HomeMy WebLinkAboutA110.pdfNOTES
WALL
TAG
WALL
HEIGHT
FULL
HEIGHT
1A
1B
1C
1D
2B
2A
2C
2D
4'-0"
PARTIAL HT.
12'-0"
PARTIAL HT.
5'-3 1/2"
3B
3A
FULL HT.
3C
13'-0"
TO U.O. SLOPED
CEILING
PARTITION LEGEND
EXISTING PARTITION -REPAIR
AS REQ'D TO MAINTAIN
RATINGS AND ACCEPT FINAL
TENANT FINISHES
NEW FULL HEIGHT PARTITION
NEW LOW HEIGHT PARTITION,
SEE PARTITION SCHEDULE
FOR HEIGHT
FULL HT.
PARTIAL HT.
WET WALL
PARTITION SCHEDULE
EXISTING BRICK WALL
EXISTING C.M.U. WALL
WALL
TAG
WALL
HEIGHT
FURRING WALL
4A
4B
4C
4D
FULL HT.
FULL HT.
FULL HT.
FULL HT.
4E PARTIAL HT.
4F PARTIAL HT.
4G PARTIAL HT.
4H PARTIAL HT.
KEYNOTES
# - KEYNOTE SYMBOL
GENERAL NOTES
SEE SHEET A510 FOR PARTITION
TYPES & RELATED DETAILS
SEE SHEET A510 FOR PARTITION
TYPES & RELATED DETAILS
1E
FULL
HEIGHT
FULL
HEIGHT
FULL
HEIGHT
FULL
HEIGHT
FULL HT.
REFER TO D110 FOR LOD, COLUMN GRID & EXISTING WALLS TO REMAIN DIMENSIONS.
2E
TOP OF
FITROOM
HEIGHT
TOP OF
CUBBY SHELF
FEASIBILITY OUTLINE
COST ITEM
$98,000 TOTAL VALUATION FOR PRIMARY FUNCTION AREA
$5,000 STAIR AND HANDRAILS
$1200 ADA FITROOM
$800 ADA POS STATION
$200 ACCESSIBLE SIGNAGE
$16,000 ACCESSIBLE RAMP
$19,600 20% OF TOTAL VALUATION (.20 * 95,000)
ACCESSIBLE CONSTRUCTION
$23,200 TOTAL VALUATION FOR ACCESSIBLE CONSTRUCTION
PER CODE SECTION 3411.7 EXCEPTION 1:
THE RAMP WON'T BE INSTALLED AS IT IS TECHNICALLY
INFEASIBLE TO ADD IT TO THE OVERALL CONSTRUCTION
COST.
VC ADT SSE
BRICK PAVER
COMMON AREA
5
7
12 13 14
A
B
C
D
2
1
PANTWALL
MEN'S SECTION
STOCK
ROOM
FITROOMS
SALES AREA
CASH DESK
PATIO FURNITURE
FLOWER BOX
FLOWER BOX
PATIO FURNITURE
02
12'-10"
4'-0"
5'-0"
01
1
1
1
1
2
4
1A
1A
1A
1A
1A
2D
2E
2D
4A
4A
1'-8 1/2"
15
11
10
10
10
10
10
9'-2 1/2" 21'-3 1/2" 23'-5"
V.I.F.
14'-11 1/2"
V.I.F.
1'-5 1/2"
HOLD
9'-7"
5'-9 1/2"
8'-4 1/2"
5'-5" 11'-4"
HOLD
4'-6 1/2"
4'-10"
V.I.F.
11'-1"
V.I.F.
3'-10"
V.I.F.
