3.58 3.65 3.76 3.88 3.79 3.87 3.99 4.11 3.98 4.06 4.19 4.32 4.14 4.23 4.36 4.50 4.28 4.37 4.51 4.65Amps 12.4 12.7 13.1 13.6 13.4 13.7 14.2 14.7 14.6 14.9 15.4 16.0 15.6 16.0 16.5 17.1 16.6 17.0 17.6 18.2 17.6 18.0 18.6 19.3Hi PR 230 248 262 273 258 278 294 306 294 316 334 348 335 360 380 397 376 405 428 446 416 448 473 493Lo PR 112 119 130 138 118 126 137 146 123 131 143 152 129 137 150 160 135 144 157 167 140 149 163 173IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects AHRI conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS 18 www.goodmanmfg.com SS-GSX13 eXpAnded CoolinG dAtA — GSX130601B* / CA*f4961*6A*Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71701500MBh 50.1 51.9 56.8 - 48.9 50.7 55.5 - 47.7 49.5 54.2 - 46.6 48.3 52.9 - 44.2 45.8 50.2 - 41.0 42.5 46.5 -S/T 0.67 0.56 0.39 - 0.69 0.58 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.76 0.64 0.44 - 0.77 0.64 0.44 -∆T21 18 13 - 21 18 14 - 21 18 14 - 21 18 14 - 21 18 14 - 19 17 13 -kW3.87 3.95 4.07 - 4.16 4.24 4.38 - 4.41 4.50 4.65 - 4.63 4.73 4.89 - 4.82 4.93 5.09 - 4.99 5.10 5.26 -Amps 14.4 14.8 15.3 - 15.6 16.0 16.5 - 17.0 17.4 18.0 - 18.2 18.6 19.2 - 19.3 19.8 20.5 - 20.5 21.0 21.7 -HI PR 229 246 260 - 257 276 292 - 292 314 332 - 333 358 378 - 374 403 425 - 413 445 470 -LO PR 101 108 118 - 107 114 125 - 111 119 129 - 117 125 136 - 123 130 142 - 127 135 147 -1750MBh 54.2 56.2 61.6 - 53.0 54.9 60.1 - 51.7 53.6 58.7 - 50.4 52.3 57.3 - 47.9 49.7 54.4 - 44.4 46.0 50.4 -S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -∆T20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 19 16 12 -kW3.96 4.04 4.17 - 4.26 4.35 4.48 - 4.52 4.62 4.76 - 4.75 4.85 5.01 - 4.95 5.05 5.22 - 5.12 5.23 5.40 -Amps 14.8 15.2 15.7 - 16.1 16.4 17.0 - 17.5 17.9 18.5 - 18.7 19.1 19.8 - 19.9 20.4 21.1 - 21.1 21.6 22.4 -HI PR 236 254 268 - 265 285 301 - 301 324 342 - 343 369 390 - 386 415 438 - 426 459 484 -LO PR 105 111 122 - 111 118 128 - 115 122 133 - 121 128 140 - 126 135 147 - 131 139 152 -2000MBh 55.9 57.9 63.4 - 54.6 56.5 62.0 - 53.3 55.2 60.5- 52.0 53.9 59.0 - 49.4 51.2 56.1 - 45.7 47.4 51.9 -S/T 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.77 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -∆T19 16 12 - 19 16 12 - 19 16 12 - 19 16 13 - 19 16 12 - 18 15 12 -kW3.99 4.07 4.20 - 4.29 4.38 4.52 - 4.56 4.65 4.80 - 4.79 4.89 5.05 - 4.99 5.10 5.26 - 5.16 5.27 5.44 -Amps 15.015.315.8 - 16.2 16.6 17.2 - 17.6 18.1 18.7 - 18.9 19.3 20.0 - 20.1 20.6 21.3 - 21.3 21.8 22.6 -HI PR 238 256 271 - 267 288 304 - 304 327 346 - 346 373 394 - 390 419 443 - 430 463 489 -LO PR 106 112 123 - 112 119 130 - 116 123 135 - 122 130 142 - 128 136 148 - 132 141 153 -751500MBh 50.9 52.4 56.7 60.9 49.7 51.2 55.4 59.5 48.5 50.0 54.1 58.1 47.348.852.8 56.6 45.0 46.3 50.1 53.8 41.7 42.9 46.4 49.8S/T 0.76 0.68 0.51 0.33 0.79 0.70 0.53 0.34 0.81 0.72 0.55 0.35 0.830.750.56 0.36 0.87 0.77 0.59 0.38 0.87 0.78 0.59 0.38∆T24 22 18 12 24 22 18 13 24 22 18 13 242218 13 24 22 18 12 22 21 17 12kW3.90 3.98 4.10 4.23 4.19 4.28 4.41 4.55 4.45 4.54 4.68 4.84 4.674.774.93 5.09 4.86 4.97 5.13 5.30 5.03 5.14 5.31 5.48Amps 14.6 14.9 15.4 16.0 15.8 16.1 16.7 17.3 17.1 17.6 18.1 18.8 18.318.819.4 20.2 19.5 20.0 20.7 21.5 20.7 21.2 21.9 22.8HI PR 231 249 263 274 259 279 295 307 295 317 335 350 336362382 398 378 407 430 448 418 449 475 495LO PR 103 109 119 127 108 115 126 134 113 120 131 139 118126137 146 124 132 144 153 128 136 149 1591750MBh 55.1 56.8 61.5 66.0 53.9 55.5 60.0 64.4 52.6 54.1 58.6 62.9 51.352.857.2 61.4 48.7 50.2 54.3 58.3 45.1 46.5 50.3 54.0S/T 0.79 0.71 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.860.770.59 0.38 0.90 0.80 0.61 0.39 0.91 0.81 0.61 0.39∆T23 21 17 12 23 21 17 1223 21 17 12 232118 12 23 21 17 12 21 20 16 11kW3.99 4.07 4.20 4.33 4.29 4.38 4.52 4.66 4.56 4.65 4.80 4.96 4.794.895.05 5.22 4.99 5.10 5.26 5.44 5.16 5.27 5.44 5.63Amps 15.015.315.8 16.4 16.2 16.6 17.2 17.8 17.6 18.1 18.7 19.4 18.919.320.0 20.8 20.1 20.6 21.3 22.1 21.3 21.8 22.6 23.5HI PR 238 256 271 282 267 288 304 317 304 327 346 360 346373394 411 390 419 443 462 431 463 489 510LO PR 106 112 123 131 112 119 130 138 116 123 135 144 122130142 151 128 136 148 158 132 141 153 1632000MBh 56.8 58.5 63.3 67.9 55.5 57.1 61.8 66.4 54.2 55.8 60.4 64.8 52.854.458.9 63.2 50.2 51.7 55.9 60.0 46.5 47.9 51.8 55.6S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.59 0.38 0.910.810.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41∆T22 20 16 11 22 20 16 11 22 20 16 11 222017 11 22 20 16 11 20 19 15 11kW4.02 4.11 4.23 4.37 4.33 4.42 4.56 4.70 4.59 4.69 4.84 5.00 4.834.935.09 5.26 5.03 5.14 5.31 5.48 5.20 5.32 5.49 5.67Amps 15.1 15.5 16.0 16.6 16.4 16.8 17.3 18.0 17.8 18.2 18.8 19.6 19.019.520.2 20.9 20.3 20.8 21.5 22.3 21.5 22.0 22.8 23.7HI PR 241 259 274 285 270 291 307 320 307 331 349 364 350376398 415 394 424 447 466 435 468 494 515LO PR 107 114 124 132 113 120 131 139 117 125 136 145 123131143 152 129 137 150 160 133 142 155 165IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects ACCA (TVA) conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS SS-GSX13 www.goodmanmfg.com 19 eXpAnded CoolinG dAtA — GSX130601B* / CA*f4961*6A* (Cont.)Outdoor Ambient Temperature65ºF75ºF85ºF95ºF105ºF115ºFEntering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71801500MBh 51.8 52.9 56.6 60.5 50.6 51.7 55.2 59.1 49.4 50.5 53.9 57.6 48.2 49.2 52.6 56.2 45.8 46.8 50.0 53.4 42.4 43.3 46.3 49.5S/T 0.83 0.78 0.64 0.48 0.86 0.81 0.66 0.49 0.89 0.83 0.68 0.51 0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.96 0.90 0.73 0.55∆T26 25 22 18 27 26 22 18 27 26 22 18 27 26 23 18 27 26 22 18 25 24 21 17kW3.93 4.01 4.13 4.26 4.22 4.31 4.45 4.59 4.48 4.58 4.72 4.88 4.71 4.81 4.97 5.13 4.90 5.01 5.17 5.34 5.07 5.18 5.35 5.53Amps 14.7 15.1 15.6 16.1 15.9 16.3 16.8 17.5 17.3 17.7 18.3 19.0 18.5 19.0 19.6 20.4 19.7 20.2 20.9 21.7 20.9 21.4 22.2 23.0HI PR 234 251 265 277 262 282 298 311 298 321 339 353 339 365 386 402 382 411 434 453 422 454 479 500LO PR 104 110 120 128 109 116 127 135 114 121 132 141 119 127 139 148 125 133 145 155 129 138 150 1601750MBh 56.1 57.4 61.3 65.5 54.8 56.0 59.9 64.0 53.5 54.7 58.4 62.5 52.2 53.457.060.9 49.6 50.7 54.2 57.9 45.9 46.9 50.2 53.6S/T 0.86 0.81 0.66 0.49 0.90 0.84 0.68 0.51 0.92 0.86 0.70 0.52 0.95 0.890.720.54 0.98 0.92 0.75 0.56 0.99 0.93 0.76 0.57∆T25 24 21 17 26 25 22 17 26 25 22 17 26 252217 26 25 21 17 24 23 20 16kW4.02 4.11 4.23 4.37 4.33 4.42 4.56 4.70 4.59 4.69 4.84 5.00 4.83 4.935.095.26 5.03 5.14 5.31 5.48 5.20 5.32 5.49 5.67Amps 15.1 15.5 16.0 16.6 16.4 16.8 17.3 18.0 17.8 18.2 18.8 19.6 19.0 19.520.220.9 20.3 20.8 21.5 22.3 21.5 22.0 22.8 23.7HI PR 241 259 274 285 270 291 307 320 307 331 349 364 350 377398415 394 424 447 467 435 468 494 515LO PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131143152 129 137 150 160 133 142 155 1652000MBh 57.8 59.1 63.1 67.5 56.5 57.7 61.6 65.9 55.1 56.3 60.264.3 53.8 55.0 58.7 62.8 51.1 52.2 55.8 59.6 47.3 48.4 51.7 55.2S/T 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.96 0.90 0.74 0.55 1.00 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 1.00 0.79 0.59∆T24 23 20 16 24 23 20 16 24 23 20 16 25 24 20 16 23 23 20 16 22 22 19 15kW4.05 4.14 4.27 4.40 4.36 4.45 4.59 4.74 4.63 4.73 4.88 5.04 4.87 4.97 5.13 5.30 5.07 5.18 5.35 5.53 5.24 5.36 5.54 5.72Amps 15.215.616.1 16.7 16.5 16.9 17.5 18.1 18.0 18.4 19.0 19.8 19.2 19.7 20.4 21.1 20.5 21.0 21.7 22.5 21.7 22.3 23.0 23.9HI PR 243 262 276 288 273 294 310 323 310 334 353 368 353 380 402 419 398 428 452 471 439 473 499 521LO PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167851500MBh 52.7 53.7 56.3 60.0 51.5 52.5 55.0 58.6 50.3 51.2 53.7 57.2 49.0 50.0 52.3 55.8 46.6 47.5 49.7 53.1 43.1 44.0 46.1 49.1S/T 0.87 0.84 0.76 0.62 0.91 0.87 0.79 0.64 0.93 0.90 0.81 0.66 0.96 0.93 0.83 0.68 1.00 0.96 0.87 0.70 1.00 0.97 0.87 0.71∆T28 28 26 23 29 28 27 23 29 28 27 23 29 28 27 23 28 28 26 23 26 26 25 21kW3.96 4.04 4.17 4.30 4.26 4.35 4.48 4.62 4.52 4.61 4.76 4.92 4.75 4.85 5.01 5.17 4.94 5.05 5.22 5.39 5.11 5.23 5.40 5.58Amps 14.8 15.2 15.7 16.3 16.0 16.4 17.0 17.6 17.5 17.9 18.5 19.2 18.7 19.1 19.8 20.5 19.9 20.4 21.1 21.9 21.1 21.6 22.4 23.2HI PR 236 254 268 280 265 285 301 314 301 324 342 357 343 369 390 406 386 415 438 457 426 459 484 505LO PR 105 111 121 129 110 118 128 137 115 122 133 142 121 128 140 149 126 134 147 156 131 139 152 1621750MBh 57.1 58.2 61.0 65.0 55.8 56.9 59.6 63.5 54.5 55.5 58.1 62.0 53.1 54.2 56.7 60.5 50.5 51.4 53.9 57.5 46.7 47.7 49.9 53.2S/T 0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.87 0.70 1.00 1.00 0.90 0.73 1.00 1.00 0.91 0.74∆T27 27 25 22 28 27 26 2228 27 26 22 28 27 26 22 27 27 25 22 25 25 24 21kW4.05 4.14 4.27 4.40 4.36 4.45 4.59 4.74 4.63 4.73 4.88 5.04 4.87 4.97 5.13 5.30 5.07 5.18 5.35 5.53 5.24 5.36 5.54 5.72Amps 15.215.616.1 16.7 16.5 16.9 17.5 18.1 18.0 18.4 19.0 19.8 19.2 19.7 20.4 21.1 20.5 21.0 21.7 22.5 21.7 22.3 23.0 23.9HI PR 243 262 276 288 273 294 310 323 310 334 353 368 353 380 402 419 398 428 452 471 439 473 499 521LO PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 1672000MBh 58.8 60.0 62.8 67.0 57.5 58.6 61.3 65.4 56.1 57.2 59.9 63.9 54.7 55.8 58.4 62.3 52.0 53.0 55.5 59.2 48.2 49.1 51.4 54.8S/T 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77∆T26 25 24 21 26 26 24 21 26 26 24 21 25 26 24 21 24 24 24 21 22 23 22 19kW4.09 4.17 4.30 4.44 4.39 4.49 4.63 4.78 4.67 4.77 4.92 5.08 4.91 5.01 5.18 5.35 5.11 5.22 5.39 5.57 5.29 5.40 5.58 5.77Amps 15.4 15.8 16.3 16.9 16.7 17.1 17.6 18.3 18.1 18.6 19.2 19.9 19.4 19.9 20.6 21.3 20.7 21.2 21.9 22.7 21.9 22.5 23.2 24.1HI PR 246 264 279 291 276 297 313 327 313 337 356 371 357 384 406 423 402 432 456 476 444 477 504 526LO PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects AHRI conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS 20 www.goodmanmfg.com SS-GSX13 eXpAnded CoolinG dAtA — GSX130611*/CA*f4961*6d*+eep Outdoor Ambient Temperature65758595105115Entering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71701500MBh 53.8 55.7 61.0 - 52.5 54.4 59.6 - 51.3 53.1 58.2 - 50.0 51.8 56.8 - 47.5 49.2 53.9 - 44.0 45.6 50.0 -S/T 0.66 0.55 0.38 - 0.68 0.57 0.39 - 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.75 0.62 0.43 - 0.75 0.63 0.44 -∆T22 19 14 - 22 19 14 - 22 19 14 - 22 19 14 - 22 19 14 - 20 18 13 -kW3.97 4.05 4.18 - 4.27 4.37 4.51 - 4.54 4.64 4.80 - 4.78 4.89 5.05 - 4.99 5.10 5.27 - 5.16 5.28 5.45 -Amps 15.4 15.8 16.3 - 16.7 17.1 17.6 - 18.1 18.6 19.2 - 19.4 19.9 20.6 - 20.7 21.2 21.9 - 22.0 22.5 23.3 -HI PR 228 245 259 - 256 275 291 - 291 313 331 - 331 357 377 - 373 401 424 - 412 443 468 -LO PR 98 104 114 - 103 110 120 - 107 114 125 - 113 120 131 - 118 126 137 - 122 130 142 -1750MBh 55.4 57.4 62.9 - 54.1 56.1 61.4 - 52.8 54.7 59.9 - 51.5 53.4 58.5 - 48.9 50.7 55.6 - 45.3 47.0 51.5 -S/T 0.69 0.57 0.40 - 0.71 0.60 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.79 0.66 0.46 -∆T20 17 13 - 20 18 13 - 20 18 13 - 20 18 13 - 20 17 13 - 19 16 12 -kW4.00 4.09 4.21 - 4.31 4.40 4.54 - 4.58 4.68 4.84 - 4.82 4.93 5.09 - 5.03 5.14 5.31 - 5.20 5.32 5.50 -Amps 15.5 15.9 16.4 - 16.8 17.2 17.8 - 18.3 18.8 19.4 - 19.6 20.1 20.8 - 20.9 21.4 22.2 - 22.2 22.7 23.5 -HI PR 230 248 262 - 258 278 294 - 294 316 334 - 335 360 380 - 377 405 428 - 416 448 473 -LO PR 99 105 115 - 104 111 121 - 108 115 126 - 114 121 132 - 119 127 139 - 124 131 143 -2000MBh 55.6 57.7 63.2 - 54.3 56.3 61.7 - 53.0 55.0 60.2- 51.8 53.6 58.8 - 49.2 51.0 55.8 - 45.5 47.2 51.7 -S/T 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.80 0.67 0.46 -∆T18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -kW4.03 4.12 4.25 - 4.34 4.44 4.58 - 4.62 4.72 4.88 - 4.86 4.97 5.13 - 5.07 5.18 5.36 - 5.25 5.37 5.55 -Amps 15.716.016.6 - 17.0 17.4 18.0 - 18.5 18.9 19.6 - 19.8 20.3 21.0 - 21.1 21.6 22.4 - 22.4 22.9 23.7 -HI PR 233 250 264 - 261 281 297 - 297 319 337 - 338 364 384 - 380 409 432 - 420 452 477 -LO PR 100 106 116 - 105 112 122 - 110 117 127 - 115 122 134 - 121 128 140 - 125 133 145 -751500MBh 54.7 56.3 60.9 65.4 53.4 55.0 59.5 63.9 52.1 53.7 58.1 62.3 50.952.456.7 60.8 48.3 49.7 53.8 57.8 44.7 46.1 49.9 53.5S/T 0.75 0.67 0.50 0.32 0.77 0.69 0.52 0.34 0.79 0.71 0.54 0.35 0.820.730.55 0.36 0.85 0.76 0.57 0.37 0.86 0.77 0.58 0.37∆T25 23 19 13 25 23 19 13 25 23 19 13 262319 13 25 23 19 13 23 22 18 12kW4.00 4.09 4.22 4.35 4.31 4.40 4.55 4.69 4.58 4.68 4.84 5.00 4.824.935.09 5.26 5.03 5.14 5.31 5.49 5.20 5.32 5.50 5.69Amps 15.5 15.9 16.4 17.1 16.8 17.2 17.8 18.5 18.3 18.8 19.4 20.2 19.620.120.8 21.6 20.9 21.4 22.2 23.0 22.2 22.7 23.5 24.4HI PR 230 248 262 273 258 278 294 306 294 316 334 348 335360380 397 377 405 428 446 416 448 473 493LO PR 99 105 115 122 104 111 121 129 108 115 126 134 114121132 141 119 127 139 148 124 131 143 1531750MBh 56.3 58.0 62.7 67.3 55.0 56.6 61.3 65.8 53.7 55.3 59.8 64.2 52.453.958.4 62.6 49.8 51.2 55.5 59.5 46.1 47.5 51.4 55.1S/T 0.78 0.70 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.860.770.58 0.37 0.89 0.80 0.60 0.39 0.90 0.80 0.61 0.39∆T23 21 17 12 23 22 18 1223 22 18 12 242218 12 23 21 18 12 22 20 16 11kW4.03 4.12 4.25 4.39 4.34 4.44 4.58 4.73 4.62 4.72 4.88 5.04 4.864.975.14 5.31 5.07 5.18 5.36 5.54 5.25 5.37 5.55 5.74Amps 15.716.116.6 17.2 17.0 17.4 18.0 18.7 18.5 18.9 19.6 20.3 19.820.321.0 21.8 21.1 21.6 22.4 23.2 22.4 22.9 23.7 24.7HI PR 233 250 264 276 261 281 297 309 297 320 337 352 338364384 401 380 409 432 451 420 452 478 498LO PR 100 106 116 123 105 112 122 130 110 117 127 136 115122134 142 121 128 140 149 125 133 145 1542000MBh 56.6 58.3 63.1 67.7 55.3 56.9 61.6 66.1 53.9 55.5 60.1 64.5 52.654.258.7 63.0 50.0 51.5 55.7 59.8 46.3 47.7 51.6 55.4S/T 0.79 0.71 0.54 0.35 0.82 0.73 0.56 0.36 0.84 0.75 0.57 0.37 0.870.780.59 0.38 0.90 0.81 0.61 0.39 0.91 0.81 0.62 0.40∆T21 19 16 11 21 19 16 11 21 19 16 11 211916 11 21 19 16 11 19 18 15 10kW4.06 4.15 4.28 4.42 4.38 4.48 4.62 4.77 4.66 4.76 4.92 5.08 4.905.015.18 5.35 5.11 5.23 5.40 5.59 5.29 5.41 5.59 5.78Amps 15.8 16.2 16.7 17.4 17.1 17.6 18.1 18.8 18.7 19.1 19.8 20.5 20.020.521.2 22.0 21.3 21.8 22.6 23.5 22.6 23.2 24.0 24.9HI PR 235 253 267 278 264 284 300 312 300 323 341 355 341367388 405 384 413 437 455 424 457 482 503LO PR 101 107 117 125 106 113 124 132 111 118 129 137 116124135 144 122 130 141 151 126 134 146 156IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects ACCA (TVA) conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS SS-GSX13 www.goodmanmfg.com 21 eXpAnded CoolinG dAtA — GSX130611*/CA*f4961*6d*+eep (Cont.)Outdoor Ambient Temperature65758595105115Entering Indoor Wet Bulb TemperatureIDB Airflow59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71801500MBh 55.6 56.9 60.7 64.9 54.3 55.5 59.3 63.4 53.0 54.2 57.9 61.9 51.8 52.956.560.4 49.2 50.2 53.7 57.4 45.5 46.5 49.7 53.2S/T 0.82 0.77 0.62 0.47 0.85 0.80 0.65 0.48 0.87 0.82 0.66 0.50 0.90 0.840.690.51 0.93 0.87 0.71 0.53 0.94 0.88 0.72 0.54∆T28 27 23 19 28 27 24 19 28 27 24 19 28 272419 28 27 23 19 26 25 22 17kW4.03 4.12 4.25 4.39 4.35 4.44 4.58 4.73 4.62 4.72 4.88 5.04 4.86 4.975.145.31 5.07 5.18 5.36 5.54 5.25 5.37 5.55 5.74Amps 15.7 16.1 16.6 17.2 17.0 17.4 18.0 18.7 18.5 18.9 19.6 20.3 19.8 20.321.021.8 21.1 21.6 22.4 23.2 22.4 22.9 23.7 24.7HI PR 233 250 264 276 261 281 297 309 297 320 337 352 338 364384401 380 409 432 451 420 452 478 498LO PR 100 106 116 123 105 112 122 130 110 117 127 136 115 122134142 121 128 140 149 125 133 145 1541750MBh 57.3 58.6 62.6 66.9 56.0 57.2 61.1 65.3 54.6 55.8 59.6 63.8 53.3 54.5 58.2 62.2 50.6 51.7 55.3 59.1 46.9 47.9 51.2 54.7S/T 0.86 0.80 0.65 0.49 0.89 0.83 0.68 0.51 0.91 0.85 0.70 0.52 0.94 0.88 0.72 0.54 1.00 0.92 0.75 0.56 1.00 0.92 0.75 0.56∆T26 25 22 17 26 25 22 17 26 25 22 17 26 25 22 18 27 25 22 17 25 23 20 16kW4.07 4.15 4.28 4.42 4.38 4.48 4.62 4.77 4.66 4.76 4.92 5.08 4.90 5.01 5.18 5.35 5.11 5.23 5.40 5.59 5.29 5.41 5.59 5.79Amps 15.8 16.2 16.7 17.4 17.1 17.6 18.2 18.9 18.7 19.1 19.8 20.5 20.0 20.5 21.2 22.0 21.3 21.8 22.6 23.5 22.6 23.2 24.0 24.9HI PR 235 253 267 279 264 284 300 313 300 323 341 355 342 368 388 405 384 414 437 455 425 457 482 503LO PR 101 107 117 125 107 113 124 132 111 118 129 137 116 124 135 144 122 130 142 151 126 134 146 1562000MBh 57.6 58.8 62.9 67.2 56.2 57.5 61.4 65.6 54.9 56.1 59.964.1 53.6 54.7 58.5 62.5 50.9 52.0 55.6 59.4 47.1 48.2 51.5 55.0S/T 0.87 0.82 0.66 0.50 0.90 0.85 0.69 0.51 0.92 0.87 0.71 0.53 0.95 0.89 0.73 0.54 1.00 0.93 0.76 0.56 1.00 0.94 0.76 0.57∆T23 22 19 15 23 22 19 16 23 22 19 16 23 23 20 16 23 22 19 15 22 21 18 14kW4.10 4.19 4.32 4.46 4.42 4.51 4.66 4.81 4.70 4.80 4.96 5.12 4.94 5.06 5.22 5.40 5.16 5.27 5.45 5.63 5.34 5.46 5.64 5.84Amps 16.016.416.9 17.6 17.3 17.7 18.3 19.0 18.8 19.3 20.0 20.7 20.2 20.7 21.4 22.2 21.5 22.0 22.8 23.7 22.8 23.4 24.2 25.1HI PR 237 255 270 281 266 287 303 316 303 326 344 359 345 371 392 409 388 418 441 460 429 461 487 508LO PR 102 108 118 126 108 114 125 133 112 119 130 138 117 125 136 145 123 131 143 152 127 135 148 157851500MBh 56.6 57.7 60.4 64.5 55.3 56.4 59.0 63.0 54.0 55.0 57.6 61.5 52.7 53.7 56.2 60.0 50.0 51.0 53.4 57.0 46.3 47.2 49.5 52.8S/T 0.86 0.83 0.75 0.61 0.89 0.86 0.77 0.63 0.91 0.88 0.79 0.64 0.94 0.91 0.82 0.66 0.98 0.94 0.85 0.69 0.98 0.95 0.86 0.70∆T30 29 28 24 30 30 28 24 30 30 28 24 30 30 28 24 30 29 28 24 28 28 26 23kW4.07 4.15 4.28 4.42 4.38 4.48 4.62 4.77 4.66 4.76 4.92 5.08 4.90 5.01 5.18 5.35 5.11 5.23 5.40 5.59 5.29 5.41 5.59 5.79Amps 15.8 16.2 16.7 17.4 17.1 17.6 18.2 18.9 18.7 19.1 19.8 20.5 20.0 20.5 21.2 22.0 21.3 21.8 22.6 23.5 22.6 23.2 24.0 24.9HI PR 235 253 267 279 264 284 300 313 300 323 341 355 342 368 388 405 384 414 437 455 425 457 482 503LO PR 101 107 117 125 107 113 124 132 111 118 129 137 116 124 135 144 122 130 142 151 126 134 146 1561750MBh 58.3 59.4 62.2 66.4 56.9 58.1 60.8 64.9 55.6 56.7 59.4 63.3 54.2 55.3 57.9 61.8 51.5 52.5 55.0 58.7 47.7 48.7 51.0 54.4S/T 0.90 0.87 0.78 0.64 0.93 0.90 0.81 0.66 0.96 0.92 0.83 0.68 0.99 0.95 0.86 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.90 0.73∆T28 27 26 22 28 27 26 2228 27 26 22 28 28 26 23 27 27 26 22 25 25 24 21kW4.10 4.19 4.32 4.46 4.42 4.51 4.66 4.81 4.70 4.80 4.96 5.12 4.95 5.06 5.22 5.40 5.16 5.27 5.45 5.63 5.34 5.46 5.64 5.84Amps 16.016.416.9 17.6 17.3 17.7 18.3 19.0 18.8 19.3 20.0 20.7 20.2 20.7 21.4 22.2 21.5 22.0 22.8 23.7 22.8 23.4 24.2 25.1HI PR 237 255 270 281 266 287 303 316 303 326 344 359 345 371 392 409 388 418 441 460 429 461 487 508LO PR 102 108 118 126 108 114 125 133 112 119 130 138 117 125 136 145 123 131 143 152 127 135 148 1572000MBh 58.6 59.7 62.5 66.7 57.2 58.3 61.1 65.2 55.9 56.9 59.6 63.6 54.5 55.6 58.2 62.1 51.8 52.8 55.3 59.0 48.0 48.9 51.2 54.6S/T 0.91 0.88 0.79 0.64 0.94 0.91 0.82 0.67 0.97 0.93 0.84 0.68 1.00 0.96 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.91 0.74∆T25 24 23 20 25 24 23 20 25 24 23 20 25 25 23 20 24 24 23 20 22 22 21 19kW4.13 4.22 4.35 4.50 4.45 4.55 4.70 4.85 4.74 4.84 5.00 5.17 4.99 5.10 5.27 5.45 5.20 5.32 5.49 5.68 5.38 5.50 5.69 5.89Amps 16.1 16.5 17.1 17.7 17.5 17.9 18.5 19.2 19.0 19.5 20.1 20.9 20.4 20.9 21.6 22.4 21.7 22.2 23.0 23.9 23.0 23.6 24.4 25.4HI PR 240 258 272 284 269 289 306 319 306 329 348 363 348 375 396 413 392 422 445 465 433 466 492 513LO PR 103 109 119 127 109 116 126 134 113 120 131 140 119 126 138 147 124 132 144 154 129 137 149 159IDB: Entering Indoor Dry Bulb TemperatureShaded area reflects AHRI conditionsAmps = outdoor unit amps (comp.+fan)High and low pressures are measured at the liquid and suction service valves.kW = Total system power Product SPecificationS 22 www.goodmanmfg.com SS-GSX13 Ahri rAtinGS See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0181E* ACNF18XX16D*16,800 12,800 13.00 10.80 600 5039733 ACNF24XX16D*17,000 13,000 13.00 10.80 600 5039734 ARPT18B14A*17,400 13,300 13.00 11.00 600 5360106 ARPT24B14A*17,200 13,100 13.00 11.00 600 5378531 ARUF18B14A*17,200 13,100 13.00 11.00 600 5360107 ARUF18B14A*+TXV 17,200 13,100 13.00 11.00 600 5378529 ARUF24B14B*17,200 13,100 13.00 11.00 600 5647167 ARUF24B14B*+TXV 17,200 13,100 13.50 11.00 600 5647168 ASPT24B14A*17,600 13,400 14.00 12.00 605 5722521 ASPT30C14A*18,000 13,700 14.50 12.50 580 5722522 ASUF29B14A*17,600 13,400 13.50 11.50 605 5722520 ASUF29B14A*+TXV 17,600 13,400 14.00 12.00 605 5722563 AVPTC24B14A*17,600 13,400 14.00 12.00 600 5924342 AVPTC30C14A*18,000 13,700 14.50 12.00 615 5924442 AWUF18XX16B*17,200 13,100 13.00 11.00 600 5039739 AWUF31XX16A*17,200 13,100 14.00 11.30 600 5039740 CA*F1824*6D*A*VC80604B*B* 18,000 13,700 14.00 11.50 675 5039742 CA*F1824*6D*G*E80603B*B* 17,800 13,600 14.00 11.50 640 5039744 CA*F1824*6D*G*VC80604B*B* 18,000 13,700 14.00 11.50 670 5039746 CA*F1824*6D*G*VC950453BXB* 17,800 13,600 14.00 11.50 640 5620941 CA*F1824*6D*G*VC950704CXB* 17,800 13,600 14.00 11.50 640 5620944 CA*F1824*6D*G*VM960603BXB* 18,000 13,700 14.00 11.50 670 5620945 CA*F1824*6D*A*VC950453BXB* 18,000 13,700 14.00 11.60 600 6497529 CA*F1824*6D*A*VM960603BXB* 18,000 13,700 14.00 11.60 600 6497530 CA*F1824*6D*GME950403BXA* 18,000 13,700 14.00 11.60 600 6497531 CA*F1824*6D*A*EH800603B*A* 17,800 13,600 14.00 11.50 640 6944831 CA*F1824*6D*AMEH960403BXA* 18,000 13,700 14.00 11.60 600 6944834 CA*F1824*6D*+EEP 17,800 13,600 13.00 11.00 650 5039750 CA*F1824*6D*+MBVC1200**-1A*18,200 13,900 14.00 11.50 640 5039751 CA*F3030*6D*+EEP 18,000 13,700 13.00 11.00 650 5561904 CA*F3030*6D*+EEP+TXV 18,000 13,700 13.00 11.00 650 5581977 CA*F3131*6D*+EEP 18,000 13,700 13.00 11.00 650 5561905 CA*F3131*6D*+EEP+TXV 18,000 13,700 13.00 11.00 650 5561906 CAPT3131*4A*A*VC80604B*B* 18,000 13,700 14.00 11.50 675 5948598 CAPT3131*4A*A*VC950453BXB* 18,000 13,700 14.00 11.50 650 5948600 CAPT3131*4A*A*VC950704CXB* 18,000 13,700 14.00 11.50 660 5948602 CAPT3131*4A*A*VC950714CXB* 18,000 13,700 14.00 11.50 650 5948604 CAPT3131*4A*A*VM960603BXB* 18,000 13,700 14.00 11.50 650 5948606 CAPT3131*4A*A*VM960604CXB* 18,000 13,700 14.00 11.50 670 5948608 CAPT3131*4A*ADVC80603B*B* 18,000 13,700 14.00 11.50 675 5948610 CAPT3131*4A*G*E80603B*B* 18,000 13,700 14.00 11.50 650 5948612 CAPT3131*4A*G*VC80604B*B* 18,000 13,700 14.00 11.50 675 5948614 CAPT3131*4A*G*VC950453BXB* 18,000 13,700 14.00 11.50 650 5948616 CAPT3131*4A*G*VC950704CXB* 18,000 13,700 14.00 11.50 660 5948618 