HomeMy WebLinkAbout2722 Cortina Lane Electrical LOAD CALC.pdfA-Phase Electric, LLC 2272 Cortina Lane
Vail, CO
Load Calculation
General Lighting and Receptacle Demand Load:
3880 sq. ft. x 3VA = 11640
1,500 VA x 2= 3000
1,500 VA x 1 = 1500
Total connected load: 16,140
3,000 VA @ 100% = 3,000
VA @ 35% = 4,599.0
1609.65
Total general lighting and
Receptacle demand load: 4,610
Range demand load:
12,000VA 8,000
Dryer Load:
5,000
Fixed appliance load:
Dishwasher 1 1,200
Garbage disposal 1 800
microwave 1 1,200
UC refrigerator 1 1,200
steam shower 1 8,000
subtotal 12,400
demand factor -25% 3,100
Total fixed appliance load: 9,300
Heating load:
heat tape 4800
Total heating load: 4,800
25% of largest motor: 200
continued next page
www.aphaseelectricllc.com
A-Phase Electric, LLC 2272 Cortina Lane
Vail, CO
Load Calculation
Totals:
General lighting and receptacles: 4,610
Range: 8,000
Dryer: 5,000
Fixed appliance: 9,300
Heating: 4,800
25% of largest motor: 200
Total:VA 31,910
AMPS 132.96
Proposed Service Size: 200A single phase
x
www.aphaseelectricllc.com