B07-0017
} TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD ~~-~ ~~u VAIL, CO 81657 970-479-2138 ~~--~lvi~`~-` \~' OBSITE AT ALL TIMES V~ ~- NOTE: THIS PERMIT MUST BE POSTED ON J ADD/ALT MF BUILD PERMIT Permit #: B07-0017 ~ << ~ ~ ~ ~~ ~~ Project #: ?? ~ "ZS ~ - O ~ O ~ Job Address.: 292E MEADOW DR VAIL Location......: MOUNTAIN HAUS #438 AND 440 Parcel No....: 210108228037 OWNER NORTHLAND HOLDINGS, INC 3100 OAK RD 210 WALNUT CREEK CA 94596 APPLICANT NEDBO CONSTRUCTION P.O. BOX 3419 VAIL CO 81658 License: 251-A CONTRACTOR NEDBO CONSTRUCTION P.O. BOX 3419 VAIL CO 81658 License: 251-A 02/08/2007 02/08/2007 02/08/2007 Status.....: ISSUED Applied...: 02/08/2007 Issued ...: 05/11/2007 Expires...: 11 /07/2007 Phone: 970-845-1001 Phone: 970-845-1001 Desciption: MOUNTAIN HAUS #438-REMODEL INTERIOR, NEW WALL, DRYWALL, KITCHEN, BATHS Occupancy: R-2 Type Construction: 1B Valuation: $325,000.00 Revision Valuation: ?? Total Sq Ft Added: 0 **********~~***~*************~*****~*****~*******~************~~**** FEE SUMMARY **~********************~***********~***************~~******* Building------> $2 , 253 .75 Restuarant Plan Review--> $o . 00 Total Calculated Fees--> $3 , 721.69 Plan Check---> $1, 464.94 Recreation Fee--------------> $0.00 Additional Fees----------> $0.00 Investigation-> $0.00 TOTAL FEES-------------> $3,721.69 Total Permit Fee---------> $3 , 721.69 Will Call-----> $3.00 Payments-------------------> $3 , 721.69 BALANCE DUE---------> $0.00 Approvals: Item: 05100 BUILDING DEPARTMENT 02/16/2007 jplano Action: CR F:\cdev\CHRIS\PERMIT.COMMENTS\B07-0017\B07-0017.DOC 05/03/2007 jplano Action: AP CORRECTIONS ADDRESSED Item: 05400 PLANNING DEPARTMENT 02/08/2007 BGIBSON Action: AP 05/01/2007 bgibson Item: 05600 FIRE DEPARTMENT 04/13/2007 mcgee be removed per IFC. Action: AP Action: DN Unused door must r Provide fire alarm and fire sprinkler plans via permits. Non-vented fireplaces are not approved. Delete from plan or revise to comply with code. Dryer vent (A 4) must meet IBC and IMC requirements. 04/18/2007 mcgee Action: AP 1. The Mountain Haus is an existing building that does not technically comply with existing code as to type of construction. The Fire Dept agrees with the Bldg Dept in that all work must conform to constriuction practices pertaining to Type 1B construction. 2. Fire sprinkler work must comply with NFPA 13 requirements and VFD standards. A sprinkler permit is required. 3. Fire alarm changes must be submitted via a fire alarm permit. 4. See notes from 04/13/07 and Bldg Dept comments from John Plano. Item: 05500 PUBLIC WORKS See Conditions page of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other o~inanc~f the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV~i~~i /1T~ NONE AT~479-21 ~6R/AT OUR OFFICE FROM 8:00 AM-4 PM. / / / / SIGNATU O NER OR CON O~,F~t ,HIMSELF AND OWNEF CONDITIONS OF APPROVAL Permit #: B07-0017 as of OS-11-2007 Status: ISSUED Permit Type: ADD/ALT MF BUILD PERMIT Applicant: NEDBO CONSTRUCTION 970-845-1001 Job Address: 292 E MEADOW DR VAIL Location: MOUNTAIN HAUS #438 AND 440 Parcel No: 210108228037 Description: MOUNTAIN HAUS #438-REMODEL INTERIOR, NEW WALL, DRYWALL, KITCHEN, BATHS Applied: 02/08/2007 Issued: 05/11/2007 To Expire: 11/07/2007 *~~**~:~*~*~*~*~*~***:x*~:*~******~*~*~*~**~*~**:x*Conditions: *~*~*~*~:***~:*~:*~:*~:*~*~*~:*~***~****:~*~*~~*~:**~ Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 14 (BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 40 (BLDG): (MFR/COMM) FIRE ALARM REQUIRED PER NFPA 72. Cond: CON0008678 ALL EXTERIOR VENTS/COVERS SHALL BE PAINTED TO MATCH THE EXISTING EXTERIOR WALL. Cond: CON0008920 ANY STAGING OR PARKING IN THE PUBLIC RIGHT OF WAY REQUIRES A PERMIT WITH THE PUBLIC WORKS DEPARTMENT TOWN OF VAIL, COLORADO Statement ***~********************~*~x~x**:x********~x~****~:**************~x******************************* Statement Number: 8070000688 Amount: $2,256.75 05/11/200704:14 PM Payment Method: Check Init: LT Notation: Nedbo / ck 31532 ----------------------------------------------------------------------------- Permit No: B07-0017 Type: ADD/ALT MF BUILD PERMIT Parcel No: 2101-082-2803-7 Site Address: 292 E MEADOW DR VAIL Location: MOUNTAIN HAUS #438 AND 440 Total Fees: $3,721.69 This Payment: $2,256.75 Total ALL Pmts: $3,721.69 Balance: $0.00 *******~*~****~~**********************************************~************~****:x*********** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 2,253.75 WC 00100003112800 WILL CALL INSPECTION FEE 3.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADOCopy Reprinted on 02 -06 -2013 at 11:34:45 02/06/2013 Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R070000142 Amount: $1,464.94 02/08/200701:29 PM Payment Method: Check Init: JS Notation: 31068 /NEDBO CONST ----------------------------------------------------------------------------- Permit No: B07 -0017 Type: ADD /ALT MF BUILD PERMIT Parcel No: 2101 - 082 - 2803 -7 Site Address: 292 E MEADOW DR VAIL Location: MOUNTAIN HAUS #438 AND 440 Total Fees: $3,721.69 This Payment: $1,464.94 Total ALL Pmts: $3,721.69 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- PF 00100003112300 PLAN CHECK FEES 1,464.94 ~ 0 APP ATION WILL NOT BE AC EPTED IF INCOMPLETE OR UNSIG ~' ~ ~ V 3 Project #: ~~ ~ Building Permit #: ~~ 970-479-2'149.{Inspections) '~ ~ TOWN OF VAIL BUILDING PERMIT APPLICATION Separate Permits are required for electrical, plumbing, mechanical, etc.! 75 S. Frontage Rd. Vail, Colorado 81657 CONTRACTORINFORMATION General Contractor: Town of Vail Reg. No.: Contact Person and Phone #'s: Email address: ~~~ f ~ ~ 1t,~,-~G, t ~"' ,,,t Fax #: 'tf~'~ ^ ~ Contractor Signature" ,z .! ~ ~+neen~ ~TC \/AI ~ inTin~ic CnR R1111 r11N(: PERMIT /l ahnr R Materials) BUILDING: $ 3 ~~~CjC~,~ L,v ELECTRICAL: $ ~ OTHER: $ PLUMBING: $ MECHANICAL: $ TOTAL: $ .c'.~~CaCx~ Gv ~_ _ .,____. ~a n__a__a c_~/_ i+....,.s., n.......-.-.,.-~. /1FF:..n ~~ ~7/1_Z9ft_RRdn nr vici'f ~niuiw aarrla-CnUnfV r:r)m / V/ 1 Q/Y~.I TT VV.•aM Va ~ ------ -- - - - - Parcel # _ Job Name:~~J,UCf~~z l~/v~~'.;~-~-v~-Y ecb~lur~'L Job Address:~v7/jJFi=~:~••~~ ~~' ~rj/~-~~/y/a Legal Description Lot: Block: Filing: ~ Subdivision:/}~t,,,J ,~~-~~fi ~Crz~'~, Owners NamPp~~, ~~ /~/f ~ Address: ,3cY.~, c`.~4ic,~~~AD ~n?f~ ~, Phone: Architect/Designer: Address: /'~>L ~_.~~` Phone: Engineer: Address: Phone: Detailed description of work: j%y/il~•:~r~L /-?,`, i 2r~~~ , ~+~ ~--z% r-~ ,q~.c~ ~ ~ ~"`~`~~- ~ l~'i •Tc,f-f~: ~ i Work Class: New () Addition ( ) Remodel ( Repair ( ) Demo ( ) Other ( ) Work Type: Interior Exterior ( ) Bot Does an EHU exist at this location: Yes ( ) No~~ Type of Bldg.: Single-family ( ) Two-family ( ) Multi-family Commercial ( ) Restaurant ( )Other ( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No/T e of Fire laces Existin Gas Ap liances Gas Los Wood/Pellet Wood Burnin No/T e of Fire laces Pro osed: Gas A liances Gas Los ~ Wood/Pellet Wood Burnin NOT ALLOWED Does a Fire Alarm Exist: Yes •) No ( ) Does a Fire Sprinkler System Exist: Yes ( No ( ) ******FOR OFFICE USE ONLY _~ _ p ~ s, Try a of Construction: Date Received: ~(`~~ ' ~~ ~~ ~ ~ ~~ Occupancy Group: ~ Accepted By: ~~ ~ ' ~ w~`, ~~ ~~~~ ' ~ 75 ~ ~ ~ ; ~ 2~s -~ ~~,,,r~ r ,~ , F:\cdev\FORMS\Permits\Building\building~permit.DOC Page 1 of 16 02/09/2005 .l,. ` ,~ Department of Community Deve%pment Building Safety and Inspection Services 75 South Frontage Road fail, Co%rado 81657 970-479-2138 FAX 970-479-2452 www. vailgov.com ~ ~~~Qm~ APR 2 7 2U01 TOWN f~FFAAIL BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS: TO: Contractor/Applicant Nedbo FAX/Email #: (970)845-9979 NUMBER OF PAGES: FROM: DATE: BUILDING PERMIT #: OWNERS NAME: SITE ADDRESS: OCCUPANCY GROUP: TYPE OF CONSTRUCTION: NUMBER OF STORIES: BUILDING AREA: Architect Shepard/Douglass DeChant proj# 0602 (970)949-5152 3 John Plano, Building Plans Examiner 02/16/2007 B07-0017 Sanchez 292 Meadow Drive #438/440 R-2 1B On the 4th floor Interior Remodel The documents submitted for this project have been reviewed for compliance with the 2003 International Building Code, 2003 International Residential Code, 2003 International Mechanical Code, 2003 International Fuel Gas Code, 2003 International Plumbing Code, 2003 International Energy Conservation Code and 2002 National Electrical Code as modified and adopted by the Town of Vail. The fo/%wing comments wi//need to be addressed prior to issuance of a bui/ding permit; For processing: • Please submit four complete sets of revised construction documents containing the reauested information with all plan revision items clouded or otherwise identified. • Please respond in writing to each comment by marking the attached list or creating a response letter Indicate which plan sheet detail specification or calculation shows the reauested information Please send revisions to the attention of the plans examiner with the building permit application number noted. • Please be sure to include on the resubmittal the engineer's or architect's "wet" stamp, signature, registration number and date on the cover page of any structural calculations, all structural details and structural sheets of the plans For commercial or multi-family projects all. sheets of the plans must be stamped. Buildin4 Deaartment Comments: The type of construction referenced on the plans is indicating Type 2A. The records in the town are referencing Type 2FR construction. The closest type of construction to matching that in the new codes is Type 1B. This will dictate the amount of fire-resistive protection for the building elements. If a reduction is to be allowed, a full code review of the existing construction will be required to be submitted for review. Please change the construction type. (IBC Chapter 6) 2 The Town of Vail requires engineer stamped mechanical, electrical and plumbing drawings for extensive remodel work within units of multifamily construction. Please provide drawings. 