Loading...
HomeMy WebLinkAboutBegin_Workflow - Review Comments - 07-17-2014_01-39-02.pdfBegin_Workflow ­ Review Comments ­ 07­17­2014_01­39­02 Review Cycle Department Markup Snapshot 2 Building File: A1.1 Site Plan.pdf ChangeMark: mhaeberle Description: B001 Comment: Show code compliance on plans 2 Building File: A1.1 Site Plan.pdf ChangeMark: mhaeberle Description: B002 Comment: Are they? Please clarify  2 Building File: A1.0 Cover Sheet.pdf ChangeMark: mhaeberle Description: B001 Comment: Show compliance on plans 2 Building File: A1.0 Cover Sheet.pdf ChangeMark: mhaeberle Description: B002 Comment: Whic windows are what u value/ Show on plans 2 Building File: A1.0 Cover Sheet.pdf ChangeMark: mhaeberle Description: B003 Comment: Engineer of record? Plans indicate responsiible for foundation only 2 Public Works File: A1.1 Site Plan.pdf ChangeMark: tkassmel Description: PW001 Comment: Show how drainage flows passed driveway. Provide an extension of concrete pan to match uphill pan or provide culvert, as necessary 2 Public Works File: A1.1 Site Plan.pdf ChangeMark: tkassmel Description: PW002 Comment: Show additional elevations on contours, and differentiate better between existing and proposed contours. 2 Public Works File: A1.1 Site Plan.pdf ChangeMark: tkassmel Description: PW003 Comment: Is driveway heated, if so a separate zone must be shown for area within ROW and 4' concrete pan must not be heated.