Loading...
HomeMy WebLinkAbout2722 Cortina Lane Electrical LOAD CALC.pdfA-Phase Electric, LLC 2272 Cortina Lane Vail, CO Load Calculation General Lighting and Receptacle Demand Load: 3880 sq. ft. x 3VA = 11640 1,500 VA x 2= 3000 1,500 VA x 1 = 1500 Total connected load: 16,140 3,000 VA @ 100% = 3,000 VA @ 35% = 4,599.0 1609.65 Total general lighting and Receptacle demand load: 4,610 Range demand load: 12,000VA 8,000 Dryer Load: 5,000 Fixed appliance load: Dishwasher 1 1,200 Garbage disposal 1 800 microwave 1 1,200 UC refrigerator 1 1,200 steam shower 1 8,000 subtotal 12,400 demand factor -25% 3,100 Total fixed appliance load: 9,300 Heating load: heat tape 4800 Total heating load: 4,800 25% of largest motor: 200 continued next page www.aphaseelectricllc.com A-Phase Electric, LLC 2272 Cortina Lane Vail, CO Load Calculation Totals: General lighting and receptacles: 4,610 Range: 8,000 Dryer: 5,000 Fixed appliance: 9,300 Heating: 4,800 25% of largest motor: 200 Total:VA 31,910 AMPS 132.96 Proposed Service Size: 200A single phase x www.aphaseelectricllc.com