3 Provide a detail of the existing floor/ceiling assemblies. The one for the floor of the units should be the same as the ceiling of the units. Provide a listed 2 hour assembly for the existing conditions. (IBC Table 601) 4 The reflected ceiling plan does not show penetrations of can lights, bath fans or range hood. If the ceiling of the unit is part of the rated floor/ceiling then these penetrations will have to be shafted or a fire damper installed. (IBC 712.4) 5 Provide details on how the new plumbing is to be fire-stopped in the existing floor. 6 Provide details on how the new ceiling finishes are attached. (IBC 803.4) 7 Indicate that the new finishes applied will meet the appropriate flame spread. (IBC Table 803.5) 8 The existing door that is labeled ~~Not in Use" will have to be filled with materials that meet one hour construction, see later comment on exiting. (IBC 1016.1) 9 The existing door labeled °Switch Swing" is required to have a 20 minute rating. Any work on the door will require it to meet current code. Re-working afire-rated door will void the listing. This will have to be a new 20 minute rated door. Please change the drawings accordingly. (IBC Table 715.3) 10 There are wall types .indicated on the drawings. Provide the wall schedule. 11 There are 2 ~~existing chases", it appears that it houses the plumbing stack serving the kitchens above and below this unit. The chase in the east unit is shown in the middle of the new master shower. Show on the drawings how all existing piping, wiring, venting or anything else in that chase will be routed and still meet code. 12 The drawings are indicating an °Eco-Smart Non-vented Fireplace". The Town of Vail has amended the code to disallow non-vented fireplaces. Change the fireplace to a vented model or remove it. 13 Have the mechanical engineer show the venting of the new fireplaces. 14 The rooms without the required natural ventilation will require mechanical ventilation. Have the mechanical engineer address accordingly. (IBC 1203.1) 15 Show the fireplace vent, the bath fan and range hood terminations on the elevation drawings. .'16 This unit requires two exits. There are two reasons for this. The first is that the unit is over 2000 square feet, Table 1014.1 requires two exits when R occupancies have an occupant load over 10. With an occupant load factor of 200 square feet per occupant, the .unit will be above the 10 when it is over 2000 square feet. The other is the common path of travel is over 75' when measured from the most remote point in the unit, per 1013.3. You will find these two criteria will be the driving force for requiring 2 exits in an R occupancy governed by the IBC. Watch that if the existing door is used as the second exit it cannot be accessed through storage rooms (closets), bathrooms or bedrooms. 17 The Existing Main Level Floor Plan shows a window in bedroom #1. The new Main Floor Plan does not show a window. Is this window eliminated? 18 Suggestion; The guest shower is indicating a shower head pointed at the door of the shower. I have seen this application be problematic with the dual swing doors, as it will almost always leak past the door. The old uniform plumbing code disallowed this. The new code that is adopted is silent. No response is required, just a heads up. Please refer to the cover sheet for information on resubmitting plans. In order to avoid delays in issuance of a permit, please check all requested information is included with the resubmitted plans. Please submit revised plans as a complete set. Partial plan resubmittals will not be reviewed. John Plano I.C.C. Plans Examiner Town of Vail Building Safety and Inspection Services 970.977-6278 jplano@vailgov.com F•\cdev\CHRIS\PERMIT COMMENTS\B07-0017\607-0017.DOC ~ U~ Department of Community Deve%pment Building Safety and Inspection Services 75 South Frontage Road fail, Co%rado 81657 970-479-2138 FAX 970-479-2452 www. uailgov.com BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS: TO: Contractor/Applicant Nedbo FAX/Email #: (970)845-9979 Architect Shepard/Douglass DeChant proj# 0602 (970)949-5152 NUMBER OF PAGES: FROM: DATE: BUILDING PERMIT #: OWNERS NAME: SITE ADDRESS: OCCUPANCY GROUP: TYPE OF CONSTRUCTION: NUMBER OF STORIES: BUILDING AREA: 3 John Plano, Building Plans Examiner 02/16/2007 B07-0017 Sanchez 292 Meadow Drive #438/440 R-2 1B On the 4`h floor Interior Remodel The documents submitted for this project have been reviewed for compliance with the 2003 International Building Code, 2003 International Residential Code, 2003 International Mechanical Code, 2003 International Fuel Gas Code, 2003 International Plumbing Code, 2003 International Energy Conservation Code and 2002 National Electrical Code as modified and adopted by the Town of Vail. The fo/%wing comments wi//need to be addressed prior to issuance of a bui/ding permit; For processing: Please submit four complete sets of revised construction documents containing the reouested information with all plan revision items clouded or otherwise identified. • Please respond in writing to each comment by marking the attached list or creating a response letter Indicate which plan sheet detail specification or calculation shows the reouested information Please send revisions to the attention of the plans examiner with the building eermit application number noted. • Please be sure to include on the resubmittal the engineer's or architect's "wet" stamp, signature, registration number and date on the cover page of any structural calculations all structural details and structural sheets of the clans For commercial or multi-family projects all sheets of the plans must be stamped. ,> Buildin4 Department Comments: 1 The type of construction referenced on the plans is indicating Type 2A. The records in the town are referencing Type 2FR construction. The closest type of construction to matching that in the new codes is Type 1B. This will dictate the amount of fire-resistive protection for the building elements. If a reduction is to be allowed, a full code review of the existing construction will be required to be submitted for review. Please change the construction type. (IBC Chapter 6) 2 The Town of Vail requires engineer stamped mechanical, electrical and plumbing drawings for extensive remodel work within units of multifamily construction. Please provide drawings. 3 Provide a detail of the existing floor/ceiling assemblies. The one for the floor of the units should be the same as the ceiling of the units. Provide a listed 2 hour assembly for the existing conditions. (IBC Table 601) 4 The reflected ceiling plan does not show penetrations of can lights, bath fans or range hood. If the ceiling of the unit is part of the rated floor/ceiling then these penetrations will have to be shafted or a fire damper installed. (IBC 712.4) 5 Provide details on how the new plumbing is to be fire-stopped in the existing floor. 6 Provide details on how the new ceiling finishes are attached. (IBC 803.4) 7 Indicate that the new finishes applied will meet the appropriate flame spread. (IBC Table 803.5) 8 The existing door that is labeled ~~Not in Use" will have to be filled with materials that meet one hour construction, see later comment on exiting. (IBC 1016.1) 9 The existing door labeled °Switch Swing" is required to have a 20 minute rating. Any work on the door will require it to meet current code. Re-working afire-rated door will void the listing. This will have to be a new 20 minute rated door. Please change the drawings accordingly. (IBC Table 715.3) 10 There are wall types indicated on the drawings. Provide the wall schedule. 11 There are 2 ~~existing chases", it appears that it houses the plumbing stack serving the kitchens above and below this unit. The chase in the east unit is shown in the middle of the new master shower. Show on the drawings how all existing piping, wiring, venting or anything else in that chase will be routed and still meet code. 12 The drawings are indicating an ~~Eco-Smart Non-vented Fireplace". The Town of Vail has amended the code to disallow non-vented fireplaces. Change the fireplace to a vented model or remove it. 13 Have the mechanical engineer show the venting of the new fireplaces. 14 The rooms without the required natural ventilation will require mechanical ventilation. Have the mechanical engineer address accordingly. (IBC 1203.1) 15 Show the fireplace vent, the bath fan and range hood terminations on the elevation drawings. 