Loading...
HomeMy WebLinkAbout2722 Cortina Lane - Sheet - A10-2 - MAIN LEVEL RCP.pdfA4.3 A4.1 1 1 A4.2 1 A4.4 1 3" 7 1/16" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 1' - 11" 1' - 0" GARAGE 113 MUDROOM 111 ENTRY 101 STAIRS 102 DINING ROOM 103 LIVING ROOM 110 KITCHEN 104 PANTRY 106 OFFICE 105 MASTER BEDROOM 107 MASTER CLOSET 108 MASTER BATH 109 SHOWER 109B W.C. 109C 1 1 2 2 3 3 4 4 5 5 6 6 7 7 9 9 10 10 11 A B C D E F G H I M M M M M M M M E E 2' - 0" M M E E 19' - 7 9/16" 16' - 4 1/2" 4' - 0" 2' - 0" EQ EQ 2' - 0" 4' - 3 3/4" 1' - 0" 5' - 0 1/8" 1' - 0" 2 1/8" 3' - 11 1/2" 2 1/8" 3' - 3" 2' - 1 7/8" 2' - 1 7/8" EQ EQ 13' - 0" 7' - 6 1/2" FAN EQ EQ FAN M M D2 D2 D2 A A A A A A B B B B B B B B B B B B B J B B B B B B B A D2 A3 A A A3 A A A A B A A B B B B B B J B B B B B B B P P P P B C C C M C C C C FAN J 2 1/2" / 12" 2 1/2" / 12" 2 1/2" / 12" 2 1/2" / 12" B.O. FINISHED CEILING @ 57' - 4 1/4" 57' - 2 3/8" B.O. FINISHED CEILING @ 55' - 5 3/8" B.O. FINISHED CEILING @ 54' - 11 1/4" B.O. FINISHED CEILING @ 57' - 2 3/8" 47' - 10 1/2" TO SWITCHES BELOW A4 A4 A4 A4 TELEPHONE/ DATA TELEPHONE/ DATA TV L L L L SWITCHED OUTLETS FOR LOW- VOLTAGE TRANSFORMERS TV TV A4 WP J-BOX J-BOX FOR DOWNSPOUT A A4 A4 A4 GFI GFI GFI DISPOSAL WP WP J 220 GFI GFI GFI INSIDE CABINET RANGE HOOD 220 WASTE LINE FOR FUTURE BATH ABOVE PROVIDE 5/8" TYPE X GYP @ WALLS, CEILING AND STEEL BEAM IN GARAGE HOT AND COLD HOSE BIB TO SWITCHES AND LIGHTS ABOVE DROP DOWN ATTIC LADDER TO STORAGE ABOVE B.O. FINISHED CEILING @ 57' - 2 3/8" W10X22 W10X22 W10X22 W10X22 W10X22 W10X22 6X10 2' - 0" W14X61 W10X30 W18X60 W10X22 8X8 6X10 W6X20 8 8 DW GFI GFI B.O. STEEL BEAM @ 60' - 2 1/8" B.O. STEEL BEAM @ 60' - 11" B.O. STEEL BEAM @ 63' - 4 3/4" B.O. STEEL BEAM @ 65' - 0 3/4" B.O. STEEL BEAM @ 67' - 8 1/2" B.O. STEEL BEAM @ 70' - 4 1/4" B.O. STEEL BEAM @ 55' - 7 1/4" B.O. STEEL BEAM @ 57' - 6 3/4" B.O. STEEL BEAM @ 57' - 2 5/8" B.O. STEEL BEAM @ 57' - 3" B.O. STEEL BEAM @ 59' - 10 3/8" B.O. FINISHED CEILING @ 56' - 2 1/2" B.O. FINISHED CEILING @ 55' - 5 3/8" 2 1/2" / 12" B.O. FINISHED CEILING @ 54' - 5 1/4" B.O. FINISHED CEILING @ 49' - 4 1/2" B.O. STEEL BEAM @ 58' - 10" B.O. STEEL BEAM @ 56' - 10 3/4" 6X10 6X10 6X10 6X10 GENERAL NOTES: 1) EXTERIOR LIGHTING: 1 LIGHT PER 1,000 SF OF LOT AREA, THEREFORE 19 LIGHTS ARE ALLOWED. 19 EXTERIOR LIGHTS 18" ABOVE GRADE ARE PROPOSED. SEE ELECTRICAL PLANS FOR TYPE, LOCATION AND NUMBER OF FIXTURES. (4) TYPE E LIGHTS PROVIDED @ THIS LEVEL (13) TYPE M LIGHTS PROVIDED @ THIS LEVEL ________________________________________ 17 TOTAL EXTERIOR LIGHTS MOUNTED MORE THAN 18" ABOVE GRADE AT THIS LEVEL US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 8/18/2014 3:16:05 PM 1/4" = 1'-0" 2722 CORTINA LANE VAIL RIDGE SUBDIVISION, BLOCK B, LOT 13 , VAIL CO A10.2 MAIN LEVEL RCP 8-18-14 BKW HB 8-18-14 BUILDING PERMIT 1/4" = 1'-0" 1 MAIN LEVEL REFLECTED CEILING PLAN REVISION SCHEDULE # DESCRIPTION DATE 2 REVISION 2 8-6-14 09/17/14