HomeMy WebLinkAboutB14-0302 Blower Door Test.pdfD
Ar1rl,I\YE
ENER {}I ES.,.c.
Background
2722 Cortina Lane
Final Blower Door Report
Test Date:
Builder:
October 26, 2015
Vail Custom Builders
Contact: Benno Scheidegger
Site Address: 2722 Cortina Lane, Vail
Testing By: Jason Wemgast
HERS Rating Company: Active Energies
The project goal is to undergo testing at final construction to determine if the project meets code
requirements for air leakage (3ACH50) and identify any weak areas or difficult details tor
correction. Active Energies was contracted to perform a rough blower door test and thermal
infrared imaging to determine identify any areas of improvement prior to final construction.
Site Observations
A final Blower Door test was completed for the residence the located at 2722 Cortina Lane on
Monday, October 26, 2015. Construction was complete.
Blower Door Test
Air leakage
The home was depressurized to the standard -50 Pa of pressure, and a leakage of 1,075
CFM@50 was projected.
The ACH50, the rating used by the Town of Vail building code and requirements, was calculated
to be 1.26.
Please call with any questions or concerns. Thank you.
Kristen Hartel
ACTIVE ENERGIES, INC.
970-306-4248
Kristen@ActiveEnergies.com
www.activeenergies.com
Page 1of1 10/27/2015