Loading...
HomeMy WebLinkAboutMastiff080514 Aero Report.pdf780 Simms Street Suite 104 Golden, CO, 80401 303.232.3746 Certificate of Analysis www.aerobiology.net Client Name ECOS Environmental Date Collected:08/05/14 Street address 6690 Hwy 82 Date Received:08/06/14 City, State ZIP Glenwood Springs, CO 81601 Date Analyzed:08/06/14 Attn: Josh Johnson 200860-0 Date Reported:08/06/14 Client Project Name: Mastiff 080514 Project ID:14016283 Job ID: Test Requested:3002, Asbestos in Bulk Samples Method:Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Non-Asbestos Non-Fibrous Matrix Fiber Material Material Client Percentage Percentage Composition P = Perlite B = Binder D=Diatoms NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC 780 Simms Street, Suite 104, Golden, CO, 80401, 303.232.3746 327 A1 327 A2 327 A3 327 B1 N N 15% 85% 10% N N Trace=Less Than 1% N N 20% 5% 95% ND=None Detected CHRY=Chrysotile M = Mica CR = Crocidolite T = Tar TR = Tremolite A = Amosite Q = Quartz AC = Actinolite C = Carbonates AN = Anthophyllite G = Gypsum C ND 100 ND 10 90 G Trace 100 C ND 10 90 G ND Trace 100 C ND ND Trace 100 G ND Trace 100 C ND 1 10 90 ND Trace 100 C Asbestos Percentage White Tape ND 99N2% 4% Asbestos Detected White Texture w/Tan Paint Laboratory Analyst Ron Weyand Asbestos Laboratory Supervisor Paul Knappe Yellow/White/Black/Tan Wallpaper White Texture Tan/White Drywall 14016283-4B 14016283-3B 14016283-4A Tan/White Drywall14016283-2B White Texture w/Cream Paint14016283-3A NVLAP Lab Code 14016283-1D 14016283-2A 9% N 85% 14016283-1C N Lab Sample Number N Tan/White Drywall White Texture w/Cream Paint White Joint Compound Sample Identification Physical Description of Sample/Layer Homo- geneous (Y/N) Layer Percentage 14016283-1A 14016283-1B Page 1 of 4 780 Simms Street Suite 104 Golden, CO, 80401 303.232.3746 Certificate of Analysis www.aerobiology.net Client Name ECOS Environmental Date Collected:08/05/14 Street address 6690 Hwy 82 Date Received:08/06/14 City, State ZIP Glenwood Springs, CO 81601 Date Analyzed:08/06/14 Attn: Josh Johnson 200860-0 Date Reported:08/06/14 Client Project Name: Mastiff 080514 Project ID:14016283 Job ID:0 Test Requested:3002, Asbestos in Bulk Samples Method:Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Non-Asbestos Non-Fibrous Matrix Fiber Material Material Client Percentage Percentage Composition P = Perlite B = Binder D=Diatoms NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC 780 Simms Street, Suite 104, Golden, CO, 80401 NVLAP Lab Code Sample Identification Physical Description of Sample/Layer Homo- geneous (Y/N) Layer Percentage Asbestos Detected Asbestos Percentage Lab Sample Number 327 B1 14016283-4C Tan Drywall N 70%ND 10 90 G 14016283-5A White Tape N 5%ND 99 1 327 B2 C 14016283-5C White Texture w/Gray-White Wallpaper N 20%ND Trace 100 C 14016283-5B White Joint Compound N 10%ND Trace 100 G 14016283-6A White Tape N 2%ND 99 1 14016283-5D Tan/White Drywall N 65%ND 10 90 327 B3 A = Amosite C 14016283-6C White Joint Compound N 13%ND Trace 100 C 14016283-6B White Texture w/Gray-White Wallpaper N 5%ND Trace 100 10 90 G 327 C1 14016283-7A White Tape N 2%ND 14016283-6D Tan/White Drywall N 80%ND AC = Actinolite C = Carbonates AN = Anthophyllite G = Gypsum CHRY=Chrysotile M = Mica 99 1 Q = Quartz Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected CR = Crocidolite T = Tar TR = Tremolite Paul Knappe Ron Weyand Trace=Less Than 1% Page 2 of 4 780 Simms Street Suite 104 Golden, CO, 80401 303.232.3746 Certificate of Analysis www.aerobiology.net Client Name ECOS Environmental