HomeMy WebLinkAbout2722 Cortina Lane - Sheet - A5-11 - BUILDING SECTIONS.pdfMAIN LEVEL FLOOR PLAN FINISHED FLOOR 46' - 6" UPPER LEVEL FLOOR PLAN FINISHED FLOOR 57' - 6" LOWER LEVEL FINISHED FLOOR 34' - 6" 1 A5.3 1 A5.6 1 A5.4 1 A5.5 1 A5.1 1 A5.2 MUDROOM 111 ENTRY 101 BATH 3 009 LAUNDRY 002 MECH 001 1 A5.7 5" T.O. CONC. LEDGE @ 46' - 3 3/4" A6.1 5 SIM 1 2 3 4 5 6 7 9 10 11 8 GARAGE LOFT 201 T.O. STEEL BEAM @ 58' - 1 1/8" A6.4 5 SIM T.O. CONC. WALL @ 45' - 1 5/8" A6.3 10 LAUNDRY CHUTE 2 1/2" 12" T.O. CONC. WALL @ 46' - 7" A6.4 6 B.O. HEADER @ 8' - 2 1/2" 2"2' - 0 3/4" R.O.2' - 0" 71' - 9 1/2" 6' - 0 1/2" 14' - 5 1/2" 1' - 11" 4' - 4 1/2" 6' - 4" 4' - 5" 5' - 3" 19' - 3" 4' - 9" 5' - 0" 12' - 0" 11' - 0" 1' - 4" SECTION GENERAL NOTES: 1) EXTERIOR LIGHTING IS NOTED AS: M- HEVI LITE INC HL-374 PAR-20 SURFACE MOUNT DOWN LIGHT BRONZE POWDER COAT FINISH (BZ)- (13) TOTAL FIXTURES E- HEVI LITE INC HL-384-BZ SURFACE MOUNT MONO POINT BRONZE POWDER COAT FINISH. PERMANENTLY FIXED/INSTALLED AS A DOWNLIGHT- (5) TOTAL FIXTURES 2) SEE EXTERIOR MATERIAL AND COLOR INFORMATION SHEET FOR MORE INFORMATION ON COLORS. SEE OUTLINE SPEC AND ARCHITECTURAL FINISH SCHEDULE. 3) ALL SNOW FENCES AT STANDING SEAM ROOF TO BE AN ENGINEERED SYSTEM PER ROOF TYPE AND SLOPE INSTALLED PER MANUFACTURES RECOMMENDATIONS RE: SPEC. 4) ALL DIMENSIONS / ELEVATIONS ARE FROM T.O. FINISH U.N.O. 5) WINDOW AND DOOR HEAD / SILL HEIGHTS ARE FROM T.O. FINISH. 6) ALL EXTERIOR EXPOSED STEEL HEADERS, BEAM, KNIFE PLATES, ETC, TO BE PAINTED TO MATCH BRONZE WINDOW COLOR. ENERGY CONSERVATION: THE BUILDING COMPLIES WITH THE ENERGY CONSERVATION REQUIREMENT FROM CHAPTER 4 OF THE 2012 INTERNATIONAL ENERGY CODE PER ZONE 6B ADOPTED BY THE TOWN OF VAIL, AND AS DEMONSTRATED BY PRESCRIPTIVE BUILDING THERMAL ENVELOPE, AS FOLLOWS: The following is a summary for the climate zone 6B of Table 402.1.1 requirements of the IECC and as adopted by The Town of Vail, and an outline of the proposed R values of the assemblies of the building which are defined in the Construction Document Drawings and Specifications: Maximum Glazing U-Factor of .30 for new single family dwelling units per Town of Vail amendments, this can be a weighted average. The Sierra Pacific windows and doors with dual glazed Low E glazing (Low E on two surfaces) exceeds this requiremnt - Average U-Value = .28. See 8.5 x 11 window proposal from manufacture for summary of U-values. Ceilings & Roofs Insulation - Requirement of R-49 which is reduced to R-38 per 402.2.1 since the construction techniques provide a full R-38 insulation value over the wall top plate. Typical Roof Condition - The design provides a full R-38 insulation value over the wall top plate as follows: Provide R56.4 at roof Cavities with 5/8" plywood over 14” TJIs: with 2” minimum of 2# closed cell spray foam insulation with an R value of 6.6 per inch equaling R13.2 and 12” of blown in cellulose insulation with R3.6 per inch equaling R43.2. Basement Walls Insulation - Requires R-15 of continuous insulation or R-19 cavity insulation : Provide R22.6 with R-10 exterior insulation/drainage medium over the typical 8" concrete wall and R-14.4 at 2x4 wood furring with 4" blown in cellulose insulation with R- 3.6 per inch and 5/8" drywall exceeds the requirement. Exterior Walls Insulation - Requires R-20: Exterior walls with 5.5” cavity: Provide R22.8 with 1” minimum of spray foam insulation @ inside of sheathing with an R value of 6.6 per inch equaling R6.6 and 3.5” of blown in cellulose insulation with R3.6 per inch equaling R16.2 or approved equal. Floor Insulation - Requires R-30: The building has been designed with a conditioned and finished basement space. Floor @ Master Bedroom Overhang - Provide 2" min. spray foam insulation @ underside of floor sheathing w/ an R-Value of 6.6 per inch equaling 13.2 and 9 7/8" of blown in cellulose insulation w/ R-3.6 per inch equaling R-35.55 providing a total insulation value of R-48.75. Basement Slab - Requires R-15 for 4' horizontally under slab (since the slab is heated). Provide R15 with continuous 3" rigid insulation under the slab and R-10 continuous @ exterior of foundation. Provide full cavity blown in cellulose sound insulation at all interior walls and at all floor assemblies. US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 8/18/2014 3:10:10 PM 1/4" = 1'-0" 2722 CORTINA LANE VAIL RIDGE SUBDIVISION, BLOCK B, LOT 13 , VAIL CO A5.11 BUILDING SECTIONS 8-18-14 BKW HB 8-18-14 BUILDING PERMIT 1/4" = 1'-0" 1 EAST WEST SECTION 4 LOOKING SOUTH REVISION SCHEDULE # DESCRIPTION DATE 09/17/14