1'-6 1/2"
STAFF
AREA
DOORMAX EAS
SECURITY SYSTEM,
SEE E130.1 FOR MORE
INFORMATION
ADJACENT
TENANT
EXTERIOR
EXTERIOR
ADJACENT
TENANT
(E) COMMON
RESTROOM
(E) COMMON
RESTROOM
4A
10
2
HOLD
5'-9 1/2"
8
2
(E) FOUNDATION
LEVEL CHANGE
8
10"
0'-0"
FIN. FLOOR
1'-7 1/4"
FIN. FLOOR
2
10" 10 1/2"
2
2
CORRIDOR
6'-0"
2E
4A
A521
1
RELOCATE (E) PRESERVED
AIR TRANSFER GRILL
ABOVE DOOR OR PROVIDE
NEW TO MATCH SIZE.
(E) WHEELCHAIR LIFT TO
COMMON AREA AND
RESTROOMS
REZA A. HADAEGH
402807
S
T
A
T
E
O
F
C
O
L
O
R
A
D
O
L
I
C
E
N
S
E
D
A
R
C
H
I
T
E
C
T
Scale:
Job Number:
Drawing:
LULULEMON ATHLETICA
CONSTRUCTION STANDARDS
Checked By:
Drawn By:
Date:
ISSUED FOR DD-LLL xx/xx/xx
ISSUED FOR DD-LLD
ISSUED FOR CD-LLL 07/31/14
ISSUED FOR CD-LLD 08/14/14
ISSUED FOR PERMIT 08/15/14
ISSUED FOR BID xx/xx/xx
ISSUED FOR SD NA
07/03/14
19780
08/15/14
A110
CONSTRUCTION PLAN
NA
BAB
193 EAST GORE CREEK PLAZA
Vail, CO 81657 A UNLESS OTHERWISE NOTED ON PLANS, FURNISH AND INSTALL COMPLETELY ALL PARTITIONS, AND
SIMILAR STRUCTURES IN ACCORDANCE WITH SPECIFICATIONS, COMPLETE WITH DOOR TRIM,
HARDWARE AND DECORATIVE TREATMENTS AS INDICATED ON PLANS AND/OR ELEVATIONS AND
RELATED DETAILS INCLUDING ALL REQUIRED ROUGH AND FINISH HARDWARE.
B G.C. TO VERIFY THAT ALL PENETRATIONS IN SLAB ARE FREE OF ALL OBSTRUCTIONS INCLUDING,
BUT NOT LIMITED TO IN SLAB CONDUIT, REBAR, ETC. G.C. TO COORDINATE AND RETAIN
APPROVAL FROM LANDLORD FOR ALL SLAB PENETRATIONS PRIOR TO COMMENCING WORK.
C SEE SHEET A130 FOR GYPSUM BOARD FINISH LEVELS.
D WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE ON THE CONSTRUCTION DOCUMENTS. DO
NOT SCALE DRAWINGS. SUBMIT TO ARCHITECT ANY DISCREPANCIES FOR CLARIFICATION.
E APPROVED FIRE EXTINGUISHERS SHALL BE INSTALLED AS REQUIRED BY LOCAL AUTHORITY.
F ACCESS PANELS IN WALL FOR PLUMBING, MECHANICAL OR ELECTRICAL ACCESS TO BE FLUSH
FRAMELESS GYP. BD. PANELS, CEILING ACCESS PANELS SHALL BE PUSH UP TYPE 1 - REQUIRED
FOR STOREFRONT SIGN TRANSFORMERS AND/OR ROLL-UP GRILLE ARE TO BE FURNISHED AND
ISTALLED BY CONTRACTOR. G.C. TO SPECIFY & SUBMIT TO ARCHITECT FOR REVIEW &
APPROVAL.
G USE NO COMBUSTIBLE MATERIALS ABOVE SUSPENDED CEILINGS. FIRE RETARDANT TREATMENTS
WILL BE EXTENDED TO STRUCTURAL CEILING WHEREVER REQUIRED FOR CODE COMPLIANCE.
H USE MINIMUM 20 GAUGE METAL STUDS OR 7/8" METAL FURRING CHANNELS, TYPE AND SPACING IN
ACCORDANCE WITH LOCAL BUILDING REQUIREMENTS, NORMAL SPACING OF 16" O.C., FOR
FRAMING PARTITIONS AND SIMILAR CONSTRUCTION U.N.O.
