Loading...
HomeMy WebLinkAboutAsbestos Report.pdf State of Colorado Asbestos Testing & Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testing required? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two-Family Dwellings: 32 square feet All Others (commercial spaces, hotel rooms, etc): 160 square feet Definition of a single-family dwelling: any dwelling unit that is used primarily for a single family, including multi-family/condominium units, and fractional fee units. Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State-certified abatement contractor. The air clearance letter or form must be submitted to the Town of Vail before the building permit will be issued. Project Checklist Will not disturb more than the threshold limits identified above. Tested negative, or at 1% or below (1 copies of test results included) Tested positive at more than 1%, requires abatement (1 copies of test results included) My project falls into the category checked below: Tips & Facts: Even recent construction projects may include asbestos-containing materials, so buildings of any age require testing.  The "1989 Ban" on asbestos-containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so-called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos-containing product categories was set aside and did not take effect." - CDPHE Asbestos test results should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: State of Colorado Contact: Fire Prevention Bureau Colorado Department of Public Health Vail Fire Department and Environment 75 S Frontage Rd Asbestos Compliance Assistance Group Fire_inspectors@vailgov.com 303-692-3158 970-479-2252 asbestos@state.co.us www.vailgov.com www.cdphe.state.co.us 01-Jan-11 A &D Asbestos Testing and Consulting John R.Peterman *********** P.O.Box 1230 Clifton,CO.81520-1230 Ce11970-270-3689 Home Phone 970-464-5265 INSPECTION REPORT PREPARED FOR: George Shaeffer Construction P.O.Box 373 Vail,CO.81658 LOCATION: Residence 146 Forest Rd. Vail,CO. REPORT PREPARED BY: John R.Peterman Inspector Manager COLORADO Cert.jicate No.6601 COLORADO Registration #ACF-16522 2 A &D Asbestos Testing and Consulting John R.Peterman Asbestos Testing,Project Design,and Consulting INTRODUCTION: On Aug.2,2013 an inspection/survey was conducted and 5 bulk samples were collected from: Residence 146 Forest Rd. Vail,CO. The purpose of the inspection/survey was to locate and sample suspected Asbestos containing materials that might be present in the area of the Residence that is planned for selective interior renovation. The inspection was made,and the samples were collected by John R. Peterman,an A.H.E.R.A.and State of Colorado Certified Asbestos Inspector.Great care was taken during the inspection and sampling to be as accurate as possible.It should be noted that minimal damage was done to the existing building structures during the inspection so there is no documentation for unseen conditions or stored items. All samples were analyzed by DCM Science Lab in Wheat Ridge,CO. This laboratory is deemed "Proficient"in the E.P.A.Quality Assurance (QA) program for the determination of asbestos in bulk materials,and is accredited by the American Hygiene Association (AHA). Sl~MPLlNGPROTOCOL: A random sampling scheme was used to sample the suspect materials that were discovered. 3 A &D Asbestos Testing and Consulting John R.Peterman Asbestos Testing,Prcject Design,and Consulting Residence 146 Forest Rd. Vail,CO. RENOVATION AREA DESCRIPTION: The area of the residence that is planned for renovation are located in several areas.The exterior walls are covered with wood siding.The interior walls are covered in sheetrock with a light texture.The ceiling is covered with sheetrock like the walls.The floor is covered in wood,stone and carpet. CONCLUSIONS &RECOMMENDATIONS: Laboratory analysis,of the bulk samples,indicates that no Asbestos was detected in any of the samples. 4 T Date:8/612013 1I < 'location:Res~e~146ForestRd.Vail,Co. SAMPLE LOCATIONS 1 ~ 1 SAMPLE NUMBER AREA SAMPLEREMOVEDFROM 'DESCRIPTION I FRIABLE 14&-8 001 ti ~torage Under Stairs Wall j ,Composite Sheetrock WI Texture l NO 146-8 ,002 SwdyWali CompositeSbeetrockWi Texture 1 I NO 146-8 003 I.Gues.t Bedroom #1 -Composite Sheetrock WI Texture -;--:NO 146-8 '094.J Guest Master Bathroom Wall Composite Shee~'!'IlTexture ~+NO 146-8 005!Guest Master Bedroom 'Wall Co~poslt8 Sheetrock WI Texture L ~NO ,Date: ~.. location: + j. 81612013 j.