HomeMy WebLinkAbout2722 Cortina Lane - Sheet - A6-4 - ROOF DETAILS.pdfCUSTOM 5" ROUND GUTTER WITH
ROUND DOWN SPOUTS RE: SPEC
RE: ROOF PLANS FOR LOCATIONS
RE: ROOF PLAN / SECTIONS
GRID
LINE
DRIP EDGE FLASHING
RE: SPEC
STANDING STEAM ROOF
RE: SPEC RE: ROOF PLAN
FOR LOCATIONS
ICE AND WATER SHIELD OVER
METAL FLASHING PROVIDE
50% OVERLAP (DOUBLE
LAYER) FOR FIRST 4' UP EAVE
2X6 DOUG-FIR DECKING
2X6 CEDAR FASCIA RE: ROOF
PLAN FOR LOCATIONS
6x10 ROUGH SAWN DOUG-FIR RAFTER TAILS @
48" O.C. PORTER STAIN COLOR SIERRA BROWN.
RAFTERS SISTERED TO TJI RAFTERS TYP.
INSULATION RE: SPEC & COVER SHEET
WOOD SIDING (REFER TO
ELEVATIONS FOR LOCATIONS) RE:
SPEC
EXTEND ROOF SHEATHING TO EDGE OF EAVE
PLATE HEIGHTS AT SECTIONS AND
ELEVATIONS ARE PER A BEVEL PLATE
(RAFTER NOT SEAT CUT)
2.5:12
PER ROOF PLAN
3D DRAINAGE MEDIUM CONT. BEHIND SIDING TO
AIR VENT MATERIAL AT TOP OF WOOD SIDING
SMART MEMBRANE VAPOR BARRIER
TYP. RE: SPEC
PRE FINISHED METAL GUTTER AND
DOWN SPOUT RE: SPEC
PFSM DRIP EDGE FLASHING
RE: SPEC
STANDING STEAM METAL ROOF RE:
SPEC AT 1.5:12
ICE AND WATER SHIELD OVER
METAL FLASHING PROVIDE
50% OVERLAP (DOUBLE
LAYER) FOR FIRST 4' UP FROM
EAVE
2X6 DOUG-FIR DECKING
2X6 CEDAR FASCIA
6X10 ROUGH SAWN DOUG-
FIR RAFTER TAIL RE: RCP &
ELEVATIONS
RAFTERS BIRDS MOUTH CUT TO
ALLOW I-BEAM TO SIT FLUSH
10X10 DOUG-FIR COLUMN @
SHED ROOF OVER DECK AT
MAIN FLOOR
STEEL I-BEAM RE: STRUCT.
RE: ROOF PLAN
KNIFE PLATE WITH SURFACE
MOUNTED THROUGH BOLTS RE:
STRUCT.
12
2.5"
EXTEND ROOF SHEATHING TO EDGE
OF EAVE
9 1/4"
3"
4X4 TUBE STEEL FULLY
WELDED TO 8 1/2" X 8 1/2" X
1/2" STEEL CAP W/ KNIFE
PLATE RE: STRUCT.
RAFTERS LAG-BOLTED FROM
BELOW RE: STRUCT.
GRID
LINE
6X10 RAFTER TAIL ATTACHED
TO WOOD RAFTERS @ 48" O.C.
RE: STRUCTURAL DRAWINGS
DRIP FLASHING OVER
FASCIA RE: SPEC
STANDING SEAM METAL
ROOFING
RE: SPEC
5/8" PLYWOOD SHEATHING
INSULATION RE: SPEC
6X10 WOOD RAFTER LAG
BOLTED TO EXTERIOR WALL -
LAG BOLTS TO BE COUNTER
SUNK AND PLUGGED
2X4 BLOCKING
PLYWOOD BLOCKING
EXTEND ROOF SHEATHING
TO EDGE OF ROOF
TYP. EXTERIOR WALL
ASSEMBLY RE:
ELEVATIONS / SECTIONS
CANTILEVERED 2X6 T&G
DECKING
VARIES PER OVERHANG
RE: ROOF PLAN
CONTINUOUS 2X8
CUSTOM 5" ROUND GUTTER WITH
ROUND DOWN SPOUTS RE: SPEC
RE: ROOF PLANS FOR LOCATIONS
GRID
LINE
DRIP EDGE FLASHING
RE: SPEC
STANDING STEAM ROOF
RE: SPEC RE: ROOF PLAN
FOR LOCATIONS
ICE AND WATER SHIELD OVER
METAL FLASHING PROVIDE
50% OVERLAP (DOUBLE
LAYER) FOR FIRST 4' UP EAVE
2X6 DOUG-FIR DECKING
2X6 CEDAR FASCIA RE: ROOF
PLAN FOR LOCATIONS
6x10 ROUGH SAWN DOUG-FIR RAFTER TAILS @
48" O.C. PORTER STAIN COLOR SIERRA BROWN.