16 This unit requires two exits. There are two reasons for this. The first is that the unit is over 2000 square feet, Table 1014.1 requires two exits when R occupancies have an occupant load over 10. With an occupant load factor of 200 square feet per occupant, the unit will be above the 10 when it is over 2000 square feet. The other is the common path of travel is over 75' when measured from the most remote point in the unit, per 1013.3. You will find these two criteria will be the driving force for requiring 2 exits in an R occupancy governed by the IBC. Watch that if the existing door is used as the second exit it cannot be accessed through storage rooms (closets), bathrooms or bedrooms. 17 The Existing Main Level Floor Plan shows a window in bedroom #1. The new Main Floor Plan does not show a window. Is this window eliminated? 18 Suggestion; The guest shower is indicating a shower head pointed at the door of the shower. I have seen this application be problematic with the dual swing doors, as it will almost always leak past the door. The old uniform plumbing code disallowed this. The new code that is adopted is silent. No response is required, just a heads up. Please refer to the cover sheet for information on resubmitting plans. In order to avoid delays in issuance of a permit, please check all requested information is included with the resubmitted plans. Please submit revised plans as a complete set. Partial plan resubmittals will not be reviewed. John Plano I.C.C. Plans Examiner Town of Vail Building Safety and Inspection Services 970.977-6278 jplano@vailgov.com F: \cdev\CHRIS\PERMIT.COMMENTS\607-0017\B07-0017.DOC a DOUGUS MIU.ER DEGwwT ARCHITECTS SHEPHERD RESOURCES INC f AIA POST OFFICE BOX 1624 AVON COLORADO 81620 T970 949 3302 F970 949 51 21 WWW.SRIARCHITECT. COM April 26, 2007 John Plano, I.C.C. Plans Examiner ~~ Town of Vail Building Safety and Inspection Services 75 South Frontage Road Vail, CO 8 1657 RE: SANCHEZ RESIDENCE REMODEL MOUNTAIN HAUS PROJECT # 0602 LETTER OF RESPONSE TO PLAN COMMENTS BUILDING PERMIT # B07-0017 Dear John, In response to the Plan Review comments dated 2- 16-07, please note the following changes that we have ~~ made to the drawings: I . Please refer to sheet A0. I for change to Type I B as indicated by revision cloud. 2. Please refer to attached stamped mechanical, electrical and plumbing (MEP) drawings. 3. Please refer to sheet A8. I ,Detail I , for a detail of the existing floor/ceiling assemblies. 4. Please refer to clouded note at top of sheet A5.0, and attached, stamped mechanical, electrical and plumbing (MEP) drawings. 5. Please refer to attached stamped mechanical, electrical and plumbing (MEP) drawings. 6. Please refer to sheet A8. I ,Details 2-4 for details as to how the proposed new ceiling finishes are to be attached. 7. The General contractor (Nedbo) will verify that the applied new finishes will meet the appropriate flame spread. " 8. The existing door has now been relocated to Susan's Office and will be replaced with a new 20-minute rated door. Please see note on A2.0 at Door I I I B. This door will match the existing entry doors. 1 O:\Client Files\2006 Projects\0602- Sanchez Remode~B Proj Admin\08 Agency Approval & ModelV~gency Approva~Plans Examiner\Revised per Plan Comments 04.26.07.doc 9. Please refer to sheet A2.0 at Door I 0 I A. We will replace the existing door with a new 20-minute rated door. The door is to match existing. 10. Please refer to sheet A0. I for walltypes/ systems. I I . Refer to attached stamped mechanical, electrical and plumbing (MEP) drawings. 12. Please refer to sheet A2.0 indicating that we have deleted the faux or "Eco-smart" fireplace. 13. Refer to attached stamped mechanical, electrical and plumbing (MEP) drawings. 14. Please refer to attached stamped mechanical, electrical and plumbing (MEP) drawings. 15. The faux fireplace has been deleted, so it does not require any flue venting. Please refer to attached stamped mechanical, electrical and plumbing (MEP) drawings for bath fans. The range is an electric re- circulating range thus not requiring any flu termination. Only the new dryer vent will pierce to the exterior and it is shown on sheet A3. I . 16. Two exits have been designed into this plan per your comments. See sheet A2.0, Doors I 0 IA and I I I B. 17. It was not eliminated intentionally. The window has been restored to the plan. 18. The shower head has been relocated. See clouded area in Guest Bath, Room 110, on Sheet A2.0 Please call if you have any questions. Wth Best Regards, Debra on ,Senior Project Manager Project Manager 2 O:\Client Files\2006 Projects\0602- Sanchez Remode(\B Proj Admin\08 Agency Approval & Model\Agency Approvaf\Plans Examine~Revised per Plan Comments 04.26.07.doc ~ LtS, lb. GYJYJ! -3. 1t3r1'I r iy~. r 1.7 r. li.~ ~~~ Depar[ment ofCommunlty Development Build/ng Safety and Inspecflon Services 75South Frontage Road l/ai/, Colorado 81657 970-479-2138 FAX 9711-~f79-2452 Wwrv. var'lgovcom BUILDING SAFETY ANp INSPECTION SERVICItiS PI.A)LV REVIEW COMMENTS: TO: Contractor/Applicant Nedbo FAX/Email #: (970)845-9979 NUMIBER OF PAGES: FROM: DATE; BUILDING P~RMIf #: OWNERS NAME: SITE ADDRESS: OCCUPANCY GROUP: TYPE OF CONSTRUCTION: NUMBER OF STORIES: BUILDING AREA: Architect Shepard/Douglass DeChant proj# 0602 (970)94-.~.'S~ j l2l 3 John Plano, Building Plans Examiner Oz/16/2007 B07-0017 Sanchez 292 Meadow Drive #438/440 R-2 1B On the 4~' floor Interior Remodel The documents submitted for this project have been reviewed for compliance with the 2003 International Building Code, 2003 International Residential Code, 2003 International Mechanical Code, 2003 International Fuel Gas Code, 2003 International Plumbing Code, 2003 International Energy Conservation Code and 2D02 National Electrical Code as modified and adopted by the Town of Vail. The fo/%wing caomments wi//need to be addressed prior to issuancie of a bui/diog permit: Fbr processing: Please submit four complete sets of revised construction documents containing the requested information with all plan revision items clouded or otherwise identified. • Please respond in wrifiing to each comment by marklna the attached list or creating a response letter. Indicate which plan sheet, detail,~ecification, or calculation shows the requested information. Please send revisions to the attention of the plans examiner_with the buildlnq permit application number noted. • Please be sure to include on the resubmittal the engineer's or architect's "wet" stamp, signature. realstration number and date on the cover page of any structura( calculations, all structural details and structural sheets of tJ~e plans. Fvr commercial or multi-famil~araiects all sheets of the plans must be stamped. :~ Building Department_Comments: i The type of construction referenced on the plans is indicating Type 2A. The records in the town are referencing Type 2FR construction. The closest type of construction to matching that fn the new codes is Type 16. This will dictate the amount of fire resistive protection for the building elements. Ifi a reduction is to be allowed, a full code review of the existing construction will be required to be submitted for review, Please change the construction type. (TBC Chapter 6) -2 The Town of Vail requires engineer stamped mechanical, electrical and plumbing drawings for extensive remodel work within units of multifamily construction. Please provide drawings. 3 Provide a detail of the existing floor/ceiling assemblies. The one for the floor of the units should be the same as the ceiling of the units. Provide a listed 2 hour assembly for the existing conditions. (IBC Table b01) 4 The reflected ceiling plan does not show penetrations of can lights, bath fans or range hood. If the ceiling of the unit is part of the rated floor/ceiling then these penetrations will have to be shafted or a fre damper installed. (TBC 712.4) 5 Provide details on haw the new plumbing is to be fire-stopped in the existing floor, +6 Provide details on how the new ceiling finishes are attached. (IBC 803.4) 7 Indicate that the new finishes applied will meet the appropriate filame spread. (IBC Table 803.5) 8 The existing door that is labeled "Not [n Use" will have to be filled with materials that meet one hour construction, see later comment on exiting. (IBC 10L6,i) 9 The existing door labeled "Switch Swing" is required to have a 20 minute rating. Any work on the door will require it to meet current code. Re-working afire-rated door will void the listing. This will have to be a new 20 minute rated door. Please change the drawings accordingly. (IBG Table 715.3) 10 There are wall types [ndicated vn the drawings. Provide the wall schedule, 11 There are 2 "existing chases'; it appears that it houses the plumbing stack serving the kitchens above and below this unit. The chase in the east unit is shown in the middle of the new master shower. Show on the drawings how all existing piping, wiring, venting or anything else in that chase will be routed and still meet code. ~~2 The drawings are indicating an °Eco-Smart Nan-vented Fireplace". The Town of Vai! has amended the code to disallow non-vented fireplaces. Change the fireplace to a vented model or remove it. 13 Have the mechanical engineer show the venting of the new fireplaces. 14 The rooms without the required natural ventilation will require mechanical ventilation. Have the mechanical engineer address accordingly. (IBC 1203.1) 15 Show tle~{,aee-mot, the bath fan and range hood terminations on the elevation drawings. r gyn. io. ~eie~r o- tom iru. r l;, r'..:~i.~ . 