Loading...
HomeMy WebLinkAboutMastiff080514 negative asbestos report.pdfEcos Environmental Job #3G060214 Page 1 Date: 08-08-2014 Asbestos Sampling Report To: Jose Cornide Regarding: 357 West Rockledge Rd. Vail, CO Mr. Cornide, On 08-05-2014, ECOS Environmental & Disaster Restoration Inc. conducted a limited asbestos inspection of VISIBLE suspect ACM (asbestos containing materials) for a home remodel. If other suspect materials become visible/apparent during demolition or construction, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. A limited bulk sampling of suspect ACM was conducted in accordance with Colorado State Requirements. Said requirements state for surfacing materials: each homogenous area of less than 1000 SF, a minimum of three samples must be collected randomly. For each homogenous area of 1000-5000 SF, a minimum of five samples must be collected. For areas larger than 5001 SF a minimum of seven samples must be collected, respectively. For miscellaneous materials at least one sample must be taken. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. Joshua Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401, performed the inspection. Samples taken were sent to Aerobiology Laboratory, for PLM (Polarized Light Microscopy) analysis. DESCRIPTION OF SAMPLING AREA There is a proposed remodel for all of the bathrooms, the kitchen, and the garage. Ecos Environmental Job #3G060214 Page 2 SUSPECT MATERIALS SAMPLED Tape, Texture, Drywall, and Joint Compound CONCLUSIONS No Asbestos was detected. Joshua Johnson Asbestos Manager Ecos Environmental (970) 274-3139