HomeMy WebLinkAbout2722 Cortina Lane - Sheet - A10-0 - ELECTRICAL SCHEDULE AND NOTES.pdfTELEPHONE/
DATA
GFI
WP
220
TV
FAN
3
D
DUPLEX OUTLET
SWITCHED OUTLET (ONE SIDE ONLY)
GROUND FAULT INTERRUPT OUTLET
WATER PROOF GFI OUTLET
220 OUTLET
FLOOR MOUNTED DUPLEX
TELEVISION / PROVIDE 2 RG-6 AND 2 CAT-V
2 CAT V TELEPHONE
RECESSED DIRECTIONAL DOWN LIGHT
FLAT OR SLOPED CEILING
RECESSED 4-LIGHT MULTIPLE
DIRECTIONAL DOWN LIGHT
SURFACE MOUNTED FIXTURE @ WALL
WALL MOUNTED UP LIGHT FIXTURE
WALL MOUNTED STEP LIGHT FIXTURE
SURFACE MOUNTED FLORESCENT
SURFACE MOUNTED ON CEILING
LED LIGHTING UNDER CABINET LIGHTING
SURFACE MOUNTED FLORESCENT MOUNTED ABOVE DOOR HEAD
JUNCTION BOX
EXHAUST FAN
SWITCH
3-WAY SWITCH / 4-WAY SWITCH
DIMMER SWITCH (MAY BE SHOWN AS 3-WAY)
MONOPOINT
J-BOX
MOTORIZED SHADE W/ BUILT-IN POCKET
TRU- FIG DUPLEX OUTLET
TF
DUPLEX OUTLET W/ (2) USB PORTS
USB
GENERAL NOTES:
1. LOCATION OF OUTLETS AND OTHER ELECTRICAL DEVICES IS DIAGRAMMATIC -- ACTUAL PLACEMENT
OF ELEMENTS, WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF
LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND ORDINANCES.
2. OUTLETS TO BE LOCATED 16" ABOVE FINISHED FLOOR, AND SWITCHES 42" ABOVE FINISHED FLOOR,
UNLESS OTHERWISE SPECIFIED. AT LOCATIONS WHERE THIS IS NOT POSSIBLE, CONSULT THE
ARCHITECT.
3. PROVIDE SMOKE DETECTORS AS REQUIRED. SMOKE DETECTORS WILL BE CONNECTED TO THE
MONITERED FIRE ALARM SYSTEM
4. ALL DIMENSIONS TO CENTER LINE OF FIXTURE. COORDINATE FIXTURE LOCATION WITH STRUCTURE
AND TO ALIGN AND CENTER FIXTURES AS CLOSE AS POSSIBLEPROVIDE GFI OUTLET IN EVERY
VANITY @ ONE SINK IN CABINET, EXCEPT FOR POWDER ROOMS.
5. COORDINATE SWITCHED OUTLETS LOCATIONS AT VANITY WALLS AND FLOORS WITH FURNITURE
PLANS AND INTERIOR DOCUMENTS
6. PROVIDE CARBON MONOXIDE DETECTORS THROUGHOUT THE HOUSE PER R315. CARBON MONOXIDE
DETECTORS WILL BE CONNECTED TO THE MONITERED FIRE ALARM SYSTEM.
7. OUTLETS ABOVE VANITIES TO BE VERTICAL WITH CENTERLINE AT 46" AFF EXCEPT AS NOTED.
VERIFY LOCATION & HEIGHT WITH OWNER
8. VERIFY ALL APPLIANCE ELECTRICAL LOADS WITH OWNER SPECS.
9. PROVIDE POWER AS REQUIRED PER MECHANICAL CONTRACTOR AND SPEC.
10. COORDINATE OUTLETS W/ FURNITURE PLANS PER OWNER
11. PROVIDE J-BOX FOR HEAT TAPE LOW ON WALL @ ALL DOWNSPOUT LOCATIONS
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
8/18/2014 3:15:27 PM
1/4" = 1'-0"
2722 CORTINA LANE
VAIL RIDGE SUBDIVISION, BLOCK B,
LOT 13 , VAIL CO
A10.0
ELECTRICAL
SCHEDULE
AND NOTES
8-18-14
BKW
HB
8-18-14
BUILDING PERMIT
1/4" = 1'-0"
ELECTRICAL LEGEND
Lighting Fixture Schedule
Type Mark Type Manufacturer Model Type Comments Count
Lamp
Count
A FLAT CEILING RECESSED CAN 4" LINE VOLTAGE
UNIVERSAL IC HOUSING -
PAR 20 LAMP
52
A3 FLAT CEILING MOISTURE RESISTANT
RECESSED CAN
4" LINE VOLTAGE
UNIVERSAL IC HOUSING -
PAR 20 LAMP
4 4
A4 FLAT CEILING EXTERIOR RECESSED
CAN - HIGH EFFICACY
LIGHTOLIER 1050RNDLCDW -
1050LRN0927 / 2700K LED
18 18
B SLOPED CEILING RECESSED CAN 4" LOW VOLTAGE
UNIVERSAL IC HOUSING -
50W MR16
35 35
C WALL MOUNTED SCONCE UPLIGHT BELFER 6230 VARIAL 6 6
D DECORATIVE SCONCE PER OWNER BY INTERIOR DESIGNER BY INTERIOR DESIGNER - COORDINATE LINE VOLTAGE OR LOW
VOLTAGE
3 14
D2 7 14
E EXTERIOR SCONCE HEVI LITE HL-374-BZ, MOUNTED @
6'-0" ABOVE FINISHED
FLOOR
PAR-20 BRONZE POWDER COAT FINISH (BZ) 5 6
H 1X4 FLORESCENT - HIGH EFFICACY GARAGE AND MECHANICAL (2 32 W FLORESCENT LAMPS PER FIXTURE) 7 10
J J-BOX CEILING FAN RATED 7 0
L UNDER CABINET LED ROPE LIGHT-
HIGH EFFICACY
JESCO FLEX- UPHO LED LINEAR LIGHTING STRIP, 18 LED LAMPS PER 1' 5 242
M MONOPOINT SURFACE MOUNTED HEVI LITE HL-384-BZ INTEGRAL LOW VOLTAGE TRANSFORME, 50W MR-15 BI-PIN HALOGEN,
BRONZE
13 13
P PENDANT LIGHT TECH LIGHTING 700-FJ-CON-W-S LOW VOLTAGE CONE PENDANT, WHITE FINISH 4 4
Grand total: 166
LIGHTING EFFICACY CALCULATIONS:
TOTAL FIXTURE COUNT = 174
TOTAL LAMP COUNT = 409
TOTAL HIGH EFFICACY LAMP COUNT = 270
174 FIXTURES WITH 409 LAMPS ARE PROPOSED IN HOUSE. 270 LAMPS
ARE HIGH EFFICACY.
270/409 =.66
66% OF LAMPS IN THE HOUSE ARE HIGH EFFICACY WHICH EXCEEDS THE
REQUIREMENT OF 50% IN N1104.951