Loading...
HomeMy WebLinkAboutB14-0223 REV1 window schedule.pdf3 Visible Transmittance (VT) measures how much light comes through a product (glass and frame). The higher the value, from 0 to 1, the more daylight the product lets in over the product’s total unit area. NFRC ratings are based on modeling by a third party agency as validated by an independent test lab in compliance with NFRC program and procedural requirements. This data is accurate as of October 7, 2013. Due to ongoing product changes, updated test results, or new industry standards or requirements, this data may change over time. Due to variations in dealer and distributor inventory levels, products that were manufactured before October 7, 2013 that were designed, tested and labeled with different NFRC values may still be available. Check the labels on the product packaging to confirm NFRC values. Ratings are for sizes specified by NFRC for testing and certification. Ratings may vary depending on use of tempered glass, different grille options, glass for high altitude, etc. Values shown are based on a 30610 I/S french door with SP1 panel and HP sill configured at PG40. 1 U-Factor defines the amount of heat loss through the total unit in BTU/hr*ft2*°F; metric in W/m2*K. The lower the value, the less heat is lost through the entire produc Eagle Window & Door Manufacturing Inc. is a wholly owned subsidiary of Andersen Corporation. The NFRC logo is a registered trademark of the National Fenestration Rating Council. All rights reserved. "ENERGY STAR" is a registered trademark of the U.S. Environmental Protection Agency. "Andersen", "Eagle" and all other marks where denoted are trademarks of Andersen Corporation and its subsidiary. © 2013 Andersen Corporation. All rights reserved. 2 Solar Heat Gain Coefficient (SHGC) defines the fraction of solar radiation admitted through the glass both directly transmitted and absorbed and subsequently released inward. The lower the value, the less heat is transmitted through the product. Andersen® E-Series/Eagle® Product NFRC/ENERGY STAR® Information This document provides NFRC certified U-Factor, Solar Heat Gain Coefficient (SHGC) and Visible Transmittance (VT) values for E-Series/Eagle products along with the corresponding ENERGY STAR (2010) climates zones that the product and glass type meet. These products are rated, certified, and labeled by National Fenestration Rating Council® (NFRC) - a non-profit organization that provides fair, accurate and credible energy performance ratings for windows and doors. These products meet stringent energy efficiency guidelines set by the U.S. Environmental Protection Agency and the U.S. Department of Energy. These guidelines