RAFTERS SISTERED TO TJI RAFTERS TYP.
INSULATION RE: SPEC & COVER SHEET
WOOD SIDING (REFER TO
ELEVATIONS FOR LOCATIONS AND
TYPE) RE: SPEC
EXTEND ROOF SHEATHING TO EDGE OF EAVE
PLATE HEIGHTS AT SECTIONS AND
ELEVATIONS ARE PER A BEVEL PLATE
(RAFTER NOT SEAT CUT)
2.5:12
PER ROOF PLAN
3D DRAINAGE MEDIUM CONT. BEHIND SIDING TO
AIR VENT MATERIAL AT TOP OF WOOD SIDING
SMART MEMBRANE VAPOR BARRIER
TYP. RE: SPEC
T.O. WALL
RE: SECTS AND ELEVS
W12X26 EXPOSED STEEL BEAM RE:
STRUCT.
CENTERLINE OF STEEL
3 3/8"
GRID
LINE
STANDING SEAM METAL ROOF
RE: SPEC
2X6 T&G DECKING
ICE AND WATER SHIELD CONT.
UP WALL 36" MIN.
RE: SPEC
12
2.5"
LAPPED RAFTERS ATTACHED
TO STUDS OR SOLID
BLOCKING RE: STRUCT.
STANDING SEAM METAL ROOF
RE: SPEC
RUN METAL FLASHING UP WALL
MIN 6" EXTEND OVER ROOFING
MIN 6"
LAP SELF ADHERING BITUTHANE
FLASHING OVER METAL WALL
FLASHING
LAP BLDG PAPER OVER
BITUTHANE FLASHING
GRID
LINE
6X10 RAFTER TAIL ATTACHED
TO WOOD RAFTERS @ 48" O.C.
RE: STRUCTURAL DRAWINGS
DRIP FLASHING OVER
FASCIA RE: SPEC
STANDING SEAM METAL
ROOFING RE: SPEC
5/8" PLYWOOD SHEATHING
INSULATION RE: SPEC
6X10 WOOD RAFTER LAG
BOLTED TO EXTERIOR WALL -
LAG BOLTS TO BE COUNTER
SUNK AND PLUGGED
PLYWOOD BLOCKING
EXTEND ROOF SHEATHING
TO EDGE OF ROOF
TYP. EXTERIOR WALL
ASSEMBLY RE: ELEVATIONS /
SECTIONS
CANTILEVERED 2X6 T&G
DECKING
VARIES PER OVERHANG
RE: ROOF PLAN
CONTINUOUS 2X8
STEEL INTERIOR BEAM
RE: STRUCT.
STEEL EXTERIOR BEAM
NOTCHED AND WELDED TO T.O.
INTERIOR STEEL BEAM
RE: STRUCT.
1 1/2"
BEVELED PLATE ON T.O.
INTERIOR STEEL BEAM
RE: STRUCT.
RE: SECTIONS
3"
EQ EQ
TYPICAL RECLAIMED WOOD
SIDING ASSEMBLY
(5) 2X6 POST RE:
STRUCT
1/2" STEEL PLATE LAG
BOLTED TO (5) 2X6 POST.
PLATE ATTACHES
DIRECTLY OVER STUDS
RE: STRUCT
4"
3"
1"
8X8 WOOD STRUT W/ KNIFE
PLATE CONNECTION TO WALL
W/ SURFACE MOUNTED THRU-
BOLTS RE: STRUCT
4"
1' - 4"
LINE OF KNIFE PLATE INSIDE
WOOD STRUT
*NOTE - KNIFE PLATE IS
SHOWN DIAGRAMMATICALLY
RE: STRUCT FOR ACTUAL
KNIFE SIZES AND REQUIRED
BOLT PATTERN
& ELEV.
