HomeMy WebLinkAboutBegin_Workflow - Review Comments - 08-19-2014_09-49-59.pdfBegin_Workflow Review Comments 08192014_094959
Review
Cycle Department Markup Snapshot
2 Building File: Roof Plan with dimensions.pdf
ChangeMark: mhaeberle
Description: B001
Comment: Show connection method in conformance with Vail snow loads per the IBC 2012 edition. Architect to identify practicing structural engineering in that
the purpose of the roof plan is not only to identify location of the panels but to clarify structural integrity of the roof and the electrical system being installed on the
roof.
2 Building File: Roof Plan with dimensions.pdf
ChangeMark: mhaeberle
Description: B002
Comment: Indicate on plans building code edition of the structural design
2 Fire File: Roof Plan with dimensions.pdf
ChangeMark: fire comments
Description: FD0001
Comment: IFC section 605.11.3.2.4 Panels/modules installed on residential buildings shall be located no higher than three feet below the ridge in order to allow
for fire department smoke ventilation operations. show clearances/dimensions