16 This unit requires two exits. There are two reasons for this. The first is that the unit is over 2000 square feet, Table x.014.1 requires two exits when R occupancies have an occupant load over 10. With an occupant load facfior of 200 square het per occupant, the unit will be above the 10 when it is over 2000 square feet. The other is the common path of travel is aver 75' when measured from the most remote point in the unit, per 1013.3. You will find these two criteria will be the driving force for requiring 2 exits in an R occupancy governed by the IBC. Watch that if the existing door is used as the second exit it cannot be accessed through storage rooms (closets), bathrooms or bedrooms. 17 The Existing Main Level Floor Plan shows a window in bedroom #1. The new Main Floor Plan does not show a window. Is this window eliminated? 18 Suggestion; The guest shower is indicating a shower head pointed at the door of the shower. I have seen this application be problemafic with the dual swing doors, as it will almost always leak past the door. The old uniform plumbing code disallowed this. The new code that fs adopted is silent. No response is required, just a heads up. Please refer to the cover sheet for information on resubmitting plans. In order to avoid delays in issuance of a permit, please ch~2ck all requested information Is included with the resubmitted plans. Please submit revised plans as a complete set. Partial plan resubmlttals will not be reviewed. John Plano I.C.C. Plans I~carniner Town of Vail Building Safety and Inspection Services 970.977-6278 jplano@vailgov.COm F: \cdev\C~IRIS\PE@~,g,SOMMENTS\B07-0oi ~\g07-0017. DOC R~I3 ERx ENGINEERING • COMFORT SYSTEMSf°I PO BOX 8610 • AVON, CO 81620 • Telephone 970-845-7910 Fax 970845-7522 • E-mail drader~raden:rgineering.com April 23, 2007 Ms. Debra Monroe ~,OQ REGisT Shepard Resources ~ •'' - ~ q,~•. F~ PO Box 1624 q~l' ~F~' Avon, CO 81620 / RE: Power Requirement Report for the Sanchez Residence Mountain Haus, Units 438 & 440 Vail, CO 81657 REI Job#: 7020.00 Ms. Monroe, Based on the diagrams received from your office dated March 6, 2007 and additional communications, we find that the proposed electrical modifications to the subject units that will have an effect on respective electrical loads are as follows: 1. Add in-floor radiant heat (Est. 91 sq. ft. for master & guest bathrooms): Load Impact: + 1109VA 2. Add a steam shower to the master bathroom: Load Impact: + 6032VA 3. Add a washer & dryer: Load Impact: + 7532VA Calculating the load for this 2030 square foot area in accordance with NEC (2005) Art 220.40 we fmd that the net calculated load for the 120/208V lph 3w service feeder is 102A. This includes a washer, dryer, oven, steam shower and in-floor radiant heat. 2030 sq ft @ 3VA/sf ..............6090 VA 2 kit circuits ...........................3000 VA Laundry circuit .......................1500 VA SUBTOTAL... 10590VA First 3000 VA @ 100%.........3000 VA Balance @ 35% .....................2657 VA Dryer ..................................... 5500 VA Range .....................................4000 VA In-floor radiant heat ...............1109 VA Steam shower .....................6032 VA TOTAL.......22298VA / 208V =107A Ms. Debra Monroe Page 2 of 2 From our site observation, we found that the size of the existing services, circuit breakers, and associated incoming feeders for Units 438 and 440 are 90A each. The panel currently located in Unit 440 is a General Electric model TLM1612S Loadcenter with a total of 16 single-pole circuit-breaker spaces. However, this panel must be relocated from its current position because this space will become a closet. According to your documents, you have made provisions for a new panel location behind the new (relocated) door. We recommend that you remove the internal bussing and circuit breakers from the existing panel and use its cabinet as a splice box to extend the feeder, grounding, and required existing branch circuit conductors to the new location for the panel. The splice box must have an accessible cover. Furnish, install and connect a new 24-pole 120/240V lph, 3w ladcenter with minimum 100A bus and the required circuit breakers for reconnection of the existing branch circuits being re- used and the installation of new branch circuits for a steam generator (2P, 40A, GFCI) and in- floor radiant heating (1P, 20A, GFCI). The panel currently located in Unit 438 is a Siemans model G3040ML1200 Loadcenter with a total of 30 available single-pole circuit-breaker spaces. Sixteen of these 30 spaces are currently being used for existing circuits. In order to facilitate the installation of the new circuits as identified above, the following modifications shall be implemented: 1. Install a 2-pole, 40A GFCI circuit breaker for the steam generator in Master Bathroom. 2. Install a 1-pole, ZOA GFCI circuit breaker for the addition of in-floor radiant heat in Master and Guest Bathrooms. 3. Install a dedicated 1-pole 20A circuit breaker /receptacle for the addition of the washing machine. 4. Install a 2-pole, 30A circuit breaker for the addition of a clothes dryer. NEC 230.2 requires one electrical service per single residence. We have requested and received a written approval from the serving utility, Holy Cross Energy, and a verbal agreement from the Town of Vail Electrical Inspector for an exception to this section of the code. In cooperation with these entities and for the safety of maintenance and emergency services personnel, the electrical contractor must install engraved nameplates at each service disconnect that clearly identifies each disconnect as being one of two service disconnects for this unit. In addition, please have your electrical contractor bring devices and verify grounding, circuits and other electrical features of this residence and bring it up to date in accordance with the latest adopted edition of the National Electrical Code. Please contact me if you have further questions. F`e~~~ully submitted, - ~..~~~ Pete Swallow RARER ENGINEERING, INC. 970-845-7910 (ext. 117) petes ,raderengineering.com .~ ~ RAI~~Rx ~~* ENGINEERING • COMFORT SY5TEMSFI PO BOX 8610 • AVON, CO 81620 • Telephone 970-845-7910 Fax 97045-7522 • E-mail drader@raderengineering.com Date: 4/11/07 Conversation. with: Stan Hahn By: Company: Town of Vail -Elec. Insp. Phone #: Pete Swallow 970.479.2147 The following was discussed: Mr. Hahn returned my call to discuss the NEC 230.2 requirement of a single service per residence. We have requested the use of the existing two services for the Sanchez Residence as is. He clearly stated that this is not an issue with him as long as it is okay with Holy Cross Energy. CONFERENCE RECORD Job #: 7020.00 Job Name: Sanchez Remodel APR-?3-2007 08=10 .- HCE No. Glenw//ood Vail /'~o+~~=r JAS RADER ENGINEERING S ~~ ~~ ~~~ t~cc~p-s-~o~. ~~ [ s~ ot~ ~a~.~~ RESIDENTIAL- LOAD INFORMATION AND METFR LOCATION FORM ~{ (continued) 970 aa5 7622 P.02i0~ 52-5 location. ~Al~'T y~~ err ~.~ cL.,,, ~ ~~ Engineer ~ } Date ~Zd-~~~ ~'i I '~' NAME(App{{cand: ~~A1 ~~EZ t2~s>aonl~'E Eldg. Permit; No /Yea ~ NAME (Billing): HCE Member: No / Yes LLL//J ADDRESS (Billing): Phone (Home) ` / Phone (Business) LOCATION: Within City limits? 1Vo /Yes Cloy of ~( a.i ~ ' 5UBOIVISION ,LOT. .BLOCK, Fll.{NG, STREFrADDRE55 ~~ 2 .Fir /Gt£dAD1~/ I,~lt/y,~' ' NAME OF HOLY CROSS ENERGY ENCINEI;R CONTACTED %Z~~ l i.~f ~a~U ~ Anticipated Electric Service Dales: Temp. Const. ~ Permanent Secondary voltage: / 2~ ~ volts Phase 1 Secondary Wlre Size Meter Lacatlon; Pole House Pede$tal Distance (Tratnsformer to meter) (ft) Lam- ~ AiN Eov~nnErrr' IC'6L~h iN •SF-~nE~Y umbers on face oftransformer Z00 amp or less, self-contained meter socket /~ Fuse Slze 400 Amp (320 amp continuous duq,) self-contained meter socket, Breaker size 90 ~ SEF1YlCE REQUESTED: Number of Dw/ellings New Remodeled / Full Time Seasonal CT's Require 7 House (sq, ft) Trailer (size) Other Z(a~. IQEeS: dr~~ Flo be e~efr~..,~:^./ dv ELECTRICIAN: /~le c/6u Ci, nsf-'.rc'fien Phottie g7y. 8N5: /Ua ELECTRIC LOAD INFOftb+lAT10Rl: Lighting,~~kW Range: Elecsrlc kW each (Number l or Gas Clothes Dryer: Electric kW each (Number ) or Gas Heat: Electric - kW (Type 1, Natural Gas f /Propane Electric Neat Zone Control: 1~/Yes (Number of Zones Water Heater. Elear)c "' kW each (Number ,Natural Cas/Propane OtF+er MaJor Electric Loads Snowmelt/Drive & walkway ~ -' (kw), G kW Gutter heat tape ~ (kW), C~ kW ,C+rA,~ C~ en e.~3~~ r ~ ~ (ktr~, c~ kw Estimated. Maximum DemanC~(NEC) 2~- 3~ ~ kW Service Size ~r~7 (amps)`` .~~~ aao~~a ..~. 2 S~w,c6s/F~,~~,2,5 )ob w/O # Trans Ca # ~ ~ln~ w 3 X00 ~~A p~Y 1 X20 ~ ~~~ d ~~6 VIV ~~~~~~ ~~(~)a`l A~f1u uiur~,• ~ ~nn~ ~~~ .., APR-~3-2097 0°~10 RAAER ENGINEERING 97@ 8a5 7522 P.03i@5 REMARKS and/or Request for "Guidebook" exceptran per°Appendix. D for Section: ~~~ o~~ C~. 1Uvf~-t ~~ ~~ .~rF~~ Ce S .~ ~-c .~ _ , d /.~ k ~ ~d /l. ~~ r-~ .- ,. c ~ _ ~.~ .n nL ~ 40 ~ / ~2t _ / e wry :a~ Vey . ` 7fi(5 form may be faked to the ayproprfate Noly Crass Energy Qffilce: AVON = 949=4566 GEENWOQD SPRINGS - 9d -5465 After this harm is accepted as complete':~nd the new service ha.9 been ~inspecttd~ by the alettrlcal inspector, the appropriate Noly Cross Energy office must be cvntacted~bY'tho owner to request a connecC ,4vdn = 949-5892 ~ ~ Glenwood Springs ~ 9Q5-5491 1 certifjr,that the above infotmatlon~Ts correct and~~that 1 have read the attached "Cand-t-ons of Resldendai Service" ~ un land ~thenr. ~ . ~ 07 ~ ,...