HomeMy WebLinkAboutB14-0196 State Water Heater.pdfSELECT®SL POWER DIRECT VENT RESIDENTIAL GAS WATER HEATERS RESIDENTIAL Side-Mounted Taps for Recirculating Systems • Hot and cold “side taps” allow the Power Vent DV to be used for “combination” systems for water heating plus space heating, radiant floor heating or other applications requiring a recirculating hot water loop Plugs for recirculating taps are factory-installed PowerDirectVentDesign • Power Direct Vent residential gas models are FVIR Compliant and meet the ANSI Z21.10.1-CSA 4.1 standards • Two pipe “Closed-Combustion” system - draws combustion air from outside and vents to outside the home. Quiet, modular blower for power venting with 3” Schedule 40 PVC, CPVC or ABS piping. Energy Saving Hot Surface Ignition System 110/120 Volt Electrical System • Rating 3 amps or less, with 6 foot cord, standard 3-prong male connector Dual Magnesium Anode Rods • Provides extra protection against corrosion Brass Drain Valve Green Choice Burner ® • Reduces NOx emissions up to 33% and meets low NOx emission requirements of less than 40 ng/j PEXAN™ Diffuser Dip Tube • Helps reduce lime and sediment buildup, maximize hot water output • PEXAN cross-linked polymer withstands long-term exposure to temperatures up to 400oF Silencer™Heat Trap Nipples • Factory-Installed on all models. Helps prevent heat from escaping from the tank during standby periods. CSA International Certified ECO (Energy Cutoff) Maximum Hydrostatic Working Pressure 150 psi CSA Certified and ASME Rated T&P Relief Valve, Factory-Installed 6-Year Limited Tank and Parts Warranty FormoreinformationonSelect®SL contact: State Water Heaters 500 Tennessee Waltz Parkway Ashland City, TN 37015 1-800-365-0024 Toll-free USA www.statewaterheaters.com SRGSS03811 ® Code Compliance - All models meet the Federal Energy Efficiency Standards effective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of 1992 and the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. Also complies with the current editions of the B.O.C.A. National Codes, C.E.C., U.B.C., S.B.C.C., C.A.B.O. and the H.U.D. standards. • Durable, tamper-resistant brass drain valve Revised May 2012 • 247122_SRGSS03811.indd 1247122_SRGSS03811.indd 1 5/23/12 9:02 AM5/23/12 9:02 AM SELECT®SL — POWER DIRECT VENT RESIDENTIAL GAS WATER HEATERS RESIDENTIAL For more information on Select ®SL contact: State Water Heaters 500 Tennessee Waltz Parkway Ashland City, TN 37015 1-800-365-0024 Toll-free USA www.statewaterheaters.com SRGSS03811 © 2012 State Industries, Inc. Printed in U.S.A For complete information on limited warranties, consult written warranty or contact technical support at 1-800-365-0024. State Industries, Inc., reserves the right to make product changes or improvements without prior notice. MODEL NUMBER GALLON CAPACITY ENERGY FACTOR (EF) FIRST HOUR RATING 90°F RECOVERY RISE (GPH) BTU INPUT PER HOUR NAT/PROPANE BTU OUTPUT PER HOUR NAT/PROPANE DIMENSIONS IN INCHES APPROX. SHIPPING WEIGHT (LBS)A B C D E F G H GS6 40 YBPDT L 40 .60 70 41/37 40,000/36,000 30,400/27,360 57 48 1/2 21 15 8 42 17 42 224 GS6 50 YRPDT L5 50 .58 105 64 59 65,000/60,000 47,450/43,800 69 1/2 61 21 15 8 54 1/2 17 54 1/2 232 GS6 75 YRPDT L 75 .58 130 72/67 70,000/65,000 53,200/49,400 71 1/2 61 1/2 26 1/4 15 1/2 8 54 1/2 17 54 1/2 352 First hour ratings & recoveries are rounded to nearest gallon All models have 3/4˝ male inlet and outlet connections When ordering propane, change “Y” to “H” in the model number (Example: GS6 40 HBPDT L) Venting System Requirements 1 The water heater requires its own (separate) venting system. 2 Venting cannot be connected to existing vent piping or chimney. 3 Venting must terminate horizontally through side wall or vertically through the roof to the outdoors. 4 For venting, 3˝ Schedule 40 PVC, CPVC, ABS pipe can be used. 5 Horizontal runs must be secured at 3 1/2´ intervals and vertical runs secured at 5´ intervals. 6 Vent piping cannot under any circumstances be run downhill. 7 Horizontal runs require a minimum 1/8˝ rise per 5 feet. 8 Total vertical and horizontal runs cannot exceed 45´ with one elbow.* 9 To comply with ANSI Standards install vent piping so that it can be visually in- spected. 10 Power Direct Vent terminal shall terminate at least “A” below, “A” horizontally or “A” above any door, window or gravity air inlet into the building. “A” = 9˝ (50,000 BTUH input or less) “A” = 12˝ (over 50,000 BTUH input) 11 For model number GS6 50 YRPDT L5, 5´ of 3˝ ABS vent pipe is supplied and must be used for the first 5´ of the exhaust outlet vent system. 12 For model number GS6 75 YRPDT L, 5´ of 3˝ CPVC vent pipe is supplied and must be used for the first 5´ of the exhaust outlet vent system. *If more elbows are required, the venting distance must be reduced 5´ for every 90° elbow. •18˝minimum in all directions from any obstructions that may interfere with ventilation. •0˝clearance for 3˝ PVC, ABS or CPVC Schedule 40 piping from combustible surfaces. •12˝minimum from the ground and corners, 9˝ceiling overhangs. •The Power Direct Vent outlet terminal shall terminate at least 36˝above any forced air inlet located within 10 feet. •The Power Direct Vent outlet terminal of 50,000 BTUH input models or less shall terminate at least 9˝below, 9˝horizontally from or 9˝above any door, window or gravity air inlet into the building. •The Power Direct Vent outlet terminal of over 50,000 BTUH input models shall terminate at least 12˝ below, 12˝horizontally from or 12˝above any door, window or grav- ity air inlet into the building. •18˝ minimum from other natural draft (gravity) direct vent, power vent or power direct vent appliance inlet and/or outlet vent(s) when directly above or 135° to either side of center line. •24˝minimum from any appliance inlet and/or outlet vents when directly below or 45° to either side of center line. •The location selection must provide clearances for servicing and proper operation of the water heater. •Vent termination must not be within 3 feet of any items such as gas meters, gas valves or other gas regulating equipment. IMPORTANT! Combustion Air And Ventilation Requirements For Power Direct Vent Water Heaters Optional Circulating Loop Fittings Package, Part No. 9002604005 Circulating Loop Fittings Package includes assembled di-electric unions and full port shut-off valves. A standard hose-connect drain valve is included for field installation. Specially designed for use on side tap recirculating water heaters. Kit must be ordered through Service Parts Department at 1-800-821-2017. F 11.5˝min. from top of heater to center line of flue 3˝ VENT BA D G H C 4˝ E / OPTIONAL CONCENTRIC VENT KIT 3” DIAMETERVENT/EXHAUST 3” DIAMETER PVCINTAKE/COMBUSTION AIR 1 1/2”21 1/8” 4 1/2” DIAMETER1 3/16” 39” INSTALL IN ACCORDANCE WITH LOCAL CODES. OPTIONAL 3” PVC HORIZONTAL VENT KIT (Kit Number 9006475005) 247122_SRGSS03811.indd 2247122_SRGSS03811.indd 2 5/23/12 9:02 AM5/23/12 9:02 AM