HomeMy WebLinkAboutCut sheet.pdfFor reference only. Consult Manual before installation 1 TC36.CE 310511-11 for architects&designers Fireplace and Venting Specifications Model TC36 & TC36 Arch Series C IMPORTANT This booklet is intended as a basic specification guide for architects, designers and builders. Please refer to the Instruction Manual supplied with the fireplace for detailed information regarding installation and operation. Product installation manuals can also be viewed at: www.townandcountryfireplaces.com TC36 & TC36 Arch Series C 2 TC36.CE 310511-11 For reference only. Consult Manual before installation Fireplace Dimensions Examples of Common Locations TC36.CE Cad Drawing Available at www.townandcountryfireplaces.com 48 1/425 3/4 24 1/16 37 1/2 47 13/16 32 1/8 11 11/16 37 1/2 11 11/16 47 13/16 32 3/16 37 1/2 28 1/16 11 7/16 36 1/8 24 1/16 3 TC36.CE 310511-11 For reference only. Consult Manual before installation D E F CBA Mantel Clearance Chart Minimum Clearances to Combustibles UNIT MAY BE RECESSED UP TO 6" WITH NON-COMBUSTIBLE MASONRY TYPE MATERIAL TOP OF LINTEL BAR COMBUSTIBLE FRAMING AND FINISH WALL ABOVE STANDOFFS MAY USE COMBUSTIBLE FACING MATERIAL IN THIS AREA NON-COMBUSTIBLE FINISH MATERIAL STANDOFFS STEEL FRAMING FIREPLACE FRONT A 9" D 12" B 6" E 6 3/4" C 3" F 1 1/2" REF. MANTLE CLEARANCE REF. MANTLE EXTENSION NON-COMBUSTIBLE ZONE.DO NOT INSTALL ANY COMBUSTIBLE MATERIAL, ELECTRICAL WIRING, INSULATION, PLASTIC VAPOUR BARRIER OR GAS PLUMBING IN THIS AREA Side standoffs ......................0 in. (0 mm) Back standoffs .....................0 in. (0 mm) Top standoffs .......................0 in. (0 mm) Bottom of appliance .............0 in. (0 mm) Adjacent sidewall .................4 in. (102 mm) Ceiling to appliance ...........24 in. (610 mm) Mantel to appliance .........................See above Maximum mantel extension ..........See above Mantel support .....................4 in. (102 mm) Vertical vent pipe ...............1 3/4" (45mm) Horizontal vent pipe (Top, sides and bottom) ..... 1 3/4" (45mm) * ** 4 TC36.CE 310511-11 For reference only. Consult Manual before installation Minimum Combustible Framing Dimensions Steel Stud Framing Kit Dimensions Kit supplied with unit Non-combustible board (or other non-combustible material) must extend 12" above and 4 1/2" to the sides of the framing edges. NON-COMBUSTIBLEBOARD All other framing can be done with conventional lumber NOTE: Fireplace should be in its final location before framing. Non-combustible Board Detail Non-combustible Zone. Do not install any combustible material, electric wiring, insulation, plastic vapour barrier or gas plumbing within the steel stud frame. 50 1/4” 48” 20 13/16” 56 9/16” 29 3/8” 50 1/4” 79 15/16” 56 9/16” 50 1/4” 23 3/8” 3/4” 12 11/16” Including Sheetrock 5 TC36.CE 310511-11 For reference only. Consult Manual before installation Maestro Control SystemMaestro Control System Up to 50 Feet WINDOW FRAME HEARTH EXTENSION WINDOW TRACK SUB-FLOOR Side Facing Clearances Caution: While a hearth extension is not required and combustible flooring materials may be brought directly up to the fireplace, many materials (such as wood flooring) may not tolerate the radiant heat from this fireplace, resulting in discoloration, shrinking and cracking. For this reason, we suggest a non-combustible hearth that is no more than 1” above the bottom of the fireplace. If thicker, fireplace must be raised accordingly. Caution: Hearth extensions thicker than 1” will interfere with the window frame when opening. NON-COMBUSTIBLE FINISH MATERIAL FRAMING EDGES GLASS FRAME Hearth Extension Caution: This fireplace may be recessed up to a maxi- mum depth of 6". This recess must be constructed from non combustible material. The space between the outside framing edge and the firebox must be completely free of any obstructions or debris and the window, with trim fit- ted, must be able to move freely. No building material is permitted to protrude past the framing edges attached to the fireplace under ANY circumstance. Town and Country C Series fireplaces include our award winning Maestro controls. They include an elegant, programmable remote control with a count-down timer, weekday/weekend on/off timer, manual control and thermostat mode (where permitted), and an easy to read LCD display. They also come with a small, wall-mounted control which permits on/off operation, flame modulation and houses the battery back-up system for operation during power outages. Maestro controls use an on-demand electronic ignition system, a green alternative to standing pilots, which can cut your annual fuel consumption up to 74%. 6 TC36.CE 310511-11 For reference only. Consult Manual before installation Direct Vent Wall Installation Direct Vent Roof Installation 14 1/2" FRAMED OPENING 24" VENT PIPE ELBOW 12" VENT PIPE WALL SHIELD THIMBLE HORIZONTAL TERMINAL * 68 1/2" * Minimum height from the floor to center of the opening with a maximum horizontal run of 18" from the center of the flue outlet to the outside face of the outer wall. The height will need to be increased if a longer horizontal pipe is required. 