HomeMy WebLinkAboutCut sheet.pdfFor reference only. Consult Manual before installation
1 TC36.CE 310511-11
for architects&designers
Fireplace and Venting Specifications
Model TC36 & TC36 Arch Series C
IMPORTANT
This booklet is intended as a basic
specification guide for architects,
designers and builders. Please refer
to the Instruction Manual
supplied with the fireplace for
detailed information regarding
installation and operation.
Product installation manuals can
also be viewed at:
www.townandcountryfireplaces.com
TC36 & TC36 Arch
Series C
2 TC36.CE 310511-11
For reference only. Consult Manual before installation
Fireplace Dimensions
Examples of Common Locations
TC36.CE Cad Drawing
Available at
www.townandcountryfireplaces.com
48 1/425 3/4
24 1/16
37 1/2
47 13/16
32 1/8
11 11/16
37 1/2
11 11/16
47 13/16
32 3/16
37 1/2
28 1/16
11 7/16
36 1/8
24 1/16
3 TC36.CE 310511-11
For reference only. Consult Manual before installation
D
E
F
CBA
Mantel Clearance Chart
Minimum Clearances to Combustibles
UNIT MAY BE RECESSED UP TO 6" WITH NON-COMBUSTIBLE MASONRY TYPE MATERIAL
TOP OF LINTEL BAR
COMBUSTIBLE FRAMING AND FINISH WALL ABOVE STANDOFFS
MAY USE COMBUSTIBLE FACING MATERIAL IN THIS AREA
NON-COMBUSTIBLE FINISH MATERIAL
STANDOFFS
STEEL FRAMING
FIREPLACE FRONT
A 9" D 12"
B 6" E 6 3/4"
C 3" F 1 1/2"
REF. MANTLE CLEARANCE REF. MANTLE EXTENSION
NON-COMBUSTIBLE ZONE.DO NOT INSTALL ANY COMBUSTIBLE MATERIAL, ELECTRICAL WIRING, INSULATION, PLASTIC VAPOUR BARRIER OR GAS PLUMBING IN THIS AREA
Side standoffs ......................0 in. (0 mm)
Back standoffs .....................0 in. (0 mm)
Top standoffs .......................0 in. (0 mm)
Bottom of appliance .............0 in. (0 mm)
Adjacent sidewall .................4 in. (102 mm)
Ceiling to appliance ...........24 in. (610 mm)
Mantel to appliance .........................See above
Maximum mantel extension ..........See above
Mantel support .....................4 in. (102 mm)
Vertical vent pipe ...............1 3/4" (45mm)
Horizontal vent pipe
(Top, sides and bottom) ..... 1 3/4" (45mm)
*
**
4 TC36.CE 310511-11
For reference only. Consult Manual before installation
Minimum Combustible Framing Dimensions
Steel Stud Framing Kit Dimensions
Kit supplied with unit
Non-combustible board (or
other non-combustible
material) must extend 12"
above and 4 1/2" to the sides
of the framing edges.
NON-COMBUSTIBLEBOARD
All other framing
can be done with
conventional lumber
NOTE: Fireplace should be in its
final location before framing.
Non-combustible
Board Detail
Non-combustible Zone.
Do not install any
combustible material,
electric wiring,
insulation, plastic
vapour barrier or
gas plumbing
within the steel
stud frame.
50 1/4”
48”
20 13/16”
56 9/16”
29 3/8”
50 1/4”
79 15/16”
56 9/16”
50 1/4”
23 3/8”
3/4”
12 11/16”
Including Sheetrock
5 TC36.CE 310511-11
For reference only. Consult Manual before installation
Maestro Control SystemMaestro Control System
Up to 50 Feet
WINDOW
FRAME
HEARTH
EXTENSION
WINDOW
TRACK
SUB-FLOOR
Side Facing Clearances
Caution: While a hearth extension is not required and
combustible flooring materials may be brought directly up to
the fireplace, many materials (such as wood flooring) may
not tolerate the radiant heat from this fireplace, resulting in
discoloration, shrinking and cracking. For this reason, we
suggest a non-combustible hearth that is no more than 1”
above the bottom of the fireplace. If thicker, fireplace must
be raised accordingly.