are based on the heat gain and loss of each product in various regions of the country. Product qualifications listed in this document refer to US ENERGY STAR Version 5.0 (referred to as 2010) that went into effect on January 4, 2010 and Canada ENERGY STAR Program requirements that went into effect October 1, 2010 (referred to as 2010). Page 1 of 2 NorthNCSCSouthZone AZone BZone CZone DE-Series/Eagle®EWD-N-68-00897-00001 HP Low-E4® (272) 3.1mm / 13mm / 3.1mm None 1.76 0.31 0.24 0.41 12.N .N .S .S ..A .- .- .- . EWD-N-68-00912-00001 HP Low-E4® (272) 3.1mm / 13mm / 3.1mm 5/8" or 7/8" MDL 1.82 0.32 0.21 0.35 9.N .N .S .S ..A .- .- .- . EWD-N-68-00897-00002 HP Low-E4® (272) 3.1mm / 13mm / 3.1mm 5/8" or 7/8" CDL (no spacer) 1.76 0.31 0.21 0.35 11.N .N .S .S ..A .- .- .- . EWD-N-68-00922-00001 HP Low-E4® (272) 3.1mm / 13mm / 3.1mm 1-1/8" MDL 1.82 0.32 0.18 0.30 8.N .N .S .S ..A .- .- .- . EWD-N-68-00917-00001 HP Low-E4® (272) 3.1mm / 13mm / 3.1mm 1-1/2" MDL 1.82 0.32 0.18 0.30 8.N .N .S .S ..A .- .- .- . EWD-N-68-00897-00003 HP Low-E4® (272) 3.1mm / 13mm / 3.1mm 1-1/8" or 1-1/2" CDL (no spacer) 1.76 0.31 0.18 0.30 9.N .N .S .S ..A .- .- .- . EWD-N-68-00902-00001 HP Low-E4® (272) 3.1mm / 13mm / 3.1mm 5/8" Between-Glass Grilles 1.76 0.31 0.21 0.35 11 .N .N .S .S ..A .- .- .- . EWD-N-68-00907-00001 HP Low-E4® (272) 3.1mm / 13mm / 3.1mm 1" Between-Glass Grilles 1.82 0.32 0.21 0.35 9 .N .N .S .S ..A .- .- .- . EWD-N-68-01154-00001 HP Low-E4® (272) 3.1mm / 13mm / 3.1mm 2-1/4" MDL 1.87 0.33 0.18 0.30 6.- .- .- .-..-.-.-.-. EWD-N-68-00899-00001 HP Low-E4® Sun (240) 3.1mm / 13mm / 3.1mm None 1.76 0.31 0.15 0.23 7.N .N .S .S ..A .- .- .- . EWD-N-68-00914-00001 HP Low-E4® Sun (240) 3.1mm / 13mm / 3.1mm 5/8" or 7/8" MDL 1.82 0.32 0.13 0.20 5.N .N .S .S ..A .- .- .- . EWD-N-68-00899-00002 HP Low-E4® Sun (240) 3.1mm / 13mm / 3.1mm 5/8" or 7/8" CDL (no spacer) 1.76 0.31 0.13 0.20 6.N .N .S .S ..A .- .- .- . EWD-N-68-00924-00001 HP Low-E4® Sun (240) 3.1mm / 13mm / 3.1mm 1-1/8" MDL 1.82 0.32 0.12 0.16 4.N .N .S .S ..A .- .- .- . EWD-N-68-00919-00001 HP Low-E4® Sun (240) 3.1mm / 13mm / 3.1mm 1-1/2" MDL 1.82 0.32 0.12 0.16 4.N .N .S .S ..A .- .- .- . EWD-N-68-00899-00003 HP Low-E4® Sun (240) 3.1mm / 13mm / 3.1mm 1-1/8" or 1-1/2" CDL (no spacer) 1.76 0.31 0.12 0.16 5.N .N .S .S ..A .- .- .- . EWD-N-68-00904-00001 HP Low-E4® Sun (240) 3.1mm / 13mm / 3.1mm 5/8" Between-Glass Grilles 1.76 0.31 0.13 0.20 6 .N .N .S .S ..A .- .- .- . EWD-N-68-00909-00001 HP Low-E4® Sun (240) 3.1mm / 13mm / 3.1mm 1" Between-Glass Grilles 1.82 0.32 0.13 0.20 5 .N .N .S .S ..A .- .- .- . EWD-N-68-01156-00001 HP Low-E4® Sun (240) 3.1mm / 13mm / 3.1mm 2-1/4" MDL 1.93 0.34 0.12 0.16 2.- .- .- .-..-.-.-.