CAPT3131*4A*G*VC950714CXB* 18,000 13,700 14.00 11.50 650 5948620 CAPT3131*4A*G*VM960603BXB* 18,000 13,700 14.00 11.50 650 5948622 CAPT3131*4A*G*VM960604CXB* 18,000 13,700 14.00 11.50 670 5948624 CAPT3131*4A*GME950403BXA* 18,000 13,700 14.00 11.50 575 5948626 CAPT3131*4A*GME950603BXA* 18,000 13,700 14.00 11.50 575 5948628 CAPT3131*4A*A*EH800603B*A* 18,000 13,700 14.00 11.50 650 6944836 CAPT3131*4A*AMEH960403BXA* 18,000 13,700 14.00 11.50 575 6944839 CAPT3131*4A*AMEH960603BXA*18,000 13,700 14.00 11.50 575 6944842 CAPT3131*4A*+EEP 17,400 13,300 13.00 11.00 650 5611304 Product SPecificationS SS-GSX13 www.goodmanmfg.com 23 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0181E* (cont.) CAPT3131*4A*+MBVC1200**-1A*17,400 13,300 14.00 11.50 650 5611305 CHPF1824A6C*+EEP 17,800 13,600 13.00 11.00 650 5039752 CHPF2430B6C*G*E80603B*B* 18,000 13,700 14.00 11.50 640 5039754 CHPF2430B6C*A*VC80604B*B* 17,700 13,500 14.00 11.50 660 5039796 CHPF2430B6C*G*VC80604B*B* 17,700 13,500 14.00 11.50 660 5039798 CHPF2430B6C*G*VC950453BXB* 18,200 13,900 14.00 11.50 650 5620942 CHPF2430B6C*G*VM960603BXB* 18,200 13,900 14.00 11.50 675 5620946 CHPF2430B6C*A*VC950453BXB* 18,400 14,000 14.00 11.60 600 6497532 CHPF2430B6C*A*VM960603BXB* 18,400 14,000 14.00 11.60 600 6497533 CHPF2430B6C*GME950403BXA* 18,400 14,000 14.00 11.60 600 6497534 CHPF2430B6C*A*EH800603B*A* 18,000 13,700 14.00 11.50 640 6944845 CHPF2430B6C*AMEH960403BXA* 18,400 14,000 14.00 11.60 600 6944848 CHPF2430B6C*+EEP 17,800 13,600 13.00 11.00 650 5039758 CHPF2430B6C*+MBVC1200**-1A*18,200 13,900 14.00 11.50 650 5039759 CSCF1824N6D*G*E80603B*B* 18,000 13,700 14.00 11.50 640 5039760 CSCF1824N6D*A*VC80604B*B* 17,700 13,500 14.00 11.50 660 5039800 CSCF1824N6D*G*VC80604B*B* 17,700 13,500 14.00 11.50 660 5039801 CSCF1824N6D*G*VC950453BXB* 18,200 13,900 14.00 11.50 650 5620943 CSCF1824N6D*G*VM960603BXB* 18,200 13,900 14.00 11.50 670 5620947 CSCF1824N6D*A*VC950453BXB* 18,000 13,700 14.00 11.60 650 6497535 CSCF1824N6D*A*EH800603B*A* 18,000 13,700 14.00 11.50 640 6944850 CSCF1824N6D*+EEP 17,800 13,600 13.00 11.00 650 5039763 GSX13 0241D* ACNF24XX16D*22,400 16,500 13.00 11.00 770 4699979 ACNF30XX16D*22,600 16,600 13.00 11.00 845 5624657 ARPT24B14A*22,400 16,500 13.00 11.00 800 5360108 ARUF24B14B*22,000 16,200 13.00 11.00 800 5647169 ARUF24B14B*+TXV 22,000 16,200 13.00 11.00 800 5647170 ASPT24B14A*23,000 16,900 13.80 11.80 810 5722527 ASPT30C14A*23,400 17,200 14.00 12.00 845 5722528 ASUF29B14A*23,000 16,900 13.50 11.50 810 5722526 ASUF29B14A*+TXV 23,000 16,900 13.80 11.80 810 5722565 AVPTC24B14A*22,600 16,600 14.00 12.00 800 5924453 AVPTC30C14A*23,400 17,200 14.00 12.00 780 5924454 AWUF24XX16B*23,000 16,900 13.00 11.00 800 4699990 AWUF30XX16B*23,200 17,100 13.00 11.00 800 4699991 AWUF31XX16A*23,000 16,900 14.00 11.30 800 4699992 AWUF32XX16A*23,000 16,900 14.00 11.30 800 4699993 CA*F1824*6D*G*E80603B*B* 23,000 16,900 14.00 11.50 860 5038902 CA*F1824*6D*G*VC950453BXB* 23,000 16,900 14.00 11.50 800 5620948 CA*F1824*6D*G*VC950704CXB* 23,000 16,900 14.00 11.50 800 5620950 CA*F1824*6D*G*VM960603BXB* 23,000 16,900 14.00 11.50 800 5620951 CA*F1824*6D*A*VC80604B*B* 23,000 16,900 14.00 11.60 820 6497536 CA*F1824*6D*A*VC950453BXB* 23,000 16,900 14.00 11.60 800 6497537 CA*F1824*6D*A*VC950704CXB* 23,000 16,900 14.00 11.60 800 6497538 CA*F1824*6D*A*VM960603BXB* 23,000 16,900 14.00 11.60 800 6497539 CA*F1824*6D*G*VC80604B*B* 23,000 16,900 14.00 11.60 820 6497540 CA*F1824*6D*GME950403BXA* 23,000 16,900 14.00 11.60 800 6497541 CA*F1824*6D*GME950603BXA* 22,800 16,800 13.80 11.50 800 6497542 CA*F1824*6D*A*EH800603B*A* 23,000 16,900 14.00 11.50 860 6944853 CA*F1824*6D*AMEH960403BXA* 23,000 16,900 14.00 11.60 800 6944856 CA*F1824*6D*AMEH960603BXA* 22,800 16,800 13.80 11.50 800 6944858 CA*F1824*6D*+EEP 23,000 16,900 13.00 11.00 800 4700003 CA*F1824*6D*+MBVC1200**-1A*23,000 16,900 14.00 11.50 800 4700004 Product SPecificationS 24 www.goodmanmfg.com SS-GSX13 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0241D* (cont.) CA*F3030*6D*+EEP 23,000 16,900 13.00 11.00 800 5561907 CA*F3030*6D*+EEP+TXV 23,000 16,900 13.00 11.00 800 5581978 CA*F3131*6D*+EEP 23,000 16,900 13.00 11.00 800 5561908 CA*F3131*6D*+EEP+TXV 23,000 16,900 13.00 11.00 800 5561909 CA*F3636*6D*+EEP 23,000 16,900 13.00 11.00 800 5561910 CA*F3636*6D*+EEP+TXV 23,000 16,900 13.00 11.00 800 5561911 CAPT3131*4A*A*VC80604B*B* 23,000 16,900 14.00 11.50 830 5948630 CAPT3131*4A*A*VC950453BXB* 23,000 16,900 14.00 11.50 800 5948632 CAPT3131*4A*A*VC950704CXB* 23,000 16,900 14.00 11.50 800 5948634 CAPT3131*4A*A*VC950714CXB* 23,000 16,900 14.00 11.50 800 5948636 CAPT3131*4A*A*VM960603BXB* 23,000 16,900 14.00 11.50 820 5948638 CAPT3131*4A*A*VM960604CXB* 23,000 16,900 14.00 11.50 800 5948640 CAPT3131*4A*ADVC80603B*B* 23,000 16,900 14.00 11.50 800 5948642 CAPT3131*4A*G*E80603B*B* 23,000 16,900 14.00 11.50 800 5948644 CAPT3131*4A*G*VC80604B*B* 23,000 16,900 14.00 11.50 830 5948646 CAPT3131*4A*G*VC950453BXB* 23,000 16,900 14.00 11.50 800 5948648 CAPT3131*4A*G*VC950704CXB* 23,000 16,900 14.00 11.50 800 5948650 CAPT3131*4A*G*VC950714CXB* 23,000 16,900 14.00 11.50 800 5948652 CAPT3131*4A*G*VM960603BXB* 23,000 16,900 14.00 11.50 820 5948654 CAPT3131*4A*G*VM960604CXB* 23,000 16,900 14.00 11.50 800 5948656 CAPT3131*4A*GME950403BXA* 23,000 16,900 14.00 11.50 800 5948658 CAPT3131*4A*GME950603BXA* 23,000 16,900 14.00 11.50 800 5948660 CAPT3131*4A*A*EH800603B*A* 23,000 16,900 14.00 11.50 800 6944860 CAPT3131*4A*AMEH960403BXA* 23,000 16,900 14.00 11.50 800 6944863 CAPT3131*4A*AMEH960603BXA* 23,000 16,900 14.00 11.50 800 6944866 CAPT3131*4A*+EEP 22,800 16,800 13.00 11.00 800 5611334 CAPT3131*4A*+MBVC1200**-1A*22,800 16,800 14.00 11.50 800 5611335 CHPF1824A6C*+EEP 23,000 16,900 13.00 11.00 800 4700005 CHPF2430B6C*G*E80603B*B* 23,000 16,900 14.00 11.50 860 5039075 CHPF2430B6C*G*VC950453BXB* 23,400 17,200 14.00 11.50 800 5620949 CHPF2430B6C*G*VM960603BXB* 23,400 17,200 14.00 11.50 800 5620952 CHPF2430B6C*A*VC950453BXB* 23,400 17,200 14.00 11.60 800 6497543 CHPF2430B6C*A*VM960603BXB* 23,400 17,200 14.00 11.60 800 6497544 CHPF2430B6C*GME950403BXA* 23,400 17,200 14.00 11.60 800 6497545 CHPF2430B6C*A*EH800603B*A* 23,000 16,900 14.00 11.50 860 6944869 CHPF2430B6C*AMEH960403BXA* 23,400 17,200 14.00 11.60 800 6944872 CHPF2430B6C*+EEP 23,000 16,900 13.00 11.00 800 4700009 CHPF2430B6C*+MBVC1200**-1A*23,400 17,200 14.00 11.50 800 4700010 CSCF1824N6D*A*VC950453BXB* 23,000 16,900 14.00 11.60 800 6497546 CSCF1824N6D*+EEP 23,000 16,900 13.00 11.00 800 6497547 GSX13 0301B* ACNF30XX16D*27,600 20,800 13.00 11.00 890 4689680 ARPT30B14A*27,000 20,400 13.00 11.00 900 5383473 ARUF30B14A*27,000 20,400 13.00 11.00 900 5383471 ARUF30B14A*+TXV 27,000 20,400 13.00 11.00 900 5383474 ARUF36C14B*27,200 20,600 13.00 11.00 1,000 5647171 ARUF36C14B*+TXV 27,200 20,600 13.50 11.50 1,000 5647172 ASPT36C14A*28,000 21,200 14.00 12.00 1,010 5722534 ASUF29B14A*26,000 19,600 13.30 11.30 975 5722732 ASUF39C14A*28,000 21,200 13.50 11.50 1,005 5722532 ASUF39C14A*+TXV 28,000 21,200 14.00 12.00 1,005 5722533 AVPTC36C14A*28,000 21,200 14.00 12.00 1,015 5924443 AWUF30XX16B*27,600 20,800 13.00 11.00 1,000 3287812 AWUF36XX16B*27,800 21,000 13.00 11.00 1,000 3287813 Product SPecificationS SS-GSX13 www.goodmanmfg.com 25 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0301B* (cont.) AWUF37XX16B*28,000 21,200 13.00 11.00 1,000 3287814 CA*F3030*6D*GME950403BXA* 28,400 21,400 14.00 11.50 1,000 4701045 CA*F3030*6D*GME950603BXA* 28,200 21,200 13.50 11.30 1,000 4703492 CA*F3030*6D*G*VC950453BXB* 28,400 21,400 14.00 11.50 1,000 5620953 CA*F3030*6D*G*VC950704CXB* 28,400 21,400 14.00 11.50 1,000 5620957 CA*F3030*6D*A*VC950714CXB* 28,400 21,400 14.00 11.50 1,000 5620959 CA*F3030*6D*G*VC950714CXB* 28,400 21,400 14.00 11.50 1,000 5620960 CA*F3030*6D*G*VM960603BXB* 28,400 21,400 14.00 11.50 1,000 5620963 CA*F3030*6D*A*VM960604CXB* 28,400 21,400 14.00 11.50 1,000 5620966 CA*F3030*6D*G*VM960604CXB* 28,400 21,400 14.00 11.50 1,000 5620967 CA*F3030*6D*A*VC80604B*B* 28,200 21,200 13.50 11.30 1,050 6497548 CA*F3030*6D*A*VC950453BXB* 28,400 21,400 14.00 11.50 1,000 6497549 CA*F3030*6D*A*VC950704CXB* 28,400 21,400 14.00 11.50 1,000 6497550 CA*F3030*6D*A*VM960603BXB* 28,400 21,400 14.00 11.50 1,000 6497551 CA*F3030*6D*ADVC80603B*B* 28,000 21,200 13.50 11.30 1,050 6497552 CA*F3030*6D*G*VC80604B*B* 28,200 21,200 13.50 11.30 1,050 6497553 CA*F3030*6D*AMEH960403BXA* 28,400 21,400 14.00 11.50 1,000 6944873 CA*F3030*6D*AMEH960603BXA* 28,200 21,200 13.50 11.30 1,000 6944874 CA*F3030*6D*+EEP 28,400 21,400 13.00 11.00 1,050 4355516 CA*F3131*6D*GME950403BXA* 28,600 21,600 14.00 11.50 1,000 4701047 CA*F3131*6D*GME950603BXA* 28,400 21,400 13.50 11.30 1,000 4703496 CA*F3131*6D*G*VC950453BXB* 28,600 21,600 14.00 11.50 1,000 5620954 CA*F3131*6D*G*VC950704CXB* 28,400 21,400 14.00 11.50 900 5620958 CA*F3131*6D*A*VC950714CXB* 28,600 21,600 14.00 11.50 1,050 5620961 CA*F3131*6D*G*VC950714CXB* 28,600 21,600 14.00 11.50 1,050 5620962 CA*F3131*6D*G*VM960603BXB* 28,600 21,600 14.00 11.50 1,000 5620964 CA*F3131*6D*A*VM960604CXB* 28,600 21,600 14.00 11.50 1,050 5620968 CA*F3131*6D*G*VM960604CXB* 28,600 21,600 14.00 11.50 1,050 5620969 CA*F3131*6D*A*VC80604B*B* 28,200 21,200 13.50 11.50 1,050 6497554 CA*F3131*6D*A*VC950453BXB* 28,600 21,600 14.00 11.50 1,000 6497555 CA*F3131*6D*A*VC950704CXB* 28,400 21,400 14.00 11.50 900 6497556 CA*F3131*6D*A*VM960603BXB* 28,600 21,600 14.00 11.50 1,000 6497557 CA*F3131*6D*ADVC80603B*B* 28,000 21,200 13.50 11.50 1,050 6497558 CA*F3131*6D*G*VC80604B*B* 28,200 21,200 13.50 11.50 1,050 6497559 CA*F3131*6D*AMEH960403BXA* 28,600 21,600 14.00 11.50 1,000 6944875 CA*F3131*6D*AMEH960603BXA* 28,400 21,400 13.50 11.30 1,000 6944876 CA*F3131*6D*+EEP 28,600 21,600 13.00 11.00 1,050 4385558 CA*F3131*6D*+MBVC1200**-1A*28,400 21,400 14.00 11.50 950 4385559 CA*F3636*6D*+EEP 28,400 21,400 13.00 11.00 1,000 5561912 CA*F3636*6D*+EEP+TXV 28,400 21,400 13.00 11.00 1,000 5561913 CA*F3642*6D*+EEP 28,400 21,400 13.00 11.00 1,000 5561914 CA*F3642*6D*+EEP+TXV 28,400 21,400 13.00 11.00 1,000 5561915 CA*F3743*6D*+EEP 28,400 21,400 13.50 11.00 1,000 5581982 CA*F3743*6D*+EEP+TXV 28,400 21,400 13.50 11.00 1,000 5581983 CAPT3743*4A*A*VC80604B*B* 28,200 21,200 14.00 12.00 1,000 6494146 CAPT3743*4A*A*VC80805C*B* 28,200 21,200 14.00 12.00 980 6494147 CAPT3743*4A*A*VC81005C*B* 28,200 21,200 14.00 12.00 1,000 6494148 CAPT3743*4A*A*VC950453BXB* 28,200 21,200 13.50 11.50 1,000 6494149 CAPT3743*4A*A*VC950704CXB* 28,200 21,200 13.50 11.50 1,020 6494150 CAPT3743*4A*A*VC950714CXB* 28,200 21,200 13.50 11.50 1,050 6494151 CAPT3743*4A*A*VC950905CXB*28,200 21,200 14.00 12.00 985 6494152 CAPT3743*4A*A*VC950905DXB* 28,200 21,200 14.00 12.00 985 6494153 Product SPecificationS 26 www.goodmanmfg.com SS-GSX13 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0301B* (cont.) CAPT3743*4A*A*VC950915DXB* 28,200 21,200 14.00 12.00 1,005 6494154 CAPT3743*4A*A*VC951155DXB* 28,200 21,200 14.00 12.00 1,005 6494155 CAPT3743*4A*A*VM960603BXB* 28,200 21,200 13.50 11.50 1,010 6494156 CAPT3743*4A*A*VM960604CXB* 28,200 21,200 13.50 11.50 1,040 