Loading...
HomeMy WebLinkAboutBegin_Workflow - Review Comments - 07-02-2014 WITH RESPONSES.pdfBegin_Workflow ­ Review Comments ­ 07­02­2014_10­53­18 Review Cycle Department Markup Snapshot 1 Building File: 140421­S1­SPEC.pdf ChangeMark: mhaeberle Description: B001 Comment: Provide a copy of the report to verify plans conform to the report. 1 Building File: 140421­S6­DETL.pdf ChangeMark: mhaeberle Description: B001 Comment: Please address the possible surcharge from the sewer line and wetlands adajcent to the building foundation 1 Building File: 140421­S6­DETL.pdf ChangeMark: mhaeberle Description: B002 Comment: The proposed footing appears to encroach into the easemnt for the public sewer. 1 Building File: har­res 01 ­ Sheet ­ A000 ­ Cover.pdf ChangeMark: mhaeberle Description: B001 Comment: R3 1 Building File: har­res 01 ­ Sheet ­ A000 ­ Cover.pdf ChangeMark: mhaeberle Description: B002 Comment: Indicate a blower door test is required prior to building final inspection per IECC 1 Building File: har­res 01 ­ Sheet ­ A000 ­ Cover.pdf ChangeMark: mhaeberle Description: B003 Comment: Annotate on plans required sprinkler and alarm system per Fire Marshall 1 Building File: har­res 01 ­ Sheet ­ A002 ­ GRFA CALCS.pdf ChangeMark: mhaeberle Description: B001 Comment: Provide actual square footages for each side to include the entire building envelope for the purposes of determining recreation fees and building code analysis 1 Building File: har­res 01 ­ Sheet ­ A111 ­ REFLECTED CEILING PLAN.pdf ChangeMark: mhaeberle Description: B001 Comment: Provide panel locations 1 Building File: har­res 01 ­ Sheet ­ A111 ­ REFLECTED CEILING PLAN.pdf ChangeMark: mhaeberle Description: B002 Comment: Show CO detector locations. Typical 1 Building File: har­res 01 ­ Sheet ­ A111 ­ REFLECTED CEILING PLAN.pdf ChangeMark: mhaeberle Description: B003 Comment: Indicate lighting to be 75% high efficacy 1 Building File: har­res 01 ­ Sheet ­ A302 ­ BUILDING SECTIONS.pdf ChangeMark: mhaeberle Description: B001 Comment: Safety Glazing 1 Building File: har­res 01 ­ Sheet ­ A401 ­ WALL SECTIONS.pdf ChangeMark: mhaeberle Description: B001 Comment: How is the thermal envelope being obtained? 1 Building File: har­res 01 ­ Sheet ­ A401 ­ WALL SECTIONS.pdf ChangeMark: mhaeberle Description: B002 Comment: Show on plans 1 Building File: har­res 01 ­ Sheet ­ A401 ­ WALL SECTIONS.pdf ChangeMark: mhaeberle Description: B003 Comment: Clarify R value and materials 1 Building File: har­res 01 ­ Sheet ­ A401 ­ WALL SECTIONS.pdf ChangeMark: mhaeberle Description: B004 Comment: Show R values in variuos conditions as identifed in Res check 1 Building File: har­res 01 ­ Sheet ­ A402 ­ WALL SECTIONS AND DETAILS.pdf ChangeMark: mhaeberle Description: B001 Comment: Roof insulation is not continued. Please clarify. Not in conformance wth Rescheck 1 Building File: har­res 01 ­ Sheet ­ A402 ­ WALL SECTIONS AND DETAILS.pdf ChangeMark: mhaeberle Description: B002 Comment: Loss of building envelope. Please show compliance with the energy code 1 Building File: har­res 01 ­ Sheet ­ A402 ­ WALL SECTIONS AND DETAILS.pdf ok, uploaded ERWSD ENCROACHMENT AGREEMENT APPROVED, RECORDED AGREEMENT ATTACHED OK, MODIFIED NOTE ADDED NOTE ADDED GROSS BUILDING SF ADDED OK, SHOWN ON A 112 ELEC LEGEND MODIFIED NOTE ADDED NOTE ADDED DETAIL MODIFED SHOWN ON L-3 DETAIL MODIFIED R-VALUES CLARIFIED DETAIL MODIFIED DETAIL MODIFIED checked with ERWSD and civil engineer, and neither one says there should be any. note from civil attached 08/18/14 ChangeMark: mhaeberle Description: B003 Comment: Insulation? Please clarify 1 Building File: har­res 01 ­ Sheet ­ A501 ­ DETAILS.pdf ChangeMark: mhaeberle Description: B001 Comment: Provide design to show compliance for loads per Chapter 16 of the IBC to include a four times strength requirement per the glazing provisions of the IBC 1 Building File: har­res 01 ­ Sheet ­ A503 ­ DETAILS.pdf ChangeMark: mhaeberle Description: B001 Comment: Identify Class A roof system to beused. Detail on plans 1 Building File: har­res 01 ­ Sheet ­ A503 ­ DETAILS.pdf ChangeMark: mhaeberle Description: B002 Comment: how is weather/ vapor barrier to be achieved? Does stucco systme allow the proposed termination without weep screed/ PLease clarify 1 Building File: har­res 01 ­ Sheet ­ A503 ­ DETAILS.pdf ChangeMark: mhaeberle Description: B003 Comment: Where is this draining? 