Caution: Hearth extensions thicker than 1” will interfere with
the window frame when opening.
NON-COMBUSTIBLE
FINISH MATERIAL
FRAMING
EDGES
GLASS
FRAME
Hearth Extension
Caution: This fireplace may be recessed up to a maxi-
mum depth of 6". This recess must be constructed from
non combustible material. The space between the outside
framing edge and the firebox must be completely free of
any obstructions or debris and the window, with trim fit-
ted, must be able to move freely. No building material is
permitted to protrude past the framing edges attached to
the fireplace under ANY circumstance.
Town and Country C Series fireplaces include our award
winning Maestro controls.
They include an elegant, programmable remote control
with a count-down timer, weekday/weekend on/off timer,
manual control and thermostat mode (where permitted),
and an easy to read LCD display.
They also come with a small, wall-mounted control which
permits on/off operation, flame modulation and houses
the battery back-up system for operation during power
outages.
Maestro controls use an on-demand electronic ignition
system, a green alternative to standing pilots, which can
cut your annual fuel consumption up to 74%.
6 TC36.CE 310511-11
For reference only. Consult Manual before installation
Direct Vent Wall Installation Direct Vent Roof Installation
14 1/2"
FRAMED
OPENING
24" VENT
PIPE
ELBOW
12" VENT PIPE
WALL SHIELD THIMBLE
HORIZONTAL
TERMINAL
* 68 1/2"
* Minimum height from the floor to center of the opening with a
maximum horizontal run of 18" from the center of the flue outlet
to the outside face of the outer wall. The height will need to be
increased if a longer horizontal pipe is required.
7 TC36.CE 310511-11
For reference only. Consult Manual before installation
Wall Termination Venting Charts
NOTE: The vent must not exceed a total length
of 68 feet. Any combination of rise and run may
be used but must be constrained to the bounda-
ries of this chart. A total of three 90° elbows, or
combination of other elbows equalling 90° can
be used without reducing horizontal run. For each
additional 90° elbow, or an equal combination
of elbows, reduce horizontal vent run by 2 feet.
Ensure vent pipe is properly supported.
* 68 1/2”
** All dimensions are approximate. Both rise and run may vary with different
combinations of pipe.
24" Pipe
length
minimum
A
Minimum rise
B
Pipe length
C
Maximum run
D
Pipe length
Max.
68 1/2”1-24”20 1/2"1-12"
72 3/4”1-12” 1-18"75 3/4"1-48" 1-12"
78 3/4”1-24" 1-12”11' 2"2-48" 1-24"
84 3/4”1-24” 1-18"15' 10 1/2"3-48" 1-24"
1-12"
92 1/2”1-48”20’ 10 1/2”5-48"
For other rise/run combinations see chart below
**
TCVT Wall Vent
Cad Drawing
Available at
www.townandcountryfireplaces.com
8 TC36.CE 310511-11
For reference only. Consult Manual before installation
Roof Termination Venting Charts
TCVT Roof Vent Cad Drawing
Available at
www.townandcountryfireplaces.com
NOTE: The vent must not exceed a total length of
68 feet. Any combination of rise and run may be
used, but must be constrained to the boundaries of
this chart. A total of four 90° elbows or combination
of other elbows equalling 90° can be used without
reducing horizontal run. For each additional 90°
elbow, or an equal combination of elbows, reduce
horizontal vent run by 2 feet. Ensure vent pipe is
properly supported.
** All dimensions are approximate. Both rise and run may vary with different
combinations of pipe.
