Loading...
HomeMy WebLinkAboutE3.0 Electrical One Line and Schedules.pdf 1. 1 PANEL 1-I IA' KITCHEN EQUIPMENT SCHEDULE LIGHTING FIXTURE SCHEDULE VOLTAGE L-L: 208 LOCATION: WORK ROOM KEY DESCRIPTION VOLTS PH LOAD CONNECTION SHUNT FEEDER CIRCUIT NOTES TYPE DESCRIPTION MANUFACTURER CATALOG NUMBER VOLTAGE LAMP MAX MOUNTING INFORMATION NOTES VOLTAGE L-G: 120 BUS RATING: 225 AMP HP,KW,FLA REGEPT. DISC. OTHER TRIP QTY WATT TYPE WATTS LOCATION BOF/RFD/OFH TYPE: 3PH/4W MAIN GB: 200A/3P M.G.B. K REFRIGERATED EQUIPMENT 120 I 5.1A 5-20R X 2#12, I#126, I/2"G 1-116-40 A Al RECESSED DOWNLIGHT JUNO IC22LWDG3-3K-I-24W-WH 120 I 25 LED 25 RECESSED 5-1/2" RFD I MOUNTING: SURFACE S.G. RATING: 42K AIG FULLY RATED 5 STAND (SHUNT TRIP) (SHUNT TRIP) CEILING NOTES: EXISTING FED FROM: MAIN DISCONNECT K GOOK HOLD OVEN 208 I 24A 6-30R X 2#10, I#TOG, 3/4"G 1-IIB-2q,31 A E ATOMIC, WIRE GUARD STEM BARN LIGHT CODE: BLE-S-W66WH-PC 120 I 40 INGAN 40 PENDANT RE:ARGH 6 (SHUNT TRIP) _ (SHUNT TRIP) _MOUNT PENDANT(CLEAR GLASS) ELECTRIC 100-BLACK,BLACK STEM CEILING GIR. GGT LOAD LOAD GIRGUIT BRKR BUS GIRGUIT BRKR LOAD LOAD GGT GIR K COFFEE BREWER 120 I 25.8A 5-30R 2#10, I#IOC,3/4°C 1-116-16 H HOOD LIGHT -- INTERGRAL WITH EQUIPMENT -- -- -- -- -- -- -- NO TYPE VA DESCRIPTION POLE TRIP TRIP POLE DESCRIPTION VA TYPE NO 8 I E 564 MUA-1 3 20 A 60 2 FAN COIL 50,16 M 2 K COFFEE GRINDER 120 I 5.1A 5-20R 2#12, 1#126, 1/2°C 1-115-10 L RECESSED DOWNLIGHT JUNO IC22LWD63-3K-I-2330H-WH 120 I 25 LED 25 CEILING 10-1/2" RFD 3 E 564 -- -- -- B -- -- -- 50,16 M 4 qKITCHEN RECESSED 5 E 564 -- G 60 2 FAN COIL 50,1 _6 M 6 K MICROWAVE CONVECTION 206 I 40A 6-50R X 2#6, 1#106, I"G 1-115-23,25 T1 TRACK LIGHTING JUNO T254L-35K-N-XX 120 I Iq LED Iq TRACK RE:ARCH 2,3 1 KE 240 KEH-I I 20(*) A -- -- -- 50,16 M 8 10 OVEN (SHUNT TRIP) 8.3kh (SHUNT TRIP) CEILING o rq w x E ,n O U m$q KE 2400 K-54 I 3O(*) B 30 3 WALK IN COOLER 2521 KE 10 K ESPRESSO MACHINE 208 I SkW X 2#6, I#IOC, I"G 1-IIB-11,11 I 51 SURFACE MOUNT FLUORESCENT LUMAX LIGHTING GL-23248-E015A 120 2 32 TS 6c1 RECESSED 6-I/2" RFD m r\15 � o II M 2704 FAN COIL 2 30 G -- -- -- 2521 KE 12 # p > J Z 15 CORRIDOR FIXTURE CEILING oo - 13 M 2704 -- -- -- A -- -- -- 2521 KE 14 _ K REACH IN UNDER COUNTER 120 I 3.qA 5-20R 2#12, 1#126, I/2"G 1-116-10 X2 COMBO EXIT LIGHT CHLORIDE VGTL3GW 120 2 5.4 TUNGSTEN 12 8' AFF .