Loading...
HomeMy WebLinkAbout4289 Nugget Lane-deck A3.pdfA3 4EAST ELEVATION -- DEMO WALLS, DOOR AND SIDING. SAVE FOR FUTURE SHED WALLS REMOVE AND REPLANT SMALL TREE PER OWNERS DIRECTION MULCH/NATIVE AREA NOTE: ADD ALTERNATE TO REMOVE TREE AND PREP FOR HOT TUB. HOT TUB BASE TO BE SUNKEN PIT WITH CENTER DRAIN MORTAR SET FLAGSTONE OVER CONCRETE TO REMAIN DEMO BOILER FLUE EXHAUST COVER AND SAVE FOR FUTURE USE 50' STREAM SETBACK LINE A3 8 1 - HOT TUB EXISTING STORAGE A3 4EAST ELEVATION POUR CONCRETE @ NEW SHED EXTENSION ADD ALTERNATE TO SET FLAGSTONE TO MATCH 11' - 0" 4' - 9" 6' - 3" STUB OUT FOR FUTURE HOT TUB ELECTRICAL ELECTRICAL CONDUIT FOR FUTURE HOT TUB ELECTRICAL CONDUIT AT WALL THEN TO NEW TRENCH FOR FUTURE HOT TUB NOTE: ADD ALTERNATE TO INSULATE WATER PIPES IN SHED FOR FREEZE PROTECTION NEW W6 STEEL BEAM ABOVE TO SUPPORT NEW DECK EXTENSION PACK HOLE @ WALL @ BOILER FLUE WITH NON SHRINK GROUT REPLANT SMALL TREE PER OWNERS DIRECTION MULCH/NATIVE AREA NOTE: ADD ALTERNATE TO REMOVE TREE AND PREP FOR HOT TUB. HOT TUB BASE TO BE SUNKEN PIT WITH CENTER DRAIN. 6" CONCRETE WALL WITH 6" OF STONE. ELECTRICAL PANEL FOR FUTURE HOT TUB MORTAR SET FLAGSTONE OVER CONCRETE HOT TUB EXISTING LAMP TO REMAIN INTERIOR OF HOUSE GAS FOR FIRE PIT FUTURE GAS PIT - -HOT TUB ELEVATION50' STREAM SETBACK LINE A3 8 1 - HOT TUB6' - 0 3/4"6' - 1" 2' - 0 7/8"8' - 11 1/2" 8' - 11 1/2"65 SF STORAGE 207 A3 4EAST ELEVATION OTHER HALF OF DUPLEX EXISTING DECK -- EXISTING RAILING TO BE REMOVED AND REUSED WITH NEW RAILING REUSED RAILING PORTION ADD 90 DEGREE TURN AND REUSED EXISTING RAILING PORTION IF POSSIBLE 3' - 0" NEW 3'-0" DECK EXTENSION 3' - 0"BOILER EXHAUST @ ROOF OF SHED SHINGLED ROOF PARTITION WALL TO REMAIN AS-IS NEW HOT TUB LOCATION @ LEVEL BELOW - --- RIP TOP OF FRAMING OVER SHED TO 1/8" PER FOOT. ALLOW ROOM FOR W.P MEMBRANE OVER 1/2" PLYWOOD OVER FRAMING. INSTALL LEVEL SLEEPERS OVER W.P MEMBRANE FOR DECKING. NEW DECKING PER OWNERS DIRECTION NEW STRUCTURAL FRAMING SCABBED TO EXISTING 2X FRAMING FOR 3'-0" EXTENSION 7 A3 NEW FLAGSTONE INFILL OVER SLAB ON GRADE 3'-0" MIN. 50' STREAM SETBACK 13' - 9"EXISTING/DEMO LOWER LEVEL FLOORPLAN 7411' - 1 1/2" MAIN LEVEL DEMO & NEW FLOORPLAN 7419' - 0" 7' - 0 1/2"6' - 4"6' - 0" ROOF TO MATCH PITCH OF DIVISING WALL RAILING TO BE REUTILIZED W6 STEEL BEAM TO SUPPORT DECK EXTENSION SCISSOR 2X10 RAFTER ONTO EXISTING