7 TC36.CE 310511-11 For reference only. Consult Manual before installation Wall Termination Venting Charts NOTE: The vent must not exceed a total length of 68 feet. Any combination of rise and run may be used but must be constrained to the bounda- ries of this chart. A total of three 90° elbows, or combination of other elbows equalling 90° can be used without reducing horizontal run. For each additional 90° elbow, or an equal combination of elbows, reduce horizontal vent run by 2 feet. Ensure vent pipe is properly supported. * 68 1/2” ** All dimensions are approximate. Both rise and run may vary with different combinations of pipe. 24" Pipe length minimum A Minimum rise B Pipe length C Maximum run D Pipe length Max. 68 1/2”1-24”20 1/2"1-12" 72 3/4”1-12” 1-18"75 3/4"1-48" 1-12" 78 3/4”1-24" 1-12”11' 2"2-48" 1-24" 84 3/4”1-24” 1-18"15' 10 1/2"3-48" 1-24" 1-12" 92 1/2”1-48”20’ 10 1/2”5-48" For other rise/run combinations see chart below ** TCVT Wall Vent Cad Drawing Available at www.townandcountryfireplaces.com 8 TC36.CE 310511-11 For reference only. Consult Manual before installation Roof Termination Venting Charts TCVT Roof Vent Cad Drawing Available at www.townandcountryfireplaces.com NOTE: The vent must not exceed a total length of 68 feet. Any combination of rise and run may be used, but must be constrained to the boundaries of this chart. A total of four 90° elbows or combination of other elbows equalling 90° can be used without reducing horizontal run. For each additional 90° elbow, or an equal combination of elbows, reduce horizontal vent run by 2 feet. Ensure vent pipe is properly supported. ** All dimensions are approximate. Both rise and run may vary with different combinations of pipe. 24" Pipe length minimum A Minimum rise B Pipe length C Maximum run D Pipe length Maximum 68 1/2”1-24”29"1-12" 72 3/4”1-12” 1-18"75 1/4"1-48" 1-12" 78 3/4” 1-24" 1-12”11' 1 1/2"2-48" 1-24" 84 3/4”1-24" 1-18"15' 10"3-48" 1-24" 1-12" 92 1/2”1-48”20’ 10”5-48" For other rise/run combinations see chart below ** 9 TC36.CE 310511-11 For reference only. Consult Manual before installation M K I AV G G H AJ V G A B C A V V AV B FBL V E V V V D A= *12 inches (30 cm) min. Clearances above grade, veranda, porch, deck, or balcony B= *12 inches (30 cm) min. Clearance to window or door that may be opened C= 12 inches (30 cm) min. Clearance to permanently closed window recommended to prevent condensation on window D= 30 inches (76 cm) min. Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the edge of the terminal E= 30 inches (76 cm) min. Clearance to unventilated soffit F= 6 inches (15 cm) min. Clearance to outside corner G= 6 inches (15 cm) min. Clearance to inside corner H= 3 feet (90 cm) min. *Not to be installed above a meter/regulator assembly within 3 feet (90 cm) horizontally from the center-line of the regulator I= *6 feet (1.8 m) min. Clearance to service regulator vent outlet J= *12 inches (30 cm) min. Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance K= *6 feet (1.8 m) min. Clearance to a mechanical air supply inlet L= *7 feet (2.1 m) min. ^ Clearance above paved side-walk or a paved driveway located on public property M= **30 inches (76 cm) min Clearance under veranda, porch, deck, or balcony ^ a vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* ** only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 Installation Codes, Note: local Codes or Regulation may require different clearances * for U.S.A. Installations follow the current National Fuel Gas Code, NFPA54 /ANSI #Z21.50.b AIR SUPPLY INLETVENT TERMINAL GAS METER FIXEDCLOSED FIXEDCLOSED OPEN-ABLEOPEN- ABLE AREA WHERE TERMINAL IS NOT PERMITTED Vent Terminal Minimum Clearances 36" See Fig. #40b 48" ADJACENT 24" (91.5 cm)(61 cm) (122 cm) STRUCTURESOR FENCE Minimum clearances to the vent terminal must be maintained as shown (See illustration to right & below). Measure clearances to the nearest edge of termination hood. (See pitch table below). NOTE: Vent terminal must not be recessed NOTE: LOCAL CODES OR REGULATIONS MAY REQUIRE DIFFERENT CLEARANCES. Roof Pitch Table (minimum) ft m Flat to 6/12 1.00 0.30 Over 6/12 to 7/12 1.25 0.38 Over 7/12 to 8/12 1.50 0.46 Over 8/12 to 9/12 2.00 0.61 Over 9/12 to 10/12 2.50 0.76 Over 10/12 to 11/12 3.25 0.99 Over 11/12 to 12/12 4.00 1.22 VENT TERMINAL MINIMUM CLEARANCES TO ADJACENT STRUCTURES Vent Terminal Clearance See Roof Pitch Table 10 TC36.CE 310511-11 Optional Power Vent Power Vent Terminals Reach almost any room or commercial setting. Optional Power Venting allows runs up to 110’ from an outside wall or roof surface. Vent horizontally or vertically with up to six 90-degree elbows, including runs up to 3’ below the fireplace. The premium Power Vent fan runs quietly outside, at the exterior terminal. Direct Vent Terminals Cad Drawings available at www.townandcountryfireplaces.com Cad Drawings available at www.townandcountryfireplaces.com Wall Termination Roof Termination Flush Mount Horizontal Termination Standard Venting Standard Venting Stainless Steel Standard Venting Roof Termination Wall Termination Termination for Condo Installation Printed in Canada For personal service pertaining to specific projects, contact: Town & Country Architect Resource Planner architects@pacificenergy.net Web: www.townandcountryfireplaces.com Phone: (250) 748-1184 Toll Free: 1-877-715-2664 2975 Allenby Road, Duncan, BC Canada V9L 6V8