HomeMy WebLinkAboutJandy cut sheet.pdf Jandyy Pro Series,Hi-E2a and Hi-E2412 Gas-Fired Heater Installation&Operation Manual Page 5
2.2 Heater Assembly and Preparation Locate the heater in an area where water leakage will
The Hi-E2 can be installed in a variety of ways,some of them not result in damage to the area around the appliance or
requiring preparation or assembly in the field.In all cases, to a structure.If forced to locate the heater where water
condensate tubing and fittings,which are provided with the leakage may cause damage,provide a suitable pan with
heater,must be connected and routed.Water connections are drain under the heater.This pan must not restrict air flow
provided on the right side of the heater but can be changed to or heater functions.
the left side by reversal of the water headers. In selection of a location,disposal of combustion
It is best to handle these preparations before the heater condensate must also be considered.The heater can
is in its final location.Instructions are provided in produce three gallons of condensate water per hour
subsequent sections of this document. under some operating conditions.Means to drain this
condensate must be available or special provisions,such
Installation at High Elevation as a condensate pump must be provided. See later section
on condensate disposal.
The Hi-E2 has a venturi-type combustion system which
does not require modification for operation at high
elevation. In this type of system,air and fuel gas density 2.4 Installation Clearances
changes are automatically compensated for,assuring Clearances between the heater and combustible material
proper air/fuel mixture.Heating capacity is reduced about must be per Table 1.
3 percent per 1000 feet(305 meters)above sea level.In Table 1. Installation Clearance Requirements.
general,efficiency at high elevation is equal to or better
than at sea level. Surface/Component Minimum Clearance
Inches (mm)
2.3 Heater Location Rear& Blank Side 2(55)
The Hi-E2 may be installed indoors or outdoors as outlined Piping Side 12 (305)
in later sections.When installed indoors,combustion Front 18(455)*
air will often be piped to the heater and this requirement Top- Indoors 6(150)
may affect the choice of location,see later section on air Top-Outdoors Open (See Note)
for combustion and ventilation.Both indoor and outdoor
installations require provision of means for disposal of Flooring Combustible
combustion condensate per section 2.8. Vent 0
Install the heater at least 5 feet(1.52 meters)from the •For Canada 24 inches(610 mm)clearance
inside wall of the pool or spa unless the heater is separated NOTE See Section 2.5 for outdoor installation requirements.
from the pool or spa by a five-foot(1.52 meter)high solid
These clearances are the minimum acceptable.Whenever
fence,wall or other permanent barrier. possible, larger clearances should be provided to assure
When pool equipment is located below the pool surface, adequate room for service operations.Note that gas piping
a leak from any component can cause large scale water must be provided through the left side of the unit and
loss or flooding.Zodiac Pool Systems, Inc. cannot be that the combustion air duct,when provided,also enters
responsible for such water loss or flooding or resulting through the left side. See later section on combustion air,
damage.Location of the heater below or above the pool and also the section on water piping.
deck affects operation of its water pressure switch. See Do not install the heater on carpeting or similar material.
sections on water piping and heater start-up for more
information about this.
2.5 Outdoor Installation
CAUTION Locate the heater in an open,unroofed area and maintain
When pool equipment is located below the pool the clearances shown in Table 1.Do not locate the heater
surface, a leak from any component can cause large below or adjacent to any doors,windows,louvers or
scale water loss or flooding.Zodiac Pool Systems, Inc. grates,etc.,which connect in any way with an inhabited
cannot be responsible for such water loss or flooding area of a building,even through another building such as
or resulting damage. a garage or utility room,see Figure 1. Do not locate the
ATTENTION heater below an outdoor deck,unless treated as an indoor
installation with adequate clearances and proper venting
Lorsque I'equipement d'une piscine est situs sous la surface to a location away from the deck.
de Peau,une fuite provenant de n'importe quel element If the heater is installed close to a structure,protect it from
peut causer une perte d'eau importante ou une inondation.
Zodiac Pool Systems, Inc.nest pas responsable des rain water runoff by means of gutters,roof water diverters
pertes d'eau,des inondations ou des evades causees par or similar measures.Do not locate the heater close to
une installation ou un entretien inadequat. irrigation sprinklers.Water from sprinklers may damage
controls and electronic components.
Jandy*Pro Series,Hi-E25 and Hi-E25R Gas-Fired Heater I Installation&Operation Manual Allinill Page 35
231/2" Y
111/18"--"11/18"--l' W 5"� 4l/18''..-65/8" Vent Collar
1 1
�. 1
o 0
00
00
0
--3 1.
,L/T�-'iJ,'i�
36
�„ 8-
341/16. • - c}; L____,,___,
00 l._/ '- 216/16"
00 , ,=
=O 166/8 , 1 0
=f=1 , ,=
10"
"U U LJ L1 i 1 "I ,
-£1/8"
Model With Input Shipping -36/8"--
No W Weight ...-138_,...
350 317/8 350,000 252 lbs.
Figure 41. Capacities and Dimensions.
Section 6. Replacement Parts
6.1 Ordering Information
To order or purchase parts for the Jandy Pro Series Hi-E2 pool and spa heater,contact your nearest Zodiac dealer or
distributor.Access the Zodiac web site at www.zodiacpoolsystems.com for the nearest service center.If it cannot supply
you with what you need,contact Zodiac Pool Systems,Inc.Technical Support Department at 800.822.7933.
NOTE To order the correct part,it is important that you state the model number,serial number and type of gas when applicable.
This information is on the rating plate inside the heater.
6.2 Parts List
Key Model ORDER Key Model ORDER
No. Description No. PART NO: No. Description No. PART NO:
MAINTENANCE AND SERVICE COMPONENTS WATER SYSTEM
Limestone Gravel 350 R0306200 13 Heat Exchanger Assy,Complete,Cu 350 R0303805
(condensate neutralizer) 13 Heat Exchanger Assy,Complete,CuNi350 R0523705
Combustion Air Filter 350 R0308000 14 Heat Exchanger Tube Assy,Cu 350 10839405
JACKET ASSEMBLY 15 Inlet/Outlet Header 350 R0303900
1 Base Panel 350 R0347105 16 Return Header 350 R0304000
2 Frame Support Assembly 350 R0301505 17 Gasket,Header 350 R0304300
3 Back Panel 350 R0347205 18 By-Pass Valve Assembly 350 R0304400
4 Left Side Panel 350 R0347300 19 Flow Control Cap 350 S0076700
5 Right Side Panel 350 R0347400 20 By-Pass Valve Gasket 350 R0011400
6 Temperature Control Panel Assy 350 R0347505 21 By-Pass Valve Spring 350 R0304500
7 Door 350 R0347605 22 By-Pass Valve Rod 350 R0304900
8 Inlet/Outlet Header Panel 350 R0347700 23 By-Pass Valve Disk 350 R0011500
9 Right Top Side Panel 350 R0347800 24 Flange&Gasket Assy,2"(2) 350 R0055000
10 Return Header Panel 350 R0347900 25 Flange,2" 350 10573500+
11 Front Kick Panel 350 R0348005 26 Flange Gasket,2" 350 S0078000+
12 Top Panel 350 R0348105 27 Flange Sleeve,2" 350 S0078200+
Jacket Hardware Kit(Note 1) 350 R0302100 28 Flange Bolt 350 F0031700
Internal Hardware Kit(Note 1) 350 R0302500 29 Flange Gasket 1 1/2-2" 350 S0078100+