-. EWD-N-68-00898-00001 SmartSun™ (366) 3.1mm / 13mm / 3.1mm None 1.70 0.30 0.16 0.37 9.N .N .S .S ..A .- .- .- . EWD-N-68-00913-00001 SmartSun™ (366) 3.1mm / 13mm / 3.1mm 5/8" or 7/8" MDL 1.76 0.31 0.14 0.32 7.N .N .S .S ..A .- .- .- . EWD-N-68-00898-00002 SmartSun™ (366) 3.1mm / 13mm / 3.1mm 5/8" or 7/8" CDL (no spacer) 1.70 0.30 0.14 0.32 8.N .N .S .S ..A .- .- .- . EWD-N-68-00923-00001 SmartSun™ (366) 3.1mm / 13mm / 3.1mm 1-1/8" MDL 1.82 0.32 0.12 0.27 4.N .N .S .S ..A .- .- .- . EWD-N-68-00918-00001 SmartSun™ (366) 3.1mm / 13mm / 3.1mm 1-1/2" MDL 1.82 0.32 0.12 0.27 4.N .N .S .S ..A .- .- .- . EWD-N-68-00898-00003 SmartSun™ (366) 3.1mm / 13mm / 3.1mm 1-1/8" or 1-1/2" CDL (no spacer) 1.70 0.30 0.12 0.27 7.N .N .S .S ..A .- .- .- . EWD-N-68-00903-00001 SmartSun™ (366) 3.1mm / 13mm / 3.1mm 5/8" Between-Glass Grilles 1.70 0.30 0.14 0.32 8 .N .N .S .S ..A .- .- .- . EWD-N-68-00908-00001 SmartSun™ (366) 3.1mm / 13mm / 3.1mm 1" Between-Glass Grilles 1.82 0.32 0.14 0.32 5 .N .N .S .S ..A .- .- .- . EWD-N-68-01155-00001 SmartSun™ (366) 3.1mm / 13mm / 3.1mm 2-1/4" MDL 1.87 0.33 0.12 0.27 3.- .- .- .-..-.-.-.-. EWD-N-68-00900-00001 PassiveSun® (180) 3.1mm / 13mm / 3.1mm None 1.76 0.31 0.40 0.45 22.N .N .S .S ..A .- .- .- . EWD-N-68-00915-00001 PassiveSun® (180) 3.1mm / 13mm / 3.1mm 5/8" or 7/8" MDL 1.82 0.32 0.34 0.39 17.N .N .S .S ..A .- .- .- . EWD-N-68-00900-00002 PassiveSun® (180) 3.1mm / 13mm / 3.1mm 5/8" or 7/8" CDL (no spacer) 1.76 0.31 0.34 0.39 18.N .N .S .S ..A .- .- .- . EWD-N-68-00925-00001 PassiveSun® (180) 3.1mm / 13mm / 3.1mm 1-1/8" MDL 1.82 0.32 0.29 0.33 14.N .N .S .S ..A .- .- .- . EWD-N-68-00920-00001 PassiveSun® (180) 3.1mm / 13mm / 3.1mm 1-1/2" MDL 1.87 0.33 0.29 0.33 13.- .- .- .-..-.-.-.-. EWD-N-68-00900-00003 PassiveSun® (180) 3.1mm / 13mm / 3.1mm 1-1/8" or 1-1/2" CDL (no spacer) 1.76 0.31 0.29 0.33 15.N .N .S .S ..A .- .- .- . EWD-N-68-00905-00001 PassiveSun® (180) 3.1mm / 13mm / 3.1mm 5/8" Between-Glass Grilles 1.76 0.31 0.34 0.39 18 .N .N .S .S ..A .- .- .- . EWD-N-68-00910-00001 PassiveSun® (180) 3.1mm / 13mm / 3.1mm 1" Between-Glass Grilles 1.82 0.32 0.34 0.39 17 .N .N .S .S ..A .- .- .- . EWD-N-68-01157-00001 PassiveSun® (180) 3.1mm / 13mm / 3.1mm 2-1/4" MDL 1.93 0.34 0.29 0.33 11.- .- .- .-..-.-.-.-. EWD-N-68-01234-00010 HP Low-E4® HeatLock™ (272/i89) 3.1mm / 13mm / 3.1mm None 1.53 0.27 0.24 0.40 17.N .N .S .S ..A .B .- .- . EWD-N-68-01240-00004 HP Low-E4® HeatLock™ (272/i89) 3.1mm / 13mm / 3.1mm 5/8" or 7/8" MDL 1.70 0.30 0.21 0.34 12.N .N .S .S ..A .- .- .- . EWD-N-68-01234-00011 HP Low-E4® HeatLock™ (272/i89) 3.1mm / 13mm / 3.1mm 5/8" or 7/8" CDL (no spacer) 1.53 0.27 0.21 0.34 16.N .N .S .S ..A .B .- .- . EWD-N-68-01244-00004 HP Low-E4® HeatLock™ (272/i89) 3.1mm / 13mm / 3.1mm 1-1/8" MDL 1.70 0.30 0.18 0.29 10.N .N .S .S ..A .- .- .- . EWD-N-68-01242-00004 HP Low-E4® HeatLock™ (272/i89) 3.1mm / 13mm / 3.1mm 1-1/2" MDL 1.70 0.30 0.18 0.29 10.N .N .S .S ..A .- .- .- . EWD-N-68-01234-00012 HP Low-E4® HeatLock™ (272/i89) 3.1mm / 13mm / 3.1mm 1-1/8" or 1-1/2" CDL (no spacer) 1.53 0.27 0.18 0.29 14.N .N .S .S ..A .B .- .- . EWD-N-68-01236-00004 HP Low-E4® HeatLock™ (272/i89) 3.1mm / 13mm / 3.1mm 5/8" Between-Glass Grilles 1.53 0.27 0.21 0.34 16 .N .N .S .S ..A .B .- .- . EWD-N-68-01238-00004 HP Low-E4® HeatLock™ (272/i89) 3.1mm / 13mm / 3.1mm 1" Between-Glass Grilles 1.65 0.29 0.21 0.34 13 .N .N .S .S ..A .- .- .- . EWD-N-68-01246-00004 HP Low-E4® HeatLock™ (272/i89) 3.1mm / 13mm / 3.1mm 2-1/4" MDL 1.82 0.32 0.18 0.29 8.N .N .S .S ..A .- .- .- . EWD-N-68-01235-00010 SmartSun™ HeatLock™ (366/i89) 3.1mm / 13mm / 3.1mm None 1.53 0.27 0.16 0.36 13.N .N .S .S ..A .B .- .- . EWD-N-68-01241-00004 SmartSun™ HeatLock™ (366/i89) 3.1mm / 13mm / 3.1mm 5/8" or 7/8" MDL 1.65 0.29 0.14 0.31 9.N .N .S .S ..A .- .- .- . EWD-N-68-01235-00011 SmartSun™ HeatLock™ (366/i89) 3.1mm / 13mm / 3.1mm 5/8" or 7/8" CDL (no spacer) 1.53 0.27 0.14 0.31 12.N .N .S .S ..A .B .- .- . EWD-N-68-01245-00004 SmartSun™ HeatLock™ (366/i89) 3.1mm / 13mm / 3.1mm 1-1/8" MDL 1.70 0.30 0.12 0.26 7.N .N .S .S ..A .- .- .- . EWD-N-68-01243-00004 SmartSun™ HeatLock™ (366/i89) 3.1mm / 13mm / 3.1mm 1-1/2" MDL 1.70 0.30 0.12 0.26 7.N .N .S .S ..A .- .- .- . EWD-N-68-01235-00012 SmartSun™ HeatLock™ (366/i89) 3.1mm / 13mm / 3.1mm 1-1/8" or 1-1/2" CDL (no spacer) 1.53 0.27 0.12 0.26 10.N .N .S .S ..A .B .- .- . EWD-N-68-01237-00004 SmartSun™ HeatLock™ (366/i89) 3.1mm / 13mm / 3.1mm 5/8" Between-Glass Grilles 1.53 0.27 0.14 0.31 12 .N .N .S .S ..A .B .- .- . EWD-N-68-01239-00004 SmartSun™ HeatLock™ (366/i89) 3.1mm / 13mm / 3.1mm 1" Between-Glass Grilles 1.65 0.29 0.14 0.31 9 .N .N .S .S ..A .- .- .- . EWD-N-68-01247-00004 SmartSun™ HeatLock™ (366/i89) 3.1mm / 13mm / 3.1mm 2-1/4" MDL 1.82 0.32 0.12 0.26 4.N .N .S .S ..A .- .- .- . EWD-N-68-00957-00001 HP Low-E4® (272) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm None 1.65 0.29 0.23 0.38 14.N .N .S .S ..A .- .- .- . EWD-N-68-00957-00002 HP Low-E4® (272) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm 5/8" or 7/8" CDL (no spacer) 1.65 0.29 0.20 0.32 12.N .N .S .S ..A .- .- .- . EWD-N-68-00957-00003 HP Low-E4® (272) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm 1-1/8" or 1-1/2" CDL (no spacer) 1.65 0.29 0.17 0.27 11.N .N .S .S ..A .- .- .- . EWD-N-68-00958-00001 HP Low-E4® (272/272) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm None 1.48 0.26 0.21 0.33 17.N .N .S .S ..A .B .- .