-T , ! -+- ..., Residence 146 Forest Rd.Vall,Co. t -r NUMBER 146-B 001 146-8 002 146-B 00.3 146-8 004 '146-B 005--r-- ISAMPLE.RESUt TS DESCRIPTION ,Composite Sheeb:ock '!IITexture ,~mposlte Sheetrock WI Texture 1 Composite Sheetrock WI Texture I Composite Sheetrock WI Texture Composite Sheetrock W!Texture 'NAO INo Asbestos Detected KEY: ASBESTOS TYPE , NAD NAD NAD NAD NAD % 0..00 0.00 0.00 0.00 0.00 -i Date: location: SAMPLE 146-8 146-8 146-8 146-8 146-8 KEY: 81612013' Residence 146 Forest Rd.Vail,Co. SUSPECT MATERIAL CONDITION NUMBER ITYPE OF SUS-PECT MATERIAL 001 t :.SUR 002 SUR 003 I SUR004~SUR005+-SUR SUR -Surfacing + ..j..__.J-~ 'OVERAll CONDITION DAMAGED I %r TYPE-OF DAMAGE GOOD ~:NO 0 NlA GOOD NO 0 NlA GOOD t NO 0 NJA~--GOOD ~J NO 0 NlA GOOD NO 0 ,NlA +----....... + Date:81612013 I Location:rResidence 146 Forestl'Rd~"Vail,Co. I .IPOT.DIST. Sample Number Accesslb:ility Potential yesl,!o contad 1~ 146-8 146-8 146-8 146-8 001 YES 002 YES 003 YES 004 YES 005 '¥ES-.- HIGH HIGH HIGH HIGH HIGH +Influence Potential Plenumr-vibration air erosion yes/no- .-lOW I LOW NO LOW t t lOW NO LOW I ,LOW NO+lOW I-lOW NOttOWILOWNOLL.. Date:8I6flO13 location:1Residence 146 Forest Rd.Vall.Co. SAMPLE NUMBER TYPE OF SUSPECT MATERIAL OVERALL CONDITION i DAMAGED %lYPE OF DAMAGE I 146-8 001 SUR I GOOD I-NO 0 PHYSJOET 146-8 SUR ~t-GOOD t NO 0 PHYSIDET002~t ,-146-8 003 SUR I ,GOOD NO 0 PHYSIDETI 146-8 004 SUR ..1-GOOD NO 0 PHYSIDETII.~~I146-8 005 SUR I GOOD 1 NO 0 PHYSIDETI ~ t-KEY: SUR -SwfacIng ~~ CLIENT: DRAFT ~R.l9.NM'1C..~-WIOOAl'OOY.,"" l242:1 W.4!ITH AVBNUB,UNIT M6 WHl!AT RIDGE,CO 80033 (303)<163-1270 BULK ASBESTOS TEST REPORT PAGE IOF3 A&D ASBESTOS TESTING AND CONSULTING P.O.BOX 1230 CLIFTON,CO 81520-1230 ANALYSIS DATE: REPORTING DATE: RECEIPT DAlE: CLIENT JOB NO.: PROJECT TInE:DCMSLPROJECT: PERCENTAGE COMPOSlTIONBY VISUAL ESTlMA TE DCMSL CLIENT S~LE S~LE NUMBER NUMBER -iR 146-B"()()I S~LE PERCENT DATE DESORIPTION OF SAMPLE 1I-2-J3 A.WHITE PAINT 3.0% B.TAN FIBROUS 5.0010 C.WHITE TEXTURE 10.0010 D.WHITE DRYWALL 82.0010 8-2-13 A.WHITE TEXTURE 2.0010 B.GREEN WALLPAPER 4.0010 C.TAN FIBROUS 5.0010 D.WHITEDRYWALL 89.0010 8-2-13 A.TANPAINT 2.0"10 B.TAN FIBROUS 4.0"10 C.WHITE TEXTURE 12.0010 D.WHITE DRYWALL 82.0010 8-2-13 A.WHITE TEXTURE 2.0% B.TAN FIBROUS 3.0010 C.MULTICOLORED WALLPAPER S.OO!O- D.WHITEDRYWALL 90.0% ASBESTOS TYPE -2R 146-8-002 -3R 146-8-003 -4R I46-B-004 8-5-13 8-5-13 8-5-13 RESIDENCE 146 FOREST ROAD -VAIL,CO ADAT808 TOTAL ASBESTOS RANGE %IN SAMPLE NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO TOTAL PERCENTAGE OTHER FIBROUS NON-FIBROUS IDENTIFIED CONSTITUENTS CONSTITUENTS MA TERlALS NO NO NO NO 0.0 100.0 100.0 100.0 0.0 100.0 0.0 100.0 100.0 TR 100,0 100.0 0.0 100.0 100.0 90.0 10.0 100.0 100.0 0.0 ,100.0 TR 100.0 100.0 0.0 100.0 100.0 100.0 0.0 100.0 0.0 100.0 100.0 TR 100.0 100.0 0.0 100.0 100.0 100.0 0.0 100.0 90.0 10.0 100.0 TR 100.0 100.0 DRAFT ~R19N¥._DC. 12421 W.49TH AVENIJIl,UNrU6 WHEAT RIDGE,00 10033 (303)463-827D BULK ASBESTOS TEST REPORT PAGE20F 3 CLIENT:ANAL YSI8 DATE: REPORTING DATE: RECEIPT DATE: CLIENT ros NO.: PROJECT TITLE: OCMSL PROJECT: 8-5-13 8-5-13 8-5-1.3 RESIBENCE l46 FOREST ROAD -VAIL,CO ADAT808 A&D ASBESTOS TESTING AND CONSULTING P.O.BOX 1230 CLIFTON,CO 81520-1230 PERCENTAGE COMPOSITION BY VISUAL ESTIMATE DCMSL CLIENT SAMPLE SAMPLE NUMBER NUMBER TOTAlL TOTAL PERCENTAGE PERCENT ASBEST0S ASBESTOS OTIffiR FffiROUS NON-FIBROUS IDENTIFIED OF SAMPLE TYPE RANGE %IN SAMPLE CONSTITUENTS CONSTITUENTS MATERJA'LS 2.0%NO 0.0 100.0 100.0 5.0%NO 100.0 0.0 1001.0 7.0%NO 0.0 1000 100.0 86.0%ND TR 100.0 100.0 NO SAMPLE DATE DESCRIPTION -SR 1·46·B..()05 A.WfUTE PAINT B.TANFIBROUS C.WHITE TEXTURE D.WFDTE DRYWALL 8-2·13 FOR CALCULATION PURPOSES,TRACE (TR)IS ASSUMED TO BE'O.5%. (1)-INSEPARABLE LAYERS ND •NONE DETECTED THE SAMPLES WERE RECEIVED IN ACCEPT ABLE CONDITION.THIS TEST REPORT RELATES ONL Y TO TIlE ITEMS TESTED.THIS REPORT MAYNOr BE REPRODUCED EXCEPT IN FULL, WffHOUT THE WRITTEN APPROVAL OF THE LABORATORY.