6494157 CAPT3743*4A*A*VM960805CXB* 28,200 21,200 14.00 12.00 985 6494158 CAPT3743*4A*A*VM960805DXB* 28,200 21,200 14.00 12.00 1,000 6494159 CAPT3743*4A*A*VM961005DXB* 28,200 21,200 14.00 12.00 980 6494160 CAPT3743*4A*A*VM961155DXB* 28,200 21,200 14.00 12.00 1,000 6494161 CAPT3743*4A*ADVC80603B*B* 28,000 21,200 13.50 11.50 1,000 6494162 CAPT3743*4A*ADVC80805C*B* 28,000 21,200 14.00 12.00 990 6494163 CAPT3743*4A*ADVC81005C*B* 28,000 21,200 14.00 12.00 1,010 6494164 CAPT3743*4A*G*E80603B*B* 28,200 21,200 13.50 11.50 1,050 6494165 CAPT3743*4A*GME950403BXA* 28,200 21,200 13.50 11.50 1,000 6494166 CAPT3743*4A*GME950603BXA* 28,200 21,200 13.50 11.50 1,000 6494167 CAPT3743*4A*G*VC80604B*B* 28,200 21,200 14.00 12.00 1,000 6494192 CAPT3743*4A*G*VC80805C*B* 28,200 21,200 14.00 12.00 980 6494193 CAPT3743*4A*G*VC81005C*B* 28,200 21,200 14.00 12.00 1,000 6494194 CAPT3743*4A*G*VC950453BXB* 28,200 21,200 13.50 11.50 1,000 6494195 CAPT3743*4A*G*VC950704CXB* 28,200 21,200 13.50 11.50 1,020 6494196 CAPT3743*4A*G*VC950714CXB* 28,200 21,200 13.50 11.50 1,050 6494197 CAPT3743*4A*G*VC950905CXB* 28,200 21,200 14.00 12.00 985 6494198 CAPT3743*4A*G*VC950905DXB* 28,200 21,200 14.00 12.00 985 6494199 CAPT3743*4A*G*VC950915DXB* 28,200 21,200 14.00 12.00 1,005 6494200 CAPT3743*4A*G*VC951155DXB* 28,200 21,200 14.00 12.00 1,005 6494201 CAPT3743*4A*G*VM960603BXB* 28,200 21,200 13.50 11.50 1,010 6494202 CAPT3743*4A*G*VM960604CXB* 28,200 21,200 13.50 11.50 1,040 6494203 CAPT3743*4A*G*VM960805CXB* 28,200 21,200 14.00 12.00 985 6494204 CAPT3743*4A*G*VM960805DXB* 28,200 21,200 14.00 12.00 1,000 6494205 CAPT3743*4A*G*VM961005DXB* 28,200 21,200 14.00 12.00 980 6494206 CAPT3743*4A*G*VM961155DXB* 28,200 21,200 14.00 12.00 1,000 6494207 CAPT3743*4A*A*EH800603B*A* 28,200 21,200 13.50 11.50 1,050 6944877 CAPT3743*4A*AMEH960403BXA* 28,200 21,200 13.50 11.50 1,000 6944879 CAPT3743*4A*AMEH960603BXA* 28,200 21,200 13.50 11.50 1,000 6944881 CAPT3743*4A*+EEP 28,200 21,200 13.00 11.00 1,000 5611306 CAPT3743*4A*+MBVC1200**-1A*28,000 21,200 14.00 11.50 900 6494168 CAPT3743*4A*+MBVC1600**-1A*28,200 21,200 14.00 11.50 1,000 5611307 CHPF2430B6C*GME950403BXA* 28,400 21,400 14.00 11.50 1,000 4701102 CHPF2430B6C*G*VC950453BXB* 28,400 21,400 14.00 11.50 1,000 5620955 CHPF2430B6C*G*VM960603BXB* 28,400 21,400 14.00 11.50 1,000 5620965 CHPF2430B6C*A*VM960604CXB* 28,400 21,400 14.00 11.50 1,000 5620970 CHPF2430B6C*G*VM960604CXB* 28,400 21,400 14.00 11.50 1,000 5620971 CHPF2430B6C*A*VC950453BXB* 28,400 21,400 14.00 11.50 1,000 6497560 CHPF2430B6C*A*VM960603BXB* 28,400 21,400 14.00 11.50 1,000 6497561 CHPF2430B6C*AMEH960403BXA* 28,400 21,400 14.00 11.50 1,000 6944883 CHPF2430B6C*+EEP 28,400 21,400 13.00 11.00 1,050 3299982 CHPF2430B6C*+MBVC1200**-1A*28,400 21,400 14.00 11.50 1,050 3609438 CSCF3036N6D*G*VC950453BXB* 28,400 21,400 14.00 11.30 1,000 5620956 CSCF3036N6D*A*VC950453BXB* 28,400 21,400 14.00 11.30 1,000 6497562 CSCF3036N6D*+EEP 28,400 21,400 13.00 11.00 1,000 4767411 Product SPecificationS SS-GSX13 www.goodmanmfg.com 27 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0361E* ARPT36C14A*33,000 25,800 13.00 11.00 1,150 5696616 ARPT42D14A*34,200 26,600 13.50 11.30 1,150 5696617 ARUF36C14B*33,000 25,800 13.00 11.00 1,000 5696620 ARUF36C14B*+TXV 34,000 26,400 13.00 11.00 1,165 5696621 ARUF42C14A*34,200 26,600 13.00 11.00 1,150 5696622 ARUF42C14A*+TXV 34,200 26,600 13.00 11.00 1,150 5696623 ASPT36C14A*34,000 26,400 13.80 11.80 1,210 5722540 ASPT42D14A*34,600 27,000 14.00 12.00 1,280 5722541 ASUF39C14A*34,000 26,400 13.50 11.50 1,210 5722538 ASUF39C14A*+TXV 34,000 26,400 13.80 11.80 1,210 5722539 AVPTC36C14A*34,000 26,400 13.80 11.80 1,215 5924444 AVPTC42D14A*34,600 27,000 14.00 12.00 1,225 5924445 AWUF36XX16B*33,400 26,000 13.00 11.00 1,150 5696626 AWUF37XX16B*33,600 26,200 13.00 11.00 1,150 5696627 CA*F3636*6D*G*VC950915DXB* 33,600 26,200 13.50 11.30 1,220 5696628 CA*F3636*6D*A*VC950915DXB* 33,600 26,200 13.50 11.30 1,220 5696631 CA*F3636*6D*A*VM960604CXB* 33,600 26,200 13.50 11.30 1,155 5696634 CA*F3636*6D*G*VM960604CXB* 33,600 26,200 13.50 11.30 1,155 5696687 CA*F3636*6D*G*VC950905CXB* 33,600 26,200 13.50 11.30 1,150 5696691 CA*F3636*6D*G*VM960805DXB* 33,600 26,200 13.50 11.30 1,220 5696695 CA*F3636*6D*G*VM961005DXB* 33,600 26,200 13.50 11.30 1,205 5696699 CA*F3636*6D*G*VC950905DXB* 33,600 26,200 13.50 11.30 1,150 5696703 CA*F3636*6D*G*VM960805CXB* 33,600 26,200 13.50 11.30 1,150 5696707 CA*F3636*6D*G*VC950714CXB* 33,600 26,200 13.50 11.30 1,135 5696711 CA*F3636*6D*A*VC950714CXB* 33,600 26,200 13.50 11.30 1,135 5696713 CA*F3636*6D*G*VC951155DXB* 33,600 26,200 13.50 11.30 1,205 5696715 CA*F3636*6D*G*VM961155DXB* 33,600 26,200 13.50 11.30 1,205 5696719 CA*F3636*6D*+EEP 33,600 26,200 13.00 11.00 1,200 5696608 CA*F3642*6D*G*VC950915DXB* 34,000 26,400 14.00 11.50 1,225 5696629 CA*F3642*6D*A*VC950915DXB* 34,000 26,400 14.00 11.50 1,225 5696632 CA*F3642*6D*A*VM960604CXB* 34,000 26,400 14.00 11.50 1,165 5696635 CA*F3642*6D*G*VC950714CXB* 34,000 26,400 14.00 11.50 1,160 5696638 CA*F3642*6D*A*VC950714CXB* 34,000 26,400 14.00 11.50 1,160 5696639 CA*F3642*6D*G*VM960604CXB* 34,000 26,400 14.00 11.50 1,165 5696688 CA*F3642*6D*G*VC950905CXB* 34,000 26,400 14.00 11.50 1,165 5696692 CA*F3642*6D*G*VM960805DXB* 34,000 26,400 14.00 11.50 1,225 5696696 CA*F3642*6D*G*VM961005DXB* 34,000 26,400 14.00 11.50 1,205 5696700 CA*F3642*6D*G*VC950905DXB* 34,000 26,400 14.00 11.50 1,165 5696704 CA*F3642*6D*G*VM960805CXB* 34,000 26,400 14.00 11.50 1,165 5696708 CA*F3642*6D*G*VC951155DXB* 34,000 26,400 14.00 11.50 1,210 5696716 CA*F3642*6D*G*VM961155DXB* 34,000 26,400 14.00 11.50 1,210 5696720 CA*F3642*6D*+EEP 33,600 26,200 13.00 11.00 1,200 5696609 CA*F3642*6D*+MBVC1600**-1A*34,000 26,400 14.00 11.50 1,200 5696640 CA*F3743*6D*G*VC950915DXB* 34,000 26,400 14.00 11.50 1,225 5696630 CA*F3743*6D*A*VC950915DXB* 34,000 26,400 14.00 11.50 1,225 5696633 CA*F3743*6D*A*VM960604CXB* 34,000 26,400 14.00 11.50 1,170 5696636 CA*F3743*6D*G*VM960604CXB* 34,000 26,400 14.00 11.50 1,170 5696689 CA*F3743*6D*G*VC950905CXB* 34,000 26,400 14.00 11.50 1,185 5696693 CA*F3743*6D*G*VM960805DXB* 34,000 26,400 14.00 11.50 1,225 5696697 CA*F3743*6D*G*VM961005DXB* 34,000 26,400 14.00 11.50 1,210 5696701 CA*F3743*6D*G*VC950905DXB*34,000 26,400 14.00 11.50 1,090 5696705 CA*F3743*6D*G*VM960805CXB* 34,000 26,400 14.00 11.50 1,185 5696709 CA*F3743*6D*G*VC950714CXB* 34,000 26,400 14.00 11.50 1,165 5696712 Product SPecificationS 28 www.goodmanmfg.com SS-GSX13 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0361E* (cont.) CA*F3743*6D*A*VC950714CXB* 34,000 26,400 14.00 11.50 1,165 5696714 CA*F3743*6D*G*VC951155DXB* 34,000 26,400 14.00 11.50 1,210 5696717 CA*F3743*6D*G*VM961155DXB* 34,000 26,400 14.00 11.50 1,210 5696721 CA*F3743*6D*+EEP 34,200 26,600 13.00 11.00 1,200 5696610 CA*F3743*6D*+EEP+TXV 34,200 26,600 13.50 11.00 1,200 5696611 CA*F3743*6D*+MBVC1600**-1A*34,000 26,400 14.00 11.50 1,210 5696641 CAPT3743*4A*A*VC80604B*B* 34,000 26,400 13.50 11.50 1,220 6494225 CAPT3743*4A*A*VC80805C*B* 34,000 26,400 13.50 11.50 1,190 6494226 CAPT3743*4A*A*VC81005C*B* 34,000 26,400 13.50 11.50 1,210 6494227 CAPT3743*4A*A*VC950704CXB* 34,000 26,400 13.00 11.00 1,220 6494228 CAPT3743*4A*A*VC950714CXB* 34,000 26,400 13.50 11.50 1,250 6494229 CAPT3743*4A*A*VC950905CXB* 34,000 26,400 13.50 11.50 1,170 6494230 CAPT3743*4A*A*VC950905DXB* 34,000 26,400 13.50 11.50 1,170 6494231 CAPT3743*4A*A*VC950915DXB* 34,000 26,400 13.50 11.50 1,210 6494232 CAPT3743*4A*A*VC951155DXB* 34,000 26,400 13.50 11.50 1,200 6494233 CAPT3743*4A*A*VM960603BXB* 34,000 26,400 13.00 11.00 1,220 6494234 CAPT3743*4A*A*VM960604CXB* 34,000 26,400 13.50 11.50 1,250 6494235 CAPT3743*4A*A*VM960805CXB* 34,000 26,400 13.50 11.50 1,175 6494236 CAPT3743*4A*A*VM960805DXB* 34,000 26,400 13.50 11.50 1,175 6494237 CAPT3743*4A*A*VM961005DXB* 34,000 26,400 13.50 11.50 1,170 6494238 CAPT3743*4A*A*VM961155DXB* 34,000 26,400 13.50 11.50 1,200 6494239 CAPT3743*4A*ADVC80603B*B* 34,000 26,400 13.50 11.50 1,165 6494240 CAPT3743*4A*ADVC80805C*B* 34,000 26,400 13.50 11.50 1,190 6494241 CAPT3743*4A*ADVC81005C*B* 34,000 26,400 13.50 11.50 1,235 6494242 CAPT3743*4A*G*E80603B*B* 34,000 26,400 13.00 11.00 1,150 6494243 CAPT3743*4A*G*E80805C*B* 34,000 26,400 13.50 11.50 1,210 6494244 CAPT3743*4A*G*E81005C*B* 34,000 26,400 13.50 11.50 1,230 6494245 CAPT3743*4A*GME950403BXA* 34,000 26,400 13.00 11.00 1,150 6494246 CAPT3743*4A*GME950603BXA* 33,400 26,000 13.00 11.00 1,100 6494247 CAPT3743*4A*GME950805CXA* 33,400 26,000 13.50 11.50 1,090 6494248 CAPT3743*4A*GME951005DXA* 34,000 26,400 13.50 11.50 1,250 6494249 CAPT3743*4A*G*VC80604B*B* 34,000 26,400 13.50 11.50 1,220 6494277 CAPT3743*4A*G*VC80805C*B* 34,000 26,400 13.50 11.50 1,190 6494278 CAPT3743*4A*G*VC81005C*B* 34,000 26,400 13.50 11.50 1,210 6494279 CAPT3743*4A*G*VC950704CXB* 34,000 26,400 13.00 11.00 1,220 6494280 CAPT3743*4A*G*VC950714CXB* 34,000 26,400 13.50 11.50 1,250 6494281 CAPT3743*4A*G*VC950905CXB* 34,000 26,400 13.50 11.50 1,170 6494282 CAPT3743*4A*G*VC950905DXB* 34,000 26,400 13.50 11.50 1,170 6494283 CAPT3743*4A*G*VC950915DXB* 34,000 26,400 13.50 11.50 1,210 6494284 CAPT3743*4A*G*VC951155DXB* 34,000 26,400 13.50 11.50 1,200 6494285 CAPT3743*4A*G*VM960603BXB* 34,000 26,400 13.00 11.00 1,220 6494286 CAPT3743*4A*G*VM960604CXB* 34,000 26,400 13.50 11.50 1,250 6494287 CAPT3743*4A*G*VM960805CXB* 34,000 26,400 13.50 11.50 1,175 6494288 CAPT3743*4A*G*VM960805DXB* 34,000 26,400 13.50 11.50 1,175 6494289 CAPT3743*4A*G*VM961005DXB* 34,000 26,400 13.50 11.50 1,170 6494290 CAPT3743*4A*G*VM961155DXB* 34,000 26,400 13.50 11.50 1,200 6494291 CAPT3743*4A*A*EH800603B*A* 34,000 26,400 13.00 11.00 1,150 6944884 CAPT3743*4A*A*EH800805C*A* 34,000 26,400 13.50 11.50 1,210 6944886 CAPT3743*4A*A*EH801005C*A*34,000 26,400 13.50 11.50 1,230 6944888 CAPT3743*4A*AMEH960403BXA*34,000 26,400 13.00 11.00 1,150 6944890 CAPT3743*4A*AMEH960603BXA* 33,400 26,000 13.00 11.00 1,100 6944892 CAPT3743*4A*AMEH960805CXA* 33,400 26,000 13.50 11.50 1,090 6944894 CAPT3743*4A*AMEH961005DXA* 34,000 26,400 13.50 11.50 1,250 6944896 Product SPecificationS SS-GSX13 www.goodmanmfg.com 29 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0361E* (cont.) CAPT3743*4A*+EEP 34,000 26,400 13.00 11.00 1,200 5696612 CAPT3743*4A*+MBVC1200**-1A*34,000 26,400 13.00 11.50 1,200 6494250 CAPT3743*4A*+MBVC1600**-1A*34,000 26,400 14.00 11.50 1,205 5696642 CAPT3743*4A*+MBVC2000**-1A*34,000 26,400 14.00 11.50 1,205 5696644 CHPF3636B6C*+EEP 34,000 26,400 13.00 11.00 1,200 5696613 CHPF3642C6C*+EEP 34,000 26,400 13.00 11.00 1,200 5696614 CHPF3642C6C*+MBVC1600**-1A*34,000 26,400 14.00 11.50 1,210 5696643 CHPF3642D6C*A*VM960604CXB* 33,600 26,200 14.00 11.50 1,170 5696637 CHPF3642D6C*G*VM960604CXB* 33,600 26,200 14.00 11.50 1,170 5696690 CHPF3642D6C*G*VC950905CXB* 33,600 26,200 14.00 11.50 1,170 5696694 CHPF3642D6C*G*VM960805DXB* 33,600 26,200 14.00 11.50 1,225 5696698 CHPF3642D6C*G*VM961005DXB* 33,600 26,200 14.00 11.50 1,210 5696702 CHPF3642D6C*G*VC950905DXB* 33,600 26,200 14.00 11.50 1,105 5696706 CHPF3642D6C*G*VM960805CXB* 33,600 26,200 14.00 11.50 