HomeMy WebLinkAboutAsbestos Report.pdf
State of Colorado
Asbestos Testing & Abatement Requirements
Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex-
posure to harmful asbestos. It is your responsibility to be in compliance with the State. Please contact the State directly
for their requirements at the contact info listed below.
When is asbestos testing required?
ANY building projects disturbing more than these threshold levels of building materials require asbestos testing:
One- and Two-Family Dwellings: 32 square feet
All Others (commercial spaces, hotel rooms, etc): 160 square feet
Definition of a single-family dwelling: any dwelling unit that is used primarily for a single family, including
multi-family/condominium units, and fractional fee units.
Asbestos testing results must be provided with your application for a building permit.
Tests which identify POSITIVE results at more than 1% require abatement by a State-certified abatement contractor. The
air clearance letter or form must be submitted to the Town of Vail before the building permit will be issued.
Project Checklist
Will not disturb more than the threshold limits identified above.
Tested negative, or at 1% or below (1 copies of test results included)
Tested positive at more than 1%, requires abatement (1 copies of test results included)
My project falls into the category checked below:
Tips & Facts:
Even recent construction projects may include asbestos-containing materials, so buildings of any age require testing.
The "1989 Ban" on asbestos-containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit
Court of Appeals vacated much of the so-called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus,
much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce
of many asbestos-containing product categories was set aside and did not take effect." - CDPHE
Asbestos test results should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657.
Town of Vail Contact: State of Colorado Contact:
Fire Prevention Bureau Colorado Department of Public Health
Vail Fire Department and Environment
75 S Frontage Rd Asbestos Compliance Assistance Group
Fire_inspectors@vailgov.com 303-692-3158
970-479-2252 asbestos@state.co.us
www.vailgov.com www.cdphe.state.co.us
01-Jan-11
A &D Asbestos Testing and Consulting
John R.Peterman
***********
P.O.Box 1230 Clifton,CO.81520-1230
Ce11970-270-3689 Home Phone 970-464-5265
INSPECTION REPORT PREPARED FOR:
George Shaeffer Construction
P.O.Box 373
Vail,CO.81658
LOCATION:
Residence
146 Forest Rd.
Vail,CO.
REPORT PREPARED BY:
John R.Peterman
Inspector Manager
COLORADO Cert.jicate No.6601
COLORADO Registration #ACF-16522
2
A &D Asbestos Testing and Consulting
John R.Peterman
Asbestos Testing,Project Design,and Consulting
INTRODUCTION:
On Aug.2,2013 an inspection/survey was conducted and 5 bulk
samples were collected from:
Residence
146 Forest Rd.
Vail,CO.
The purpose of the inspection/survey was to locate and sample
suspected Asbestos containing materials that might be present in the area of
the Residence that is planned for selective interior renovation.
The inspection was made,and the samples were collected by John R.
Peterman,an A.H.E.R.A.and State of Colorado Certified Asbestos
Inspector.Great care was taken during the inspection and sampling to be as
accurate as possible.It should be noted that minimal damage was done to
the existing building structures during the inspection so there is no
documentation for unseen conditions or stored items.
All samples were analyzed by DCM Science Lab in Wheat Ridge,CO.
This laboratory is deemed "Proficient"in the E.P.A.Quality Assurance (QA)
program for the determination of asbestos in bulk materials,and is accredited
by the American Hygiene Association (AHA).
Sl~MPLlNGPROTOCOL:
A random sampling scheme was used to sample the suspect materials that
were discovered.
3
A &D Asbestos Testing and Consulting
John R.Peterman
Asbestos Testing,Prcject Design,and Consulting
Residence
146 Forest Rd.
Vail,CO.
RENOVATION AREA DESCRIPTION:
The area of the residence that is planned for renovation are located in several
areas.The exterior walls are covered with wood siding.The interior walls are
covered in sheetrock with a light texture.The ceiling is covered with
sheetrock like the walls.The floor is covered in wood,stone and carpet.
CONCLUSIONS &RECOMMENDATIONS:
Laboratory analysis,of the bulk samples,indicates that no Asbestos was
detected in any of the samples.
