HomeMy WebLinkAboutA130.pdfB-1
P-2
SOFFIT FACE
ABOVE
P-9
P-6
P-7
P-7
P-10
P-10
P-9
P-10
P-2
P-2
CEILING
ACT-1
P-13
WALLS
FLOOR
P-1
CEILING
B-1
WD-1
FLOOR
MAS-1
MAS-1
MAS-1
MAS-1
A
B C
D
2
1
ADJACENT
TENANT
EXTERIOR
EXTERIOR
ADJACENT
TENANT
P-2
SOFFIT FACE
ABOVE
P-2
SOFFIT FACE
ABOVE
P-2
SOFFIT FACE
ABOVE
B-1
P-2
OPEN
CEILING
P-6
P-6
P-7
P-7
P-7
B-2
RUB-1
P-1
CEILING
RESTROOM
RESTROOM
CORRIDOR
P-9
P-2
P-2
P-2
P-7
9
13'-7 1/2"
U.O. SOFFIT
U.O. SOFFIT
U.O. SOFFIT
MAT-1
P-7
P-7
TILE-5 MOUNTED
TO THE BACK OF
SLATWALL
(E) CONC FLOOR TO BE
PATCHED AND REPAIRED
AS NECESSARY TO RECEIVE
STAIN AND SEAL.
WD-5
CEILING BEAM
P-9
TILE-5
TILE-5
P-7
FLOOR
NATIONAL ACCOUNT
FINISH LEVELS
BENJAMIN MOORE NATIONAL ACCOUNT CONTACTS:
NATIONAL ACCOUNT: LULULEMON ATHLETICA
PRODUCT ORDER CODE: NA048
DIRECT ORDER LINE: 1.877.6.COLOR.6
WEBSITE: www.benjaminmoore.com
NAME: JENNIFER HALWARD
TITLE: ARCHITECTURAL REPRESENTATIVE CA.
COMPANY: BENJAMIN MOORE & Co. Ltd.
ADDRESS: 26680 GLOUCESTER WAY
ALDERGROVE, BC. CANADA V4W 3V6
TEL: 778.549.7052
FAX: 604.857.0700
EMAIL: jennifer.halward@benjaminmoore.com
GWB FINISH LOCATION
LEVEL 1
LEVEL 2
LEVEL 4
PLENUM AND NON-FINISH AREAS
AREAS COVERED WITH TILE
NON CUSTOMER ACCESSIBLE AREAS
ALL PAINTED SURFACES W/ TOUGH HIDE PRIMER IN CUSTOMER
ACCESSIBLE AREAS
DAL TILE NATIONAL ACCOUNT CONTACTS:
NATIONAL ACCOUNT: LULULEMON ATHLETICA
DIRECT ORDER LINE: 1.877.556.5728
DIRECT ORDER EMAIL: national.accounts@daltile.com
NAME: KAREN FOURCHALK
TITLE: ARCHITECTURAL REPRESENTATIVE
COMPANY: DAL TILE
TEL: 604.251.8995
CELL: 604.861.1718
FINISH SCHEDULE
P-1
P-2
P-5
P-3
P-4
FLOORING
MANUFACTURER
REMARKS MODULE MATERIAL
PAINTS
BENJAMIN MOORE
ECOSPEC WB
OPEN CEILING /
HVAC / EXPOSED
CEILING ITEMS
FLAT
FLAT
NOVEMBER RAIN 2142-60
ICICLE 2142-70
FOR OVERALL CEILING - BENJAMIN MOORE
REQUIRED TINTED PRIMER TO BE USED. GC TO
PROVIDE THREE COATS OF PAINT MINIMUM.
FOR CEILING ACCENTS & SOFFITS - BENJAMIN
MOORE REQUIRED TINTED PRIMER TO BE USED. GC
TO PROVIDE THREE COATS OF PAINT MINIMUM.
MFR./MODEL LOCATION COLOR
REMARKS
FINISH
FLAT
STUDIO FINISHES LATEX CHALK-
BOARD PAINT-BLACK, 307-80
EGGSHELL
BENJAMIN MOORE
ECOSPEC WB
BENJAMIN MOORE
ECOSPEC WB
BENJAMIN MOORE
ECOSPEC WB
BENJAMIN MOORE
ECOSPEC WB
EGGSHELL
WHITE OPULENCE, OC-69
TBD BY LLL
HARD LIDS /
SOFFITS
TBD
-
BENJAMIN MOORE REQUIRED TINTED PRIMER TO
BE USED. GC TO PROVIDE THREE COATS OF
PAINT MINIMUM.
S.F. OF WOOD FLOOR
WD-1
WD-2
0 S.F.
WEBSITE: http://daltile.com/
WD-1
TILE-2
RUB-1
STN-1
STN-2
TILE-3
TILE-1
WALLS
5" W X 3/4"
TONGUE &
GROOVE
SEE SPECIFICATION FOR MORE INSTALLATION AND ADDITIONAL
INFORMATION.
12" X 24" X 3/8"
EXPANKO- REZTEC
-OR ALTERNATIVE-
MONDO HARMONI
RUBBER FLOORING
24" x 24" x 1/8"
(4MM)
JUNKERS
WOOD STAIN
WOOD STAIN
MILL WORKER
MILL WORKER
TOILET ROOM WALLS
SEE ELEVATION FOR HEIGHT, SHEET A310
STOCK ROOM
PORCELAIN TILE DAL TILE
TOILET ROOM
FLOOR
CERAMIC TILE
4 1/4" X 12
3/4" X 3/8"
BULLNOSE
S-4449
16" X 16" X 3/8"
SLATE TILE
ENTRY TILE SEALANT: AQUA MIX
-15 YEAR WARRANTY W/ CLEAR FINISH O.A.E.
NOTE: A CHANGE OF TILE-2 SPEC REQUIRES SPECIFICATION FOR NEW
TILE-2 SPEC SHOWING JURISDICTIONAL REQUIREMENTS FOR FLOOR
APPLICATIONS HAVE BEEN MET
GROUT
GROUT
GROUT
DAL TILE
MAPEI
KERACOLOR
LATICRETE
MAPEI
KERACOLOR
DAL TILE
WD-2
VINTAGE
MAT-1
AMERICAN FLOOR
MATS
WALK OFF MAT
5/8" THICK
STORE ENTRANCE
TILE-4
KITCHEN BACKSPLASH PROVIDE BULLNOSE AT OPEN ENDS
CERAMIC TILE
3"X6"X3/8"
OFF-SET
PATTERN
GROUT
DAL TILE
LATICRETE
P-6 BENJAMIN MOORE
ECOSPEC WB
EGGSHELL TBD BY LLL BENJAMIN MOORE REQUIRED TINTED PRIMER TO
BE USED. GC TO PROVIDE THREE COATS OF
PAINT MINIMUM.
P-7 BENJAMIN MOORE
ECOSPEC WB
EGGSHELL TBD BY LLL BENJAMIN MOORE REQUIRED TINTED PRIMER TO
BE USED. GC TO PROVIDE THREE COATS OF
PAINT MINIMUM.
P-8 BENJAMIN MOORE
ECOSPEC WB
EGGSHELL TBD BY LLL BENJAMIN MOORE REQUIRED TINTED PRIMER TO
BE USED. GC TO PROVIDE THREE COATS OF
PAINT MINIMUM.
P-9 BENJAMIN MOORE
ECOSPEC WB
EGGSHELL TBD BY LLL BENJAMIN MOORE REQUIRED TINTED PRIMER TO
BE USED. GC TO PROVIDE THREE COATS OF
PAINT MINIMUM.
P-10 BENJAMIN MOORE
ECOSPEC WB
EGGSHELL TBD BY LLL BENJAMIN MOORE REQUIRED TINTED PRIMER TO
BE USED. GC TO PROVIDE THREE COATS OF
PAINT MINIMUM.
P-11 BENJAMIN MOORE
ECOSPEC WB
EGGSHELL TBD BY LLL BENJAMIN MOORE REQUIRED TINTED PRIMER TO
BE USED. GC TO PROVIDE THREE COATS OF
PAINT MINIMUM.
P-12 BENJAMIN MOORE
ECOSPEC WB
EGGSHELL TBD BY LLL BENJAMIN MOORE REQUIRED TINTED PRIMER TO
BE USED. GC TO PROVIDE THREE COATS OF
PAINT MINIMUM.
P-13 BENJAMIN MOORE
ECOSPEC WB
EGGSHELL TBD BY LLL BENJAMIN MOORE REQUIRED TINTED PRIMER TO
BE USED. GC TO PROVIDE THREE COATS OF
PAINT MINIMUM.
P-14 BENJAMIN MOORE
ECOSPEC WB
EGGSHELL TBD BY LLL BENJAMIN MOORE REQUIRED TINTED PRIMER TO
BE USED. GC TO PROVIDE THREE COATS OF
PAINT MINIMUM.
BENJAMIN MOORE REQUIRED TINTED PRIMER TO
BE USED. GC TO PROVIDE THREE COATS OF
PAINT MINIMUM.
BENJAMIN MOORE REQUIRED TINTED PRIMER TO
BE USED. GC TO PROVIDE THREE COATS OF
PAINT MINIMUM.
LEVEL 5
MILLWORK
B-1
B-2
BASE
WOOD BASE
VINYL BASE JOHNSONITE
STORAGE ROOM AREA
FIXTURE VENDOR 4" HEIGHT
4" HEIGHT
ACT-1
CEILING
ACOUSTICAL CEILING TILE ARMSTRONG
2'X2'
TEGULAR TILE
STAFF ROOM AREA
HARDBOARD - 48" HEIGHT
SEE DETAIL 14/A510
MAS-1
0 S.F.
-
STOREFRONT
MENS/ CASH
-
WOMENS
FITROOMS
-
-
STOCKROOM
-
S.F. PROVIDED FOR REFERENCE AND
SHOULD BE CONFIRMED BY GC
MODEL/ COLOR
MODEL: WHITE OAK FUMED
COLOR: OLD OAK
JET EGG
CHESTER / NATURAL
SERIES: FABRIQUE COLOR: NOIR
LINEN P689
GROUT: #47 CHARCOAL,
1/8" GROUT LINE
SERIES: MODERN DIMENSIONS.
COLOR: MATTE ARCH. GRAY 0709
MUD
GROUT: #001 ALABASTER,
1/8 "GROUT LINE
SERIES: SLATE COLLECTION
COLOR: BRAZILIAN BLACK
GROUT: MAPEI #10 BLACK
1/4" GROUT LINE
ALTERNATIVE - W92 EBONY
TBD
SERIES: RITTENHOUSE ARCTIC
WHITE SEMI-GLOSS FINISH
GROUT: 44 BRIGHT WHITE,
1/8" GROUT LINE
40 BLACK
WHITE
TBD
MATCH WOOD FLOOR
WOOD FLOOR
WOOD FLOOR
WD-3
WOOD FLOOR
WD-4
WOOD FLOOR
JUNKERS
VINTAGE
5" W X 3/4"
TONGUE &
GROOVE
(2) 2 1/2" W X
9/16" TONGUE
& GROOVE
(2) 2 1/2" W X
9/16" TONGUE
& GROOVE
MODEL: RED OAK FUMED
COLOR: FUMED NATURAL
MODEL/ COLOR: BLACK OAK
HARMONY
MODEL/ COLOR: NATURAL OAK
HARMONY
SEE SPECIFICATION FOR MORE INSTALLATION AND ADDITIONAL
INFORMATION.
SEE SPECIFICATION FOR MORE INSTALLATION AND ADDITIONAL
INFORMATION.
SEE SPECIFICATION FOR MORE INSTALLATION AND ADDITIONAL
INFORMATION. ADD OIL TOP AT TURNOVER. SEE SPECS FOR
MORE INFORMATION.
WD-5
60503 WALNUT
BURLE
AT CEILING BEAMS, SEE DETAIL
1/A520
WOOD
TRESS FROG
VENEER
TILE TBD
TILE-5
GROUT TBD
TBD
TBD
GENERAL NOTES
KEYNOTES
# - KEYNOTE SYMBOL
A California Corporation
ARCHITECTURE
20521 EARL STREET
TORRANCE, CA 90503
T. 310-343-3430 | F. 310-343-3431
www.menemshasolutions.com
LOS ANGELES | BOSTON
Plans, maps, specifications, studies,and
reports not containing a red ink seal imprint
accompanied by an original signature by
the licensed professional may have been
fraudulently altered and shall not be
considered an original copy. All information
should be disregarded unless verified by
the professional whose signature appears
above. Copyright Protected 2012.
Architect:
REZA A. HADAEGH
402807
S
T
A
T
E
O
F
C
O
L
O
R
A
D
O
L
I
C
E
N
S
E
D
A
R
C
H
I
T
E
C
T
Scale:
Job Number:
Drawing:
LULULEMON ATHLETICA
CONSTRUCTION STANDARDS
Checked By:
Drawn By:
Date:
ISSUED FOR DD-LLL xx/xx/xx
ISSUED FOR DD-LLD
ISSUED FOR CD-LLL 07/31/14
ISSUED FOR CD-LLD 08/14/14
ISSUED FOR PERMIT 08/15/14
ISSUED FOR BID xx/xx/xx
ISSUED FOR SD NA
07/03/14
19780
08/15/14
A130
FINISH PLAN
NA
BAB
193 GORE CREEK DRIVE
Vail, CO 81657 SCALE: 3/8" = 1'-0"
1
FLOOR FINISH PLAN
A THE PAINT COLORS ARE, ECO SPEC BY BENJAMIN MOORE (NO SUBSTITUTIONS).
B ALL PRODUCTS, FINISHES & MATERIALS TO BE INSTALLED PER MANUFACTURER'S
SPECIFICATIONS.
C DOORS & FRAMES PAINTED TO MATCH WALL UNLESS SPECIFICALLY CALLED OUT.
D PRIMER TO BE USED ALWAYS AND PROVIDE MIN. TWO COATS OF FINISH PAINT
MORE COATS IF NEEDED.
E G.C. TO ENSURE A SMOOTH LEVEL CONCRETE SUB-FLOOR AS NEEDED FOR WOOD
INSTALLATION. PROVIDE LEVELASTIC (O.A.E.) WHERE REQUIRED TO ACHIEVE LEVEL
SUB-FLOOR. REFER TO MANUFACTURER SPECIFICATIONS FOR MORE INFORMATION
AND MOISTURE REQUIREMENTS. VERIFY IN FIELD PRIOR TO INSTALLATION OF
FLOORING (TYP.)
F TRANSITION PAINT COLORS ON AN INSIDE CORNER WHENEVER POSSIBLE.
G ALL AREAS & QUANTITIES ARE FOR DESIGN INTENT ONLY. THE G.C. SHALL VERIFY
ALL AREA & QUANTITIES REQUIRED PRIOR TO BID.
1 DIAGONAL REFERENCE USED FOR CURVE CONSTRUCTION.
2 EDGE OF TILE AND WOOD ALUMINUM EDGE STRIP THRESHOLD TO BE SMOOTH
TRANSITION.
3 TILE START CENTERED BETWEEN DOORS. THREE FULL TILES INTO THE STORE TO
ALIGN WITH THE EDGE OF THE DOOR FRAME. WHERE THERE IS TILE ON THE
EXTERIOR ALIGN WITH INTERIOR.
4 DISPLAY PLATFORM
5 G.C. TO INSTALL A WATER PROOF MEMBRANE UNDER THE TILE IN THE TOILET
ROOMS. MEMBRANE TO EXTEND UP WALLS A MIN. OF 4”
6 DRAIN TO BE START POINT OF TILE PATTERN. TILE TO NEVER BE CUT LESS THAN
6” WIDE.
7 SEE STOREFRONT SHEETS A711 FOR STOREFRONT FINISHES.
8 PAINT TO MATCH EXISTING AND/OR REQUIRED LLD FINISH
9 WATER FEATURE SEE RESPONSIBILITY AND FINISH SCHEDULE ON SHEET A823.
TRUE
NORTH
NO. DATE
DESCRIPTION
10/08/14