1,170 5696710 CHPF3642D6C*G*VC951155DXB* 33,600 26,200 14.00 11.50 1,210 5696718 CHPF3642D6C*G*VM961155DXB* 33,600 26,200 14.00 11.50 1,210 5696722 CHPF3642D6C*+EEP 34,000 26,400 13.00 11.00 1,200 5696615 CSCF3036N6D*+EEP 34,000 26,400 13.00 11.00 1,200 6752560 CSCF3642N6D*+EEP 34,600 27,000 13.00 11.00 1,200 6752561 GSX13 0421B* ARPT42D14A*40,000 30,600 13.00 11.00 1,280 5360115 ARPT48D14A*40,500 31,000 13.50 11.50 1,280 5378541 ARUF42C14A*39,500 30,200 13.00 11.00 1,280 5360116 ARUF42C14A*+TXV 39,500 30,200 13.00 11.00 1,280 5378539 ARUF48D14A*39,500 30,200 13.00 11.00 1,350 5378540 ASPT42D14A*40,500 31,000 14.00 12.00 1,385 5722552 ASUF39C14A*38,500 29,600 13.50 11.50 1,435 5722550 ASUF39C14A*+TXV 38,500 29,600 13.80 11.80 1,435 5722551 ASUF49C14A*39,500 30,200 13.50 11.50 1,310 5620421 ASUF49C14A*+TXV 39,500 30,200 13.80 11.70 1,310 5620404 AVPTC42D14A*40,500 31,000 14.00 12.00 1,495 5924343 CA*F3642*6D*G*E80805C*B* 40,000 30,600 13.00 11.30 1,350 5038971 CA*F3642*6D*A*EH800805C*A* 40,000 30,600 13.00 11.30 1,350 6944898 CA*F3642*6D*+EEP 40,000 30,600 13.00 11.00 1,400 4946292 CA*F3642*6D*+EEP+TXV 40,000 30,600 13.00 11.00 1,400 5561917 CA*F3743*6D*G*E80805C*B* 40,000 30,600 13.00 11.30 1,350 5039232 CA*F3743*6D*A*EH800805C*A* 40,000 30,600 13.00 11.30 1,350 6944900 CA*F3743*6D*+EEP 40,000 30,600 13.00 11.00 1,400 4415025 CA*F4860*6D*GME951005DXA* 40,500 31,000 13.50 11.00 1,440 4703539 CA*F4860*6D*GME950805CXA* 40,500 31,000 14.00 11.30 1,400 4703730 CA*F4860*6D*G*E80805C*B* 41,000 31,400 13.50 11.50 1,510 5039124 CA*F4860*6D*A*VC950714CXB* 41,000 31,400 14.00 11.50 1,400 5621021 CA*F4860*6D*G*VC950714CXB* 41,000 31,400 14.00 11.50 1,400 5621022 CA*F4860*6D*G*VC950905CXB* 41,000 31,400 14.00 11.50 1,400 5621023 CA*F4860*6D*G*VC950905DXB* 41,000 31,400 14.00 11.50 1,400 5621027 CA*F4860*6D*A*VC950915DXB* 41,000 31,400 14.00 11.50 1,400 5621030 CA*F4860*6D*G*VC950915DXB* 41,000 31,400 14.00 11.50 1,400 5621031 CA*F4860*6D*G*VC951155DXB* 41,000 31,400 14.00 11.50 1,400 5621032 CA*F4860*6D*A*VM960604CXB* 41,000 31,400 14.00 11.50 1,400 5621035 CA*F4860*6D*G*VM960604CXB* 41,000 31,400 14.00 11.50 1,400 5621036 CA*F4860*6D*G*VM960805CXB* 41,000 31,400 14.00 11.50 1,400 5621041 CA*F4860*6D*G*VM960805DXB* 41,000 31,400 14.00 11.50 1,400 5621044 CA*F4860*6D*G*VM961005DXB* 41,000 31,400 14.00 11.50 1,400 5621047 CA*F4860*6D*G*VM961155DXB* 41,000 31,400 14.00 11.50 1,400 5621049 Product SPecificationS 30 www.goodmanmfg.com SS-GSX13 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0421B* (cont.) CA*F4860*6D*A*VC950905CXB* 41,000 31,400 14.00 11.50 1,400 6497563 CA*F4860*6D*A*VC950905DXB* 41,000 31,400 14.00 11.50 1,400 6497564 CA*F4860*6D*A*VC951155DXB* 41,000 31,400 14.00 11.50 1,400 6497565 CA*F4860*6D*A*VM960805CXB* 41,000 31,400 14.00 11.50 1,400 6497566 CA*F4860*6D*A*VM960805DXB* 41,000 31,400 14.00 11.50 1,400 6497567 CA*F4860*6D*A*VM961005DXB* 41,000 31,400 14.00 11.50 1,400 6497568 CA*F4860*6D*A*VM961155DXB* 41,000 31,400 14.00 11.50 1,400 6497569 CA*F4860*6D*A*EH800805C*A* 41,000 31,400 13.50 11.50 1,510 6944902 CA*F4860*6D*AMEH960805CXA* 40,500 31,000 14.00 11.30 1,400 6944904 CA*F4860*6D*AMEH961005DXA* 40,500 31,000 13.50 11.00 1,440 6944906 CA*F4860*6D*+EEP 41,000 31,400 13.00 11.00 1,400 3880267 CA*F4860*6D*+MBVC1600**-1A*41,000 31,400 14.00 11.50 1,400 3880314 CA*F4961*6D*+EEP 41,000 31,400 13.00 11.00 1,400 4887677 CAPT4961*4A*G*E80603B*B* 41,000 31,400 13.50 11.50 1,355 6945520 CAPT4961*4A*G*E80805C*B* 41,000 31,400 14.00 12.00 1,350 6945522 CAPT4961*4A*G*E81005C*B* 41,000 31,400 14.00 12.00 1,300 6945529 CAPT4961*4A*A*VC80604B*B* 41,000 31,400 14.00 12.00 1,410 6945534 CAPT4961*4A*A*VC80805C*B* 41,000 31,400 14.00 12.00 1,395 6945540 CAPT4961*4A*A*VC81005C*B* 41,000 31,400 14.00 12.00 1,370 6945545 CAPT4961*4A*A*VC950704CXB* 41,000 31,400 14.00 12.00 1,400 6945550 CAPT4961*4A*G*VC950704CXB* 41,000 31,400 14.00 12.00 1,400 6945551 CAPT4961*4A*A*VC950714CXB* 41,000 31,400 14.00 12.00 1,400 6945562 CAPT4961*4A*G*VC950714CXB* 41,000 31,400 14.00 12.00 1,400 6945563 CAPT4961*4A*A*VC950905DXB* 41,000 31,400 14.00 12.00 1,400 6945580 CAPT4961*4A*G*VC950905DXB* 41,000 31,400 14.00 12.00 1,400 6945581 CAPT4961*4A*A*VC950915DXB* 41,000 31,400 14.00 12.00 1,400 6945590 CAPT4961*4A*G*VC950915DXB* 41,000 31,400 14.00 12.00 1,400 6945591 CAPT4961*4A*A*VC951155DXB* 41,000 31,400 14.00 12.00 1,425 6945600 CAPT4961*4A*G*VC951155DXB* 41,000 31,400 14.00 12.00 1,425 6945601 CAPT4961*4A*A*VM960603BXB* 40,500 31,000 13.50 11.50 1,320 6945610 CAPT4961*4A*G*VM960603BXB* 40,500 31,000 13.50 11.50 1,320 6945611 CAPT4961*4A*A*VM960604CXB* 41,000 31,400 14.00 12.00 1,400 6945614 CAPT4961*4A*G*VM960604CXB* 41,000 31,400 14.00 12.00 1,400 6945615 CAPT4961*4A*A*VM960805CXB* 41,000 31,400 14.00 12.00 1,400 6945624 CAPT4961*4A*G*VM960805CXB* 41,000 31,400 14.00 12.00 1,400 6945625 CAPT4961*4A*A*VM960805DXB* 41,000 31,400 14.00 12.00 1,400 6945634 CAPT4961*4A*G*VM960805DXB* 41,000 31,400 14.00 12.00 1,400 6945635 CAPT4961*4A*A*VM961005DXB* 41,000 31,400 14.00 12.00 1,400 6945645 CAPT4961*4A*G*VM961005DXB* 41,000 31,400 14.00 12.00 1,400 6945646 CAPT4961*4A*A*VM961155DXB* 41,000 31,400 14.00 12.00 1,400 6945655 CAPT4961*4A*G*VM961155DXB* 41,000 31,400 14.00 12.00 1,400 6945656 CAPT4961*4A*ADVC80805C*B* 41,000 31,400 14.00 12.00 1,380 6945664 CAPT4961*4A*ADVC81005C*B* 41,000 31,400 14.00 12.00 1,405 6945668 CAPT4961*4A*GME950805CXA* 40,500 31,000 14.00 12.00 1,400 6945672 CAPT4961*4A*GME951005DXA* 41,000 31,400 14.00 12.00 1,440 6945678 CAPT4961*4A*+EEP 40,500 31,000 13.00 11.00 1,400 5611311 CAPT4961*4A*+MBVC1600**-1A*41,000 31,400 14.00 11.50 1,375 5611312 Product SPecificationS SS-GSX13 www.goodmanmfg.com 31 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0421B* (cont.) CAPT4961*4A*+MBVC2000**-1A*41,000 31,400 14.00 11.50 1,400 5611313 CHPF3642C6C*G*E80805C*B* 40,000 30,600 13.00 11.30 1,350 5039027 CHPF3642C6C*A*EH800805C*A* 40,000 30,600 13.00 11.30 1,350 6944908 CHPF3642C6C*+EEP 40,000 30,600 13.00 11.00 1,400 3539875 CHPF3642D6C*G*VC91155DXA* 40,000 30,600 13.50 11.30 1,400 3597929 CHPF3642D6C*G*VC950905CXB* 40,000 30,600 13.50 11.30 1,400 5621024 CHPF3642D6C*G*VC950905DXB* 40,000 30,600 13.50 11.30 1,400 5621028 CHPF3642D6C*A*VM960604CXB* 40,000 30,600 13.50 11.30 1,400 5621037 CHPF3642D6C*G*VM960604CXB* 40,000 30,600 13.50 11.30 1,400 5621038 CHPF3642D6C*G*VM960805CXB* 40,000 30,600 13.50 11.30 1,400 5621042 CHPF3642D6C*G*VM960805DXB* 40,000 30,600 13.50 11.30 1,400 5621045 CHPF3642D6C*A*VC950905CXB* 40,000 30,600 13.50 11.30 1,400 6497570 CHPF3642D6C*A*VC950905DXB* 40,000 30,600 13.50 11.30 1,400 6497571 CHPF3642D6C*A*VM960805CXB* 40,000 30,600 13.50 11.30 1,400 6497572 CHPF3642D6C*A*VM960805DXB* 40,000 30,600 13.50 11.30 1,400 6497573 CHPF3642D6C*+EEP 40,000 30,600 13.00 11.00 1,400 3539877 CHPF3743C6B*+EEP 40,000 30,600 13.00 11.00 1,400 6497574 CHPF4860D6D*GME951005DXA* 40,500 31,000 13.50 11.00 1,440 4703542 CHPF4860D6D*GME950805CXA* 40,500 31,000 14.00 11.30 1,400 4703732 CHPF4860D6D*G*E80805C*B* 41,000 31,400 13.50 11.50 1,510 5038972 CHPF4860D6D*G*VC950905CXB* 41,000 31,400 14.00 11.50 1,400 5621025 CHPF4860D6D*G*VC950905DXB* 41,000 31,400 14.00 11.50 1,400 5621029 CHPF4860D6D*G*VC951155DXB* 41,000 31,400 14.00 11.50 1,400 5621033 CHPF4860D6D*A*VM960604CXB* 41,000 31,400 14.00 11.50 1,400 5621039 CHPF4860D6D*G*VM960604CXB* 41,000 31,400 14.00 11.50 1,400 5621040 CHPF4860D6D*G*VM960805CXB* 41,000 31,400 14.00 11.50 1,400 5621043 CHPF4860D6D*G*VM960805DXB* 41,000 31,400 14.00 11.50 1,400 5621046 CHPF4860D6D*G*VM961005DXB* 41,000 31,400 14.00 11.50 1,400 5621048 CHPF4860D6D*G*VM961155DXB* 41,000 31,400 14.00 11.50 1,400 5621050 CHPF4860D6D*A*VC950905CXB* 41,000 31,400 14.00 11.50 1,400 6497575 CHPF4860D6D*A*VC950905DXB* 41,000 31,400 14.00 11.50 1,400 6497576 CHPF4860D6D*A*VC951155DXB* 41,000 31,400 14.00 11.50 1,400 6497577 CHPF4860D6D*A*VM960805CXB* 41,000 31,400 14.00 11.50 1,400 6497578 CHPF4860D6D*A*VM960805DXB* 41,000 31,400 14.00 11.50 1,400 6497579 CHPF4860D6D*A*VM961005DXB* 41,000 31,400 14.00 11.50 1,400 6497580 CHPF4860D6D*A*VM961155DXB* 41,000 31,400 14.00 11.50 1,400 6497581 CHPF4860D6D*A*EH800805C*A* 41,000 31,400 13.50 11.50 1,510 6944910 CHPF4860D6D*AMEH960805CXA* 40,500 31,000 14.00 11.30 1,400 6944912 CHPF4860D6D*AMEH961005DXA* 40,500 31,000 13.50 11.00 1,440 6944914 CHPF4860D6D*+EEP 41,000 31,400 13.00 11.00 1,400 3539879 CHPF4860D6D*+MBVC1600**-1A*41,000 31,400 14.00 11.50 1,400 3609448 CSCF3642N6D*+EEP 40,000 30,600 13.00 11.00 1,325 4767422 CSCF4860N6D*G*VC950905CXB* 41,000 31,400 13.50 11.30 1,450 5621026 CSCF4860N6D*G*VC951155DXB* 41,000 31,400 13.50 11.30 1,425 5621034 CSCF4860N6D*A*VC951155DXB* 41,000 31,400 13.50 11.30 1,425 6497582 CSCF4860N6D*+EEP 41,000 31,400 13.00 11.00 1,325 4767426 Product SPecificationS 32 www.goodmanmfg.com SS-GSX13 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0481B* CHPF4860D6D*+EEP 46,000 35,200 13.00 11.00 1,600 3539868 ARPT48D14A*46,000 35,200 13.50 11.00 1,475 5360117 ARPT60D14A*46,000 35,200 13.50 11.00 1,500 5360118 ARUF48D14A*44,500 34,200 13.00 11.00 1,550 5360119 ARUF48D14A*+TXV 44,500 34,200 13.00 11.00 1,550 5378542 ARUF60D14A*44,500 34,200 13.00 11.00 1,460 5360120 ARUF60D14A*+TXV 44,500 34,200 13.00 11.00 1,460 5378543 ASPT48D14A*46,000 35,200 13.80 11.30 1,600 5796511 ASPT60D14A*46,000 35,200 13.80 11.30 1,600 5722556 ASUF49C14A*43,000 33,000 13.00 11.00 1,435 5620405 ASUF49C14A*+TXV 43,000 33,000 13.30 11.00 1,435 5620406 AVPTC48D14A*46,000 35,200 13.80 11.30 1,615 5924446 CA*F4860*6D*+EEP 46,000 35,200 13.00 11.00 1,600 4214133 CA*F4860*6D*+MBVC2000**-1A*46,000 35,200 14.00 11.30 1,600 3880321 CA*F4860*6D*+TXV GME950805CXA* 45,500 34,800 14.00 11.30 1,550 4703516 CA*F4860*6D*+TXV GME951005DXA* 45,500 34,800 13.70 11.30 1,650 4703548 CA*F4860*6D*+TXV G*E80805C*B* 46,000 35,200 13.50 11.30 1,650 5039233 CA*F4860*6D*+TXV G*E81005C*B* 46,000 35,200 13.50 11.30 1,570 5039261 CA*F4860*6D*+TXV A*VC950714CXB* 46,000 35,200 14.00 11.30 1,550 5621051 CA*F4860*6D*+TXV G*VC950714CXB* 46,000 35,200 14.00 11.30 1,620 5621052 CA*F4860*6D*+TXV G*VC950905CXB* 46,000 35,200 14.00 11.30 1,620 5621053 CA*F4860*6D*+TXV G*VC950905DXB* 46,000 35,200 14.00 11.30 1,620 5621056 CA*F4860*6D*+TXV A*VC950915DXB* 46,000 35,200 14.00 11.30 1,620 5621059 CA*F4860*6D*+TXV G*VC950915DXB* 46,000 35,200 14.00 11.30 1,620 5621060 CA*F4860*6D*+TXV G*VC951155DXB* 46,000 35,200 14.00 11.30 1,620 5621061 CA*F4860*6D*+TXV A*VM960604CXB* 46,000 35,200 14.00 11.30 1,550 5621064 CA*F4860*6D*+TXV G*VM960604CXB* 46,000 35,200 14.00 11.30 1,620 5621065 CA*F4860*6D*+TXV G*VM960805CXB* 46,000 35,200 14.00 11.30 1,620 5621068 CA*F4860*6D*+TXV G*VM960805DXB* 46,000 35,200 14.00 11.30 1,620 5621070 CA*F4860*6D*+TXV G*VM961005DXB* 46,000 35,200 14.00 11.30 1,620 5621072 CA*F4860*6D*+TXV G*VM961155DXB* 46,000 35,200 14.00 11.30 1,620 5621074 CA*F4860*6D*+TXV A*VC950905CXB* 46,000 35,200 14.00 11.30 1,620 6497583 CA*F4860*6D*+TXV A*VC950905DXB* 46,000 35,200 14.00 11.30 1,620 6497584 CA*F4860*6D*+TXV A*VC951155DXB* 46,000 35,200 