4
T
Date:8/612013 1I
<
'location:Res~e~146ForestRd.Vail,Co.
SAMPLE LOCATIONS 1 ~
1
SAMPLE NUMBER AREA SAMPLEREMOVEDFROM 'DESCRIPTION I FRIABLE
14&-8 001 ti ~torage Under Stairs Wall j ,Composite Sheetrock WI Texture l NO
146-8 ,002 SwdyWali CompositeSbeetrockWi Texture 1 I NO
146-8 003 I.Gues.t Bedroom #1 -Composite Sheetrock WI Texture -;--:NO
146-8 '094.J Guest Master Bathroom Wall Composite Shee~'!'IlTexture ~+NO
146-8 005!Guest Master Bedroom 'Wall Co~poslt8 Sheetrock WI Texture L ~NO
,Date:
~..
location:
+
j.
81612013
j.-T
,
!
-+-
...,
Residence 146 Forest Rd.Vall,Co.
t -r
NUMBER
146-B 001
146-8 002
146-B 00.3
146-8 004
'146-B 005--r--
ISAMPLE.RESUt TS
DESCRIPTION
,Composite Sheeb:ock '!IITexture
,~mposlte Sheetrock WI Texture
1 Composite Sheetrock WI Texture
I Composite Sheetrock WI Texture
Composite Sheetrock W!Texture
'NAO INo Asbestos Detected
KEY:
ASBESTOS TYPE
,
NAD
NAD
NAD
NAD
NAD
%
0..00
0.00
0.00
0.00
0.00
-i
Date:
location:
SAMPLE
146-8
146-8
146-8
146-8
146-8
KEY:
81612013'
Residence 146 Forest Rd.Vail,Co.
SUSPECT MATERIAL CONDITION
NUMBER ITYPE OF SUS-PECT MATERIAL
001 t :.SUR
002 SUR
003 I SUR004~SUR005+-SUR
SUR -Surfacing
+
..j..__.J-~
'OVERAll CONDITION DAMAGED I %r TYPE-OF DAMAGE
GOOD ~:NO 0 NlA
GOOD NO 0 NlA
GOOD t NO 0 NJA~--GOOD ~J NO 0 NlA
GOOD NO 0 ,NlA
+----.......
+
Date:81612013
I
Location:rResidence 146 Forestl'Rd~"Vail,Co.
I
.IPOT.DIST.
Sample Number Accesslb:ility Potential
yesl,!o contad
1~
146-8
146-8
146-8
146-8
001 YES
002 YES
003 YES
004 YES
005 '¥ES-.-
HIGH
HIGH
HIGH
HIGH
HIGH
+Influence Potential Plenumr-vibration air erosion yes/no-
.-lOW I LOW NO
LOW t t lOW NO
LOW I ,LOW NO+lOW I-lOW NOttOWILOWNOLL..
Date:8I6flO13
location:1Residence 146 Forest Rd.Vall.Co.
