Loading...
HomeMy WebLinkAboutBegin_Workflow - Review Comments - 08-19-2014_09-49-59.pdfBegin_Workflow ­ Review Comments ­ 08­19­2014_09­49­59 Review Cycle Department Markup Snapshot 2 Building File: Roof Plan with dimensions.pdf ChangeMark: mhaeberle Description: B001 Comment: Show connection method in conformance with Vail snow loads per the IBC 2012 edition. Architect to identify practicing structural engineering in that the purpose of the roof plan is not only to identify location of the panels but to clarify structural integrity of the roof and the electrical system being installed on the roof. 2 Building File: Roof Plan with dimensions.pdf ChangeMark: mhaeberle Description: B002 Comment: Indicate on plans building code edition of the structural design 2 Fire File: Roof Plan with dimensions.pdf ChangeMark: fire comments Description: FD­0001 Comment: IFC section 605.11.3.2.4 ­ Panels/modules installed on residential buildings shall be located no higher than three feet below the ridge in order to allow for fire department smoke ventilation operations. show clearances/dimensions