14.00 11.30 1,620 6497585 CA*F4860*6D*+TXV A*VM960805CXB* 46,000 35,200 14.00 11.30 1,620 6497586 CA*F4860*6D*+TXV A*VM960805DXB* 46,000 35,200 14.00 11.30 1,620 6497587 CA*F4860*6D*+TXV A*VM961005DXB* 46,000 35,200 14.00 11.30 1,620 6497588 CA*F4860*6D*+TXV A*VM961155DXB* 46,000 35,200 14.00 11.30 1,620 6497589 CA*F4860*6D*+TXV A*EH800805C*A* 46,000 35,200 13.50 11.30 1,650 6944916 CA*F4860*6D*+TXV A*EH801005C*A* 46,000 35,200 13.50 11.30 1,570 6944918 CA*F4860*6D*+TXV AMEH960805CXA* 45,500 34,800 14.00 11.30 1,550 6944920 CA*F4860*6D*+TXV AMEH961005DXA* 45,500 34,800 13.70 11.30 1,650 6944921 CA*F4961*6D*+EEP 46,000 35,200 13.00 11.00 1,600 5685098 CAPT4961*4A*G*E80805C*B* 46,000 35,200 13.50 11.50 1,480 6945523 CAPT4961*4A*G*E81005C*B* 47,000 36,000 13.50 11.50 1,570 6945530 CAPT4961*4A*A*VC80604B*B* 47,000 36,000 13.50 11.50 1,545 6945535 CAPT4961*4A*A*VC80805C*B* 47,000 36,000 13.50 11.50 1,590 6945541 CAPT4961*4A*A*VC81005C*B* 47,000 36,000 13.50 11.50 1,600 6945546 CAPT4961*4A*A*VC950704CXB* 47,000 36,000 13.00 11.00 1,650 6945552 CAPT4961*4A*G*VC950704CXB* 47,000 36,000 13.00 11.00 1,650 6945553 CAPT4961*4A*A*VC950714CXB* 46,000 35,200 13.00 11.00 1,550 6945564 CAPT4961*4A*G*VC950714CXB* 46,000 35,200 13.00 11.00 1,550 6945565 CAPT4961*4A*A*VC950905CXB* 47,000 36,000 13.00 11.00 1,575 6945574 CAPT4961*4A*G*VC950905CXB* 47,000 36,000 13.00 11.00 1,575 6945575 Product SPecificationS SS-GSX13 www.goodmanmfg.com 33 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0481B* (cont.) CAPT4961*4A*A*VC950905DXB* 47,000 36,000 13.50 11.50 1,575 6945582 CAPT4961*4A*G*VC950905DXB* 47,000 36,000 13.50 11.50 1,575 6945583 CAPT4961*4A*A*VC950915DXB* 46,000 35,200 13.50 11.50 1,575 6945592 CAPT4961*4A*G*VC950915DXB* 46,000 35,200 13.50 11.50 1,575 6945593 CAPT4961*4A*A*VC951155DXB* 47,000 36,000 13.50 11.50 1,550 6945602 CAPT4961*4A*G*VC951155DXB* 47,000 36,000 13.50 11.50 1,550 6945603 CAPT4961*4A*A*VM960604CXB* 47,000 36,000 13.00 11.00 1,550 6945616 CAPT4961*4A*G*VM960604CXB* 47,000 36,000 13.00 11.00 1,550 6945617 CAPT4961*4A*A*VM960805CXB* 47,000 36,000 13.00 11.00 1,620 6945626 CAPT4961*4A*G*VM960805CXB* 47,000 36,000 13.00 11.00 1,620 6945627 CAPT4961*4A*A*VM960805DXB* 47,000 36,000 13.50 11.50 1,620 6945636 CAPT4961*4A*G*VM960805DXB* 47,000 36,000 13.50 11.50 1,620 6945637 CAPT4961*4A*A*VM961005DXB* 47,000 36,000 13.00 11.00 1,620 6945647 CAPT4961*4A*G*VM961005DXB* 47,000 36,000 13.00 11.00 1,620 6945648 CAPT4961*4A*A*VM961155DXB* 47,000 36,000 13.50 11.50 1,620 6945657 CAPT4961*4A*ADVC80805C*B* 47,000 36,000 13.50 11.50 1,585 6945665 CAPT4961*4A*ADVC81005C*B* 47,000 36,000 13.50 11.50 1,620 6945669 CAPT4961*4A*GME950805CXA* 47,000 36,000 13.00 11.00 1,550 6945673 CAPT4961*4A*GME951005DXA* 47,000 36,000 13.50 11.50 1,650 6945679 CAPT4961*4A*+EEP 46,500 35,600 13.00 11.00 1,600 5611314 CAPT4961*4A*+MBVC1600**-1A*47,000 36,000 14.00 11.50 1,500 5611315 CAPT4961*4A*+MBVC2000**-1A*47,000 36,000 14.00 11.50 1,550 5611316 CHPF4860D6D*+MBVC2000**-1A*46,000 35,200 14.00 11.30 1,600 3609452 CHPF4860D6D*+TXV GME950805CXA* 45,500 34,800 14.00 11.30 1,550 4703518 CHPF4860D6D*+TXV GME951005DXA* 45,500 34,800 13.70 11.30 1,650 4703552 CHPF4860D6D*+TXV G*E81005C*B* 46,000 35,200 13.50 11.30 1,570 5038912 CHPF4860D6D*+TXV G*E80805C*B* 46,000 35,200 13.50 11.30 1,650 5039110 CHPF4860D6D*+TXV G*VC950905CXB* 46,000 35,200 14.00 11.30 1,620 5621054 CHPF4860D6D*+TXV G*VC950905DXB* 46,000 35,200 14.00 11.30 1,620 5621057 CHPF4860D6D*+TXV G*VC951155DXB* 46,000 35,200 14.00 11.30 1,620 5621062 CHPF4860D6D*+TXV A*VM960604CXB* 46,000 35,200 14.00 11.30 1,550 5621066 CHPF4860D6D*+TXV G*VM960604CXB* 46,000 35,200 14.00 11.30 1,620 5621067 CHPF4860D6D*+TXV G*VM960805CXB* 46,000 35,200 14.00 11.30 1,620 5621069 CHPF4860D6D*+TXV G*VM960805DXB* 46,000 35,200 14.00 11.30 1,620 5621071 CHPF4860D6D*+TXV G*VM961005DXB* 46,000 35,200 14.00 11.30 1,620 5621073 CHPF4860D6D*+TXV G*VM961155DXB* 46,000 35,200 14.00 11.30 1,620 5621075 CHPF4860D6D*+TXV A*VC950905CXB* 46,000 35,200 14.00 11.30 1,620 6497590 CHPF4860D6D*+TXV A*VC950905DXB* 46,000 35,200 14.00 11.30 1,620 6497591 CHPF4860D6D*+TXV A*VC951155DXB* 46,000 35,200 14.00 11.30 1,620 6497592 CHPF4860D6D*+TXV A*VM960805CXB* 46,000 35,200 14.00 11.30 1,620 6497593 CHPF4860D6D*+TXV A*VM960805DXB* 46,000 35,200 14.00 11.30 1,620 6497594 CHPF4860D6D*+TXV A*VM961005DXB* 46,000 35,200 14.00 11.30 1,620 6497595 CHPF4860D6D*+TXV A*VM961155DXB* 46,000 35,200 14.00 11.30 1,620 6497596 CHPF4860D6D*+TXV A*EH800805C*A* 46,000 35,200 13.50 11.30 1,650 6944923 CHPF4860D6D*+TXV A*EH801005C*A* 46,000 35,200 13.50 11.30 1,570 6944925 CHPF4860D6D*+TXV AMEH960805CXA* 45,500 34,800 14.00 11.30 1,550 6944927 CHPF4860D6D*+TXV AMEH961005DXA* 45,500 34,800 13.70 11.30 1,650 6944928 CSCF4860N6D*+EEP 46,000 35,200 13.00 11.00 1,600 4767427 CSCF4860N6D*+TXV G*VC950905CXB* 46,000 35,200 14.00 11.30 1,575 5621055 CSCF4860N6D*+TXV G*VC950905DXB*46,000 35,200 14.00 11.30 1,575 5621058 CSCF4860N6D*+TXV G*VC951155DXB* 46,000 35,200 14.00 11.30 1,550 5621063 CSCF4860N6D*+TXV A*VC950905CXB* 46,000 35,200 14.00 11.30 1,575 6497597 CSCF4860N6D*+TXV A*VC950905DXB* 46,000 35,200 14.00 11.30 1,575 6497598 CSCF4860N6D*+TXV A*VC951155DXB* 46,000 35,200 14.00 11.30 1,550 6497599 Product SPecificationS 34 www.goodmanmfg.com SS-GSX13 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0601B* ASPT60D14A*56,000 40,000 13.00 11.00 1,700 6349241 ASUF59D14A*54,000 38,500 13.00 11.00 1,580 5600192 AVPTC60D14A*56,000 40,000 13.00 11.00 1,750 6349242 CA*F4961*6D*+EEP 55,500 39,500 13.00 11.00 1,650 4945868 CA*F4961*6D*+MBVC2000**-1A*56,000 40,000 13.50 11.50 1,650 4431670 CA*F4961*6D*+MBVC2000**-1A*+TXV 56,000 40,000 13.50 11.50 1,750 4431671 CA*F4961*6D*+TXV G*E81005C*B* 55,000 39,000 13.30 11.20 1,720 5038893 CA*F4961*6D*+TXV G*VC81005C*B* 55,500 39,500 13.30 11.20 1,700 5038945 CA*F4961*6D*+TXV G*E80805C*B* 54,500 38,500 13.30 11.20 1,650 5038979 CA*F4961*6D*+TXV G*VC80805C*B* 55,500 39,500 13.30 11.20 1,700 5039111 CA*F4961*6D*+TXV A*VC81005C*B* 55,500 39,500 13.30 11.20 1,800 5039112 CA*F4961*6D*+TXV A*VC80805C*B* 55,500 39,500 13.30 11.20 1,800 5039235 CA*F4961*6D*+TXV A*VC950714CXB* 55,000 39,000 13.00 11.00 1,700 5621076 CA*F4961*6D*+TXV G*VC950714CXB* 55,000 39,000 13.00 11.00 1,700 5621077 CA*F4961*6D*+TXV G*VC950905CXB* 55,000 39,000 13.00 11.00 1,700 5621080 CA*F4961*6D*+TXV G*VC950905DXB* 55,000 39,000 13.00 11.00 1,700 5621083 CA*F4961*6D*+TXV A*VC950915DXB* 55,000 39,000 13.00 11.00 1,700 5621086 CA*F4961*6D*+TXV G*VC950915DXB* 55,000 39,000 13.00 11.00 1,700 5621087 CA*F4961*6D*+TXV G*VC951155DXB* 54,500 38,500 13.40 11.20 1,620 5621090 CA*F4961*6D*+TXV G*VM960805CXB* 55,000 39,000 13.00 11.00 1,700 5621095 CA*F4961*6D*+TXV G*VM960805DXB* 55,000 39,000 13.00 11.00 1,700 5621098 CA*F4961*6D*+TXV G*VM961005DXB* 54,500 38,500 13.40 11.20 1,620 5621101 CA*F4961*6D*+TXV G*VM961155DXB* 54,500 38,500 13.40 11.20 1,620 5621104 CA*F4961*6D*+TXV A*VC950905CXB* 55,000 39,000 13.00 11.00 1,700 6497600 CA*F4961*6D*+TXV A*VC950905DXB* 55,000 39,000 13.00 11.00 1,700 6497601 CA*F4961*6D*+TXV A*VC951155DXB* 54,500 38,500 13.40 11.20 1,620 6497602 CA*F4961*6D*+TXV A*VM960805CXB* 55,000 39,000 13.00 11.00 1,700 6497603 CA*F4961*6D*+TXV A*VM961005DXB* 54,500 38,500 13.40 11.20 1,620 6497604 CA*F4961*6D*+TXV A*VM961155DXB* 54,500 38,500 13.40 11.20 1,620 6497605 CA*F4961*6D*+TXV A*EH800805C*A* 54,500 38,500 13.30 11.20 1,650 6944930 CA*F4961*6D*+TXV A*EH801005C*A* 55,000 39,000 13.30 11.20 1,720 6944932 CAPT4961*4A*A*VC80805C*B* 55,500 39,500 13.00 11.00 1,625 5520629 CAPT4961*4A*A*VC81005C*B* 55,500 39,500 13.00 11.00 1,625 5520630 CAPT4961*4A*ADVC80805C*B* 55,500 39,500 13.00 11.00 1,625 5520634 CAPT4961*4A*ADVC81005C*B* 55,500 39,500 13.00 11.00 1,625 5520635 CAPT4961*4A*G*E80805C*B* 54,500 38,500 13.00 11.00 1,675 5520636 CAPT4961*4A*G*E81005C*B* 55,000 39,000 13.00 11.00 1,625 5520637 CAPT4961*4A*G*VC80805C*B* 55,500 39,500 13.00 11.00 1,625 5520638 CAPT4961*4A*G*VC81005C*B* 55,500 39,500 13.00 11.00 1,625 5520639 CAPT4961*4A*A*VC950714CXB* 55,000 39,000 13.00 11.00 1,600 5621078 CAPT4961*4A*G*VC950714CXB* 55,000 39,000 13.00 11.00 1,600 5621079 CAPT4961*4A*G*VC950905CXB* 55,000 39,000 13.00 11.00 1,560 5621081 CAPT4961*4A*G*VC950905DXB* 55,000 39,000 13.00 11.00 1,560 5621084 CAPT4961*4A*A*VC950915DXB* 55,000 39,000 13.00 11.00 1,660 5621088 CAPT4961*4A*G*VC950915DXB* 55,000 39,000 13.00 11.00 1,660 5621089 CAPT4961*4A*G*VC951155DXB* 54,500 38,500 13.00 11.00 1,625 5621091 CAPT4961*4A*A*VM960604CXB* 55,000 39,000 13.00 11.00 1,600 5621093 Product SPecificationS SS-GSX13 www.goodmanmfg.com 35 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0601B* (cont.) CAPT4961*4A*G*VM960604CXB* 55,000 39,000 13.00 11.00 1,600 5621094 CAPT4961*4A*G*VM960805CXB* 55,000 39,000 13.00 11.00 1,600 5621096 CAPT4961*4A*G*VM960805DXB* 55,000 39,000 13.00 11.00 1,600 5621099 CAPT4961*4A*G*VM961005DXB* 54,500 38,500 13.00 11.00 1,625 5621102 CAPT4961*4A*G*VM961155DXB* 54,500 38,500 13.00 11.00 1,625 5621105 CAPT4961*4A*A*VC950905CXB* 55,000 39,000 13.00 11.00 1,560 6497606 CAPT4961*4A*A*VC950905DXB* 55,000 39,000 13.00 11.00 1,560 6497607 CAPT4961*4A*A*VC951155DXB* 54,500 38,500 13.00 11.00 1,660 6497608 CAPT4961*4A*A*VM960805CXB* 55,000 39,000 13.00 11.00 1,560 6497609 CAPT4961*4A*A*VM961005DXB* 54,500 38,500 13.00 11.00 1,530 6497610 CAPT4961*4A*A*VM961155DXB* 54,500 38,500 13.00 11.00 1,660 6497611 CAPT4961*4A*A*EH800805C*A* 54,500 38,500 13.00 11.00 1,675 6944934 CAPT4961*4A*A*EH801005C*A* 55,000 39,000 13.00 11.00 1,625 6944936 CAPT4961*4A*56,500 40,000 13.00 11.00 1,600 6945515 CAPT4961*4A*A*VC950704CXB* 56,500 40,000 13.00 11.00 1,650 6945554 CAPT4961*4A*G*VC950704CXB* 56,500 40,000 13.00 11.00 1,650 6945555 CAPT4961*4A*A*VM960805DXB* 56,500 40,000 13.00 11.00 1,700 6945638 CAPT4961*4A*GME950805CXA* 56,500 40,000 13.00 11.00 1,580 6945674 CAPT4961*4A*GME951005DXA* 56,500 40,000 13.00 11.00 1,655 6945680 CAPT4961*4A*+MBVC1600**-1A*57,000 40,500 13.00 11.00 1,700 6945516 CAPT4961*4A*+MBVC2000**-1A*56,000 40,000 13.50 11.50 1,625 5527435 CHPF4860D6D*+EEP+TXV 55,500 39,500 13.00 11.00 1,500 5604754 CHPF4860D6D*+MBVC2000**-1A*+TXV 56,000 40,000 13.50 11.50 1,625 3688586 CHPF4860D6D*+TXV G*VC81005C*B* 55,500 39,500 13.00 11.00 1,800 5038848 CHPF4860D6D*+TXV A*VC80805C*B* 55,500 39,500 13.00 11.00 1,800 5038849 CHPF4860D6D*+TXV G*VC80805C*B* 55,500 39,500 13.00 11.00 1,800 5038946 CHPF4860D6D*+TXV A*VC81005C*B* 55,500 39,500 13.00 11.00 1,800 5039148 CHPF4860D6D*+TXV G*E80805C*B* 54,500 38,500 13.30 11.20 1,650 5039181 CHPF4860D6D*+TXV G*E81005C*B* 55,000 39,000 13.30 11.20 1,720 5039194 CHPF4860D6D*+TXV G*VC950905CXB* 55,000 39,000 13.00 11.00 1,700 5621082 CHPF4860D6D*+TXV G*VC950905DXB* 55,500 39,500 13.20 11.00 1,700 5621085 CHPF4860D6D*+TXV G*VC951155DXB* 55,000 39,000 13.00 11.00 1,620 5621092 CHPF4860D6D*+TXV G*VM960805CXB* 55,000 39,000 13.00 11.00 1,700 5621097 CHPF4860D6D*+TXV G*VM960805DXB* 56,500 40,000 13.00 11.00 1,700 5621100 CHPF4860D6D*+TXV G*VM961005DXB* 55,000 39,000 13.00 11.00 1,620 