`1-'' o m m '� Fe 15 E 360 WH-2 I 20 5 30 3 CONDENSING UNIT 2282 E Ib Ib REFRIGERATOR SURFACE t^ m e C W Il E 25 P-I 1 20 G -- -- -- 2282 E 18 K ESPRESSO GRINDER 120 I 800W 5-20R 2#12, I#126, 1/2°C 1-II5-8 YI EMERGENCY LIGHT CHLORIDE VT6 120 2 5.4 TUNGSTEN 12 6' AFF 0 qj 7, u Iq _ E 208,1 Il 1-11B-I2 SURFACE CONDENSING UNIT 3 25 A -- -- -- 2282 E 20 v 0 61 a' a' Z Z 21 E 208,1Y U N N B 20 2 SPARE 22 _K BLENDER VITAMIX 120 I II.5A 5-15R 2#12, I#126, 1/2°C 1-118-6 EHI EXTERIOR HALL SGONGE WITH AGGULITE DT-A011-35K-E12-BL-EM 120 I 22 LED 22 HALL RE: ARCH 2,4 t^ r^ r" (Sid' z Lj 23 E 208H -- -- -- G -- -- -- 24 20 1-11B-41 EMERGENCY BACKUP JUNO SURFACE N > o en 1 LU D 25 E 400 BUILDING MOUNT SIGN 1 20(*) A 20 I EF-2 68 E 26 K REACH IN UNDER COUNTER 120 1 3.qA 5-20R 2#12, I#126, I/2"G 1-IIB-10 ABBREVIATIONS: BOF - BOTTOM OF FIXTURE, RFD - RECESSED FIXTURE DEPTH, OFH - OVERALL FIXTURE HEIGHT 'u 0 J CQ 27 _ KE 1440 K-5I I 20(*) 5 25 3 KEF-I A325 KE 28 21 REFRIGERATOR, 2 SECTION GENERAL NOTES: o Q ,n 2q _ M 2704 FAN COIL 2 30 G -- -- -- 325 KE 30 K GONE BAKER 120 I IIA 5-2oR 2#12, 1#12G, I/2"C 1-IIB-3q A. ALL FLUORESCENT LAMPS TO BE 3500K COLOR TEMPERATURE AND A MINIMUM OF 82GRI, UNLESS NOTED OTHERWISE. 0 p� V 01 31 M 2704 -- -- -- A _ 22 B. ALL REFLECTOR LAMPS TO BE PROVIDED AS HIDE FLOOD DISTRIBUTION, UNLESS NOTED OTHERWISE. Z 33 KE 1440 K-5I 1 20(*) B 100 3 SUB PANEL 'E' 1080 5 34 K ICE CREAM DIPPING 120 I IAA 5-15R 2#12, 1#12G, I/2"C 1-1113-18 G. ALL FLUORESCENT LUMINAIRES THAT UTILIZE DOUBLE-ENDED LAMPS AND CONTAIN BALLASTS THAT GAN BE SERVICED IN PLAGE SHALL HAVE A I— u 35 KE 1425 K-53 2 20(*) G -- -- -- 3360 5 36 31 CABINET DISCONNECTING MEANS AS DESCRIBED IN NEC 410.130(G). r • 111 U — 3l KE 1425 -- -- -- A -- -- -- 3360 S 38 K HOT FOOD SERVING 208 I ISA 30A/2P 2#12, 1#12G, I/2"C 1-116-36,38 I ''• :•W In 3q KE 2400 K-51 I 30(*) B ► ;.di'.... = 32 COUNTER SPECIFIC NOTES: SIMI— Q 41 KE 1524 K-50 I 20(*) G 20 I BASEBOARD HEATER 1000 E 42 K REFRIGERATED SANDWICH 120 I I0.3A 5-20R 2#12, 1#12G, I/2"0 1-116-14 1 EG SHALL VERIFY LENSED TRIM OPTIONS WITH OWNER/ARGHITEGT PRIOR TO PURCHASE. ' _ 33 UNIT 2. EG SHALL VERIFY FINISH COLOR HITH ARCHITECT/OWNER PRIOR TO PURCHASE. 