SAMPLE NUMBER TYPE OF SUSPECT MATERIAL OVERALL CONDITION i DAMAGED %lYPE OF DAMAGE
I
146-8 001 SUR I GOOD I-NO 0 PHYSJOET
146-8 SUR ~t-GOOD t NO 0 PHYSIDET002~t ,-146-8 003 SUR I ,GOOD NO 0 PHYSIDETI
146-8 004 SUR ..1-GOOD NO 0 PHYSIDETII.~~I146-8 005 SUR I GOOD 1 NO 0 PHYSIDETI
~
t-KEY:
SUR -SwfacIng ~~
CLIENT:
DRAFT ~R.l9.NM'1C..~-WIOOAl'OOY.,""
l242:1 W.4!ITH AVBNUB,UNIT M6
WHl!AT RIDGE,CO 80033 (303)<163-1270
BULK ASBESTOS TEST REPORT
PAGE IOF3
A&D ASBESTOS TESTING AND CONSULTING
P.O.BOX 1230
CLIFTON,CO 81520-1230
ANALYSIS DATE:
REPORTING DATE:
RECEIPT DAlE:
CLIENT JOB NO.:
PROJECT TInE:DCMSLPROJECT:
PERCENTAGE COMPOSlTIONBY VISUAL ESTlMA TE
DCMSL CLIENT
S~LE S~LE
NUMBER NUMBER
-iR 146-B"()()I
S~LE PERCENT
DATE DESORIPTION OF SAMPLE
1I-2-J3 A.WHITE PAINT 3.0%
B.TAN FIBROUS 5.0010
C.WHITE TEXTURE 10.0010
D.WHITE DRYWALL 82.0010
8-2-13 A.WHITE TEXTURE 2.0010
B.GREEN WALLPAPER 4.0010
C.TAN FIBROUS 5.0010
D.WHITEDRYWALL 89.0010
8-2-13 A.TANPAINT 2.0"10
B.TAN FIBROUS 4.0"10
C.WHITE TEXTURE 12.0010
D.WHITE DRYWALL 82.0010
8-2-13 A.WHITE TEXTURE 2.0%
B.TAN FIBROUS 3.0010
C.MULTICOLORED WALLPAPER S.OO!O-
D.WHITEDRYWALL 90.0%
ASBESTOS
TYPE
-2R 146-8-002
-3R 146-8-003
-4R I46-B-004
8-5-13
8-5-13
8-5-13
RESIDENCE
146 FOREST ROAD -VAIL,CO
ADAT808
TOTAL
ASBESTOS
RANGE %IN SAMPLE
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
TOTAL
PERCENTAGE
OTHER FIBROUS NON-FIBROUS IDENTIFIED
CONSTITUENTS CONSTITUENTS MA TERlALS
NO
NO
NO
NO
0.0 100.0 100.0
100.0 0.0 100.0
0.0 100.0 100.0
TR 100,0 100.0
0.0 100.0 100.0
90.0 10.0 100.0
100.0 0.0 ,100.0
TR 100.0 100.0
0.0 100.0 100.0
100.0 0.0 100.0
0.0 100.0 100.0
TR 100.0 100.0
0.0 100.0 100.0
100.0 0.0 100.0
90.0 10.0 100.0
TR 100.0 100.0
DRAFT ~R19N¥._DC.
12421 W.49TH AVENIJIl,UNrU6
WHEAT RIDGE,00 10033 (303)463-827D
BULK ASBESTOS TEST REPORT
PAGE20F 3
CLIENT:ANAL YSI8 DATE:
REPORTING DATE:
RECEIPT DATE:
CLIENT ros NO.:
PROJECT TITLE:
OCMSL PROJECT:
8-5-13
8-5-13
8-5-1.3
RESIBENCE
l46 FOREST ROAD -VAIL,CO
ADAT808
A&D ASBESTOS TESTING AND CONSULTING
P.O.BOX 1230
CLIFTON,CO 81520-1230
PERCENTAGE COMPOSITION BY VISUAL ESTIMATE
DCMSL CLIENT
SAMPLE SAMPLE
NUMBER NUMBER
TOTAlL
TOTAL PERCENTAGE
PERCENT ASBEST0S ASBESTOS OTIffiR FffiROUS NON-FIBROUS IDENTIFIED
OF SAMPLE TYPE RANGE %IN SAMPLE CONSTITUENTS CONSTITUENTS MATERJA'LS
2.0%NO 0.0 100.0 100.0
5.0%NO 100.0 0.0 1001.0
7.0%NO 0.0 1000 100.0
86.0%ND TR 100.0 100.0
NO
SAMPLE
DATE DESCRIPTION
-SR 1·46·B..()05 A.WfUTE PAINT
B.TANFIBROUS
C.WHITE TEXTURE
D.WFDTE DRYWALL
8-2·13
FOR CALCULATION PURPOSES,TRACE (TR)IS ASSUMED TO BE'O.5%.
(1)-INSEPARABLE LAYERS ND •NONE DETECTED
THE SAMPLES WERE RECEIVED IN ACCEPT ABLE CONDITION.THIS TEST REPORT RELATES ONL Y TO TIlE ITEMS TESTED.THIS REPORT MAYNOr BE REPRODUCED EXCEPT IN FULL,
WffHOUT THE WRITTEN APPROVAL OF THE LABORATORY.