1 Building File: har­res 01 ­ Sheet ­ A602 ­ WINDOW SCHED­ & TYPES.pdf ChangeMark: mhaeberle Description: B001 Comment: Provide u values as it is related to the windows and doors. Should coincide with Rescheck. Revise all sheets 1 Building File: har­res 01 ­ Sheet ­ M1 ­ piping and venting plan.pdf ChangeMark: mhaeberle Description: B001 Comment: provide gas pressure used and materials 1 Building File: har­res 01 ­ Sheet ­ M1 ­ piping and venting plan.pdf ChangeMark: mhaeberle Description: B002 Comment: Automatic shutoff required per town ordinance. Please show 1 Building File: Harman Landscape­L­1 Landsc main.pdf ChangeMark: mhaeberle Description: B001 Comment: Required to stamp plans per state (DORA) Revise all sheets 1 Building File: Harman Landscape­L­1 Landsc main.pdf ChangeMark: mhaeberle Description: B001 Comment: Provide a 2% grade away from building with positive drainage 1 Building File: Harman Landscape­L­3 site plan main.pdf ChangeMark: mhaeberle Description: B001 Comment: Cannot run public sewer through house. Please clarify compliance with IPC 2012 1 Building File: B14­0220 Rescheck.pdf ChangeMark: mhaeberle Description: B001 Comment: Please sign. 1 Building File: B14­0220 Rescheck.pdf ChangeMark: mhaeberle Description: B002 Comment: Clarify glazing calculation for glass doors 1 Public Works File: Harman Landscape­L­1 Landsc main.pdf ChangeMark: tkassmel Description: PW001 Comment: Provide top and bottome of wall elevations. Walls over 4' require and engineered stamped detail. 1 Public Works File: Harman Landscape­L­1 Landsc main.pdf ChangeMark: tkassmel Description: PW002 Comment: Provide erosion control plan. Is this Limit of Disturbance fence, silt fence? 1 Public Works File: Harman Landscape­L­1 Landsc main.pdf ChangeMark: tkassmel Description: PW003 Comment: Improvements and grade changes above and surrounding existing sanitary sewer require ERWSD review and approval. Please provide that approval document. 1 Public Works File: Harman Landscape­L­1 Landsc main.pdf ChangeMark: tkassmel Description: PW004 Comment: No grading or work is permitted within the 100 year floodplain. Show limit of disturbance fence outside of 100 year floodplain line. If areas are planned to be disturbed are within a couple of feet of the 100 year floodplain the floodplain shall be staked in the field prior to work begins in order to ensure no changes occur within the floodplain. 1 Public Works File: Harman Landscape­L­1 Landsc main.pdf ChangeMark: tkassmel Description: PW005 DETAIL MODIFIED NOTE ADDED NOTE ADDED DETAIL MODIFIED NOTE ADDED U-VALUES ADDED NOTES ADDED NOTE ADDED STAMP ADDED NOTES ADDED WASTE LINE CLARIFIED OK U-VALUES NOTED NOTES ADDED NOTE ADDED, LIMITS FENCE IS SILT FENCE ERWSD APPROVAL FINAL, BEING RECORDED LINEWORK REMOVED FROM FLOODPLAIN 08/18/14 Comment: Provide TW and BW elevation for tallest part of wall. This area looks to be just over 4'. 1 Public Works File: Harman Landscape­L­1 Landsc main.pdf ChangeMark: tkassmel Description: PW006 Comment: No grading in the floodplain, move limits of disturbance to be outside of floodplain. 1 Public Works File: Harman Landscape­L­1 Landsc main.pdf ChangeMark: tkassmel Description: PW007 Comment: It is not clear as to whether or not boulders along the creek are existing or proposed locations. Please differentiate between proposed and existing. No boulders shall be placed along the creek or within the Floodplain. 1 Public Works File: Harman Landscape­L­1 Landsc main.pdf ChangeMark: tkassmel Description: PW008 Comment: Please show where each utility will be served from. 1 Public Works File: Harman Landscape­L­2 Landsc north.pdf ChangeMark: tkassmel Description: PW001 Comment: Where does this concrete pan drain to? 1 Public Works File: Harman Landscape­L­2 Landsc north.pdf ChangeMark: tkassmel Description: PW002 Comment: Show where proposed utilities will be served from. 1 Public Works File: Harman Landscape­L­2 Landsc north.pdf ChangeMark: tkassmel Description: PW003 Comment: Are the proposed landscape improvements, and address marker sign allowed per the access and utility easement? Some of the proposed trees fall right on the easement line. Have these been approved by the Parcel A,C owners? 1 Public Works File: Harman Landscape­L­2 Landsc north.pdf ChangeMark: tkassmel Description: PW004 Comment: Provide PE stamped retaining wall detail. 1 Public Works File: Harman Landscape­L­3 site plan main.pdf ChangeMark: tkassmel Description: PW001 Comment: How will the wetlands be protected? 1 Public Works File: Harman Landscape­L­4 site plan north.pdf ChangeMark: tkassmel Description: PW001 Comment: Public Way permit will be required for any work within the Town Public Way, (i.e. utility connections). ALL WALLS <4'H, NOTED MOVED CLARIFIED TRIED TO SHOW THIS MORE CLEARLY NOTE ADDED NOTED NEIGHBOR EASEMENT AGREEMENT FINALIZED, BEING RECORDED, SIGNATURE SHEETS ATTACHED WALL <4'H NOTE ADDED SILT FENCE AROUND THE WETLAND PERIMETER NOTE ADDED 08/18/14