5621103 CHPF4860D6D*+TXV G*VM961155DXB* 55,000 39,000 13.40 11.30 1,620 5621106 CHPF4860D6D*+TXV A*VC950905CXB* 55,000 39,000 13.00 11.00 1,700 6497612 CHPF4860D6D*+TXV A*VC950905DXB* 55,000 39,000 13.20 11.00 1,700 6497613 CHPF4860D6D*+TXV A*VC951155DXB* 55,000 39,000 13.00 11.00 1,620 6497614 CHPF4860D6D*+TXV A*VM960805CXB* 55,000 39,000 13.00 11.00 1,700 6497615 CHPF4860D6D*+TXV A*VM960805DXB* 55,000 39,000 13.00 11.00 1,700 6497616 CHPF4860D6D*+TXV A*VM961005DXB* 55,000 39,000 13.00 11.00 1,620 6497617 CHPF4860D6D*+TXV A*VM961155DXB* 55,000 39,000 13.40 11.30 1,620 6497618 CHPF4860D6D*+TXV A*EH800805C*A* 54,500 38,500 13.30 11.20 1,650 6944938 CHPF4860D6D*+TXV A*EH801005C*A* 55,000 39,000 13.30 11.20 1,720 6944940 CSCF4860N6D*+EEP 54,000 38,500 13.00 11.00 1,600 5446159 CSCF4860N6D*+MBVC2000**-1A*53,500 38,000 13.50 11.50 1,650 4767698 Product SPecificationS 36 www.goodmanmfg.com SS-GSX13 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0611A* ARPT48D14A*54,500 37,400 13.00 11.00 1,500 5586528 ARPT60D14A*55,000 37,600 13.00 11.00 1,500 5586693 ARUF48D14A*54,500 37,400 13.00 11.00 1,500 5586531 ARUF60D14A*55,000 37,600 13.00 11.00 1,500 5586696 ASPT60D14A*56,000 38,500 14.00 11.50 1,600 5722560 ASUF49C14A*51,500 35,200 13.00 11.00 1,435 5620411 ASUF49C14A*+TXV 51,500 35,200 13.20 11.00 1,435 5620412 ASUF59D14A*56,000 38,500 13.50 11.00 1,580 5600189 ASUF59D14A*+TXV 56,000 38,500 14.00 11.50 1,600 5722605 AVPTC60D14A*56,000 38,500 14.00 11.50 1,620 5924344 CA*F4860*6D*+EEP 55,000 37,600 13.00 11.00 1,500 5586534 CA*F4860*6D*+MBVC2000**-1A*56,000 38,500 13.50 11.50 1,575 5586537 CA*F4860*6D*+MBVC2000**-1A*+TXV 56,000 38,500 14.00 11.50 1,575 5586540 CA*F4860*6D*+TXV A*VC81005C*B* 55,500 38,000 13.50 11.00 1,520 5586543 CA*F4860*6D*+TXV ADVC80805C*B* 55,500 38,000 13.00 11.00 1,500 5586558 CA*F4860*6D*+TXV G*E80805C*B* 55,500 38,000 13.00 11.00 1,550 5586561 CA*F4860*6D*+TXV G*VC81005C*B* 55,500 38,000 13.50 11.00 1,520 5586564 CA*F4860*6D*+TXV GME950805CXA* 55,000 37,600 13.00 11.00 1,475 5586576 CA*F4860*6D*+TXV GME951005DXA* 55,000 37,600 13.50 11.00 1,500 5586579 CA*F4860*6D*+TXV A*VC80805C*B* 55,500 38,000 13.50 11.00 1,520 5586705 CA*F4860*6D*+TXV ADVC81005C*B* 55,500 38,000 13.00 11.00 1,550 5586714 CA*F4860*6D*+TXV G*E81005C*B* 55,000 37,600 13.50 11.00 1,525 5586717 CA*F4860*6D*+TXV G*VC80805C*B* 55,500 38,000 13.50 11.00 1,520 5586720 CA*F4860*6D*+TXV A*VC950905CXB* 55,500 38,000 13.00 11.00 1,460 5621107 CA*F4860*6D*+TXV G*VC950905CXB* 55,500 38,000 13.00 11.00 1,460 5621108 CA*F4860*6D*+TXV A*VC950905DXB* 55,500 38,000 13.50 11.00 1,460 5621116 CA*F4860*6D*+TXV G*VC950905DXB* 55,500 38,000 13.50 11.00 1,460 5621117 CA*F4860*6D*+TXV A*VC950915DXB* 55,000 37,600 13.00 11.00 1,575 5621125 CA*F4860*6D*+TXV G*VC950915DXB* 55,000 37,600 13.00 11.00 1,575 5621126 CA*F4860*6D*+TXV A*VC951155DXB* 55,000 37,600 13.00 11.00 1,550 5621135 CA*F4860*6D*+TXV G*VC951155DXB* 55,000 37,600 13.00 11.00 1,550 5621136 CA*F4860*6D*+TXV A*VM960805CXB* 55,500 38,000 13.00 11.00 1,460 5621144 CA*F4860*6D*+TXV G*VM960805CXB* 55,500 38,000 13.00 11.00 1,460 5621145 CA*F4860*6D*+TXV A*VM960805DXB* 55,500 38,000 13.00 11.00 1,460 5621154 CA*F4860*6D*+TXV G*VM960805DXB* 55,500 38,000 13.00 11.00 1,460 5621155 CA*F4860*6D*+TXV A*VM961005DXB* 55,000 37,600 13.50 11.00 1,550 5621164 CA*F4860*6D*+TXV G*VM961005DXB* 55,000 37,600 13.50 11.00 1,550 5621165 CA*F4860*6D*+TXV A*VM961155DXB* 55,000 37,600 13.50 11.00 1,550 5621174 CA*F4860*6D*+TXV G*VM961155DXB* 55,000 37,600 13.50 11.00 1,550 5621175 CA*F4860*6D*+TXV A*EH800805C*A* 55,500 38,000 13.00 11.00 1,550 6944942 CA*F4860*6D*+TXV A*EH801005C*A* 55,000 37,600 13.50 11.00 1,525 6944944 CA*F4860*6D*+TXV AMEH960805CXA* 55,000 37,600 13.00 11.00 1,475 6944946 CA*F4860*6D*+TXV AMEH961005DXA* 55,000 37,600 13.50 11.00 1,500 6944948 CA*F4961*6D*+EEP 56,500 38,500 13.00 11.00 1,500 5586582 CA*F4961*6D*+MBVC2000**-1A*57,000 39,000 14.00 11.50 1,575 5586856 CA*F4961*6D*+MBVC2000**-1A*+TXV 57,000 39,000 14.50 12.00 1,575 5586585 CA*F4961*6D*+TXV A*VC80805C*B* 56,500 38,500 14.00 11.50 1,520 5586588 CA*F4961*6D*+TXV A*VC81005C*B* 56,500 38,500 14.00 11.50 1,520 5586591 CA*F4961*6D*+TXV ADVC80805C*B* 57,000 39,000 13.50 11.00 1,500 5586600 CA*F4961*6D*+TXV ADVC81005C*B* 57,000 39,000 13.50 11.00 1,550 5586603 CA*F4961*6D*+TXV G*E80805C*B* 56,000 38,500 14.00 11.50 1,550 5586606 CA*F4961*6D*+TXV G*E81005C*B* 56,000 38,500 14.00 11.50 1,525 5586609 CA*F4961*6D*+TXV G*VC80805C*B* 56,500 38,500 14.00 11.50 1,520 5586612 Product SPecificationS SS-GSX13 www.goodmanmfg.com 37 Ahri rAtinGS (Cont.) See Notes on Page 39. Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0611A* (cont.) CA*F4961*6D*+TXV G*VC81005C*B* 56,500 38,500 14.00 11.50 1,520 5586615 CA*F4961*6D*+TXV GME950805CXA* 56,000 38,500 13.50 11.00 1,475 5586624 CA*F4961*6D*+TXV GME951005DXA* 56,000 38,500 14.00 11.50 1,500 5586627 CA*F4961*6D*+TXV G*VC91155DXA* 56,000 38,500 13.00 11.00 1,550 5593112 CA*F4961*6D*+TXV A*VC950905CXB* 56,500 38,500 13.50 11.00 1,460 5621109 CA*F4961*6D*+TXV G*VC950905CXB* 56,500 38,500 13.50 11.00 1,460 5621110 CA*F4961*6D*+TXV A*VC950905DXB* 56,500 38,500 14.00 11.50 1,460 5621118 CA*F4961*6D*+TXV G*VC950905DXB* 56,500 38,500 14.00 11.50 1,460 5621119 CA*F4961*6D*+TXV A*VC950915DXB* 56,000 38,500 13.50 11.00 1,575 5621127 CA*F4961*6D*+TXV G*VC950915DXB* 56,000 38,500 13.50 11.00 1,575 5621128 CA*F4961*6D*+TXV A*VC951155DXB* 56,000 38,500 14.00 11.50 1,550 5621137 CA*F4961*6D*+TXV G*VC951155DXB* 56,000 38,500 14.00 11.50 1,550 5621138 CA*F4961*6D*+TXV A*VM960805CXB* 56,500 38,500 13.50 11.00 1,460 5621146 CA*F4961*6D*+TXV G*VM960805CXB* 56,500 38,500 13.50 11.00 1,460 5621147 CA*F4961*6D*+TXV A*VM960805DXB* 56,500 38,500 13.50 11.00 1,460 5621156 CA*F4961*6D*+TXV G*VM960805DXB* 56,500 38,500 13.50 11.00 1,460 5621157 CA*F4961*6D*+TXV A*VM961005DXB* 56,000 38,500 14.00 11.50 1,550 5621166 CA*F4961*6D*+TXV G*VM961005DXB* 56,000 38,500 14.00 11.50 1,550 5621167 CA*F4961*6D*+TXV A*VM961155DXB* 56,000 38,500 14.00 11.50 1,550 5621176 CA*F4961*6D*+TXV G*VM961155DXB* 56,000 38,500 13.50 11.00 1,550 5621177 CA*F4961*6D*+TXV A*EH800805C*A* 56,000 38,500 14.00 11.50 1,550 6944950 CA*F4961*6D*+TXV A*EH801005C*A* 56,000 38,500 14.00 11.50 1,525 6944952 CA*F4961*6D*+TXV AMEH960805CXA* 56,000 38,500 13.50 11.00 1,475 6944954 CA*F4961*6D*+TXV AMEH961005DXA* 56,000 38,500 14.00 11.50 1,500 6944956 CAPT4961*4A*A*VC80805C*B* 56,500 38,500 14.00 11.50 1,520 5586630 CAPT4961*4A*A*VC81005C*B* 56,500 38,500 14.00 11.50 1,520 5586633 CAPT4961*4A*ADVC80805C*B* 57,000 39,000 13.50 11.00 1,500 5586642 CAPT4961*4A*ADVC81005C*B* 57,000 39,000 13.50 11.00 1,550 5586645 CAPT4961*4A*G*E80805C*B* 56,000 38,500 14.00 11.50 1,550 5586648 CAPT4961*4A*G*E81005C*B* 56,000 38,500 14.00 11.50 1,525 5586651 CAPT4961*4A*G*VC80805C*B* 56,500 38,500 14.00 11.50 1,520 5586654 CAPT4961*4A*G*VC81005C*B* 56,500 38,500 14.00 11.50 1,520 5586657 CAPT4961*4A*GME950805CXA* 56,000 38,500 13.50 11.00 1,475 5586666 CAPT4961*4A*GME951005DXA* 56,000 38,500 14.00 11.50 1,500 5586669 CAPT4961*4A*G*VC91155DXA* 56,000 38,500 13.50 11.00 1,550 5593115 CAPT4961*4A*A*VC950905CXB* 56,500 38,500 13.50 11.00 1,460 5621111 CAPT4961*4A*G*VC950905CXB* 56,500 38,500 13.50 11.00 1,460 5621112 CAPT4961*4A*A*VC950905DXB* 56,500 38,500 14.00 11.50 1,460 5621120 CAPT4961*4A*G*VC950905DXB* 56,500 38,500 14.00 11.50 1,460 5621121 CAPT4961*4A*A*VC950915DXB* 56,000 38,500 13.50 11.00 1,575 5621129 CAPT4961*4A*G*VC950915DXB* 56,000 38,500 13.50 11.00 1,575 5621130 CAPT4961*4A*A*VC951155DXB* 56,000 38,500 14.00 11.50 1,550 5621139 CAPT4961*4A*G*VC951155DXB* 56,000 38,500 14.00 11.50 1,550 5621140 CAPT4961*4A*A*VM960805CXB* 56,500 38,500 13.50 11.00 1,460 5621148 CAPT4961*4A*G*VM960805CXB* 56,500 38,500 13.50 11.00 1,460 5621149 CAPT4961*4A*A*VM960805DXB* 56,500 38,500 13.50 11.00 1,460 5621158 CAPT4961*4A*G*VM960805DXB* 56,500 38,500 13.50 11.00 1,460 5621159 CAPT4961*4A*A*VM961005DXB* 56,000 38,500 14.00 11.50 1,550 5621168 CAPT4961*4A*G*VM961005DXB* 56,000 38,500 14.00 11.50 1,550 5621169 CAPT4961*4A*A*VM961155DXB* 56,000 38,500 14.00 11.50 1,550 5621178 CAPT4961*4A*G*VM961155DXB* 56,000 38,500 13.50 11.00 1,550 5621179 CAPT4961*4A*A*EH800805C*A* 56,000 38,500 14.00 11.50 1,550 6944958 CAPT4961*4A*A*EH801005C*A* 56,000 38,500 14.00 11.50 1,525 6944960 Product SPecificationS 38 www.goodmanmfg.com SS-GSX13 Ahri rAtinGS (Cont.) Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0611A* (cont.) CAPT4961*4A*AMEH960805CXA* 56,000 38,500 13.50 11.00 1,475 6944962 CAPT4961*4A*AMEH961005DXA* 56,000 38,500 14.00 11.50 1,500 6944964 CAPT4961*4A*A*VC950704CXB* 57,000 39,000 13.00 11.00 1,450 6945556 CAPT4961*4A*G*VC950704CXB* 57,000 39,000 13.00 11.00 1,450 6945557 CAPT4961*4A*A*VC950714CXB* 57,000 39,000 13.00 11.00 1,530 6945566 CAPT4961*4A*G*VC950714CXB* 57,000 39,000 13.00 11.00 1,530 6945567 CAPT4961*4A*+EEP 56,500 38,500 13.50 11.00 1,500 5586770 CAPT4961*4A*+MBVC1600**-1A*57,000 39,000 13.50 11.50 1,560 6945517 CAPT4961*4A*+MBVC2000**-1A*57,000 39,000 14.50 12.00 1,575 5586672 CHPF4860D6D*+EEP 56,000 38,500 13.00 11.00 1,500 5586675 CHPF4860D6D*+MBVC2000**-1A*57,000 39,000 14.00 11.50 1,575 5586900 CHPF4860D6D*+MBVC2000**-1A*+TXV 57,000 39,000 14.00 11.50 1,575 5586773 CHPF4860D6D*+TXV GME950805CXA* 56,000 38,500 13.00 11.00 1,475 5586684 CHPF4860D6D*+TXV GME951005DXA* 56,000 38,500 14.00 11.50 1,500 5586687 CHPF4860D6D*+TXV A*VC80805C*B* 56,000 38,500 14.00 11.50 1,520 5586776 CHPF4860D6D*+TXV A*VC81005C*B* 56,500 38,500 14.00 11.50 1,520 5586779 CHPF4860D6D*+TXV G*E80805C*B* 56,000 38,500 14.00 11.50 1,550 5586802 CHPF4860D6D*+TXV G*E81005C*B* 56,000 38,500 14.00 11.50 1,525 5586805 CHPF4860D6D*+TXV G*VC80805C*B* 56,000 38,500 14.00 11.50 1,520 5586808 CHPF4860D6D*+TXV G*VC81005C*B* 56,500 38,500 14.00 11.50 1,520 5586811 CHPF4860D6D*+TXV G*VC91155DXA* 56,000 38,500 13.00 11.00 1,550 5593118 CHPF4860D6D*+TXV A*VC950905CXB* 56,000 38,500 13.50 11.00 1,460 5621113 CHPF4860D6D*+TXV G*VC950905CXB* 56,000 38,500 13.50 11.00 1,460 5621114 CHPF4860D6D*+TXV A*VC950905DXB* 56,000 38,500 14.00 11.50 1,460 5621122 CHPF4860D6D*+TXV G*VC950905DXB* 56,500 38,500 14.00 11.50 1,460 5621123 CHPF4860D6D*+TXV A*VC950915DXB* 55,000 37,600 13.00 11.00 1,575 5621131 CHPF4860D6D*+TXV G*VC950915DXB* 55,000 37,600 13.00 11.00 1,575 5621132 CHPF4860D6D*+TXV A*VC951155DXB* 56,000 38,500 14.00 11.50 1,550 5621141 CHPF4860D6D*+TXV G*VC951155DXB* 56,000 38,500 14.00 11.50 1,550 5621142 CHPF4860D6D*+TXV A*VM960805CXB* 56,500 38,500 13.50 11.00 1,460 5621150 CHPF4860D6D*+TXV G*VM960805CXB* 56,500 38,500 13.50 11.00 1,460 5621151 CHPF4860D6D*+TXV A*VM960805DXB* 55,500 38,000 13.00 11.00 1,460 5621160 CHPF4860D6D*+TXV G*VM960805DXB* 55,500 38,000 13.00 11.00 1,460 5621161 CHPF4860D6D*+TXV A*VM961005DXB* 56,000 38,500 14.00 11.50 1,550 5621170 CHPF4860D6D*+TXV G*VM961005DXB* 56,000 38,500 14.00 11.50 1,550 5621171 CHPF4860D6D*+TXV A*VM961155DXB* 56,000 38,500 14.00 11.50 1,550 5621180 CHPF4860D6D*+TXV G*VM961155DXB* 55,000 37,600 13.50 11.00 1,550 5621181 CHPF4860D6D*+TXV A*EH800805C*A* 56,000 38,500 14.00 11.50 1,550 6944966 CHPF4860D6D*+TXV A*EH801005C*A* 56,000 38,500 14.00 11.50 1,525 6944968 CHPF4860D6D*+TXV AMEH960805CXA* 56,000 38,500 13.00 11.00 1,475 6944970 CHPF4860D6D*+TXV AMEH961005DXA* 56,000 38,500 14.00 11.50 1,500 6944972 CSCF4860N6D*+EEP 55,000 37,600 13.00 11.00 1,500 5589903 CSCF4860N6D*+MBVC2000**-1A*56,000 38,500 13.50 11.50 1,575 5589906 CSCF4860N6D*+MBVC2000**-1A*+TXV 56,000 38,500 14.00 11.50 1,575 5586690 CSCF4860N6D*+TXV G*E80805C*B* 54,500 37,400 13.00 11.00 1,550 5586829 CSCF4860N6D*+TXV A*VC80805C*B* 56,500 38,500 13.50 11.50 1,520 5589909 CSCF4860N6D*+TXV A*VC81005C*B* 55,500 38,000 13.50 11.00 1,520 5589912 CSCF4860N6D*+TXV G*E81005C*B* 55,500 38,000 13.50 11.00 1,525 5589933 CSCF4860N6D*+TXV G*VC80805C*B* 56,500 38,500 13.50 11.50 1,520 5589936 CSCF4860N6D*+TXV G*VC81005C*B* 55,500 38,000 13.50 11.00 1,520 5589939 CSCF4860N6D*+TXV GME950805CXA* 55,000 37,600 13.00 11.00 1,475 5589954 CSCF4860N6D*+TXV GME951005DXA* 55,000 37,600 13.50 11.00 1,500 5589957 CSCF4860N6D*+TXV A*VC950905CXB* 55,000 37,600 13.50 11.00 1,475 5621115 See Notes on Page 39. Product SPecificationS SS-GSX13 www.goodmanmfg.com 39 dimenSionS H W D Model Dimensions W”D”H” GSX130181E* 23 23 25¾ GSX130241D* 23 23 25¾ GSX130301B* 26 26 27½ GSX130361C* 29 29 28¾ GSX130361E* 26 26 27½ GSX130421B* 29 29 36¼ GSX130481B* 29 29 36¼ GSX130601B* 29 29 40 GSX130611A* 35½ 35½ 38¼ Outdoor Unit Indoor Units Cooling Ratings CFM AHRI #Coils/Air Handlers Furnaces Total¹ Sens.