- . EWD-N-68-00958-00002 HP Low-E4® (272/272) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm 5/8" or 7/8" CDL (no spacer) 1.48 0.26 0.18 0.28 15.N .N .S .S ..A .B .- .- . EWD-N-68-00958-00003 HP Low-E4® (272/272) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm 1-1/8" or 1-1/2" CDL (no spacer) 1.48 0.26 0.16 0.24 14.N .N .S .S ..A .B .- .- . EWD-N-68-00960-00001 SmartSun™ (366) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm None 1.59 0.28 0.15 0.34 11.N .N .S .S ..A .B .- .- . EWD-N-68-00960-00002 SmartSun™ (366) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm 5/8" or 7/8" CDL (no spacer) 1.59 0.28 0.13 0.29 10.N .N .S .S ..A .B .- .- . EWD-N-68-00960-00003 SmartSun™ (366) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm 1-1/8" or 1-1/2" CDL (no spacer) 1.59 0.28 0.12 0.24 9.N .N .S .S ..A .B .- .- . EWD-N-68-00961-00001 SmartSun™ PassiveSun® (366/180) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm None 1.48 0.26 0.15 0.33 13.N .N .S .S ..A .B .- .- . EWD-N-68-00961-00002 SmartSun™ PassiveSun® (366/180) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm 5/8" or 7/8" CDL (no spacer) 1.48 0.26 0.13 0.28 12.N .N .S .S ..A .B .- .- . EWD-N-68-00961-00003 SmartSun™ PassiveSun® (366/180) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm 1-1/8" or 1-1/2" CDL (no spacer) 1.48 0.26 0.11 0.23 11.N .N .S .S ..A .B .- .- . EWD-N-68-00962-00001 PassiveSun® (180/180) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm None 1.48 0.26 0.33 0.40 24.N .N .S .S ..A .B .- .- . EWD-N-68-00962-00002 PassiveSun® (180/180) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm 5/8" or 7/8" CDL (no spacer) 1.48 0.26 0.28 0.34 21.N .N .S .S ..A .B .- .- . EWD-N-68-00962-00003 PassiveSun® (180/180) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm 1-1/8" or 1-1/2" CDL (no spacer) 1.48 0.26 0.24 0.29 19.N .N .S .S ..A .B .- .- . EWD-N-68-00959-00001 HP Low-E4® PassiveSun® (272/180) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm None 1.48 0.26 0.22 0.36 17.N .N .S .S ..A .B .- .- . EWD-N-68-00959-00002 HP Low-E4® PassiveSun® (272/180) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm 5/8" or 7/8" CDL (no spacer) 1.48 0.26 0.19 0.31 16.N .N .S .S ..A .B .- .- . EWD-N-68-00959-00003 HP Low-E4® PassiveSun® (272/180) TIG 3.1mm / 8mm / 3.1mm / 8mm / 3.1mm 1-1/8" or 1-1/2" CDL (no spacer) 1.48 0.26 0.17 0.26 14.N .N .S .S ..A .B .- .- . Data is accurate as of 10/7/13 and is subject to change. See page 1 for more information. I/S French Door, HP Sill, SP1 panel U-Factor1(W/m2*K)Product TypeAndersen® Product Line CPD Number Canada ENERGY STAR 2010U.S. ENERGY STAR2010 Canada ERVTSHGCU-Factor1 (BTU/hr*ft2*°F)Divided Light OptionsGlass Type Page 2 of 2