Loading...
HomeMy WebLinkAbouthar-res 01 - Sheet - A000 - Cover.pdfFOR CONSTRUCTION Scale Project number Date Drawn by Checked by 10/27/2014 8:11:01 PM A000 Cover har-13 RESIDENCE HARMAN 10.27.2014 WMC - GENERAL NOTES: 1. DO NOT SCALE DRAWINGS. 2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. 3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR AREAS. 4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS OTHERWISE NOTED. 5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS. 6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR TYPES. 7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. 8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS. 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY IN THE PROJECT. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE UNIFORM BUILDING CODE 1997 EDITION. COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN UBC AND ALL LOCAL AND REGIONAL CODES. 11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION. 12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. 13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF & DECK SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL PROBLEMS WITH THESE SURFACES. 14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN APPROVAL. 15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. 16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS TO THE SITE. 18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE. 19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER. 20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT. HARMAN RESIDENCE CODE: INTERNATIONAL RESIDENTIAL CODE 2012 ZONING: TWO FAMILY RESIDENTIAL DISTRICT OCCUPANCY CLASSIFICATION: R-3 BUILDING FULLY SPRINKLED WITH AUTOMATIC ALARM SYSTEM PER IECC, BLOWER DOOR TEST IS REQUIRED PRIOR TO FINAL INSPECTION PROJECT SUMMARY: ARCHITECT: K.H. WEBB ARCHITECTS P.C. 710 WEST LIONSHEAD CIR., SUITE A VAIL, CO 81657 PH. 970-477-2990 Michael@khwebb.com CONTACTS: KYLE H. WEBB / MICHAEL CURRENT PROJECT TEAM: CONTRACTOR: VAIL CUSTOM BUILDERS 0429 EDWARDS ACCESS RD., STE. A207 PO BOX 2809 EDWARDS, CO 81632 PH. 970-926-8771 LANDSCAPE ARCHITECT: DENNIS ANDERSON ASSOC. PO BOX 1387 EDWARDS, CO 81632 PH. 970-390-3745 SURVEYOR: EAGLE VALLEY SURVEYORS P.O. BOX 1230 EDWARDS, COLORADO 81632 PH. 970.949.1406 DRAWING INDEX: CIVIL TS 1 TOPOGRAPHIC SURVEY LANDSCAPE L-1 SOUTH LANDSCAPE PLAN L-2 NORTH LANDSCAPE PLAN L-3 SOUTH SITE/GRADING PLAN L-4 NORTH SITE/GRADING PLAN L-5 CONSTRUCTION MANAGEMENT PLAN ARCHITECTURAL A 001 SITE PLAN A 002 SQUARE FOOTAGE CALCS A 003 EXTERIOR LIGHTING PLAN A 100 CRAWL SPACE PLAN A 101 LEVEL ONE FLOOR PLAN A 102 LEVEL TWO FLOOR PLAN A 103 ROOF PLAN A 111 LOWER LEVEL REFLECTED CEILING PLAN A 112 MAIN LEVEL REFLECTED CEILING PLAN A 113 UPPER LEVEL REFLECTED CEILING PLAN A 201 EXTERIOR ELEVATIONS A 202 EXTERIOR ELEVATIONS A 301 BUILDING SECTIONS A 302 BUILDING SECTIONS A 401 WALL SECTIONS A 402 WALL SECTIONS AND DETAILS A 501 DETAILS A 502 DETAILS A 503 DETAILS A 601 WINDOW TYPES A 602 WINDOW TYPES A 603 INT. DOOR SCHEDULE AND DETAILS A 604 ENLARGED PLANS AND INTERIOR ELEVATIONS A 901 PERSPECTIVES A 902 PERSPECTIVES STRUCTURAL S1 SPECIFICATIONS S2 FOUNDATION PLAN S3 MAIN FLOOR FRAMING PLAN S4 UPPER FLOOR FRAMING PLAN S5 ROOF FRAMING PLAN S6 DETAILS MECHANICAL AND PLUMBING M1 GAS PIPING DIAGRAM AND VENTING PLAN PERMIT REVISIONS 10.27.2014 4290 Columbine Drive, Vail, Colorado VICINITY MAP: No. Description Date 11/11/14