HomeMy WebLinkAboutA120.pdfGENERAL NOTES
KEYNOTES
# - KEYNOTE SYMBOL
*REFER TO FINISH SCHEDULE & FIXTURE SCHEDULE
FOR TAGGED ELEMENTS
SURFACE
MOUNTED FITTING
ROOM
PARTITION
LED-F
FITTING
ROOM
PARTITION
LED-FM
SYMBOL LEGEND
SURFACE
MOUNTED
SUSPENDED
SURFACE
MOUNTED OR
SUSPENDED
EX1
SURFACE
MOUNTED OR
SUSPENDED
EX2
EX3
SURFACE
MOUNTED OR
SUSPENDED
CLG.
WALL
INSTALL NAME & SYMBOL
ACCESS
PANEL
INSTALL NAME & SYMBOL INSTALL NAME & SYMBOL INSTALL NAME & SYMBOL INSTALL NAME & SYMBOL
T1
T2
INSTALL NAME & SYMBOL
SUSPENDED D3
SUSPENDED D4
D6
F4EM
F8
FL
F8EM
F4
SUSPENDED HB
RA3
RF3
RF1
SURFACE
MOUNTED
SDS
RECESSED
SDR
RECESSED RF4
SUSPENDED SDP
TRACK
MOUNTED
TL1
TRACK
MOUNTED
TL3
TBD D7
SURFACE
MOUNTED
D5
NOTE: REFER TO E120 FOR LIGHTING SPECIFICATIONS & QUANTITIES
SURFACE
MOUNTED
OR SUSPENDED
RECESSED
SURFACE
MOUNTED
OR SUSPENDED
SURFACE
MOUNTED
OR SUSPENDED
WALL
MOUNTED
SURFACE
MOUNTED
OR SUSPENDED
RECESSED
RECESSED
RECESSED
TBD D8
TBD D9
F9 SUSPENDED RF3
RECESSED
EM
SOFFIT
7'-5" A.F.F.
U.S. OF DECK
11' - 2 3/4" A.F.F.
(E) SPRINKLER
PIPE
LED-F LED-FM
LED-FM
LED-FM LED-F
LED-F
A B C D
2
1
C
L
PANTWALL
MEN'S SECTION
STOCK
ROOM
FITROOMS SALES AREA
CASH DESK
STAFF
AREA
ADJACENT
TENANT
EXTERIOR
EXTERIOR
ADJACENT
TENANT
RESTROOM
RESTROOM
CORRIDOR
RF3
5
3'-10"
D4
D4
D3 D3 D3 3'-6"
6'-0"
RF3
RF3 RF3
RF3 RF3
RF3 RF3
RF3EM
EX2
T2
TL1
T2
TL1
T2
TL1
T2
TL1
4"
4"
3
2
3
2
T2
TL1
(E) SPRINKLER
PIPE
T2
TL1
2'-4"
1'-7"
11" 1'-3" 2'-2"
4'-4"
SLOPED CEILING
12'-11"
G.C. TO ENSURE TRACK
LIGHT FIXTURES ARE HUNG
LEVEL IN SLOPED CEILING
AREA,TYP.
3
EQ EQ
EX1
EQ EQ
3'-10"
4'-4" 11" 4'-0"
2'-1 1/2"
4'-0" 11" 4'-4"
1'-4" 3'-3 1/2" 4'-1" 4'-1" 3'-5 1/2" 3'-5 1/2" 2'-10 1/2" 4'-4"
3'-1 1/2"
2'-7"
2'-7"
LED-FM
LED-FM
LED-FM LED-FM
4'-4"
V.I.F.
1'-4"
7 7 7
7
(E) PIPING
7
G.C. TO LOCATE
LED FITROOM
DRIVERS IN
STORAGE AREA
SOFFIT. G.C. TO
PROVIDE AN
ACCESS PANLE.
(E) PIPING
BEAMS ABOVE. G.C. TO
VERIFY LOCATION AND
NOTIFY ARCH. OF
DISCREPANCIES
SOFFIT
7'-5 3/4" A.F.F.
SOFFIT
9'-1 1/2" A.F.F.
A.C.T
7'-1" A.F.F. LED-FM
T2
TL1
T2
TL1
T2 TL1
T2 T2
TL1
T2
TL1 TL3
T2
TL1
T2
TL1
SOFFIT
7'-10 1/2" A.F.F.