~-~~ _ Date oFAppllcagon) Customer signature) ' to/zo~aa 4 ti/Z ~d bl6 '0~! A~}la~la ecnv~ i,nu ~~~~~L•, ,~~~ .,, „ APR-13-2007 0B.~10 RRDER ENGINEERING 970 S45 7522 P, 0~ti05 . ~ H~IY CR~nSS ENERGY RESIDENTIAL -LOAD INFORMATION AND METER LOCATION FORM (continued) rV1DUviCa:~n ~uy$ 1 SITE SKETCH tilt d til6 0~ A9~3N3 SSO~a h~~H WHG~,1 inn~~c~•v~~ On the space provided above please sketch the stlucture site including j+,~Qtth rrow, roads, drfvewaysl sidewalks and Drop,osed meterlocatlon(s). 5~c~~ ~~ Uy~,~, y~g l~'~I.a~wl-=-:r 1{rte Physical address of project: 2~ 2 ~. N'~'A'~6-~ v~[ y~ U~ ~~, Ct~ ~ I (,!~~ .ziTe~oo 5 APR-13-2007 0S~17, RADER ENGINEERING • ~ ` J 97@ S45 7522 P.@505 Appendix D EXCEPTIC?~N~REVISION FORM FOR HOLY CROSS ENERGY CONSUMER SERVICE FACILITIES METERING AND USE "GUIDEBOOK" Use this form when requesting exceptions or changes to tfie Holy Cross Energy "GUIDE1300K. Please print leg[bly or type. ' 1 seek exception to she following sectlonEs): y~ S F-~-V~C-ES t seek revision to the following section(s); This section is responsible for the following problernEs): V S . 2 S ~2v~ GES Legal description of property ~ av ~•ka:• ~. ~ ~ s 2.4 tL. ~.. I -~;SA 4Joln/ ~rz.~ ~. d> !dJ -~ ~f 3~ y yb I reCIUESt l;he follOWing eXCeption/Change (perskctch an ravcr:e sldc of aa~a atcacAed 61uoprlnu or cicterohlc tilt): 2~Qv~s~ s~~• 4a, 3, be ~ iw~lO~'e~~'~d_ Explain how this practice will maintain/improve safety and reliability: COtM~JIN-~1(„ Z S G-l1-V ~GF~ 1~1T7~ ~,.- f~l ~~-~- O1J~C.L'.dp0 '/~};~S1NG C.~ ~E'i2t31C~, ~•-~- 1 ~ r~lo'1~ ' ~2AcT~ G-4 c... 'T~ f~ U N fit/ E'er 5~~-Vl CE Cd~uU v~.T~,~-S t! 1° ~- FL(5~.~ '~l-\~E w ~ ~~ atrt' ~~ ~1 ~ Nt-D~6~ l~ ~~v Go~a~ Submirt~ Address E-mail: Deliver to: Holy Cross Energy Mail to: Holy Cross Energy Attention: Manager of Eleccrtc Operations Attn: Manager of Electric Operations 399 Highway 82 P•O. Box 2150 Glenwood Springs, CO 87 601 Glenwood Springs, CO 8] 602 ~««HOIY CROSS ENERGY USE ONLY»»> The at~.ove described exception/change is hereby approved as noted. HOL R`U"~ EN RG BY; Title ~~~~ Date Approved; ~~ ~~ \ ~/~ d b~b ~~ a~)IaAla CCt~u~ i~ni~ l'OTAL P.05 '~C]~11' !'~.~1 Covered Bridge February 01, 2007 Design Review Board (DRB) Town of Vail Dept. of Community Development 75 South Frontage Road Vail, CO 81657 Regarding: Interior remodeling plans, Units 440 & 438 Dear TOV, The Mountain Haus Home Owners Association has given authorization for units 440 & 438 to seek approval from the TOV for their interior remodeling requests. Regards, ~~ a.,~'~-- St ve Hawkins General Manager Mountain Haus 292 East Meadow Drive, Vail, Colorado 81657 * 970/476-2434 * 970/476-3007 www.mountainhaus.com * e mail: info@mountainhaus.com * For Reservations: 800/237-0922 u nn v t ~~ V~ 1~ i ASBESTOS TESTING REQUIREMENTS THE TOWN OF VAIL AND STATE OF COLORADO DEPARTMENT OF PUBLIC HEALTH REQUIRE ASBESTOS TESTING ANYTIME WHEN MORE THAN 160 S.F. OF MATERIAL WILL BE DISTURBED OR REMOVED. AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION FOR ALL REMODEL, ADDITION OR OTHER PROJECTS INVOLVING ANY DEMOLITION OR REMOVAL OF BUILDING MATERIALS THAT MAY CONTAIN ASBESTOS. BUILDINGS CONSTRUCTED AFTER OCTOBER 12, 1988 THAT HAVE NO ASBESTOS CONTAINING MATERIALS ARE EXEMPT. A COPY OF THE REPORT MUST BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION • I have included the asbestos test and report with my building permit application applicant signature OR date • I certify my project will not disturb or remove more than 160 s.f. of building material. The construction plans submitted with my application clearly indicate this information. (This will be verified during plan review, and will delay your project if found to be inaccurate) applicant signature OR date • The building was constructed after October 12, 1988. The date of construction was original construction date ~~ ~~ F:\cdev\FORMS\Permits\Building\building~ermit.DOC Page 4 of 16 02/09/2005 ~ I44y Nedbo Construction P. O. Box 3419 Vail, CO 81658 970-845-1001 fax 970-845-9979 9/18/07 Mr. Charlie Davis Town of Vail Building Department 75 S. Frontage Road Vail, CO 81657 Re: B07-0017 Nedbo Construction is requesting an extension of the above captioned building permit. Due to a limited construction period at the Mtn. Haus, we will not be commencing construction until late April of 2008. Roland Kjesbo, President Nedbo Construction ~ ~C~C~~MC~ D SEP 18 2007 TOWN OF VAIL .: CONSTRUCTION Town of Vail Community Development Re: B07-0017 Please transfer building permit # B07-0017 to Boles Construction. Nedbo Construction Roland Kjesbo President ~'^^"~ f ~,~ off„t e~,~ -~~~; D~ - ~ ' !A! ~ ~y For Mailing: ~ ~ ' ~ ~~ PO Box 3419 ~`~ ~ ~'t Vail, CO 81658 ~v~g ~~ ~~' , . , ti ': ~ For Delivery & Shipping: "" ,_ 40690 HWY 6 & 24 Suite D Eagle-Vail, CO 81620 970-845-1001 FAX.• 970-845-9979 RA ICE Rz ENGINEERING ~ COMFORT 5Y5TEM5M PO BOX 8610 • AVON, CO 81620 • Telephone 970-845-7910 Fax 97045-7522 • E-mail dreder~rederengineering.com Apri123, 2007 ~-- Ms. Debra Monroe Shepazd Resources PO Box 1624 Avon, CO 81620 c~(rf-( S ,~C ~~r- d~K- RE: Power Requirement Report for the Sanchez Mountain Haus, Units 438 & 440 Vail, CO 81657 REI Job#:7020.00 Ms. Monroe, Based on the diagrams received from your office dated March 6, 2007 and additional communications, we find that the proposed electrical modifications to the subject units that will have an effect on respective electrical loads are as follows: 1. Add in-floor radiant heat (Est. 91 sq. ft. for master & guest bathrooms): Load Impact: + 1109VA 2. Add a steam shower to the master bathroom: Load Impact: + 6032VA 3. Add a washer & dryer: Load Impact: + 7532VA Calculating the load for this 2030 squaze foot azea in accordance with NEC (2005) Art 220.40 we find that the net calculated load for the 120/208V lph 3w service feeder is 102A. This includes a washer, dryer, oven, steam shower and in-floor radiant heat. 2030 sq ft @ 3VA/sf ..............6090 VA 2 kit circuits ...........................3000 VA Laundry circuit .......................1500 VA SUBTOTAL... 10590VA First 3000 VA @ 100%.........3000 VA Balance @ 35% .....................2657 VA Dryer ..................................... 5500 VA Range .....................................4000 VA In-floor radiant heat ...............1109 VA Steam shower .....................6032 VA TOTAL.......22298VA / 208V = 107A Ms. Debra Monroe Page 2 of 2 From our site observation, we found that the size of the existing services, circuit breakers, and associated incoming feeders for Units 438 and 440 are 90A each. T'he panel currently located in Unit 440 is a General Electric model TLM1612S Loadcenter with a total of 16 single-pole circuit-breaker spaces. However, this panel must be relocated from its current position because this space will become a closet. According to your documents, you have made provisions for a new panel location behind the new (relocated) door. We recommend that you remove the internal bussing and circuit breakers from the existing panel and use its cabinet as a splice box to extend the feeder, grounding, and required existing branch circuit conductors to the new location for the panel. The splice box must have an accessible cover. Furnish, install and connect a new 24-pole 120/240V lph, 3w loadcenter with minimum 100A bus and the required circuit breakers for reconnection of the existing branch circuits being re- used and the installation of new branch circuits for a steam generator (2P, 40A, GFCI) and in- floor radiant heating (1P, 20A, GFCI). The panel currently located in Unit 438 is a Siemans model G3040ML1200 Loadcenter with a total of 30 available single-pole circuit-breaker spaces. Sixteen of these 30 spaces are currently being used for existing circuits. In order to facilitate the installation of the new circuits as identified above, the following modifications shall be implemented: 1. Install a 2-pole, 40A GFCI circuit breaker for the steam generator in Master Bathroom. 2. Install a 1-pole, 20A GFCI circuit breaker for the addition of in-floor radiant heat in Master and Guest Bathrooms. 3. Install a dedicated 1-pole 20A circuit breaker /receptacle for the addition of the washing machine. 4. Install a 2-pole, 30A circuit breaker for the addition of a clothes dryer. NEC 230.2 requires one electrical service per single residence. We have requested and received a written approval from the serving utility, Holy Cross Energy, and a verbal agreement from the Town of Vail Electrical Inspector for an exception to this section of the code. In cooperation with these entities and for the safety of maintenance and emergency services personnel, the electrical contractor must install engraved nameplates at each service disconnect that clearly identifies each disconnect as being one of two service disconnects for this unit. In addition, please have your electrical contractor bring devices and verify grounding, circuits and other electrical features of this residence and bring it up to date in accordance with the latest adopted edition of the National Electrical Code. Please contact me if you have further questions. F:e~apect~ully submi ed, ~~..