24" Pipe
length
minimum
A
Minimum rise
B
Pipe length
C
Maximum run
D
Pipe length
Maximum
68 1/2”1-24”29"1-12"
72 3/4”1-12” 1-18"75 1/4"1-48" 1-12"
78 3/4” 1-24" 1-12”11' 1 1/2"2-48" 1-24"
84 3/4”1-24" 1-18"15' 10"3-48" 1-24"
1-12"
92 1/2”1-48”20’ 10”5-48"
For other rise/run combinations see chart below
**
9 TC36.CE 310511-11
For reference only. Consult Manual before installation
M
K
I
AV
G
G
H
AJ
V
G
A
B
C
A
V
V
AV
B
FBL
V
E
V
V
V
D
A= *12 inches (30 cm) min. Clearances above grade, veranda, porch, deck, or balcony
B= *12 inches (30 cm) min. Clearance to window or door that may be opened
C= 12 inches (30 cm) min. Clearance to permanently closed window recommended to prevent condensation on window
D= 30 inches (76 cm) min. Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the edge of the terminal
E= 30 inches (76 cm) min. Clearance to unventilated soffit
F= 6 inches (15 cm) min. Clearance to outside corner
G= 6 inches (15 cm) min. Clearance to inside corner
H= 3 feet (90 cm) min. *Not to be installed above a meter/regulator assembly within 3 feet (90 cm) horizontally from the center-line of the regulator
I= *6 feet (1.8 m) min. Clearance to service regulator vent outlet
J= *12 inches (30 cm) min. Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance
K= *6 feet (1.8 m) min. Clearance to a mechanical air supply inlet
L= *7 feet (2.1 m) min. ^ Clearance above paved side-walk or a paved driveway located on public property
M= **30 inches (76 cm) min Clearance under veranda, porch, deck, or balcony
^ a vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*
** only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor*
* as specified in CAN/CSA B149 Installation Codes, Note: local Codes or Regulation may require different clearances
* for U.S.A. Installations follow the current National Fuel Gas Code, NFPA54 /ANSI #Z21.50.b
AIR SUPPLY INLETVENT TERMINAL GAS METER
FIXEDCLOSED
FIXEDCLOSED OPEN-ABLEOPEN- ABLE
AREA WHERE TERMINAL
IS NOT PERMITTED
Vent Terminal Minimum Clearances
36"
See Fig. #40b
48"
ADJACENT
24"
(91.5 cm)(61 cm)
(122 cm)
STRUCTURESOR FENCE
Minimum clearances to the vent terminal must be maintained as
shown (See illustration to right & below). Measure clearances to the
nearest edge of termination hood. (See pitch table below).
NOTE: Vent terminal must not be recessed
NOTE: LOCAL CODES OR REGULATIONS MAY REQUIRE
DIFFERENT CLEARANCES.
Roof Pitch Table (minimum)
ft m
Flat to 6/12 1.00 0.30
Over 6/12 to 7/12 1.25 0.38
Over 7/12 to 8/12 1.50 0.46
Over 8/12 to 9/12 2.00 0.61
Over 9/12 to 10/12 2.50 0.76
Over 10/12 to 11/12 3.25 0.99
Over 11/12 to 12/12 4.00 1.22
VENT TERMINAL MINIMUM CLEARANCES
TO ADJACENT STRUCTURES
Vent Terminal Clearance
See Roof Pitch Table
10 TC36.CE 310511-11
Optional Power Vent
Power Vent Terminals
Reach almost any room or commercial setting.
Optional Power Venting allows runs up to 110’ from
an outside wall or roof surface. Vent horizontally or
vertically with up to six 90-degree elbows, including
runs up to 3’ below the fireplace.
The premium Power Vent fan runs quietly outside,
at the exterior terminal.
Direct Vent Terminals
Cad Drawings available at www.townandcountryfireplaces.com
Cad Drawings available at www.townandcountryfireplaces.com
Wall Termination Roof Termination Flush Mount
Horizontal Termination
Standard Venting Standard Venting Stainless Steel Standard Venting
Roof Termination Wall Termination Termination for Condo Installation