F9
F9
F9
F9
F9
F9
F9
F9
D5
5'-6 3/4" 5'-3 3/4"
10'-0"
6'-0"
4'-0"
2'-1 1/2"
4'-0"
5'-2 3/4"
2'-3 1/2" 3'-2" 2'-10" 3'-0 3/4"
RF1
EQ EQ
3'-7 3/4"
8'-0"
8'-0" 2'-5 1/4"
LED-FM LED-FM
LED-FM LED-FM
LED-FM LED-FM
LED-FM LED-FM
LED-FM
LED-FM
LED-FM
F9
EX3
EX3
D5
D4
D4
D4
D5
EX3
3'-1"
12'-3"
EX3
EX3 LED-FM
EX3
LOW HVAC
DUCTING
CLG. HT.
9'-7 1/2" A.F.F.
G.C. TO VERIFY EXISTING
DUCTING AND INFORM
LULULEMON IN CASE OF
CONFLICT WITH PROPOSED
RECESSED LIGHTING.
A.C.T
7'-1" A.F.F.
A California Corporation
ARCHITECTURE
20521 EARL STREET
TORRANCE, CA 90503
T. 310-343-3430 | F. 310-343-3431
www.menemshasolutions.com
LOS ANGELES | BOSTON
Plans, maps, specifications, studies, and
reports not containing a red ink seal imprint
accompanied by an original signature by
the licensed professional may have been
fraudulently altered and shall not be
considered an original copy. All information
should be disregarded unless verified by
the professional whose signature appears
above. Copyright Protected 2012.
Architect:
REZA A. HADAEGH
402807
S
T
A
T
E
O
F
C
O
L
O
R
A
D
O
L
I
C
E
N
S
E
D
A
R
C
H
I
T
E
C
T
Scale:
Job Number:
Drawing:
LULULEMON ATHLETICA
CONSTRUCTION STANDARDS
Checked By:
Drawn By:
Date:
ISSUED FOR DD-LLL xx/xx/xx
ISSUED FOR DD-LLD
ISSUED FOR CD-LLL 07/31/14
ISSUED FOR CD-LLD 08/14/14
ISSUED FOR PERMIT 08/15/14
ISSUED FOR BID xx/xx/xx
ISSUED FOR SD NA
07/03/14
19780
08/15/14
A120
CEILING PLAN
NA
BAB
193 GORE CREEK DRIVE
Vail, CO 81657 A G.C. TO VERIFY QUANTITY AND SPECIFICATION OF ALL FIXTURES UPON DELIVERY TO
THE SITE.
B G.C. TO INFORM ARCHITECT IF THERE IS A CONFLICT BETWEEN ARCHITECTURAL,
ELECTRICAL, AND MECHANICAL PLANS.
C AVOID PENETRATING CEILING DECK WITHOUT AUTHORIZATION FROM LANDLORD. SEE
A520 FOR CONNECTION DETAILS.
D SUSPENDED TRACKS FOR TRACK LIGHTS TO BE HUNG WITH THREADED ROD.
E HVAC DUCTWORK, DIFFUSERS, AND ACCESS HATCHES ARE FOR REFERENCE ONLY ON
THIS PLAN. SEE A122 FOR HORIZONTAL LOCATIONS AND HEIGHTS.
1 DIAGONAL REFERENCE USED FOR CURVE CONSTRUCTION.
2 DISPLAY SYSTEM TRACKS SPACED EVENLY 6” O.C. FURNISHED BY OWNER AND
INSTALLED BY G.C.
3 TRACK LIGHTS TO BE INSTALLED 4" FROM GLAZING.
4 HVAC DIFFUSER PER MECHANICAL DRAWINGS LOCATE PER A122
5 ACOUSTICAL CEILING TILE.
6 5’-0” DIAMETER CEILING OPENING WITH CHANDELIER SUSPENDED FROM STRUCTURE
ABOVE.
7 LED LIGHT FIXTURE - REFER TO LIGHTING SCHEDULES ON ELECTRICAL DRAWINGS
8 G.C. TO PROVIDE 24"X24" CEILING ACCESS PANEL TO ACCESS LED DRIVERS
SCALE: 3/8" = 1'-0"
1
REFLECTED CEILING PLAN
TRUE
NORTH
NO. DATE
DESCRIPTION
10/08/14