Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2722 Cortina Lane - Sheet - A10-1 - LOWER LEVEL RCP.pdf
A4.3 A4.1 1 1 A4.2 1 A4.4 1 6" BEDROOM 2 005 BEDROOM 3 006 CLOSET 007 CLOSET 008 CLOSET 003 BATH 2 004 MECH 001 LAUNDRY 002 BATH 3 009 FAMILY ROOM 011 BATH 4 013 BEDROOM 4 012 CLOSET 014 1 1 2 2 3 3 4 4 5 5 6 6 7 7 9 9 10 10 11 11 A B C D E F G H I E 3' - 9" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 2' - 0 3/16" 3' - 3" 2' - 0" 3' - 0" FAN FAN A J A A A A A A A A A J A A A A A A A A A A A A3 A A A4 A4 A4 A3 A J 1' - 11 1/2" 4' - 8 1/2" 4' - 8 1/2" L FAN FAN A A A TO LIGHTS AND SWITCHES ABOVE GFI D D A A A A4 A4 2' - 6" 3' - 5 1/2" 2' - 6" A4 10' - 7" D2 BELOW CNTR GFI WASHER DRYER BELOW CNTR 220 GFI A4 A4 6" A4 J-BOX J-BOX J-BOX FOR DOWN SPOUT J-BOX FOR DOWN SPOUT TV TV TV TV TVTELEPHONE/ DATA TELEPHONE/ DATA TELEPHONE/ DATA TELEPHONE/ DATA 6X12 6X12 6X12 D2 WP HOSE BIB HOSE BIB HOSE BIB GFI OUTLET CENTERED BELOW EA. SCONCE 8 8 A4 W10X68 W12X50 W12X50 W12X50 W12X50 D2 GFI GFI B.O. STEEL BEAM @ 44' - 2 3/4" B.O. STEEL BEAM @ 44' - 2 3/4" B.O. STEEL BEAM @ 44' - 2 3/4" B.O. STEEL BEAM @ 44' - 2 3/4" B.O. STEEL BEAM @ 45' - 3" B.O. FINISHED CEILING @ 45' - 2 1/2" B.O. FINISHED CEILING @ 43' - 5 3/8" B.O. FINISHED CEILING @ 45' - 2 1/2" B.O. FINISHED CEILING @ 45' - 2 1/2" B.O. FINISHED CEILING @ 43' - 6" B.O. FINISHED CEILING @ 43' - 6" B.O. FINISHED CEILING @ 43' - 5 3/8" B.O. FINISHED CEILING @ 43' - 6" B.O. FINISHED CEILING @ 43' - 5 3/8" B.O. FINISHED CEILING @ 38' - 9 3/8" B.O. FINISHED CEILING @ 43' - 5 3/8" B.O. FINISHED CEILING @ 43' - 5 3/8" B.O. FINISHED CEILING @ 45' - 2 1/2" B.O. FINISHED CEILING @ 45' - 2 1/2" B.O. FINISHED CEILING @ 44' - 11 7/8" GENERAL NOTES: 1) EXTERIOR LIGHTING: 1 LIGHT PER 1,000 SF OF LOT AREA, THEREFORE 19 LIGHTS ARE ALLOWED. 19 EXTERIOR LIGHTS 18" ABOVE GRADE ARE PROPOSED. SEE ELECTRICAL PLANS FOR TYPE, LOCATION AND NUMBER OF FIXTURES. ________________________________________ 2 TOTAL EXTERIOR LIGHTS MOUNTED MORE THAN 18" ABOVE GRADE AT THIS LEVEL US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 8/18/2014 3:15:46 PM 1/4" = 1'-0" 2722 CORTINA LANE VAIL RIDGE SUBDIVISION, BLOCK B, LOT 13 , VAIL CO A10.1 LOWER LEVEL RCP 8-18-14 BKW HB 8-18-14 BUILDING PERMIT 1/4" = 1'-0" 1 LOWER LEVEL REFLECTED CEILING PLAN 1/4" = 1'-0" GENERAL NOTES - LOWER LEVEL REFLECTED CEILING PLAN REVISION SCHEDULE # DESCRIPTION DATE 09/17/14