00 .:U GGT TYPE: L=LIGHTING,R=RECEPTACLE,M=MOTOR,LM=LARGEST MOTOR,E=EQUIPMENT,KE=KITGH EQUIP,S=SUBFEED PANEL K TGE GUBER WITH BIN 208 I 18.2 30A/2P 2#10, MOS,3/4"C E-'1,11 3. EG SHALL PROVIDE ALL PART AND PIECES NEGE55ARY FOR FULLY FUNCTIONAL TRACK SYSTEM INCLUDING, BUT NOT LIMITED TO, TRANSFORMERS, POWER FEEDS, 1 OCT TYPE: LOAD MULT DEMANDED LOAD TOTAL CONNECTED LOADS -.. Q LIGHTING: 0 1.25 OVA A B C 35 STANDOFFS,CONNECTORS, ETC. K P05 • _ _-" • '., - • 4. EG SHALL VERIFY WITH ARCHITECT NEED FOR EXTERIOR EMERGENCY FIXTURE. IF NEEDED CONFIRM SPECIFICATION WITH ARCHITECT PRIOR TO ROUGH-IN. RECEPTACLE: 0 1.0 OVA VA 28814 23111 2561'1 36 E-5, E-1 5. EG SHALL PROVIDE EACH TRACK LENGTH HITH JUNO #TCL2 2AMP CURRENT LIMITING DEVICE PER NEC 220.43(6). .0""."''■. OVER 10K: 0 0.5 0 VA TOTAL DEMANDED LOADS ■■■ REG '•y. K DROP IN HOT HELL 120 I 6.1A 5-2oR 2#12, 1#120, 1/2"G 1-IIB-20 •0 Q MOTOR: 31200 1.0 31200 VA A B G ++ - LGST MOTOR: 0 1.25 0 VA VA 21215 Ig483 235'41 40 1-IIB-22 �.• K TGE GUBER FOR FREESTYLE 120 I 12.1A 5-20R 2#12, 1#126, I/2"G 1-IIA-41 ! ` •• . 1.r EQUIPMENT: 16658 1.0 16658 VA AMPS 221 162 KM50 y r 1 �...[n": KITGH EQUIP: 22632 0.65 14111 VA TOTAL ON 10 KVA K FROZEN DRINK MACHINE 120 I 12A 5-15R 2#12, 1#126, I/2"G 1-IIA-21 (E) (E) (E) (N) : ( 1 . 5$37 --1 a SUBFEED PNL: 1800 1.0 1800 VA PANEL: I'15 AMPS Z; K REACH-IN FREEZER, 208 I 14.4A 14-20R 2#12, 1#126, I/2"G 1 I113 24,26 /(E) I � NOTES: (E) PAD MOUNTED UTILITY 6/20/14,./p 52 3 SECTIONS 1-IIB-283o PANEL PANEL PANEL I. BOLD LINEWEIGHT INDICATES NEH OR REVISED LOAD/GIRGUITING. TRANSFORMER 'A' .• 1-IIB-3234 B 1E a'QNA� ,• LIGHT LINEHEIGHT INDICATES EXISTING TO REMAIN LOAD/CIRCUITING. 120/208V, 3�, 4W �� — — —1 •'•. c. .• (*) PROVIDE NEW GIRGUIT BREAKER, AIG RATING AND MANUFACTURE TO MATCH EXISTING. K OPEN MERCHANDISER 208 I 13.7A 6-20R 2#12, 1#12G, I/2"C 7-IIA-35,31 (E) F5 F3 �(N) '••,•• •+ K COKE MACHINE BY 120 I 20A 5-20R 2#10, 1#10G,3/4"C 1-IIA-q MAIN DISCONNECT IOONCS 54 VENDOR 600A/3P, I (E) ^F2 F4 J K BAG-IN-BOX 120 1 ISA 5-20R 2#12, 1#126, I/2"G 1-IIA-40 I 208/120V, 30, 4W UTILITY O PANEL '7-IIB 55 NEMA 3R , M 1 METER O VOLTAGE L-L: 208 LOCATION: WORK ROOM K OUTSIDE ICE STORAGE UNIT 120 I 2400W X 2#10, I#TOG,3/4"C 1-IIA-3q I I �� GT CABINET VOLTAGE L-6: 120 BUS RATING: 225 AMP 51 - I (E) 1 (ND TYPE: 3PH/4H MAIN GB: 200A/3P.G.B. GENERAL NOTES: • • FI '� MOUNTING: SURFACE S.G. RATING: 42K AIG FULLY RATED A. FOR HOODS PROVIDED WITH FIRE SUPPRESSION SYSTEM, ALL ELEGTRIGAL EQUIPMENT UNDER HOOD SHALL BE NOTES: EXISTING FED FROM: MAIN DISCONNECT CONNECTED TO A SHUNT TRIP STYLE CIRCUIT BREAKER. ACTIVATION OF FIRE SUPPRESSION SYSTEM SHALL OPEN _I I A I SHUNT TRIP GIRGUIT BREAKERS OF EQUIPMENT LOCATED UNDER HOOD. PROVIDE 120V POWER TO ALL SOLENOID "FO I (E) Z GIR. GGT LOAD LOAD GIRGUIT BRKR BUS GIRGUIT BRKR LOAD LOAD GGT GIR VALVES. TIE SUPPRESSION SYSTEM INTO FIRE ALARM CONTROL PANEL AS REQUIRED. E.G. TO PROVIDE CONTROL NO TYPE VA DESCRIPTION POLE I TRIP TRIP POLE DESCRIPTION VA TYPE NO WIRING FOR GAS SHUTDOWN SOLENOID FOR GAS OPERATED EQUIPMENT LOCATED BELOW HOOD. = I I R 120 FRONT REG. I 20 A 20 I BLDG LIGHTS 1120 L 2 B. ELECTRICAL GONTRAGTOR 15 TO PROVIDE AND INSTALL LAMPS AND SWITCHING FOR FIXTURES INTEGRAL TO 3 R 540 MAIN FLOOR REG. I 20 B 20 I COFFEE GRINDER 1000 E 4 KITCHEN EQUIPMENT. M Q 5 R 120 BACK REG. I 20 G 20 I K-20 1380 KE 6 G. PRIOR TO ROUGH-IN, REFER TO KITCHEN EQUIPMENT SHOP DRAWINGS FOR FINAL GONNEGTION REQUIREMENTS 11..1 1 L 500 VAULT COOLER LIGHTS I 20 A 20 I K-Il 800 KE 8 INCLUDING ROUGH-IN HEIGHTS AND LOCATIONS,SPECIFIC POWER REQUIREMENTS, AND REGEPTAGLE NEMA 2 —I (E) I— I (E) q L 803 KITCHEN,BACK LIGHTS I 20 B 20 I K-21,K-I6,K-q 1620 KE 10 - CONFIGURATIONS. Q WIfl II L 1404 MAIN FLOOR LIGHTS 6,11 20 G 20 1 K-Il 800 KE 12 D. PROVIDE ALL REQUIRED J-BOXES, OUTLETS, AND DISCONNECTS REQUIRED FOR A COMPLETE INSTALLATION. (E)PRIMARY BYLO 13 L 1240 MAIN FLOOR LIGHTS E,H I 20 A 20 I K-33 1236 KE 14_ E. WHERE REFRIGERATION LINES REQUIRE HEAT TAPE, TAPE AND FINAL GONNEGTION TO 120V GFGI CIRCUIT UTILITY COMPANY ine V 15 _ L Ig20 OUTSIDE LIGHTS I 20 B 40(*) I K-8 3016 KE 16 SHALL BE PROVIDED BY E.G. < 1 CO 11 KE 4000 K-I5 2 50(*) G 20 I K-31 q48 KE 18 F. ELECTRICAL GONTRAGTOR SHALL PROVIDE CONTROL HIRING FOR EXHAUST FAN AND MAKE-UP AIR FAN INTERLOCK Iq _ KE 4000 -- -- -- A 20 I K-40,K-40 1608 KE 20 AS REQUIRED BY THE MEGHANIGAL/KITCHEN CONTRACTOR. U Z 0 21 L 1080 MAIN FLOOR LIGHTING 1 I 20 B 20 I K-40,K-40 1608 KE 22 G. DEVICE FACEPLATES ARE TO BE STAINLESS STEEL. 23 KE 4150 K-10 2 50(*) G 20(*) 2 K-52 1500 KE 24 H. ALL 15 OR 20 AMP RECEPTACLES WITHIN THE KITCHEN ARE TO BE GFGI TYPE. FOR ALL DEVICES COVERED BY EQUIPMENT PROVIDE GFI TYPE BREAKER. 1 EXISTING ONE-LINE D IAG RAMW O U 25 _ KE 4150 -- -- -- A -- -- -- 1500 KE 26 21 _ SHUNT TRIP B 20(*) 2 K-52 1500 KE 28 SPECIFIC NOTES: E3.0 SCALE: N.T.S. Q LL. —I 2q KE 24'16 K-b 2 30(*) G -- -- -- 1500 KE 30 I EG SHALL COORDINATE RECEPTACLE CONFIGURATION WITH EQUIPMENT PRIOR TO INTALLATION. 31 KE 2416 -- I -- -- A 20(*) 2 K-52 1500 KE 32 Z 33 SHUNT TRIP B -- -- -- 1500 KE 34 — > ..- 20 G 20(*) 2 K-32 1560 KE 36 Cs.sSI ' - 20 B 20 I K-5 684 KE 40 MECHANICAL EQUIPMENT SCHEDULE LOAD SUMMARY GENERAL NOTES (Ni 41 KE 1380 K-20 20 G SHUNT TRIP 42 KEY DESCRIPTION VOLTS PH LOAD MOGP/ FEEDER DISGONNEGT GIRGUIT NOTES NJ GGT TYPE: L=LIGHTING, R=RECEPTACLE,M=MOTOR,LM=LARGEST MOTOR,E=EQUIPMENT, KE=KITCH EQUIP, S=SUBFEED PANEL {-1P,KA MFS MAIN DISCONNECT(600Al3P,208/120V,3P1-1,414) I. ALL EQUIPMENT SHOWN ON ELECTRICAL GGT TYPE: LOAD MULT DEMANDED LOAD TOTAL CONNECTED LOADS FC FAN COIL 208 I 4gMGA 60A EXISTING EXISTING 1-IIA-2,4 2 LOAD ON PANEL 1-IIA 10 KVA ONE-LINE IS EXISTING TO REMAIN. SHOWN FOR CeLIGHTING: '1551 1.25 11'446 VA A B G I (EXISTING) 208 I 26MGA 30A EXISTING EXISTING 1-IIA-11,13 LOAD ON PANEL 1-IIB 41 KVA INFORMATIONAL PURPOSES ONLY. RECEPTACLE: Ig80 1.0 1'180 VA VA 23230 16611 22528 FG FAN COIL 208 I 4cIMGA 60A EXISTING EXISTING 1-IIA-6,8 2 TOTAL LOAD ON MAIN DISCONNECT 118 KVA OVER 10K: 0 05 0 VA TOTAL DEMANDED LOADS 2 (EXISTING) 208 1 26MGA 30A EXISTING EXISTING 1-IIA-21,31 LOAD AT 208V/3PH 321 AMPS 0 MOTOR: 0 1.0 0 VA A B G GU CONDENSING UNIT 208 3 I'1A 30A EXISTING EXISTING 1-IIA-16,18,20 2 MAIN DISCONNECT 15 RATED 600A @ 208V/3PH, THEREFORE LGST MOTOR: 0 1.25 0 VA VA 11548 13651 16152 I (EXISTING) DETAIL NOTES EQUIPMENT: 1000 1.0 1000 VA AMPS 146 114 135 GU CONDENSING UNIT 208 3 11.4 25A EXISTING EXISTING 1-IIA-Iq,21,23 2 THE LOAD IS JUSTIFIEDZ KITGH EQUIP: 4g8g2 0.65 32430 VA TOTAL ON 47 KVA 2 (EXISTING) O EG TO DISCONNECT EXISTING PANEL 'E' FROM SUBFEED PNL: 0 1.0 0 VA PANEL: 131 AMPS MUA MAKE-UP AIR UNIT 208 3 4.1A 20A 3#12, I#12G, 3/4"G HOOD 1-IIA-1,35 CIRCUIT FED FROM 60A/2P BREAKER ON 1 PANEL PANEL A AND REPLACE WITH NEW 42CKT, NOTES: KEH KITCHEN HOOD 120 I 2A 20A 2#12, I#12G, I/2"G $TO 1-IIA-1 1 I. BOLD LINEHEIGHT INDICATES NEH OR REVISED LOAD/GIRGUITING. I25A PANEL LABELED 'E'. EC TO PROVIDE W o LIGHT LINEWEIGHT INDICATES EXISTING TO REMAIN LOAD/GIRGUITING. KEF KITCHEN EXHAUST FAN 208 3 2.1A 20A 3#12, 1#12G, 3/4"G HOOD 1-IIA-28,30,32 NEW I00A/3P BREAKERS TO REPLACE H n NI- (*) PROVIDE NEW CIRCUIT BREAKER, AIC RATING AND MANUFACTURE TO MATCH EXISTING. I (GREASE) PANEL SCHEDU BREAKER AS SHOWN ON THE PANEL SCHEDULE. WIRE PANEL 'E' TO PANEL 'A' WITH 0 EF BATHROOM EXHAUST FAN 120 I .IBA 20A 2#12, I#126, I/2"G $TO 1-IIB-q 3 4#I, I4$80, I-I/2"G COPPER WIRE. NEW PANEL 1 'E' TO BE SURFACE MOUNTED AND LOCATED o EF ICE MACHINE EXHAUST FAN 120 I .56A 20A 2#12, I#126, I/2"G $TO 1-IIA-26 4 N IN HALL 103 AS SHOWN ON ELECTRICAL Z o PANEL 'E' 2 PLANS. O_ EBH ELECTRIC BASEBOARD 120 I 1000W 20A EXISTING EXISTING 1-IIA-42 2 VOLTAGE L-L: 208 LOCATION: HALL 103 P Z I HEATER (EXISTING) a Q VOLTAGE L-G: 120 BUS RATING: 125 AMP WH NEW GAS-FIRED HATER 120 I 3A 20A 2#12, 1#12G, I/2"G $TO 7-IIA-25 IY TYPE: 3PH/41,4 MAIN GB: M.L.O. Vi 2 HEATER MOUNTING: SURFACE S.G. RATING: 22K AIG FULLY RATED P PLUMBING PUMP 120 I 25W 20A 2#12, I#12G, I/2"G $TO 1-IIA-21 w w 3 NOTES: NEW FED FROM: 100A/3P BREAKERS (A-34,36,38) I 0 Ce a t.i GENERAL NOTES: W GIR. CGT LOAD LOAD CIRCUIT BRKR BUS CIRCUIT BRKR LOAD LOAD GGT GIR j A. REFER TO MECHANICAL PLANS FOR SPECIFIC EQUIPMENT LOCATIONS AND REQUIREMENTS. NO TYPE VA DESCRIPTION POLE TRIP TRIP POLE DESCRIPTION VA TYPE NOB. PRIOR TO ROUGH-IN,COORDINATE ALL MECHANICAL EQUIPMENT POWER AND CONNECTION REQUIREMENTS HITH W I E 360P05 I *1 20 A 20 *1 TV MENUS 360 E 2 MECHANICAL CONTRACTOR'S FINAL SHOP DRAWINGS. 5 0 3 E 360 POS 2 *1 20 B 20/20 I/I SPARE 4 CO G. PROVIDE ALL 120V CONTROL HIRING, REFER TO SPECIFICATIONS FOR FURTHER CONTROL WIRING GLARIFIGATION. 5 E 360 P05 3 *1 20 G BUSSED SPACE 6 D. EXTERIOR DISCONNECT SWITCHES ARE TO BE PROVIDED AS NEMA 3R EQUIPMENT UNLESS OTHERWISE NOTED. i i Q l E 360 P0S 4 *1 20 A BUSSED SPACE 8 E. PROVIDE WEATHERPROOF 120 VOLT GFGI RECEPTACLES WITHIN 25' OF ALL ROOFTOP HEATING,VENTILATING, AND AIR o Z (3- m 1- q KE 3000 K-35 2 30 B BUSSED SPACE 10 W CONDITIONING EQUIPMENT. GIRGUIT TO SPARE GIRGUIT ON NEAREST 120V PANELBOARD OR AS INDICATED ON PLANS. z o = II KE 3000 -- -- -- G BUSSED SPACE 12 o O N v F. PROVIDE DUCT DETECTION ON ALL RETURN AIR SYSTEMS OF 2,000 GFM OR GREATER, AND FOR ALL SUPPLY AIR 1 1 13 A 14 SYSTEMS 15,000 CFM OR GREATER, INCLUDING THOSE SYSTEMS SERVING MULTIPLE FLOORS. PROVIDE ADDITIONAL N io IS B lb W DUCT DETECTORS AND INSTALL REMOTE INDICATOR LIGHTS A5 REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. o Ii G 18 Q o Iq A 20 SPEGIFIG NOTES: g 0 21 B 22 I. EG SHALL VERIFY KITCHEN HOOD SWITCHING REQUIREMENTS. PROVIDE REQUIRED SWITCH IF NECESSARY. cC 23 G 24 2. EQUIPMENT 15 EXISTING, ALL EXISTING CIRCUITING SHALL REMAIN. a W 25 A 26 3. FAN TO BE CONTROLLED WITH OCCUPANCY SENSOR IN RESTROOM. COORDINATE ANY REQUIREMENTS WITH MECHANICAL W 27 B 28 GONTRAGTOR PRIOR TO ROUGH-IN. i m ,_-• 1 2a C 30 4. FAN TO BE CONTROLLED BY THERMOSTAT WITHIN SPACE. COORDINATE ANY REQUIREMENTS HITH MEGHAINGAL GONTRAGTOR. u z o 0 0 31 _ A 32A in 33 B 34 .. ,.,„w o g ,„ ., L, 1 35 G 36 N N 31 A 38 Copyright c 2010-All rights reserved 0 3q B 40 FAULT CURRENT CALCULATION SCHEDULE _ _ Architectural Engineering Design Group,Inc. 41 G 42 POINT LOCATION LENGTH(L) VOLTAGE VOLTAGE PHASE HIRE CONDUCTOR CONDUCTOR CONDUIT VOLTAGE C #OF PARALLEL Isc AVAILABLE f M Isc POINT All design drawings and written material N DESCRIPTION (ft) (EL-L) (EL N) SIZE MATERIAL TYPE MATERIAL CLASS VALUE RUNS UPSTREAM L-L L-L AT EQUIP herein may not be used or duplicated without the written consent of Architectural mi aGGT TYPE: L=LIGHTING, R=RECEPTACLE, M=MOTOR,LM=LARGEST MOTOR,E=EQUIPMENT,KE=KITGH EQUIP,S=SUBFEED PANEL (13ph) OR(IL-L) Engineering Design Group,Inc. W CCT TYPE: LOAD MULT DEMANDED LOAD TOTAL GONNEGTED LOADS FO UTILITY XFMR -- -- -- -- -- -- 52,000 FO C0 LIGHTING: 0 1.25 0 VA A B G Fl MAIN DISC. 50 208 120 3 350 COPPER THREE SINGLE CONDUCTORS NONMAGNETIC 600V 22736 2 52,000 0.48 0.68 35,226 Fl 1 RECEPTACLE: 0 1.0 0 VA VA 1080 3360 3360 F2 GT CABINET 15 208 120 3 350 COPPER THREE SINGLE CONDUCTORS NONMAGNETIC 600V 22736 2 35,228 0.10 0.11 32,120 F2 ? OVER IOK: 0 0.5 OVA TOTAL DEMANDED LOADS F3 PANEL 'A' 5 208 120 3 3X COPPER THREE SINGLE CONDUCTORS STEEL 600V 12843 I 32,120 0.10 0.91 21,010 F3 '0 MOTOR: 0 1.0 0 VA A B C F4 PANEL 'E' 10 208 120 I 4 COPPER THREE SINGLE CONDUCTORS STEEL 600V 3806 I 21,090 0.73 058 16,767 F4 C9 LGST MOTOR: 0 1.25 OVA VA 1080 3360 3360 F5 PANEL 'B' 5 208 120 3 3X 1 COPPER THREE SINGLE CONDUCTORS STEEL 600V 12843 I 32,120 0.10 0.91 29,090 F5 a EQUIPMENT: 1800 1.0 1800 VA AMPS q 28 28 NOTES: cn KITGH EQUIP: 6000 I 6000 VA TOTAL ON 8 KVA0 -c I. ALL CALCULATIONS HERE DONE USING BUSSMAN "POINT-TO-POINT" METHOD. SUBFEED PNL: 0 1.0 OVA PANEL: 22 AMPS 2. REFER TO PLANS FOR ASSUMED UTILITY TRANSFORMER SIZE UTILIZED FOR CALCULATIONS. Z 1 NOTES: Q I. BOLD LINEWEIGHT INDICATES NEH OR REVISED LOAD/GIRGUITING. J O LIGHT LINEHEIGHT INDICATES EXISTING TO REMAIN LOAD/CIRCUITING. Q L�„I w (*) PROVIDE NEW GIRGUIT BREAKER, AIG RATING AND MANUFACTURE TO MATCH EXISTING. / , Z J NA V I0 W 0 W = c, w Z c c' W O V) 0 a c SHEET NO.' L. lb .c a L. E3 • 0 U i. .__U L Q