HomeMy WebLinkAboutE001.pdfF E E D E R S C H E D U L E KEY CONDUCTORS "C 20.2 G 2 # 12 , 1 # 12 G 3/4 40.2 G 2 # 8 , 1 # 10 G 3/4 20.3 G 3 # 12 , 1 # 12 G 3/4 50.3 G 3 # 6 , 1 # 10 G 1 60.3 G 3 # 4 , 1 # 10 G 1 70.3 G 3 # 4 , 1 # 8 G 1 1/4 80.3 G 3 # 3 , 1 # 8 G 1 1/4 150.3 G 3 # 1/0 , 1 # 6 G 1 1/2 50.4 G 4 # 6 , 1 # 10 G 1 1/4 60.4 G 4 # 4 , 1 # 10 G 1 1/4 70.4 G 4 # 4 , 1 # 8 G 1 1/4 80.4 G 4 # 3 , 1 # 8 G 1 1/4 100.4 G 4 # 1 , 1 # 8 G 1 1/2 125.4 G 4 # 1/0 , 1 # 6 G 2 150.4 G 4 # 1/0 , 1 # 6 G 2 175.4 G 4 # 2/0 , 1 # 6 G 2 200.4 G 4 # 3/0 , 1 # 6 G 2 1/2 200.4GX1 3 # 3/0, 1#400 N, 1 # 6 G 2 1/2 400.4 G 2 [ 4 # 3/0 , 1 # 3 G 2 1/2 ] 450.4 G 2 [ 4 # 4/0 , 1 # 2 G 2 1/2 ] 500.4 G 2 [ 4 # 250 , 1 # 2 G 3 ] 500.4 GX 2 [ 4 # 250 , 1 # 2 G 2 1/2 ] 1200.4 G 4 [ 4 # 350 , 1 # 3/0 G 3 ] 1 G 1 # 8 G 3/4 2 G 1 # 6 G 3/4 3 G 1 # 4 G 3/4 4 G 1 # 2 G 3/4 5 G 1 # 1/0 G 3/4 6 G 1 # 2/0 G 3/4 7 G 1 # 3/0 G 3/4 MEC SEE MECH'L EQUIPMENT SCHEDULE XFMR SEE TRANSFORMER SCHEDULE T R A N S F O R M E R S C H E D U L E KEY (6) HV FLA LV FLA HV PROT (1) HV PROT (1) HIGH VOLTAGE FEEDER (3) LV PROT (2) LV PROT (2) LOW VOLTAGE FEEDER (3) GROUNDING (4) DIMENSIONS (5) WEIGHT BTUH NOTE 480 V 208 V CCT BRKR SWITCH FUSE CONDUCTORS "C CCT BRKR SWITCH FUSE CONDUCTORS "C CNDTRS "C HIGH WIDE DEEP (5) OTPT (5) T15 18.0 41.6 25 A 3 P 30 A 3 P FRS-R- 25 3 # 10 , 1 # 10 G 3/4 50 A 3 P 60 A 3 P FRN-R- 50 4 # 6 , 1 # 8 G 1 1 # 8 3/4 27.00 20.13 16.00 310 2806 T30 36.1 83.3 45 A 3 P 60 A 3 P FRS-R- 45 3 # 6 , 1 # 10 G 1 100 A 3 P 100 A 3 P FRN-R- 100 4 # 2 , 1 # 8 G 1-1/4 1 # 8 3/4 30.00 20.13 16.00 370 5753 T45 54.1 124.9 70 A 3 P 100 A 3 P FRS-R- 70 3 # 4 , 1 # 8 G 1-1/4 150 A 3 P 200 A 3 P FRN-R- 150 4 # 1/0 , 1 # 6 G 2 1 # 6 3/4 39.25 26.13 20.00 480 7425 T112.5 135.3 312.3 175 A 3 P 200 A 3 P FRS-R- 175 3 # 2/0 , 1 # 6 G 2 400 A 3 P 400 A 3 P FRN-R- 400 2 [ 4 # 3/0 , 1 # 4 G 2-1/2 ] 1 # 4 3/4 39.25 30.00 24.00 725 14168 TK4-45 54.1 124.9 70 A 3 P 100 A 3 P FRS-R- 70 3 # 4 , 1 # 8 G 1-1/4 150 A 3 P 200 A 3 P FRN-R- 150 5 # 1/0 , 1 # 6 G 2 1 # 6 3/4 39.38 26.13 20.00 480 7203 7 TK4-75 90.2 208.2 110 A 3 P 200 A 3 P FRS-R- 110 3 # 1 , 1 # 6 G 1-1/2 250 A 3 P 400 A 3 P FRN-R- 250 5 # 250 , 1 # 2 G 2-1/2 1 # 2 3/4 39.38 26.13 24.00 865 9696 7 NOTES: 1.) PRIMARY O.C. PROTECTION PER NEC 450-3. 2.) SECONDARY O.C. PROTECTION PER NEC 450-3. 3.) ALL CONDUCTORS ARE COPPER. SEE PLANS FOR INCREASED CONDUCTOR SIZES DUE TO VOLTAGE DROP ETC. 4.) BONDING AND GROUNDING CONDUCTOR PER NEC 250-66. 5.) DIMENSIONS, WEIGHTS & BTUH OUTPUT SHOWN ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY FROM MANUFACTURER TO MANUFACTURER. 6.) BRANCH CIRCUITS TO HAVE A DEDICATED NEUTRAL FOR EACH CIRCUIT ON K-RATED TRANSFORMERS. 7.) FOR K-RATED TRANSFORMERS, PROVIDE PARALLEL NEUTRAL CONDUCTORS LUGS AT TRANSFORMERS, LOW VOLTAGE PANELBOARD, DISCONNECTS AND/OR LOAD . 08/28/14