HomeMy WebLinkAbout2722 Cortina Lane - Sheet - A7-1 - FIREPLACE SHEET.pdfGENERAL NOTES: 1.) INSTALL GAS LOG SET AND BURNER PER MANUFACTURERS SPECIFICATION. CONTRACTOR TO HAVE A COPY OF THE SPECIFICATIONS AND INSTALLATION REQUIREMENTS ON SITE SO INSPECTOR CAN VERIFY PROPER INSTALLATION. 2.) INSTALL EXCEL MODEL RIS CHIMNEY @ LIVING ROOM, HEARTH ROOM, AND OUTDOOR FIREPLACES PER MANUFACTURERS SPECIFICATION. CONTRACTOR TO HAVE A COPY OF THE SPECIFICATIONS AND INSTALLATION REQUIREMENTS ON SITE SO INSPECTOR CAN VERIFY PROPER INSTALLATION. 4" STONE CHIMNEY CAP PAINTED TO MATCH WINDOW COLOR 4X4 TUBE STEEL POST CANTED AT 1:12 WELDED TO 1/2" X 6" X 4" STEEL PLATE AT TOP AND BOTTOM SET IN A BED OF SEALANT OVER FLASHING, FASTENED WITH LAG BOLTS INTO FRAMING BELOW AND EXPANSION BOLTS INTO STONE ABOVE FLASHING OVER W.P. MEMBRANE OVER SLOPED 1 1/8" PLYWOOD AS REQ'D STEEL ANGLE RE: STRUCT LAP W.P. MEMBRANE OVER FLASHING 1 1/2" MIN. TYP. STONE WALL ASSEMBLY. 7 1/8" 6' - 3 1/2" COUNTER FLASHING SET IN SEALANT TYP. STORM COLLAR FLASHING SET IN SEALANT OVER COUNTER FLASHING TYP. 4' - 0" 4" MECHANICAL PVC VENTS ROUTED THRU 2X8 WALL AND DRILLED THRU CHIMNEY CAP 2" PROVIDE SOLID BLOCKING UNDER STEEL COLUMNS FILL 2X10 CAVITY WITH INSULATION TYPE X 5/8" DRYWALL CONT. @ INSIDE OF CHASE FROM T.O. PLYWOOD SUB FLOOR TO B.O. SHEATHING 2X10 JOISTS W/ TOPS CUT TO SLOPE PLY WOOD ABOVE @ 1/8" PER 1'-0" MAINTAIN 2" CLEARANCE TO COMBUSTIBLES 1' - 8" 2 1/4" 1' - 4" 2" MIN 1' - 0" TERMINATION CAP: MAINTAIN CLEARANCES PRESCRIBED BY CODE ABOVE ADJACENT CHIMNEY FLUES W.P. MEMBRANE CONT. UP WALL 2" 10" 2" 2" FIREPLACE FLUE INTERIOR EXTERIOR STONE VENEER ATTACHED PER 1/A6.1 RE: ELEVATION LAP MIRADRAIN OVER ICE & WATER SHIELD OVER FLASHING TO ALLOW PROPER WALL DRAINAGE PFSM CRICKET LAPPED OVER SOLID BLOCKING OVER HIGH TEMP ICE & WATER SHIELD PFSM FLASHING W/ DRIP EDGE AS SHOWN 2X FRAMING CRICKET STRUCTURE RE: STRUCTURAL PROVIDE BLOCKING RE: STRUCTURAL PROVIDE SOLID BLOCKING TO SUPPORT STONE VENEER RE: STRUCTURAL CONTINUE ROOF ICE & WATER SHIELD UP CHIMNEY WALL TO T.O CHIMNEY US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 8/18/2014 3:11:52 PM As indicated 2722 CORTINA LANE VAIL RIDGE SUBDIVISION, BLOCK B, LOT 13 , VAIL CO A7.1 FIREPLACE SHEET 8-18-14 AG HB 8-18-14 BUILDING PERMIT 1 1/2" = 1'-0" 1 CHIMNEY SECTION 1 1/2" = 1'-0" 2 FIREPLACE DETAIL @ CRICKET INTERSECTION REVISION SCHEDULE # DESCRIPTION DATE 09/17/14