Date Collected:08/05/14 Street address 6690 Hwy 82 Date Received:08/06/14 City, State ZIP Glenwood Springs, CO 81601 Date Analyzed:08/06/14 Attn: Josh Johnson 200860-0 Date Reported:08/06/14 Client Project Name: Mastiff 080514 Project ID:14016283 Job ID:0 Test Requested:3002, Asbestos in Bulk Samples Method:Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Non-Asbestos Non-Fibrous Matrix Fiber Material Material Client Percentage Percentage Composition P = Perlite B = Binder D=Diatoms NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC 780 Simms Street, Suite 104, Golden, CO, 80401 Laboratory Analyst Asbestos Laboratory Supervisor ND=None Detected CR = Crocidolite T = Tar TR = Tremolite Paul Knappe Ron Weyand Trace=Less Than 1% AC = Actinolite C = Carbonates AN = Anthophyllite G = Gypsum CHRY=Chrysotile M = Mica Q = Quartz G14016283-9D Tan/White Drywall N 65%ND 327 C3 A = Amosite C 14016283-9C White Joint Compound N 20%ND Trace 100 C 14016283-9B White Texture w/Cream Paint N 12%ND Trace 100 10 90 G 14016283-9A White Tape N 3%ND 99 1 14016283-8B Tan/White Drywall N 85%ND 10 90 327 C2 G 14016283-8A White Texture w/Cream Paint N 15%ND Trace 100 C 14016283-7D Tan/White Drywall N 85%ND 10 90 327 C1 Trace 100 C 14016283-7C White Joint Compound N 9%ND Trace 100 C NVLAP Lab Code Sample Identification Physical Description of Sample/Layer Homo- geneous (Y/N) Layer Percentage Asbestos Detected Asbestos Percentage Lab Sample Number 14016283-7B White Texture w/Cream Paint N 4%ND Page 3 of 4 780 Simms Street Suite 104 Golden, CO, 80401 303.232.3746 Certificate of Analysis www.aerobiology.net ECOS Environmental Date Collected:08/05/14 6690 Hwy 82 Date Received:08/06/14 Glenwood Springs, CO 81601 Date Analyzed:08/06/14 Josh Johnson 200860-0 Date Reported:08/06/14 Client Project Name: Mastiff 080514 Project ID:14016283 Job ID: General Notes  ND indicates no asbestos was detected; the method detection limit is 1 %.  Trace or "<1" indicates asbestos was identified in the sample, but the concentration is less than 1%. Notes Required by NVLAP  This test report relates only to the items tested or calibrated.  This report is not valid unless it bears the name of a NVLAP-approved signatory.  Any reproduction of this document must include the entire document in order for the report to be valid. 780 Simms Street, Suite 104, Golden, CO, 80401, 303.232.3746 NVLAP Lab Code  This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.  All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunerite. Crocidolite is the common name used for the asbestiform variety of the mineral riebeckite.  Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM floor tile analysis is accepted under NESHAP regulations.        These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.’s current terms and conditions of sale, including the company’s standard warranty and limitation  of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted.  Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days before discarding. A shipping and handling charge will be assessed for the return of any samples.  Aerobiology does not guarantee the results of tape lifts, microvacs, wipe, and/or debris samples. Accurate analysis cannot be performed due to particle size, media used, and/or amount of material given. Analysis of these materials should be preformed by a TEM. A result of ND does not indicate that the sample area does not contain asbestos. It means the analyst could not identify asbestos in the specific sample for the reasons listed above. Page 4 of 4