¹SEER² EER³ GSX13 0611A* (cont.) CSCF4860N6D*+TXV A*VC950905DXB* 55,000 37,600 13.50 11.00 1,475 5621124 CSCF4860N6D*+TXV A*VC950915DXB* 55,000 37,600 13.00 11.00 1,575 5621133 CSCF4860N6D*+TXV G*VC950915DXB* 55,000 37,600 13.00 11.00 1,575 5621134 CSCF4860N6D*+TXV A*VC951155DXB* 55,000 37,600 13.50 11.00 1,550 5621143 CSCF4860N6D*+TXV A*VM960805CXB* 55,500 38,000 13.00 11.00 1,460 5621152 CSCF4860N6D*+TXV G*VM960805CXB* 55,500 38,000 13.00 11.00 1,460 5621153 CSCF4860N6D*+TXV A*VM960805DXB* 55,500 38,000 13.00 11.00 1,460 5621162 CSCF4860N6D*+TXV G*VM960805DXB* 55,500 38,000 13.00 11.00 1,460 5621163 CSCF4860N6D*+TXV A*VM961005DXB* 55,000 37,600 13.50 11.00 1,550 5621172 CSCF4860N6D*+TXV G*VM961005DXB* 55,000 37,600 13.50 11.00 1,550 5621173 CSCF4860N6D*+TXV A*VM961155DXB* 55,000 37,600 13.50 11.00 1,550 5621182 CSCF4860N6D*+TXV G*VM961155DXB* 55,000 37,600 13.50 11.00 1,550 5621183 CSCF4860N6D*+TXV A*EH800805C*A* 54,500 37,400 13.00 11.00 1,550 6944974 CSCF4860N6D*+TXV A*EH801005C*A* 55,500 38,000 13.50 11.00 1,525 6944976 CSCF4860N6D*+TXV AMEH960805CXA* 55,000 37,600 13.00 11.00 1,475 6944978 CSCF4860N6D*+TXV AMEH961005DXA* 55,000 37,600 13.50 11.00 1,500 6944980 ¹ BTU/h ² Seasonal Energy Efficiency Ratio; Certified per AHRI 210/240 @ 80°F/ 67°F/ 95°F ³ Energy Efficiency Ratio @ 80°F/ 67°F/ 95°F Notes • Always check the S&R plate for electrical data on the unit being installed. • When matching the outdoor unit to the indoor unit, use the piston supplied with the out- door unit or that specified on the piston kit chart supplied with the indoor unit. • EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay Ahri rAtinGS (Cont.) Product SPecificationS 40 www.goodmanmfg.com SS-GSX13 WirinG diAGrAm — GSX130181e USE N.E.C. CLASS 2 WIRECOMPALTERNATE DOUBLEPOLE CONTACTOR ONLYIOT1MAINRAUX5SSRSA21RCCFSCT2CL1L2(IF USED)CHCFMAINAUXCC0140R00258-BBLYCLVJBCOLOR CODEBK --------------- BLACKBL --------------- BLUEBL/PK ---------- BLUE/PINK STRIPEBR --------------- BROWNOR --------------- ORANGEPU --------------- PURPLERD --------------- REDWH -------------- WHITEYL ---------------- YELLOWCONTROL BOXCOMPONENT CODEC --------------- CONTACTORCM ------------ OUTDOOR FAN MOTORCOMP -------- COMPRESSORHPS ----------- HIGH PRESSURE SWITCHIO -------------- INTERNAL OVERLOADLVJB ---------- LOW VOLTAGE JUNCTION BOXRCCF --------- RUN CAPACITOR FOR COMPRESSOR & FANSA ------------- START ASSISTSC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.OUTDOOR POWER SUPPLYSEE RATING PLATEWIRING CODEFACTORY WIRINGHIGH VOLTAGELOW VOLTAGEOPTIONAL HIGH VOLTAGEFIELD WIRINGHIGH VOLTAGELOW VOLTAGEIOCMYBL/PKYLCRSRDBKAUXMAINCOMPNOTE 1SCRDBLRCCFFCHERMYLYLYLBRRDPUYLRDSR521BKYLBLRDBLRDRDBKBKBKCT1L1T2L2RD SA(IF USED)NOTE 2EQUIPMENT GROUNDPUBRBKMAINAUXCMIOT1L1T2L2ALTERNATE DOUBLEPOLE CONTACTORNOTES:1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK AND INDOOR THERMOSTAT2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED.3) USE COPPER CONDUCTORS ONLY.BL/PKHPSBL/PKHPSBL/PKIOWiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring.⚠ WARNINGHigh Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.⚡ Product SPecificationS SS-GSX13 www.goodmanmfg.com 41 WirinG diAGrAm — GSX130(30-60)1B/C/e*Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring.⚠ WARNINGHigh Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.⚡USE N.E.C. CLASS 2 WIRECOMPALTERNATE DOUBLEPOLE CONTACTOR ONLYIOT1CM AIN RAUX5SSRSA21RCCFSCT2CL1L2(IF USED)CHCFM AINAUXCC0140R00015P-ABLYCLVJBCOLOR CODEBK --------------- BLACKBL --------------- BLUEBR --------------- BROWNOR --------------- ORANGEPU --------------- PURPLERD --------------- REDWH -------------- WHITEYL ---------------- YELLOWCONTROL BOXCOMPONENT CODEC --------------- CONTACTORCM ------------ OUTDOOR FAN MOTORCOMP -------- COMPRESSORIO -------------- INTERNAL OVERLOADLVJB ---------- LOW VOLTAGE JUNCTION BOXRCCF --------- RUN CAPACITOR FOR COMPRESSOR & FANSA ------------- START ASSISTSC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.OUTDOOR POWER SUPPLYSEE RATING PLATEWIRING CODEFACTORY WIRINGHIGH VOLTAGELOW VOLTAGEOPTIONAL HIGH VOLTAGEFIELD WIRINGHIGH VOLTAGELOW VOLTAGEIOCMYYLYLCRSRDBKAUXMAINCOMPNOTE 1SCRDBLRCCFFCHERMYLYLYLBRRDPUYLRDSR521BKYLBLRDYLBLRDRDBKBKBKCT1L1T2L2RD SA(IF USED)NOTE 2EQUIPMENT GROUNDUSE COPPERCONDUCTORS ONLYPUBRBKMAINAUXCMIOT1L1T2L2ALTERNATE DOUBLEPOLE CONTACTORNOTES:1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK AND INDOOR THERMOSTAT2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. Product SPecificationS 42 www.goodmanmfg.com SS-GSX13Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring.⚠ WARNINGHigh Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.⚡WirinG diAGrAm — GSX130(18-24)1d* 0140R00165 CCSC987654321987654321FCDEBAFCDEBATHE GOODMAN MANUFACTURING COMPANY,L.P.DRAWING TO BE INTERPRETED INACCORDANCE WITH ASME Y14.100TITLELABEL, WIRING DIAGRAM DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED.TOLERANCES:ANGLES ± 1.5 °.X ± .1.XX ± .03.XXX ± .015HOLES : ±.005TUBE CUT LG: ±.063DWN: GLENG: S. BADAM SCALE: NTSDATE: 03-26-10 CHK: D. MASSEY SHEET: 1 OF 1 DWG.NO.0140R00165 A SPECIAL CHARACTERISTICS: = 6SIGMA = CRITICAL CHARACTERISTIC = SIGNIFICANT CHARACTERISTIC COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABLE SECTION OF GOODMAN MSP 824.01 WORKMANSHIP STANDARD FOR FIT, FEEL, AND FINISH.CONFIDENTIAL PROPERTY OF THE GOODMAN FAMILY OF COMPANIES NOT TO BE DISCLOSED TO OTHERS, COPIED, OR USED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAND, ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT.ECN REV ZONEDESCRIPTION CHK DR DATE1004705A - INITIAL RELEASEGL 03-26-10USE N.E.C. CLASS 2 WIRENOTES:1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR THERMOSTAT.2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED.COMPALTERNATE DOUBLEPOLE CONTACTOR ONLYIOT1CMAINRAUX5SSRSA21RCCFSCT2CL1L2(IF USED)CHCFMAINAUXCC0140R00165 - ABLYCLVJBCOLOR CODEBK --------------- BLACKBL --------------- BLUEBR --------------- BROWNPU --------------- PURPLERD --------------- RED WH -------------- WHITEYL --------------- YELLOWCONTROL BOXCOMPONENT CODEC --------------- CONTACTORCM ------------ OUTDOOR FAN MOTORCOMP -------- COMPRESSORIO -------------- INTERNAL OVERLOAD LVJB ---------- LOW VOLTAGE JUNCTION BOXRCCF --------- RUN CAPACITOR FOR COMPRESSOR & FANSA ------------- START ASSISTSC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.WIRING CODEFACTORY WIRINGHIGH VOLTAGELOW VOLTAGEOPTIONAL HIGH VOLTAGEFIELD WIRINGHIGH VOLTAGELOW VOLTAGEIOCMYYLYLCRSRDBKAUXMAINCOMPNOTE 1SCRDBLRCCFFCHERMYLYLYLBRRDPUYLRDSR521BKYLBLRDYLBLRDRDBKBKBKCT1L1T2L2RD SA(IF USED)NOTE 2EQUIPMENT GROUNDUSE COPPER CONDUCTORS ONLYT1L1T2L2ALTERNATE DOUBLE POLE CONTACTOROUTDOOR POWER SUPPLYSEE RATING PLATEPUBRBKMAINAUXCMIOGR/YL------------- GREEN / YELLOWOTCHBKRDRDNOTES: 1. MATERIAL: 4 MIL WHITE FLEXIBLE VINYL WITH PRESSURE SENSITIVE PERMANENT ACRYLIC ADHESIVE AND A SEMI BLEACHED KRAFT RELEASE LINER, AS PER SPEC S4900065, TYPE A2. LABEL TO BE PRINTED ON A 9" X 6" FORMAT.BKOT ------------- OUTDOOR THERMOSTAT3) CRANK CASE HEATER FACTORY INSTALLED WHEN REQUIRED CH ------------- CRANKCASE HEATERGR/YL Product SPecificationS SS-GSX13 www.goodmanmfg.com 43 WirinG diAGrAm — GSX130611*Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring.⚠ WARNINGHigh Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.⚡USE N.E.C. CLASS 2 WIRECOMPALTERNATE DOUBLEPOLE CONTACTOR ONLYIOT1CM A INRAUX5SSRSA21RCCFSCT2CL1L2(IF USED)CHCFMAINAUXCC0140R00015P-ABLYCLVJBCOLOR CODEBK --------------- BLACKBL --------------- BLUEBR --------------- BROWNOR --------------- ORANGEPU --------------- PURPLERD --------------- REDWH -------------- WHITEYL ---------------- YELLOWCONTROL BOXCOMPONENT CODEC --------------- CONTACTORCM ------------ OUTDOOR FAN MOTORCOMP -------- COMPRESSORIO -------------- INTERNAL OVERLOADLVJB ---------- LOW VOLTAGE JUNCTION BOXRCCF --------- RUN CAPACITOR FOR COMPRESSOR & FANSA ------------- START ASSISTSC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.OUTDOOR POWER SUPPLYSEE RATING PLATEWIRING CODEFACTORY WIRINGHIGH VOLTAGELOW VOLTAGEOPTIONAL HIGH VOLTAGEFIELD WIRINGHIGH VOLTAGELOW VOLTAGEIOCMYYLYLCRSRDBKAUXMAINCOMPNOTE 1SCRDBLRCCFFCHERMYLYLYLBRRDPUYLRDSR521BKYLBLRDYLBLRDRDBKBKBKCT1L1T2L2RD SA(IF USED)NOTE 2EQUIPMENT GROUNDUSE COPPERCONDUCTORS ONLYPUBRBKMAINAUXCMIOT1L1T2L2ALTERNATE DOUBLEPOLE CONTACTORNOTES:1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK AND INDOOR THERMOSTAT2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. Product SPecificationS 44 www.goodmanmfg.com SS-GSX13 Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2014 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. ACCeSSorieS Model Description GSX13 018D* GSX13 018E* GSX13 024C* GSX13 024D* GSX13 030B* GSX13 036** GSX13 042B* GSX13 048B* GSX13 060B* GSX13 061A* ABK-20 Anchor Bracket Kit ^X X X X X X X X ABK-21 Anchor Bracket Kit ^X X ASC-01 Anti-Short Cycle Kit X X X X X X X X X X CSR-U-1 Hard-start Kit X X X X X X X X X CSR-U-2 Hard-start Kit X CSR-U-3 Hard-start Kit FSK01A¹Freeze Protection Kit X X X X X X X X X X LSK02A² Liquid Line Solenoid Kit X X X X X X X X X X TX2N4² TXV Kit X X TX2N4A² TXV Kit X X X X TX3N4² TXV Kit X X TX5N4² TXV Kit X X X X ^ Contains 20 brackets; four brackets needed to anchor unit to pad ¹ Installed on indoor coil ² Field-installed, non-bleed, expansion valve kit — Condensing units and heat pumps with reciprocating compressors require the use of start-assist com- ponents when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit.