Loading...
HomeMy WebLinkAboutB14-0302 Blower Door Test.pdfD Ar1rl,I\YE ENER {}I ES.,.c. Background 2722 Cortina Lane Final Blower Door Report Test Date: Builder: October 26, 2015 Vail Custom Builders Contact: Benno Scheidegger Site Address: 2722 Cortina Lane, Vail Testing By: Jason Wemgast HERS Rating Company: Active Energies The project goal is to undergo testing at final construction to determine if the project meets code requirements for air leakage (3ACH50) and identify any weak areas or difficult details tor correction. Active Energies was contracted to perform a rough blower door test and thermal infrared imaging to determine identify any areas of improvement prior to final construction. Site Observations A final Blower Door test was completed for the residence the located at 2722 Cortina Lane on Monday, October 26, 2015. Construction was complete. Blower Door Test Air leakage The home was depressurized to the standard -50 Pa of pressure, and a leakage of 1,075 CFM@50 was projected. The ACH50, the rating used by the Town of Vail building code and requirements, was calculated to be 1.26. Please call with any questions or concerns. Thank you. Kristen Hartel ACTIVE ENERGIES, INC. 970-306-4248 Kristen@ActiveEnergies.com www.activeenergies.com Page 1of1 10/27/2015 P.O. Box 7627, Avon, CO 81620 I P: 970.306.4233 I F: 866.403.3485 I www.activeenergies.com