~- Pete Swallow RADER ENGINEERING, INC. 970-845-7910 (ext. 117) netesna,raderen ineering_com RAL~- ~: ~z ~` ~ ENGINEERING • COMFORT SY5TEMSM PO BOX 8610 • AVON, CO 81620 • Telephone 970-845-7910 Fax 970-845-7522 • E-mail drader@raderengineering.com Date: 4/11/07 Conversation with: Company: Stan Hahn By; Town of Vail -Elec. Insp. Phone #: Pete Swallow 970.479.2147 The following was discussed: Mr. Hahn returned my call to discuss the NEC 230.2 requirement of a single service per residence. We have requested the use of the existing two services for the Sanchez Residence as is. He clearly stated that this is not an issue with him as long as it is okay with Holy Cross Energy. CONFERENCE RECORD Job #: 7020.00 Job Name: Sanchez Remodel .~ APR-? 3-2007 08 ~ 10 ~.. _ _ NCf; No, _ Glenwood 1[ `/ Vail /~DiJyil~t:n y~.~5 ~/ 23- t ~ RADER ENGINEERING S~~ ~~ ~C~~ ~~~~o~ ~~~S~o~ F~~~~ RESIDENTIAL-LOAD INFORMATION AND METER LOCATION FORM .~ (continued) NAME (Appl(caat): ~i~ /~ ~ ~ E Z 12ES ~ D onl~~' NAME (Billing): ADDRESS (Billing): 970 845 7522 P.02i05 52-5 Location. ~ ,ry `T~ y~ ~LrYr ~.~ cL.,,, ~ ~~ Engineer ~ } Date y 2~ 1 ~ EIOg. Permit: No /Yes HCE Member: No / Yes o ~~ Phone (Home) / Phone iBuslness> LOCATION: Within City limits? No /Yes Clty of Y ~-1 SUBDIVISION ,LOT .BLOCK, FILING, STREET ADORES5 2°~ Z- ~~ /y£dAa1~ ~ ~ jV,+/' ' NAME OF HOLY CR055 ENERGY ENGINEER CONTACTED %~G-~~ (aia> ~dHt~.~ SERVICE REQUESTED: Number of Dwellings lVew Remodeled ~ Full Time Seasonal Anticipated Electric Service Daias: Temp. Const, Permanent Secondary voltage: l 2~ ~ volts Phase ~ Secondary Wlre Size Meter Lacatlon: Pele House Pede=ta] Distance (7ratnsformer to meter) (fta L.,+-•~'~-Aini Eov~pnbwr l~6tvY~ ~N •56inE.^.~ umbers on face oFuansformer Z00 amp or less, self-contained meter socket / fuse Slze a00 Amp (320 amp continuous duty,) self-contained meter socket Breaker size 901 G?'s Require 7 House (sq, fv Trailer (size) Other __2~.~ ~ ~e5% ELECTRICIAN: ll~e crr6 u ~ nSf-'rcf-ai7 Phone g7d• 8y5 % /Ua ~ ELECTRIC LOAD INFOKDIATION: Llghti'ng ._.~,,Q~, kW Range: Electric kYV each (Number , ) or Gas Cloches Dryer: Electric kW each (Number ) or Gas Heat: Electric - kW (type ), Natural Gas ~ /Propane _.__,___.. Electric Neat Zone Control: V /Yes (Number of Zones ) Water Heater. Electric kW each (Number ,Natural Gas/Propane Otf+er MaJor Electric Loads Snowmelt/Drive & Walkway ® -" (kw), C~ kw Gutter heat tape ~ (kW], ~ kW 2~- 3~ ~ kw Service Site _ ~ Estimated Maximum Demana•~P1EC) .~ (amps) )ob W/O # Trans Ca # ~ o~n~ V~ 3 ~~ ~~A aosY 1 ~~.o~ APR-~3-2097 0°~10 RADER ENGINEERING 970 8a5 7522 P.03i05 EtEMARKS and/or Request fo'r "Guidebook" exception per°Appendix. D far Section: ~~G o?~ ~ • .~" ~v ~~ ca~ ~r~. Ce ~ .~ fre r~lo,~r ~~A~ ~~G~ ~~ s ~~ ~~ wv ~l u~ This form maybe faxed to the appropriate Noly Crass Energy cFfice: AYON =9+49x{566 GEENWOOD SPRINGS - 9~A -5465 After this farm Es accepted as tomplcte and the new service ha.9 been~inspected•by the elettrlcal ir'speaor, the appcopriate Holy Crass Energy office trust be contasted•bY'Che ownor to request a connect: ,4von ~ 949-5892 ~ Glenwood Springs -- 945-5491 1 certifjr that the above informat~on~ls correct and~~that 1 have read the atta+~hed "Condit-ons of Residential Service" ~ un tand them. . bate oFAppllcagon) Cusiomer5lgnature) ' ~0~2o~oa 4 1,~7 ~ ~~..,,. ~ v~1- a ~ca ~ l ~ u~" %U ~~ ; t x10 ~`' .A /.G: /~ ~i ~~ ~"~+~ .~~ c°~ ~,~ ~. ;APR-13-2007 06.10 RRDER ENGINEERING 970 845 ?522 P.0a~05 HOLY CROSS ENERGY RESIDENTIAL -LOAD tHFORMATIOH AND METER LOCATION FORM (contihued) SITE SKET"CHS On the spare prvvfded above please sketch the structure sfte including ~QJtt~ Arrow, roads, drfvewaysi sidewalks and Droppsed meter locadon(s}, S~,c~~ ~~ U,n ~~- G{ ~~ ~l~~v-1„ur 1~~ Physical address of project: 2~ 2 ~. Vl'~'A'D6~ v~l V~ 1f~11G, C c~ Sc I (o~_ ,zite~oa 5 APR-13-20@7 0S. 11 RARER ENGINEERING 970 S45 7522 P.05~@5 `~ ~, Appendix D EXCEPTION/REVISION FORM FOR HOLY CROSS ENERGY CONSUMER SERVICE FACILITIES METERING AND USE "GUIDEBOOK" Use this form when requesting exceptions or changes to the Hoty Cross Energy "GUIDEI300K". Please print leg(bly or type. _ S F_.RV\C,1;_S 1 seek exception to she following section(s): ~~ 1 seek revision to the following settion(s): This section is responsible for tha following problem(s): VS. 2 $~Rv~~Es legal description of property M av ~~.: ~. ~ ~ s 2q rL ~- A~ FA bo w TJTLi ~. d.> ~/ -?~ ~{ 3~ N `fib 1 reL~UeS t Lhe fOllOwing eXCeptionf change (per skaccR on rcvcr;e sldc of pAge, attached 61ueD[Inu or clca-onlc file): 5' ~Er S t'ti'~ ~k~^Ta!~+~ '~~t~ ~. .S' o ~' ~ otr• L ~~Q~~' S~?~• ~~, 3, be ~ iv~lO~~e~~'~d. Explain how this practice will maintain/improve safety and reliabll)ty: C O~'`(rJlNt~/(,- Z S E~2-V ~ GF..~ 1 NTZ) ~.- (~ ~~-L 01~C~~dJaO 'f4~nSJNG C.~. ~£-~2.~1CE, ~ 1 ~ rJo"~" ~2AG'R Gr4 C- "1'~ ~ U N /V EK1 S1~-V(CE Cd~u'D uG.T~kS ~ t° ~ ~~ 'll-I~.E w ~ ~~ Garr f3E ~ ~ NC-1~E~ a~ r~V Go+~~ Submits Address E-mail: Deliver to: Holy Cmss Energy Mail to: Holy Cross Energy Attention: Manager of Electric Operations Attn: Manager of Electric Operations 3799 Highway 82 P•O. >3ox 21 b0 Glenwood Springs, CO 87 601 Glenwood Springs, CO 81602 ~««HOLY CROSS ENERGY USE aNLY»»> The at'7.Ove described exception/change is hereby approved as noted, HOL ROSS EN RG `n n ~,: ~ Title: Y ~ ~' ~ '~ Date APProved~ ~ ~~ ~~'~ \ 1 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES TOWNOFVAQ, ' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 ELECTRICAL PERMIT Permit #: E08-0062 ~hc; l -~~~ ~"l AMF Project #: 06-0103 Job Address: 292 E MEADOW DR VAIL Location.....: MOUNTAIN HAUS #438 Parcel No...: 210108228037 OWNER NORTHLAND HOLDINGS, INC 04/22/2008 Status ... Applied .. Issued . . . Expires . .: ISSUED 04/22/2008 04/23/2008 10/20/2008 3100 OAK RD 210 WALNUT CREEK CA 94596 APPLICANT COURTNEY GREGORY 04/22/2008 Phone: 949-3302 SRI ARCHITECT PO BOX 1624 AVON CO 81620 CONTRACTOR MD MOLLER CO 04/22/2008 Phone: (970) 569-3913 PO BOX 1508 EDWARDS CO 81632 License: 355-E Desciption: ELECTRICAL REMODEL Valuation: $2,000.00 Square feet: 1256 *.~*~.,,..,,.,~.,~*.*****.,,*~,.~„*~„~.x.*,.,,,.~**.**~*,,,,«,,.,,~.,,.*„*«*.,** FEE SUMMARY .~.~~.~.~,,,~.,.,,.****« *«*«~„*~,.,~.*~******„«~~~.,,.,,<.*.*.«**«,.~.,,~.,,.,,.*.. Electrical Permit Fee---------> $57.50 Total Calculated Fees--> $61.50 Investigation Fee--------------> $0.00 Additional Fees----------> $0.00 Will Call Fee--------------------> $4.00 Use Tax Fee-------------------> $0.00 TOTAL PERMIT FEE---> $61.50 Total Calculated Fees-------> $61.50 Payments-----------------> $61.50 BALANCE DUE----------> $0.00 Item: 06000 ELECTRICAL DEPARTMENT 04/22/2008 RLF Action: AP APPROVALS Item: 05600 FIRE DEPARTMENT CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. RE ESTS FOR IN . ECTI SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE T 970.479.2149 OR AT OUR OFRQM 8~ 00 AM - P '1S`~ ~ 7 ~.= t Signature f caner or Contractor Date elec_prm_041908 L ****~k*********#**#######~k*#~k#~k*###~k*######ek*#**#*######*###*###*#*###########****#********** TOWN OF VAIL, COLORADO Statement ******************************************************************************************** Statement Number: 8080000510 Amount: $61.50 04/23/200812:16 PM Payment Method: Check Init: SAB Notation: 8080 MD MOLLER ----------------------------------------------------------------------------- Permit No: E08-0062 Type: ELECTRICAL PERMIT Parcel No: 2101-082-2803-7 Site Address: 292 E MEADOW DR VAIL Location: MOUNTAIN HAUS #438 Total Fees: $61.50 This Payment: $61.50 Total ALL Pmts: $61.50 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ EP 00100003111100 ELECTRICAL PERMIT FEES 57.50 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ~R,.OM _ ~ 04 2 i 2008 12:31 /ST. 12 ; 30 P002 APPLICATION WxLL NOT BE ACCEPTED YF YNCOMPLETE OR UNSIG ED Project #: ~R~01o'b D - Building Permit #: i~~l •(~~ i S~ Electrical Permit #: Ems'-OD62 r A ~ ~ ~j `~ 970-479-2],49 (Inspections) ~t ~1~iL 7S S. iF ranls~e itd. Vail, Colorado 81657 TOWN OF VAIL ELECTRICAL PERMIT APPLICATION CONTRACTOR INFORMATION AMOUNT OF SQ FT IN STRUCTURE: (a-S~ ELECTRICAL VALUATION: $ (~ • wriA ~~. ~./~Mi~nl~.i rnm fifi• pa~r~-/ conCaCt ra /e c.oun .y55e5sals vlnc.~ a~ ~i v-~w-~~=~ ~- - - - - -- - - - Parcel # ~ ~~.~~ )ob Name: ~~' t -~.1~~~ Job lddress: Ow'~ ~ - ~ti1~~.U ~1r•~ ~ ~-{.-~~ .r Legal Description Lat: Block: Filing: Subdivision: wn r Name t .. t~C '7 Phone: Engineer: Address: Phone: Detailed description of w_~or'Ik^u:^11r^J`~J rn~' \\ ~~~1~ ~~F~ f wv ' - Work Class: New () Addition ( ) Remodel ) Repair ( ) Temp Power ( ) Other ( ) Work Type: interior ) Exterior ( ) Both ( ) Does an EHU exist at this location: Yes ( ) No ( ) Type of Bldg.: Single-famlly ( ) Duplex ( ) Multi-family ( ) Commercial (X) Restaurant ( )Other ( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: Is this ermit for a hot tub: Yes No Does a Fire Alarm Exist; Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No ( ) *ww*w,~,vwwwwwwww,vv.wwwwwwxwwwwxxxuwvuxw~:.