J ALL INTERIOR PARTITIONS SHALL EXTEND 6" MIN ABOVE HIGHEST ADJACENT FINISHED CEILING,
UNLESS SPECIFIED OTHERWISE.
K ALL WALLS TO BE PREPARED FOR PAINT TO GYPSUM B.O. FINISH LEVELS SPECIFIED IN FINISH
SCHEDULE.
L PROVIDE DIAGONAL BRACING TO STRUCTURE ABOVE ALL DOORS, GLAZING HEADS AND JAMBS
AS REQUIRED TO MAKE ASSEMBLY RIGID.
M CONTRACTOR IS RESPONSIBLE FOR MAINTAINING INTEGRITY OF RATED PARTITIONS &
STRUCTURE PARTICULARLY WHERE PENETRATED BY VARIOUS TRADES AND SERVICES.
N PROVIDE WATER PROOF MEMBRANE 5'-0" BEYOND ALL PLUMBING FIXTURES AND RESTROOMS
WITH 6" MIN UP ADJACNT WALLS.
P SEE ENLARGED STOREFRONT PLANS AND DETAILS FOR STOREFRONT DIMENSIONS AND OTHER
CRITICAL INFORMATION.
R THE G.C. SHALL REVIEW ALL ELEVATIONS, FIXTURE PLANS AND DETAILS FOR LOCATIONS OF
METAL STRAP BACKING IN WALLS AND MOUNTING REQUIREMENTS FOR FIXTURES, EQUIPMENT AND
GRAPHIC/SIGN INSTALLATION PRIOR TO BEGINNING CONSTRUCTION. THE G.C. SHALL
COORDINATE ALL SUCH BACKING WITH MANUF. INSTRUCTIONS.
S THE G.C. SHALL INSTALL MOISTURE RESTITANT GYP. BD. TO 4'-0" A.F.F. MIN ALL TOILET ROOMS,
AROUND MOP SINKS, KITCHNETTE, LIMITED EXTERIOR EXPOSURES AND OTHER LOCATIONS
SUSCEPTABLE TO MOISTURE U.N.O.
1 DASH/DOT LINE INDICATES LEASE LINE.
2 EXISTING DEMISING WALL. PATCH AND REPAIR TO LIKE NEW CONDITION.
3 EXISTING COLUMN. LOCATION TO BE VERIFIED IN FIELD BY G.C.
4 RELOCATED, EXISTING OR NEW (CIRCLE ONE) ELECTRICAL PANELS. SEE
ELECTRICAL DRAWINGS.
5 SWITCH BANK. SEE ELECTRICAL DRAWINGS.
6 DISPLAY PLATFORM. SEE ELEVATION FOR HEIGHT.
7 SAFE TO BE INSTALLED IN CASH DESK BY G.C.
8 WALL CAP AT LOW HEIGHT PARTITION. SEE DETAIL 10/A510
9 TELEPHONE BACKER BOARD. FIRE-RATED PLYWOOD. PAINT TO MATCH WALL.SEE
6/E510
10 LINE OF SOFFIT ABOVE. SEE RCP FOR MORE INFORMATION.
11 WATER FEATURE. SEE SHEET A823 FOR MORE INFORMATION.
12 VOLUME CONTROL. SEE ELECTRICAL DRAWINGS.
13 ADT CONTROL. SEE ELECTRICAL DRAWINGS.
14 SOUND SYSTEM MOUNTED IN FIXTURE. SEE ELECTRICAL DRAWINGS.
15 EAS CONTROL BOX LOCATION. REFER TO ELEVATIONS FOR SPECIFIC
LOCATION.
SCALE: 3/8" = 1'-0"
1
CONSTRUCTION PLAN
TRUE
NORTH
NO. DATE
DESCRIPTION
10/08/14