RE: SECTIONS
WRAP KNIFE PLATE W/ICE AND
WATER SHIELD FOR 3/4" DEPTH OF
SIDING. PROVIDE SEALANT JOINT
BETWEEN WOOD AND KNIFE PLATE -
PAINT KNIFE PLATE TO MATCH
WINDOW COLOR
DRIP EDGE FLASHING RE:
SPEC
ROOF ASSEMBLY RE: ROOF
PLAN & ROOF DETAILS
ICE AND WATER SHIELD OVER
METAL FLASHING PROVIDE 50%
OVERLAP (DOUBLE LAYER) FOR
FIRST 4' UP FROM ROOF EAVE
2X6 T&G DECKING RE: SPEC
CEDAR FASCIA RE: ROOF
PLANS
6x10 AT 2.5:12 ROOF ROUGH
SAWN DOUG-FIR RAFTER
TAIL SISTERED TO TJI
RAFTERS RE: RCP
8X8 DOUG-FIR STRUT
STEEL I-BEAM RE: STRUCT.
KNIFE PLATE WITH SURFACE
MOUNTED THROUGH BOLTS
RE: STRUCT.
KNIFE PLATE WITH SURFACE
MOUNTED THROUGH BOLTS
RE: STRUCT.
RE: SECTIONS & ELEV.
20.0°
RE: SECTIONS / ELEVATIONS SLOPE PER ROOF PLAN
CUSTOM 5" ROUND GUTTER WITH
ROUND DOWN SPOUTS RE: SPEC
RE: ROOF PLANS FOR LOCATIONS
GRID
LINE
DRIP EDGE FLASHING
RE: SPEC
STANDING STEAM ROOF
RE: SPEC RE: ROOF PLAN
FOR LOCATIONS
ICE AND WATER SHIELD OVER
METAL FLASHING PROVIDE
50% OVERLAP (DOUBLE
LAYER) FOR FIRST 4' UP EAVE
2X6 DOUG-FIR DECKING
2X6 CEDAR FASCIA RE: ROOF
PLAN FOR LOCATIONS
6x10 ROUGH SAWN DOUG-FIR
RAFTER TAILS @ 48" O.C. PORTER
STAIN COLOR SIERRA BROWN.
RAFTERS SISTERED TO TJI
RAFTERS TYP.
INSULATION RE: SPEC &
COVER SHEET
EXTEND ROOF SHEATHING
TO EDGE OF EAVE
JOIST HANGER RE: STRUCT
2.5:12
PER ROOF PLAN
SMART MEMBRANE VAPOR BARRIER
TYP. RE: SPEC
3 3/8"
CENTERLINE OF STEEL
1/2"
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue
Date
8/18/2014 3:11:33 PM
1 1/2" = 1'-0"
2722 CORTINA LANE
VAIL RIDGE SUBDIVISION, BLOCK B,
LOT 13 , VAIL CO
A6.4
ROOF
DETAILS
8-18-14
BKW
HB
8-18-14
BUILDING PERMIT
1 1/2" = 1'-0"
1
ROOF EAVE DETAIL - TYPICAL
1 1/2" = 1'-0"
2
ROOF EAVE DETAIL @ FRONT ENTRY
COLUMN
1 1/2" = 1'-0"
4 ROOF RAKE DETAIL -TYPICAL
1 1/2" = 1'-0"
3
ROOF EAVE DETAIL @ LIVING ROOM
EXPOSED BEAM
1 1/2" = 1'-0"
5
WALL DETAIL - STONE VENEER @ SHED
ROOF CONNECTION
1 1/2" = 1'-0"
7
ROOF RAKE DETAIL @ STEEL OUTLOOK
BEAM
1 1/2" = 1'-0"
8 STRUT DETAIL @ WALL CONNECTION
1 1/2" = 1'-0"
9 STRUT DETAIL @ ROOF EAVE ASSEMBLY
1 1/2" = 1'-0"
6
ROOF EAVE DETAIL @ FRONT ENTRY
WINDOW
REVISION SCHEDULE
# DESCRIPTION DATE
09/17/14