~FOR OFFICE USE ON~.Ywwwwwww Other Fees: ~ Date Received: DRB Fees: - :. ~ ' 'Acce ted B ~ ... Planner SI n-off:' ~ ~ ~ ' " F:\cdev~FOitMS\r'ermi~U3uilding\electiwl~2rm-~,i 1•x3-2005. DOC Page 1 of 2 [~_V ~~~~ ~twwwwaww~t aw xwwx~l is R APR 2:2008 )WN OF VAIL 11/23/2005 COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor & Materials) FROM ~ 04 21 2008 12; 31/ST.12:30 P003 1 10A~'OFYAQ, " Amendment to the 2002, N.E.C. Town of Vail Or_dunance 4, Series of 2005 ~ Overhead services are not allowed in the Town of Vail. ^ Underground services sha// be in conduit (PVC) from the uti/ity transformer to the electric meter, main disconnect switch, and to the first electrical distribution circuit breaker panel. ^ The main disconnect switch shall be neadi/yaccessible, andlocated next to the meter on the exterior wall of the structure. All underground conduits are required to be inspected before back filling the trench. ^ In multi-family dwelling units, no electrical wiring or feeder cables shall pass from one unit to another. Common walls and spaces are exempt. u NM Cable (ROmex) can be used on/y in singe and mu/ti-farm/y dwe//ings not e~rceedinq 3 stories. Type NM cannot be used in any bui/ding mixed with Type A,B.E,F H,I,M &S occupancies. ^ A/uminum conduetorssmaller than size #8 are not permitted. TOWN OF VAIL ELECTRICAL PERMIT GUYDELINES u All installations of exterior hot tubs orspa's require a DRB approval from planning. This application will not be accepted without a copy of the DRB approval form attached (if applicable). ^ If this permit is for installation of an exterior hot tub or spa on a new elevated platform or deck over 30"above grade, you must also obtain a building permit. ^ If this permit is for installation of an exterior hot tub or spa on any existing deck or elevated platform, a structural engineer must review the existing condition and verify that it will support the added concentrated load. Please provide a copy of the structural engineers wet stamped letter or drawing with this application. u If this is a remodel in amulti-family building with a homeowners association, a letter of permission from the association is required. ^ IF this permit is for a commercial space, two (2) sets of stamped drawings are required. E/ect~ica/ one-/ire and pane/ schedu/es are required if /oad is added or distriburron is a/t~ered. I hav and understa -the above. Signature ate igned If you have any questions regarding the above information or have additional questions, please contact the Town of Vail Electrical Inspector at 970-479-2147. The inspector can be reached on Monday thru Friday mornings between the hours of Sam and gam. You may also leave a voice mail and the inspector will call you back. F:\cdev\FORMS\Permi~l6uilding\electlcal~crmlLl1-23-2005.DOC Page 2 of 2 11/23/2005 TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Permit #: F08-0024 ':~"i -tea `~ Job Address: 292 E MEADOW DR VAIL Status ...: ISSUED Location.....: MOUNTAIN HAUS #438/440 Applied ..: 05/01/2008 Parcel No...: 210108228037 .Issued . .. 05/13/2008 Project No '-'i- "cZ~a ~ - O tc~ ~ Expires . .: OWNER NORTHLAND HOLDINGS, INC 3100 OAK RD 210 WALNUT CREEK CA 94596 APPLICANT CENTRAL FIRE PROTECTION 10775 E. 51ST AVENUE DENVER CO 80216 License: 447-5 CONTRACTOR CENTRAL FIRE PROTECTION 10775 E. 51ST AVENUE DENVER CO 80216 License: 447-5 05/01/2008 05/01/2008 Phone: 303-576-8157 05/01/2008 Phone: 303-576-8157 Desciption: LOWER 6 SIDEWALLS, PLUG ONE SIDEWALL, CHANGE ONE SIDEWALL TO A PENDANT. Valuation: $1,100.00 ******************************************************************** FEE SUMMARY ************************************************************ Mechanical---> $ o . 0 0 Restuarant Plan Review--> $ o . o o Total Calculated Fees---> $ 3 96.75 Plan Check---> $ 3 5 0 . 0 0 DRB Fee---------------------> $ 0 . 0 0 Additional Fees-----------> ($19 0 . 0 0 ) Investigation-> $ o . o o TOTAL FEES--------------> $ 3 96.75 Total Permit Fee----------> $ z o 6.75 Will Call-----> $ o. o o Payments-------------------> $ 2 0 6. 7 5 BALANCE DUE---------> $ 0 . 0 0 ************************************************************************** *********************************************************************** Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 05/12/2008 mmcgee Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ************************************************************************************************************************************************* DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOURS IN ADVANCE BY TELEPHONE AT 970-479-2252 FROM 8:00 AM - 5 PM. ~ ~ ~ SIGNATURE QI";bWNER ORiCfl3NTRACTOR FOR HIMSELF AND OWNER TOWN OF VAIL, COLORADO Statement Statement Number: 8080000685 Amount: $206.75 05/13/200809:07 AM Payment Method: Check Init: DDG Notation: Central Fire Protection 1014 ----------------------------------------------------------------------------- Permit No: F08-0024 Type: SPRINKLER PERMIT Parcel No: 2101-082-2803-7 Site Address: 292 E MEADOW DR VAIL Location: MOUNTAIN HAUS #438/440 Total Fees: $206.75 This Payment: $206.75 Total ALL Pmts: $206.75 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 206.75 ~~ENTRAL Fire Protection Contractors Inc. Vail Fire Department 42 W Meadow Drive Vail, CO 81657 Ph. 970-479-2252 Fx. 970-479-2176 RE: Mt. Haus 292 E Meadow Dr Unit 440 Vail, CO Attention Mike Vaughan; Date: April 28, 2008 Central Fire Protection is working at the Mountain Haus, unit 440. Unit has a total of 8 sidewall sprinklers. In this unit the ceiling is being lowered approximately 2 '/4". The sidewall sprinklers will be lowered to maintain the 4" minimum clearance from the new ceiling. "There are six sidewalls that will be lowered. There are two sidewalls in the kitchen above the cabinets. These sprinklers can not be lowered due to the cabinets. One of these sidewalls will be plugged and the other sidewall will be piped in the furred down section to a location that will provided complete coverage of the kitchen area and a pendent sprinkler will be installed. If you have, any questions please call. 303-576-8157 ext. 23. Cc: File Thank You, Jeff Martin Designer Central Fire Protection Contractors, Inc. 10775E 51St Avenue Denver, CO 80239 Ph. 303-576-8157 Ext 23 Fx. 303-576-8159 Email: ieffbmartin~a~c.us Jeffrey B. Martin NICET III- #98816 Sprinkler System Layout APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED Protect #: _ ~(zJD6 -0103 Building Permit #: B 0 7 - 0 017 Sprinkler Permit #: f Og- nDa-r4 ~~~~~ ~ TOWN OF VAIL FIRE SPRiNKLFR pFRINrr ela~~ r~errnN Fire Sprinkler shop drawings are required at time of permit submittal and 75 S. Frontage Rd. must include the following. Permit application will not be accepted Vail, Colorado 81657 without this information: ^ A Colorado Registered Engineer's stamp or N.I.C.E.T. Level III (min) stamp. ^ Equipment cut sheets of materials. ^ Hydraulic calculations. ^ A State of Colorado Plan Registration form. ^ Plans must be submitted by a Registered Fire Protection Contractor. TION Fire Sprinkler Contractor: Town of Vail Reg. No.: Contact and Phone #'s: Central Fire Protection 447-5 Jeff Martin 303-576-8157 E-Mail Address: J et tbmartinQcfpc . us s ~ ~ ~~ ®~ -~ Contractor Signature: // A~r~fovec! ~s Subn»tted FOR Fire Sprinkler: $ 1, 10 ~ ~ Contact Eao% County ACCp!ccnrs Office at 97n-.3?R_R~'~ nr visit u,u,~~, can~a~.,,,nh. „~ a./. o~.,/si ,.Ss - - - - _ _ _ . _ Parcel # ~ .V/ / fI/ YG/ 1T Job Name: Unit 440 Job Address: 292 E Meadow Drive Vail Legal Description Lot: Block: Filing: Subdivision: Owners Name: ort an Address: a to Phone: Engineer: Address: Phone: Detailed Location of work: (i.e., floor, unit #, bldg. #) Unit 440 Detailed description of work: Lower 6 sidewalls, to a endent. plug one sidewall, change one sidewal Work Class: New () Addition ( ) Remodel (X) Repair ( ) Retro-fit ( ) Other ( ) Type of Bldg.: Single-family ( ) Two-family ( ) Multi-family ( ) Commercial ( ) Restaurant ( )Other ( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: Does a Fire Alarm Exist: Yes (X) No ( ) Does a Fire Sprinkler System Exist: Yes (X) No ( ) ************~**************************FOR OFFICE USE ONLY*********** ,~a~~a~.~**,~_--.. ,; :, ~, b Other Fees: Date Received: Public Wa Permit Fee: Acce B Occupancy Group: `~, i ~~f ,'~-~' ~ f~ ~; F:\cdev\FORMS\PERMITS\Fire\sprinlder_perm_12-5-05.ooc ~ ~~~' ~~°~1$LS~~2~, ~ ~.. N NOTE: THIS PERMI T MUS T BE POSTED ON JOBS/ TE A T ~nwxoFUnd. Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT AMF Job Address: 292 E MEADOW DR VAIL Location.....: MOUNTAIN HAUS #438 Parcel No...: 210108228037 OWNER NORTHLAND HOLDINGS, INC 3100 OAK RD 210 WALNUT CREEK CA 94596 APPLICANT SKYLINE MECHANICAL P.O. BOX 1258 GYPSUM CO 81637 License: 121-M CONTRACTOR SKYLINE MECHANICAL P.O. BOX 1258 GYPSUM CO 81637 License: 121-M 05/09/2008 05/09/2008 Phone:970-524-6809 05/09/2008 Phone:970-524-6809 Desciption: MOUNTAIN HAUS #438-REPAIR AND REPLACE DUCT FOR BATH FAN, INSTALL NEW DUCT TO RELOCATE NEW BATHROOM EXHAUST, ALL FIRE DAMPERS NEEDED FOR COMMERCIAL CODES Valuation: $1,900.00 ALL TIMES Permit #: M08-0096 Project #: PRJ06-0103 Status ...: ISSUED Applied ..: 05/09/2008 Issued . .. 05/12/2008 Expires . .: 11/08/2008 ..........«~.............,....~.~..........~..«......""•"••**•*•***"""********••FEE SUMMARY..........,.,. .............»..........,.............«....~~..«.........~~...........