DECK RAFTER WITH TIMBERLOCK SCREWS MIN. OF 6" O.C NOTCH 2X10 RAFTER 1" TO MAINTAIN 6'-8" CLR. HEAD HEIGHT BOILER FLUE EXHAUST OUT ROOF OF SHED FUTURE FIRE PIT RIP TOP OF FRAMING OVER SHED TO 1/8" PER FOOT. ALLOW ROOM FOR W.P MEMBRANE OVER 1/2" PLYWOOD OVER FRAMING. INSTALL LEVEL SLEEPERS OVER W.P MEMBRANE FOR DECKING A3 7 0' - 0 1/2" 2X DECKING PER OWNER 2X SLEEPER RIPPED TO LEVEL DECK W.P MEMBRANE OVER 1/2" PLYWOOD OVER RIPPED DECK FRAMING 1X4 FASCIA BOARD ATTACHED TO SLEEPER FRAMING FLASHING DRIP EDGE 2X RIM JOIST RIPPED TO FIT DOUBLE 2X10 BEAM ASPHALT SHINGLE OVER W.P MEMBRANE OVER 1/2" PLYWOOD OVER 2X 8 ROOF FRAMING JOIST HANGER 1X4 OVER 1X10 FASCIA BOARD 1X10 FASCIA BOARD ATTACHED TO DECK FRAMING SHED INTERIOR METAL RAILING TO MATCH EXISTING <4"VERIFY SLOPE IN FIELD STONE WALL ON CONCRETE STONE CAP ON CONCRETE WALL HOT TUB PER OWNERS DIRECTION CONTROLS FOR HOT TUB @ WALL OPENING GFRA CALCULATION ADDING 42.5 SF OF EXTERIOR 2ND LEVEL DECK. EXTERIOR DECKS DO NOT ACCOUNT UNDER GFRA REGULATIONS. ADDING 37.5 SF OF COVERED STORAGE AREA UNDER THE DECK. APPROX 13 SF OF LANDSCAPED AREA WILL BE COVERED WITH CONRETE AND BECOME PART OF THE STORAGE AREA. ADDING 64 SF OF HOT TUB PIT WITH CENTER DRAIN TO DAYLIGHT WILL SITE COVERAGE. TOTAL ADDITIONAL IMPERVIOUS: 77 SF. TOTAL EXISTING=1450 SF TOTAL ALLOWABLE = (40% X 4343)=1737.20 SF TOTAL PROPOSED= 1527 SF OF IMPERVIOUS GROUND -If building site is within a conventional zone district in unincorporated Eagle County, you can obtain allowable floor area ratio, lot coverage and impervious cover by referencing Eagle County Land Use Regulations Article 2-Definitions, Floor Area Ratio, Lot Coverage and Impervious Cover or Materials and Article 3 Zone Districts Table 3-340 Schedule of Dimensional Limitations, Maximum Lot Coverage, Impervious Materials and Maximum Floor Area Ratio. SCALE PROJECT NUMBER DATE DRAWN BY CHECKED BY As indicated A3 MAIN LEVEL FLOORPLANS & DETAILS 13.07.014289 NUGGET LN EAST VAIL, CO 81658DESIGN DEVELOPMENT05.14.2014 HDB HDB 1/4" = 1'-0" 1 EXISTING/DEMO LOWER LEVEL FLOORPLAN 1/4" = 1'-0" 2 NEW LOWER LEVEL FLOORPLAN 1/4" = 1'-0" 3 MAIN LEVEL DEMO & NEW FLOORPLAN 1/2" = 1'-0" 4 EAST ELEVATION 12" = 1'-0" 5 3D View 8_16 1 1/2" = 1'-0" 7 DECK TO ROOF DETAIL No. Description Date 1/2" = 1'-0" 8 1 - HOT TUB DRB APPROVED 7/15/2014 12:00:00 AM 36 sq. ft. of new GRFA 10/07/14