~..» Mechanical Permit Fee---> $40.00 Will Call------------> $4.00 Total Calculated Fees---> Plan Check-------------------> $10.00 Use Tax Fee------> $54.00 $0.00 Additional Fees-----------> $0.00 Investigation-----------------> $0.00 TOTAL PERMIT FEE---> $54.00 Total Calculated Fees--> $54.00 Payments-----------------> $54.00 BALANCE DUE---------> $0.00 Item: 05100 BUILDING DEPARTMENT 05/09/2008 RLF Action: AP APPROVALS Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC.. Cond: 31 (BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 mechcan ical_perm it_041908 (BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR.IP1Sf~ECTiON SHAD BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM - 4 PM. .r / / Signature of Owner or Print Name Date mechcan ical_perm it_041908 TOWN OF VAIL, COLORADO Statement ******************************************************************************************** Statement Number: 8080000655 Amount: $54.00 05/12/200809:47 AM Payment Method: Check Init: DDG Notation: Skyline Mechancial 12544 ------------------------------------------------------------------- Permit No: M08-0096 Type: MECHANICAL PERMIT ---------- Parcel No: 2101-082-2803-7 Site Address: 292 E MEADOW DR VAIL Location: MOUNTAIN HAUS #438 Total Fees: $54.00 This Payment: $54.00 Total ALL Pmts: $54.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ----- ------------------------- ----- MP 00100003111100 MECHANICAL PERMIT FEES ------- 40.00 PF 00100003112300 PLAN CHECK FEES 10.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ,May 08 2008 12:06PM Skyline Mechanical INC. 970-524-6810 p.2 APPLICATYON 'WILL lti ACCEPTED 3F INCaMPLETE OR UNSYGNE00 ~ _© Project #: ~ 10 3 ~- Building Permit #: o ~ o a Mechanical Perrttit #: ~. 970-479-2149 (inspections) ~~~QF~~ 97~•'~17~ -x138' C'p}~~ 75 5. Frontage Rd. Permit will not be accepted without the foilowin Vait, Colorado 81657 ~~ ~ a ~ [~ Provide Mechanical Room Layout drawn to scale n Mechanical Room Dimensions a Combustion Air Duct Size and Location MAY 0 9 2008 c Flue, Vent and Gas Line Size and Location r~ Heat Loss Calcs. o Equipment Cut/Spec Sheets -rnwlV ®F VAIL Ce~ntact Fao% Couety Ads OASce at 9?~-328-8640 or visit www. eaa/e-rounty cnm fnr Pa~1 aiE Parcel # (Required if no bldg, permit # is provided above) Job Name: / ~ T ~ ~ o4ti ~~ ~A~ Job Address: o~~~ ~~ ~ tG~i~l~! 02 T Legal Description Lot: Block: Filing: Subdivision: t/ f} ~ ~.- Owners Name: Address: Phone: Engineer: Address: Phone: Detailed description of work: (~~ ppqf rt K (~~ Lflee rJuc ~'o k ,.BR ~v~ I ~v.rfivr..c_ 0 u~c ~`' ~a R e~ L-o C ~fe ~v L~, B Aty~ a ~ EX h~R crrt R ~ t F f R-.,c O R -rv~~O.c/lr .-v e e o e~ Work Class: ~ New O Addition ( ) Alteration ( ) Repair ( ) Other ,~ Boiler Location: Interior ( ) E~cterior ( ) Other ( ) Does an EHU exist at this location: Yes ( ) No ( ) Type of Bldg: Single-Famiy ( ) Duplex ( ) Mutti-family ( ) Commercial ( ) Restaurant ( )Other ( ) . No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No a of Fire laces Existin Gas A liances Gas L s Wood Pellet Wood 8urnin No/Type of Fireplaces Proposed: Gas Appliances ( ) Gas Logs ( ) Wood/Pellet ( ) Wood Burning (NOT ALLOWED) Is this a c.~nversion from a wood burning fireplace to an EPA Phase II device? Yes ( ) No ( ) COIF°LETE VALUATION FOR MECHANICAL PERMIT (Labor & Materials) MECHANICAL: ~ 19oa ~ O a CONTRACTOR INFaRMATION Mechanical Contractor: Town of Vail Reg. No.: Contact and Phone #'s: ~. Contractor Signature: _-,~ ************* **********F~R OFFICE USE ONtY** sec Fees: , Plaaner~Sigri'-off: 'D~-Tees:: ~ ' . :De''ite~ Rd~CIV+E~II. . ****************~x***** D ,~ F:/evtryone/forms/medtperm NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ~owxo~v Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 PLUMBING PERMIT Permit #: P08-0040 AMF Project #: PRJ06-0103 Job Address: 292 E MEADOW DR VAIL Status ...: APPROVED Location.....: MOUNTAIN HAUS #438/440 Applied ..: 05/09/2008 Parcel No...: 210108228037 Issued . . Expires . .: OWNER NORTHLAND HOLDINGS, INC 05/09/2008 3100 OAK RD 210 WALNUT CREEK CA 94596 APPLICANT MR. PLUMBER,INC. 05/09/2008 Phone: (970) 574-6768 PO BOX 1563 EAGLE COLORADO 81631 License: 345-P CONTRACTOR MR. PLUMBER,INC. 05/09/2008 Phone: (970) 574-6768 PO BOX 1563 EAGLE COLORADO 81631 License: 345-P Desciption: CHANGE TUB DRAIN TO A SHOWER DRAIN, ROUGH IN 2 NEW SHOWER VALVE Valuation: $2,000.00 '"""**'** **************** FEE SUMMARY ,***** Plumbing Permit Fee---> $30.00 Will Call-----------------> $4.00 Total Calculated Fees---> $41.50 Plan Check----------------> $7.50 Use Tax Fee------------> $0.00 Additional Fees-----------> $0.00 Investigation--------------> $0.00 TOTAL PERMIT FEES--> $41.50 Total Calculated Fees--> $41.50 Payments-----------------> $41.50 BALANCE DUE-----------> $0.00 Item: 05100 BUILDING DEPARTMENT 05/09/2008 RLF Action: AP APPROVALS Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:01 AM - 4 PM. ~~~ Signature of Owner or tractor C-:r c<< `i I~~ L 4 't` ti Print Name ~.. ~) ~: Date plmbpermt1_041908 ~nwrroFVnn APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED Project #: P12J d ~o a ~ 03 Building Permit #: ~ -• - LG \ - Plumbing Permit #: ~R'-pO~D 970-479-2149 (Inspections) ~~{~.sa 75 S. Frontage Rd. Vail, Colorado 81657 CONTRACTOR INFORMATION Plumbing Contractor: Town of Vail Reg. No.: Contact Person and Phone #'s: E-Mail Address: Fax #: ~ '<L; ~= _ Contractoy ~ig_nature: COMPLETE VALUATION FOR PLUMBING PERMIT (Labor & Materials) PLUMBING: $ ~L ( (~ (Y) Contact Ea /e Coun Assessors Office at 970-328-8640 or visit www, ea /e-coup . com for Parce/ # Parcel # 2 ~, p a g-d '~ ]ob Name: c:. )ob Address: w ~ Legal Description Lot: Block: Filing: Subdivision: Owners Name: Address: Phone: Engineer: Address: Phone: Detailed description of wo\rk: Work Class: New () Addition ( ) Alteration ( ) Repair ( ) Other ( ) Type of Bldg.: Single-family ( ) Duplex ( ) Multi-family ( ) Commercial ( ) Restaurant ( )Other ( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: ************~****~**~*~***~*****~******FOR OFFICE USE ONLY*~~****~**~*~~****~*********~******** D ~C~f~~M~ D MAY 0 9 2008 TOWN OF VAIL TOWN OF VAIL PLUMBING PERMIT APPLICATION \\ y ~w- F:\cdev\FORMS\PERMITS\Building\plumbing_permit_11-23-2005.doc Page 1 of 1 11/23/2005 `a ` ********************#~k#***#**#***###*~k****####**##*#*######***+k***********#***************** TOWN OF VAIL, COLORADO Statement Statement Number: 8080000650 Amount: $41.50 05/09/200812:20 PM Payment Method: Check Init: RLF Notation: 2265 MARCELO REYES ----------------------------------------------------------------------------- Permit No: P08-0040 Type: PLUMBING PERMIT Parcel No: 2101-082-2803-7 Site Address: 292 E MEADOW DR VAIL Location: MOUNTAIN HAUS #438/440 Total Fees: $41.50 This Payment: $41.50 Total ALL Pmts: $41.50 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 7.50 PP 00100003111100 PLUMBING PERMIT FEES 30.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ~, 06-06=2008 Inspection Request Reporting Page 19 4.22 pm Vail CO -City Of Requested Inspect Date: Monday, June 09, 2008 Inspection Area: JP Site Address: 292 E MEADOW DR VAIL MOUNTAIN HAUS #438 AND 440 A/P/D Information Activity: B07-0017 Type: A-MF Sub Type: AMF Status: ISSUED Const Type: Occupancyy: Use: 1 B Insp Area: JP Contractor: BOLES CUSTOM BUILDERS, INC Phone: 970-926-3202 Owner: NORTHLAND HOLDINGS, INC Description: MOUNTAIN HAUS #438-REMODEL INTERIOR, NEW WALL, DRYWALL, KITCHEN, BATHS Item::'90% BLDG-Final '~ Requested Time: 08:00 AM Requestor;` BOLES CUSTOM B~ILDERS, INC /BRAD Phone: 970-376-7753, BRAD Comments: WILL CALL BRAD; CALL RECEIVED 6/5 AT 4:24 Assigned Tc,S: JMONDRAGON ,~ Entered By: LCAMPBELL K Action: ~ Time Exp: .\ . :. n i` ~~ ~ ~ ~ r ,. f~' ~, ... ~ ~, ;iq ~~ . ~' I Inspection History Item: 30 BLDG-Framing 04/30/08 Inspector: Comment: FRAMING 05/14/08 Inspector: Comment: Item: 60 BLDG-Sheetrock Nail JRMpproved `* ~RPNROVED FOR "" Approved "" ~` ._: Action: PA PARTIAL APPROVAL 4LL EXCEPT FOR BATHROOMS Action: AP APPROVED 04/30/08 Inspector: JRM Action: PA PARTIAL APPROVAL Comment: PATCHES APPROVED... BATHROOMS NOT DONE 05/14/08 Inspector: JRM Action: PA PARTIAL APPROVAL Comment: ALL EXCEPT FOR BATH ROOMS 05/20/08 Inspector: jgulick Action: PA PARTIAL APPROVAL Comment: Drywall screws all ok. Item: 70 BLDG-Misc. "* Approved "' 05/07/08 Inspector: JRM Action: AP APPROVED Comment: APPROVED 2 HR CHASES Item: 90 BLDG-Final REPT131 Run Id: 8018 ~ ~ l 06-06-2008 Inspection Request Reporting Page 33 4:22 pm Vail,~p - itv pf Requested Inspect Date: Monday, June 09, 2008 Inspection Area: SH Site Address: 292 E MEADOW DR VAIL MOUNTAIN HAUS #438/440 A/P/D Information Activity: POS-0040 Type: B-PLMB Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: Insp Area: SH Owner: NORTHLAND HOLDINGS, INC Contractor: MR. PLUMBER,INC. Phone: (970) 574-6768 Description: CHANGE TUB,D7'TZTQ SHOWER DRAIN, ROUGH IN 2 NEW SHOWER VALVE Item: Requestor: Comments: Assigned To: Action: Comment: Inspection History Item: 220 PLMB-Rou h/D.W.V. 05/14/08 Ins ector p : Comment: Item: 230 PLMB-Rough/Water 05/14/08 I t nspec or: Comment: Item: 240 PLMB-Gas Piping Item: 260 PLMB-Misc. Item: 290 PLMB-Final 06/05/08 Inspector: Comment: Requested Time: 11:30 AM Phone: 970-376-7753, BRAD Entered By: LCAMPBELL K Time Exp: ' ; -rl ~^ ~ , ~ i ~>'ll - "'` Approved "" JRM JRM** Approved " JRM ~~ l ~ ~, 1 J. f.~ ~r ~ ~ ; ~. i t Action: AP APPROVED Action: AP APPROVED Action: NR NOT READY FOR INSPECTION REPT131 Run Id: 8018 E08 -0062: Entries for Item: 190 - ELEC -Final 11:35 02/06/2013 Action Comments By Date Unique_ Key NR not ready mgsafe 06/05/2008 A000114 284 AP shahn 06/06/2008 A000114 369 Total Rows: 2 Page 1